METHODS: Patients with newly diagnosed AAC were identified prospectively over a 12-month period (November 2011 to October 2012) by active surveillance through the Scottish Ophthalmic Surveillance Unit reporting system. Data were collected at case identification and at 6 months follow-up.
RESULTS: There were 114 cases (108 patients) reported, giving an annual incidence of 2.2 cases (95% CI 1.8 to 2.6) or 2 patients (95% CI 1.7 to 2.4) per 1 00 000 in the whole population in Scotland. Precipitating factors were identified in 40% of cases. Almost one in five cases was associated with topical dilating drops. Best-corrected visual acuity (BCVA) at presentation ranged from 6/6 to perception of light. The mean presenting intraocular pressure (IOP) was 52 mm Hg (SD 11). Almost 30% cases had a delayed presentation of 3 or more days. At 6 months follow-up, 75% had BCVA of 6/12 or better and 30% were found to have glaucoma at follow-up. Delayed presentation (≥3 days) was associated with higher rate of glaucoma at follow-up (22.6% vs 60.8%, p<0.001), worse VA (0.34 vs 0.74 LogMAR, p<0.0001) and need for more topical medication (0.52 vs 1.2, p=0.003) to control IOP.
CONCLUSION: The incidence of AAC in Scotland is relatively low compared with the Far East countries, but in line with previous European data. Almost one in five cases were associated with pupil dilation for retinal examination.
MATERIALS AND METHODS: An e-mail invitation to participate in an online survey was sent to hospital laboratories in Malaysia (n=140). Questions regarding methods for measuring creatinine, equations for calculating eGFR, eGFR reporting, the terminology used in reporting urine albumin, types of samples and the cut-off values used for normal albuminuria.
RESULTS: A total of 42/140 (30%) laboratories answered the questionnaire. The prevalent method used for serum creatinine measurement was the Jaffé method (88.1%) traceable to isotope-dilution mass spectrometry. eGFR was reported along with serum creatinine by 61.9% of laboratories while 33.3% of laboratories report eGFR on request. The formula used for eGFR reporting was mainly MDRD (64.3%) and results were reported as exact numbers even when the eGFR was <60 ml/min/1.73m2. The term microalbumin is still used by 83.3% of laboratories. There is a large heterogeneity among the labs regarding the type of sample recommended for measuring urine albumin, reference interval and reporting units.
CONCLUSION: It is evident that the laboratory assessment of chronic kidney disease in Malaysia is not standardised. It is essential to provide a national framework for standardised reporting of eGFR and urine albumin. Recommendations developed by the MACB CKD Task Force, if adopted by all laboratories, will lead to a reduction in this variability.
MATERIALS AND METHODS: To determine the extent of variation in reporting of protein electrophoresis results questionnaires were distributed to the pathologists of various laboratories in Malaysia regarding the method, quantification of paraprotein concentrations and immunoglobulin assays, and information regarding current laboratory electrophoresis practices.
RESULTS: Variation was found in the following reporting practices: (a) screening protocol; (b) reporting of serum albumin; (c) numerical reporting of protein fractions and paraprotein; (d) co-migration of a paraprotein with a normal serum protein; (e) reporting of multiple paraprotein bands (f) appearance of small abnormal band and oligoclonal bands and (g) communication about of interferences.
CONCLUSION: The pathologists of the country made recommendations on the reporting of protein electrophoresis. Harmonised reporting will reduce inconsistency, variation in reporting, improve the quality of the report and most importantly improve patient care.
METHODS: Blood specimens were obtained from 92 malignant, 16 benign breast cancer patients and 23 healthy controls. The serum concentrations of sPD-L1 were assessed by enzyme-linked immunosorbent assay (ELISA).
RESULTS: The median serum sPD-L1 concentration of malignant and benign breast cancer patients was significantly elevated compared to the healthy cohorts (12.50 ng/mL vs 13.97 ng/mL vs 8.75 ng/mL, p