Displaying all 12 publications

Abstract:
Sort:
  1. Mohd Rohani MF, Amir Hassan SZ
    Clin Nucl Med, 2022 Jan 01;47(1):e20-e22.
    PMID: 34028418 DOI: 10.1097/RLU.0000000000003698
    A 57-year-old woman was referred for radioactive iodine therapy 12 weeks after completion thyroidectomy and left modified radical neck dissection for pT2N1Mx follicular variant papillary thyroid carcinoma. After 4 weeks of l-thyroxine withdrawal, stimulated serum thyroglobulin level was less than 0.1 ng/mL with positive thyroglobulin antibody. Posttherapy 131I scintigraphy with SPECT/CT of the head and abdominopelvic region showed thyroid residual in the neck, occipital bone metastasis, and heterogenous tracer uptake in a large peritoneal mass, likely arising from the left ovary. Left salpingo-oophorectomy was performed, and histopathologic examination revealed endometrioid carcinoma of left ovary.
  2. Maktabdar Oghaz M, Maarof MA, Zainal A, Rohani MF, Yaghoubyan SH
    PLoS One, 2015;10(8):e0134828.
    PMID: 26267377 DOI: 10.1371/journal.pone.0134828
    Color is one of the most prominent features of an image and used in many skin and face detection applications. Color space transformation is widely used by researchers to improve face and skin detection performance. Despite the substantial research efforts in this area, choosing a proper color space in terms of skin and face classification performance which can address issues like illumination variations, various camera characteristics and diversity in skin color tones has remained an open issue. This research proposes a new three-dimensional hybrid color space termed SKN by employing the Genetic Algorithm heuristic and Principal Component Analysis to find the optimal representation of human skin color in over seventeen existing color spaces. Genetic Algorithm heuristic is used to find the optimal color component combination setup in terms of skin detection accuracy while the Principal Component Analysis projects the optimal Genetic Algorithm solution to a less complex dimension. Pixel wise skin detection was used to evaluate the performance of the proposed color space. We have employed four classifiers including Random Forest, Naïve Bayes, Support Vector Machine and Multilayer Perceptron in order to generate the human skin color predictive model. The proposed color space was compared to some existing color spaces and shows superior results in terms of pixel-wise skin detection accuracy. Experimental results show that by using Random Forest classifier, the proposed SKN color space obtained an average F-score and True Positive Rate of 0.953 and False Positive Rate of 0.0482 which outperformed the existing color spaces in terms of pixel wise skin detection accuracy. The results also indicate that among the classifiers used in this study, Random Forest is the most suitable classifier for pixel wise skin detection applications.
  3. Tagiling N, Mohd-Rohani MF, Wan-Sohaimi WF, Faisham WI, Nawi NM
    Malays Orthop J, 2020 Nov;14(3):188-193.
    PMID: 33403085 DOI: 10.5704/MOJ.2011.032
    Megaprosthesis is used to restore the form and function of massive skeletal defects, but it is accompanied by risks of failure, mainly due to perimegaprosthetic infection (PMI). In practice, the diagnosis of infected megaprosthesis among patients with a high index of clinical suspicion, elevated serological markers, and multiple negative or inconclusive imaging can be very challenging and poses a diagnostic conundrum to many orthopaedic surgeons. We present the case of a symptomatic 26-year-old female with large B-cell lymphoma who developed cellulitis with suspected complication of PMI 15 months post-implantation. The combination of advanced nuclear medicine imaging strategies, i.e., 99mTc-besilesomab/99mTc-sulfur colloid scintigraphy with hybrid single-photon emission computed tomography/computed tomography (SPECT/CT) scanning helps to characterise and delineate both infections. Invasive procedures such as joint aspiration and biopsy were avoided, and the patient was successfully treated with antibiotics. Hence, we report a case where advanced imaging modalities were decisive in the investigation of PMI.
  4. Ghaleb FA, Kamat MB, Salleh M, Rohani MF, Abd Razak S
    PLoS One, 2018;13(11):e0207176.
    PMID: 30457996 DOI: 10.1371/journal.pone.0207176
    The presence of motion artefacts in ECG signals can cause misleading interpretation of cardiovascular status. Recently, reducing the motion artefact from ECG signal has gained the interest of many researchers. Due to the overlapping nature of the motion artefact with the ECG signal, it is difficult to reduce motion artefact without distorting the original ECG signal. However, the application of an adaptive noise canceler has shown that it is effective in reducing motion artefacts if the appropriate noise reference that is correlated with the noise in the ECG signal is available. Unfortunately, the noise reference is not always correlated with motion artefact. Consequently, filtering with such a noise reference may lead to contaminating the ECG signal. In this paper, a two-stage filtering motion artefact reduction algorithm is proposed. In the algorithm, two methods are proposed, each of which works in one stage. The weighted adaptive noise filtering method (WAF) is proposed for the first stage. The acceleration derivative is used as motion artefact reference and the Pearson correlation coefficient between acceleration and ECG signal is used as a weighting factor. In the second stage, a recursive Hampel filter-based estimation method (RHFBE) is proposed for estimating the ECG signal segments, based on the spatial correlation of the ECG segment component that is obtained from successive ECG signals. Real-World dataset is used to evaluate the effectiveness of the proposed methods compared to the conventional adaptive filter. The results show a promising enhancement in terms of reducing motion artefacts from the ECG signals recorded by a cost-effective single lead ECG sensor during several activities of different subjects.
  5. Wan Sohaimi WF, Lee YF, Mat Nawi N, Mohd Rohani MF, Sapiai NA
    Indian J Surg Oncol, 2019 Dec;10(4):676-678.
    PMID: 31857764 DOI: 10.1007/s13193-019-00977-8
    We report a unique case of differentiated thyroid carcinoma (DTC) with squamous metaplasia complicated with chronic discharging ulcer. A 76-year-old gentleman was referred to us after defaulted treatment 1 year post-total thyroidectomy. He presented to us with long-standing chronic, non-healing, ulcerative and discharging wound at the anterior neck at previous total thyroidectomy scar. The primary tumour was histologically diagnosed as papillary malignant cells with extensive squamous metaplasia. Squamous metaplasia is a rare finding in thyroid carcinoma that carried a poorer prognostic factor.
  6. Suppiah S, Mohd Rohani MF, Zanial AZ, Ahmad Shahrir AD, Khairuman KA, Vinjamuri S
    Indian J Nucl Med, 2023;38(2):191-200.
    PMID: 37456181 DOI: 10.4103/ijnm.ijnm_142_22
    Planar whole-body bone scanning (WBS) is widely used to evaluate skeletal lesions seen in cancer and noncancer cases. Frequently, degenerative, or other benign bony changes may give rise to indeterminate lesions that mimic bone metastases. In the post-COVID-19 era, there is an evolutionary phase that puts importance on global development and adaptability, which encompasses to include nuclear medicine practices worldwide. Single-photon emission computed tomography/computed tomography (SPECT/CT) can be used to improve the characterization of these lesions and help to resolve the diagnostic conundrum while reducing the need for patients to undergo multiple different examinations at various imaging departments. The fusion of SPECT and CT allows morphological characterization of functional abnormality detected by focal tracer uptake on planar scintigraphy, which provides a one-stop center imaging in nuclear medicine departments. The objective of this study was to review the diagnostic accuracy of SPECT/CT in diagnosing bone metastases in a variety of oncology and nononcology cases and to determine the feasibility of performing bone SPECT/CT in all suspected cancer cases, including cases of bone infection instead of planar imaging alone. The utilization of hybrid SPECT/CT in indeterminate bone lesions detected on planar WBS can significantly increase the diagnostic confidence and accuracy of image interpretation. Recognition of patterns of disease identified using hybrid imaging can improve the management of patients with potentially lower costs in the long term. Currently, hybrid SPECT/CT machines are becoming a norm in nuclear medicine departments, thus potentially making single planar application machines obsolete in the near future. We hypothesize that in the interest of providing a meaningful interpretation of isotope bone scans, the default protocol should involve the option of acquiring SPECT/CT images rather than relying on whole-body scans only. Departments choosing to upgrade existing equipment or those choosing to invest in only one gamma camera should proactively opt for hybrid SPECT/CT systems.
  7. Kamarulzaman K, Mohd Rohani MF, Mat Nawi N, Amir Hassan SZ
    Clin Nucl Med, 2024 Mar 01;49(3):250-252.
    PMID: 38306377 DOI: 10.1097/RLU.0000000000005037
    A 57-year-old woman received radioiodine therapy post total thyroidectomy for pT3aNxMx follicular thyroid carcinoma. Posttherapy 131I whole-body scan showed 131I concentration in the chest, mediastinum, and left upper thigh with stimulated thyroglobulin (Tg) of 89 μg/L. Subsequent radioiodine therapies showed persistent 131I accumulation in the anterior mediastinal soft tissue lesions and a hypodense segment VII liver lesion visualized on SPECT/CT, suggestive of iodine-avid metastatic disease despite the undetectable serum Tg (<1.0 μg/L) with no Tg antibody interference. Biopsy of the liver lesion revealed liver cyst, and consequent removal of the mediastinal lesions showed benign thymic cysts.
  8. Mohd Rohani MF, Bujang NL, Rosdi AH, Amir Hassan SZ
    Clin Nucl Med, 2024 Jan 01;49(1):e19-e21.
    PMID: 37883221 DOI: 10.1097/RLU.0000000000004941
    Superscan on PET/CT has been reported in the literature and mainly involved metastatic diseases. We report an uncommon case of a metabolic superscan on 18 F-FDG PET/CT in a 56-year-old man with end-stage renal disease on hemodialysis who presented with secondary hyperparathyroidism. Parathyroid scintigraphy showed 2 lesions posteroinferior to both thyroid lobes, suggestive of parathyroid adenoma/hyperplasia. FDG PET/CT performed to assess for pulmonary nodules revealed diffuse FDG hypermetabolism involving the visualized skull, mandible, spine, sternum, ribs, and appendicular skeleton without corresponding CT lesion with no urinary radiotracer excretion, consistent with metabolic superscan secondary to renal osteodystrophy.
  9. Mohd Rohani MF, Mat Nawi N, Shamim SE, Wan Sohaimi WF, Wan Zainon WMN, Musarudin M, et al.
    Ann Nucl Med, 2020 Jan;34(1):39-48.
    PMID: 31612417 DOI: 10.1007/s12149-019-01410-4
    OBJECTIVE: Qualitative interpretation in bone scan is often complicated by the presence of degenerative joint disease (DJD), especially in the elderly patient. The aim of this study is to compare objectively 99mTc-MDP tracer uptake between DJD and osseous metastases of the spine using semi-quantitative assessment with SPECT SUV.

    METHODS: Bone scan with SPECT/CT using 99mTc-MDP was performed in 34 patients diagnosed with prostate carcinoma. SPECT/CT was performed based on our institutional standard guidelines. SUVmax based on body weight in 238 normal vertebrae visualized on SPECT/CT was quantified as baseline. A total of 211 lesions in the spine were identified on bone scan. Lesions were characterized into DJD or bone metastases based on its morphology on low-dose CT. Semi-quantitative evaluation using SUVmax was then performed on 89 DJD and 122 metastatic bone lesions. As most of the bone lesions were small in volume, the effect of partial volume effect (PVE) on SUVmax was also assessed. The corrected SUVmax values were obtained based on the recovery coefficient (RC) method.

    RESULTS: The mean SUVmax for normal vertebrae was 7.08 ± 1.97, 12.59 ± 9.01 for DJD and 36.64 ± 24.84 for bone metastases. The SUVmax of bone metastases was significantly greater than DJD (p value 

  10. Mat Nawi N, Tagiling N, Mohd Rohani MF, Wan Zainon WMN, Zanial MS, Wong MS, et al.
    BMC Gastroenterol, 2020 Aug 31;20(1):293.
    PMID: 32867699 DOI: 10.1186/s12876-020-01426-5
    BACKGROUND: It is unclear if the 99mTc-sodium phytate (99mTc-SP) is as reliable as the gold-standard 99mTc-sulfur colloid (99mTc-SC) for gastric emptying scintigraphy (GES). This study is aimed to compare the emptying rates of both radiotracers in a prospective, randomized cross-over trial and to determine the normative data of a healthy multi-ethnic Asian population.

    METHODS: Out of the 44 healthy individuals screened, 31 (14 females; mean age: 28.4 ± 7.0 years) were enrolled and underwent GES using the standardized egg-white meal. All participants were randomly assigned to either 99mTc-SP or 99mTc-SC on the first GES session before crossed over to the other formulation after 2 weeks.

    RESULTS: Both kits achieved the radiochemical purities of > 95%. The median rate (95th upper normative limit) of gastric emptying, reported as total gastric meal retention between 99mTc-SP and 99mTc-SC, was found to be comparable at all measured time points: 0.5 h [85.0% (96.6%) vs. 82.0% (94.0%)], 1 h [70.0% (86.4%) vs. 65.0% (86.6%)], 2 h [31.0% (55.8%) vs. 25.0% (64.4%)], 3 h [7.0% (26.3%) vs. 5.0% (29.9%)], and 4 h [3.0% (10.3%) vs. 2.0% (9.9%)]; P > 0.05. In addition, both radiotracers correlated well (Kendall's Tau (τ) coefficient = 0.498, P 

  11. Mohd Rohani MF, Zanial AZ, Suppiah S, Phay Phay K, Mohamed Aslum Khan F, Mohamad Najib FH, et al.
    Nucl Med Commun, 2021 Jan;42(1):9-20.
    PMID: 33165258 DOI: 10.1097/MNM.0000000000001306
    Skeletal whole-body scintigraphy (WBS), although widely used as a sensitive tool for detecting metastatic bone disease in oncology cases, has relatively low specificity. Indeterminate bone lesions (IBLs) detected by WBS cause a diagnostic dilemma, which hampers further management plans. In the advent of hybrid imaging, single-photon emission computed tomography/computed tomography (SPECT/CT) has been gaining popularity as a tool to improve the characterisation of IBLs detected by WBS. As yet, there has not been a systematic review to objectively evaluate the diagnostic capabilities of SPECT/CT in this area. We conducted a systematic review of relevant electronic databases up to 30 August 2020. The outcomes of interest were the reporting of SPECT/CT to identify benign and malignant IBLs and the calculation of the sensitivity and specificity of the index test, based on histopathological examination or clinical and imaging follow-up as the reference standard. After the risk of bias and eligibility assessment, 12 articles were identified and synthesised in the meta-analysis. The pooled sensitivity and specificity of SPECT/CT for diagnosing IBLs are 93.0% [95% confidence interval (CI) 0.91-0.95] and 96.0% (95% CI 0.94-0.97), respectively. There was heterogeneity of the articles due to variable imaging protocols, duration of follow-up and scoring methods for interpreting the SPECT/CT results. The heterogeneity poses a challenge for accurate interpretation of the true diagnostic capability of SPECT/CT. In conclusion, targeted SPECT/CT improves the specificity of diagnosing bone metastases, but efforts need to be made to standardise the thresholds for SPECT/CT, methodology, as well as harmonising the reporting and interpretation criteria. We also make some recommendations for future works.
  12. Tagiling N, Ibrahim IL, Lee YY, Udin MY, Mohamad Kamarulzaman MD, Phoa PKA, et al.
    PMID: 38705971 DOI: 10.1111/jgh.16585
    BACKGROUND AND AIM: Measurements of gastric emptying and accommodation for alternative test-meal protocol during gastric emptying scintigraphy (GES), such as high-calorie nutrient drinks, are not fully established. We aimed to compare the effects of standardized egg-white meal (EWM) versus high-calorie nutrient drink (Vital®; Abbott Laboratories) on global GES parameters and intragastric meal distribution at immediate scan (IMD0h).

    METHODS: Of 84 screened participants, 60 asymptomatic healthy Asian population (38 females; 24.0 ± 1.5 years; 23.8 ± 2.6 kg/m2) were recruited in this 2 × 2 (AB/BA) crossover trial. Participants were randomized to a 4-h GES with 99mTc-radiolabeled EWM (~255.8 kcal), followed by a 200 mL Vital® (300 kcal), or vice versa, separated by a 2-week washout period. Global meal retention (GMR), power-exponential model emptying parameters (half-emptying [T1/2], lag phases [Tlag2%, Tlag5%, Tlag10%]), and IMD0h were determined and compared.

    RESULTS: GMRs for both test meals were within the international standard references for solid GES. Compared to EWM, Vital® exhibited significantly lower GMRs (faster emptying) from 0.5 to 3 h (all P 

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links