Displaying publications 161 - 180 of 288 in total

Abstract:
Sort:
  1. Lau KF, Tan KS, Goh KJ, Ramli N, Tai SM
    Ann Acad Med Singap, 2019 Mar;48(3):109-111.
    PMID: 30997481
    Matched MeSH terms: Cerebral Angiography; Magnetic Resonance Angiography
  2. Ovesen C, Jakobsen JC, Gluud C, Steiner T, Law Z, Flaherty K, et al.
    Stroke, 2021 08;52(8):2629-2636.
    PMID: 34000834 DOI: 10.1161/STROKEAHA.120.032426
    BACKGROUND AND PURPOSE: The computed tomography angiography or contrast-enhanced computed tomography based spot sign has been proposed as a biomarker for identifying on-going hematoma expansion in patients with acute intracerebral hemorrhage. We investigated, if spot-sign positive participants benefit more from tranexamic acid versus placebo as compared to spot-sign negative participants.

    METHODS: TICH-2 trial (Tranexamic Acid for Hyperacute Primary Intracerebral Haemorrhage) was a randomized, placebo-controlled clinical trial recruiting acutely hospitalized participants with intracerebral hemorrhage within 8 hours after symptom onset. Local investigators randomized participants to 2 grams of intravenous tranexamic acid or matching placebo (1:1). All participants underwent computed tomography scan on admission and on day 2 (24±12 hours) after randomization. In this sub group analysis, we included all participants from the main trial population with imaging allowing adjudication of spot sign status.

    RESULTS: Of the 2325 TICH-2 participants, 254 (10.9%) had imaging allowing for spot-sign adjudication. Of these participants, 64 (25.2%) were spot-sign positive. Median (interquartile range) time from symptom onset to administration of the intervention was 225.0 (169.0 to 310.0) minutes. The adjusted percent difference in absolute day-2 hematoma volume between participants allocated to tranexamic versus placebo was 3.7% (95% CI, -12.8% to 23.4%) for spot-sign positive and 1.7% (95% CI, -8.4% to 12.8%) for spot-sign negative participants (Pheterogenity=0.85). No difference was observed in significant hematoma progression (dichotomous composite outcome) between participants allocated to tranexamic versus placebo among spot-sign positive (odds ratio, 0.85 [95% CI, 0.29 to 2.46]) and negative (odds ratio, 0.77 [95% CI, 0.41 to 1.45]) participants (Pheterogenity=0.88).

    CONCLUSIONS: Data from the TICH-2 trial do not support that admission spot sign status modifies the treatment effect of tranexamic acid versus placebo in patients with acute intracerebral hemorrhage. The results might have been affected by low statistical power as well as treatment delay. Registration: URL: http://www.controlled-trials.com; Unique identifier: ISRCTN93732214.

    Matched MeSH terms: Cerebral Angiography; Computed Tomography Angiography
  3. Jung HJ, Kwon WK, Lee SJ, Mohamed N, Shin BM, Lee J, et al.
    BMC Anesthesiol, 2016 10 04;16(1):83.
    PMID: 27716083
    BACKGROUND: This study reports the efficacy of intraoperative transesophageal echocardiography (TEE) for evaluation of high take-off coronary ostia and proximal coronary arterial flows as an alternative to preoperative coronary angiography.

    CASE PRESENTATION: In a 65-year old male undergoing the bicuspid aortic valve (BAV) repair and the extensive remodeling of dilated sinus and tubular junction, and preoperative coronary angiography were unsuccessfully completed due to an allergic reaction to the contrast medium. Intraoperative TEE by employing various 3-dimensional volume images of coronary ostia and Doppler tracings of the coronary arterial flows enabled a thorough pre-procedural evaluation of the high take-off coronary arteries and post-procedural evaluation by confirming the absence of any compromise in coronary arterial flow.

    CONCLUSION: In the present case, intraoperative application of various TEE imaging modalities enabled comprehensive evaluation of high-taking off coronary artery, as an alternative to preoperative coronary angiography, in a patient undergoing an extensive aortic valve and aortic root repair procedure.

    Matched MeSH terms: Coronary Angiography/methods
  4. Ang AH, Lambeth JT, Soo YS, Ong SC
    Med J Malaya, 1970 Sep;25(1):8-16.
    PMID: 4249503
    Matched MeSH terms: Angiography*
  5. Aik Kah T
    Med Hypotheses, 2018 Jun;115:54-57.
    PMID: 29685198 DOI: 10.1016/j.mehy.2018.03.022
    Oral anticoagulants are widely used in the treatment and prevention of both venous and arterial thromboembolism. They are classified into vitamin K anticoagulants (VKAs) and non-vitamin K antagonist oral anticoagulants (NOACs). The main advantage of NOACs over VKAs is the absence of the need for continuous monitoring. However, there are concerns about their effectiveness and safety in certain clinical situations. In this manuscript, I discussed the possibility of using optical coherence tomography angiography [OCTA] in the monitoring of the activity of NOACs. The rapid development of OCTA technology is very promising. Further research and development will extend its use beyond the realm of ophthalmology.
    Matched MeSH terms: Angiography/methods*
  6. Sharifah AI, Jasvinder K, Rus AA
    Singapore Med J, 2009 Apr;50(4):e127-9.
    PMID: 19421665
    Pulmonary arteriovenous malformations are rare vascular anomalies. We report a 12-year-old girl who presented with exertional dyspnoea, cyanosis and clubbing since the age of five years, and multiple pulmonary arteriovenous malformations. Computed tomography pulmonary angiogram showed a large pulmonary arteriovenous malformation at the lower lobe of the right lung. Pulmonary angiogram showed a large right lung arteriovenous malformation and two small left lung arteriovenous malformations. The multiple arteriovenous malformations were occluded with Gianturco coils. She is now asymptomatic and on regular follow-up.
    Matched MeSH terms: Angiography*
  7. Wong AR, Suhaimi H, Ridzuan MA, Rizal MM, Saedah A
    Singapore Med J, 2009 Oct;50(10):e358-61.
    PMID: 19907875
    We present two infants whose endovascular lines were accidentally cut or fractured, and had to be retrieved via transcatheter means in the cardiac catheterisation laboratory. The first case was a two-month-old infant with transposition of the great arteries, requiring an emergency balloon atrial septostomy. An indwelling vascular catheter that was placed in the right femoral vein was accidentally cut and had migrated into the inferior vena cava, before being retrieved. The second case was a one-week-old neonate who presented with pneumonia at birth, and had a long intravenous catheter placed in the left saphenous vein, which became fractured, and subsequently migrated into the heart. This case presented as a pulmonary embolus with haemodynamic instability, as the catheter had partially obstructed the right ventricular outflow tract. This was later retrieved via transcatheter means.
    Matched MeSH terms: Angiography/methods
  8. Sridharan R, Low SF, Mohd MR, Kew TY
    Singapore Med J, 2014 Oct;55(10):e165-8.
    PMID: 25631906
    Epistaxis is commonly encountered in otorhinolaryngologic practice. However, severe and recurrent epistaxis is rarely seen, especially that originating from a pseudoaneurysm of the intracavernous internal carotid artery (ICA). We herein present the case of a 32-year-old man who was involved in a motor vehicle accident and subsequently developed recurrent episodes of profuse epistaxis for the next three months, which required blood transfusion and nasal packing to control the bleeding. Computed tomography angiography revealed a large intracavernous ICA pseudoaneurysm measuring 1.7 cm × 1.2 cm × 1.0 cm. The patient underwent emergent four-vessel angiography and coil embolisation and was discharged one week later without any episode of bleeding. He remained asymptomatic after three-month and one‑year intervals. This case report highlights a large intracavernous ICA pseudoaneurysm as a rare cause of epistaxis, which requires a high index of suspicion in the right clinical setting and emergent endovascular treatment to prevent mortality.
    Matched MeSH terms: Coronary Angiography/methods
  9. Saleh MD, Eswaran C
    PMID: 21331960 DOI: 10.1080/10255842.2010.545949
    Retinal blood vessel detection and analysis play vital roles in early diagnosis and prevention of several diseases, such as hypertension, diabetes, arteriosclerosis, cardiovascular disease and stroke. This paper presents an automated algorithm for retinal blood vessel segmentation. The proposed algorithm takes advantage of powerful image processing techniques such as contrast enhancement, filtration and thresholding for more efficient segmentation. To evaluate the performance of the proposed algorithm, experiments were conducted on 40 images collected from DRIVE database. The results show that the proposed algorithm yields an accuracy rate of 96.5%, which is higher than the results achieved by other known algorithms.
    Matched MeSH terms: Fluorescein Angiography/statistics & numerical data
  10. Sheth T, Chan M, Butler C, Chow B, Tandon V, Nagele P, et al.
    BMJ, 2015;350:h1907.
    PMID: 25902738 DOI: 10.1136/bmj.h1907
    To determine if coronary computed tomographic angiography enhances prediction of perioperative risk in patients before non-cardiac surgery and to assess the preoperative coronary anatomy in patients who experience a myocardial infarction after non-cardiac surgery.
    Matched MeSH terms: Coronary Angiography*
  11. Lee KR, Peng LY, Iqbal TB, Subrayan V
    Ocul Immunol Inflamm, 2018;26(8):1146-1149.
    PMID: 28362518 DOI: 10.1080/09273948.2017.1298821
    PURPOSE: To report a case of systemic lupus erythematosus-induced choroidal vasculitis.

    METHODS: A 34-year-old woman with a long-standing history of systemic lupus erythematosus had a sudden painless loss of vision in the right eye over 12 hours. Ocular examination revealed a visual acuity of counting fingers of 1 foot on the right eye and 20/20 on the left. There was a relative afferent pupillary defect on the right side with a pink, distinct optic disk margin.

    RESULTS: Optical coherence tomography of the macula and fundus fluorescein angiogram for the eyes were normal. The MRI brain and orbit with the cerebral MRA did not show signs of optic neuritis or occipital vasculitic changes. However, the indocyanine green angiography revealed patches of ill-defined areas of choroidal hypofluorescence in the early- to mid-phase in the macula region.

    CONCLUSION: ICGA becomes the crucial tool in unmasking the presence of choroidal vasculitis.
    Matched MeSH terms: Fluorescein Angiography*
  12. Masoomi MA, Al-Shammeri I, Kalafallah K, Elrahman HMA, Ragab O, Ahmed E, et al.
    Medicine (Baltimore), 2019 Jan;98(4):e14207.
    PMID: 30681596 DOI: 10.1097/MD.0000000000014207
    Many discrepancy in selection of proper filter and its parameters for individual cases exists. The authors investigate the impact of the most common filters on patient NM images with coronary artery disease (CAD), and compare the results with the computerized tomography (CT)-Angio and angiography for accuracy.The investigation initiated by performing various single photon emission computerized tomography (SPECT)/CT scan of the national electrical manufacturers association chest phantoms having hot and cold inserts. Data acquired on GE 670 PRO SPECT/CT; 360Ø, 64 frames, 60 seconds, low energy high resolution (LEHR) 128, low energy general purpose (LEGP) with CT attenuation (120 kV and 170 mA). The images reconstructed with filtered back projection and ITERATIVE ordered-subset expectation maximization utilizing filters; Hann, Butterworth, Metz, Hamming, and Wiener. The Image contrast was calculated to assess absolute nearness of the inserts. Based on the preliminary results, then scans of 92 patients with CAD; 64 males and 28 females, age 41 to 77 years old, who had been reported earlier reprocessed with the nominated filter and were reported by 2 NM expert. The results compared to the earlier reports and to the CT-Angio and angiography.The optimization suggested 3 filters; Wiener (Wi), Metz and Butterworth (But) provide the highest contrast (99- 66.4%) and (81- 32%) for the cold and hot inserts respectively, with the (Wi) filter to be the better option. The reprocessed patients scan with the (Wi) presented an elevated diagnostic accuracy, correlated well with the CT-Angio and angiography results (P 
    Matched MeSH terms: Computed Tomography Angiography*
  13. Zhang ZY, Yang WY, Dominiczak AF, Wang JG, Wu Y, Almustafa B, et al.
    Hypertension, 2019 11;74(5):1064-1067.
    PMID: 31422692 DOI: 10.1161/HYPERTENSIONAHA.119.13206
    Matched MeSH terms: Computed Tomography Angiography/methods
  14. Yip VCH, Wong HT, Yong VKY, Lim BA, Hee OK, Cheng J, et al.
    J Glaucoma, 2019 01;28(1):80-87.
    PMID: 30461553 DOI: 10.1097/IJG.0000000000001125
    AIM: To study the microvascular density of the macular and optic nerve head in healthy and glaucoma subjects using optical coherence tomography angiography.

    METHODOLOGY: We performed a cross-sectional cohort study on healthy subjects and patients with glaucoma. The AngioVue Enhanced Microvascular Imaging System was used to capture the optic nerve head and macula images during one visit. En face segment images of the macular and optic disc were studied in layers. Microvascular density of the optic nerve head and macula were quantified by the number of pixels measured by a novel in-house developed software. Areas under the receiver operating characteristic curves (AUROC) were used to determine the accuracy of differentiating between glaucoma and healthy subjects.

    RESULTS: A total of 24 (32 eyes) glaucoma subjects (57.5±9.5-y old) and 29 (58 eyes) age-matched controls (51.17±13.5-y old) were recruited. Optic disc and macula scans were performed showing a greater mean vessel density (VD) in healthy compared with glaucoma subjects. The control group had higher VD than the glaucoma group at the en face segmented layers of the optic disc (optic nerve head: 0.209±0.05 vs. 0.110±0.048, P<0.001; vitreoretinal interface: 0.086±0.045 vs. 0.052±0.034, P=0.001; radial peripapillary capillary: 0.146±0.040 vs. 0.053±0.036, P<0.001; and choroid: 0.228±0.074 vs. 0.165±0.062, P<0.001). Similarly, the VD at the macula was also greater in controls than glaucoma patients (superficial retina capillary plexus: 0.115±0.016 vs. 0.088±0.027, P<0.001; deep retina capillary plexus: 0.233±0.027 vs. 0.136±0.073, P<0.001; outer retinal capillary plexus: 0.190±0.057 vs. 0.136±0.105, P=0.036; and choriocapillaris: 0.225±0.053 vs. 0.153±0.068, P<0.001. The AUROC was highest for optic disc radial peripapillary capillary (0.96), followed by nerve head (0.92) and optic disc choroid (0.76). At the macula, the AUROC was highest for deep retina (0.86), followed by choroid (0.84), superficial retina (0.81), and outer retina (0.72).

    CONCLUSIONS: Microvascular density of the optic disc and macula in glaucoma patients was reduced compared with healthy controls. VD of both optic disc and macula had a high diagnostic ability in differentiating healthy and glaucoma eyes.

    Matched MeSH terms: Fluorescein Angiography/methods
  15. Nayak SB, Shetty SD
    Surg Radiol Anat, 2021 Mar;43(3):413-416.
    PMID: 33231750 DOI: 10.1007/s00276-020-02619-z
    Knowledge of variations of the internal carotid artery is significant to surgeons and radiologists. The internal carotid artery normally runs a straight course in the neck. Its anomalies can lead to its iatrogenic injuries. We report a case of a large loop of the internal carotid artery in a male cadaver aged about 75 years. The common carotid artery terminated by dividing it into the external carotid artery and internal carotid arteries at the level of the upper border of the thyroid cartilage. From the level of origin, the internal carotid artery coursed upwards, backwards and laterally, and formed a large loop behind the internal jugular vein. The variation was found on the left side of the neck and was unilateral. The uncommon looping of the internal carotid artery might result in altered blood flow to the brain and may lead to misperceptions in surgical, imaging, and invasive procedures.
    Matched MeSH terms: Angiography/methods
  16. Alharazy SM, Kong N, Saidin R, Gafor AH, Maskon O, Mohd M, et al.
    Angiology, 2014 Mar;65(3):225-6.
    PMID: 23564021 DOI: 10.1177/0003319713483544
    Matched MeSH terms: Coronary Angiography/adverse effects*
  17. Leong BD, Chuah JA, Kumar VM, Mazri MY, Zainal AA
    Singapore Med J, 2008 Nov;49(11):e300-2.
    PMID: 19037533
    True and pseudoaneurysms of the visceral arteries are uncommon. They represent 0.1-0.2 percent of all vascular aneurysms. Visceral artery aneurysms (VAAs) should be treated due to their propensity to rupture and associated high mortality. We describe a 58-year-old man with pseudoaneurysm of the inferior pancreaticoduodenal artery and who presented with post-motor vehicle accident abdominal pain and a pulsatile epigastic mass. Computed tomography (CT) showed a pseudoaneurysm of the visceral artery, and selective mesenteric angiography showed the aneurysm to be arising from the inferior pancreaticoduodenal artery. The aneurysm was successfully treated with endovascular coil embolisation. CT angiogram at one month post-procedure revealed persistent occlusion of the aneurysm. To the best of our knowledge, this is the first reported pseudoaneurysm of inferior pancreaticoduodenal artery secondary to blunt abdominal trauma from a motor vehicle accident and also the first reported VAA from Malaysia.
    Matched MeSH terms: Angiography/methods
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links