METHODS: In this study, 52 healthy young adults were enrolled (mean age = 23.2 ± 0.8 years, 61.8% were males). They underwent the standard AR testing and ARL values were computed. Both ipsilateral and contralateral recordings were made at 500, 1000, 2000 and 4000 Hz frequencies.
RESULTS: The ARL values obtained are consistent with the findings from the previous studies. Two-way analysis of variance (ANOVA) revealed that the ARL values were not statistically influenced by either stimulation mode (p = 0.061) or stimulus frequency (p = 0.598).
CONCLUSION: Among young adults, ARL does not appear to be influenced by stimulation mode and stimulus frequency. Further large scale research is warranted to support the present study's findings. The preliminary normative data for ARL obtained in this study can serve as the reference for future research involving this particular population.
MATERIALS AND METHODS: In this repeated-measures study, 40 Malaysian adults (aged 19-26 years) with normal hearing bilaterally (based on PTA results) were enrolled. They then underwent the SAL test based on the recommended protocol by Jerger and Tillman (1960). The SAL normative data for each ear were obtained by calculating the differences between air conduction (AC) thresholds in quiet and AC thresholds in noise by means of insert earphone, B71 and B81 bone vibrators.
RESULTS: The SAL normative values were comparable between the ears (p > 0.05), and the data were pooled for subsequent analyses (n = 80 ears). Relative to B81 bone transducer, B71 bone vibrator produced statistically higher SAL normative data at all frequencies (p < 0.05). The SAL normative values established by the present study were statistically lower than those of the previous study (that utilised headphones) at most of frequencies tested (p < 0.05).
CONCLUSIONS: The SAL normative data produced by the two bone vibrators were significantly different. The SAL normative values were also affected by the type of earphone used. While conducting the SAL test on Malaysian patients, the information provided by this study can be useful to guide the respective clinicians in choosing the appropriate normative data.