Displaying all 7 publications

Abstract:
Sort:
  1. Soni A, Kansay R, Gupta S, Malhotra A
    Malays Orthop J, 2019 Mar;13(1):57-59.
    PMID: 31001387 DOI: 10.5704/MOJ.1903.014
    Femoral condyle fracture in coronal plane, also known as Hoffa fracture, is a rare fracture. Non-union of Hoffa fracture is even rarer. We present a case of fibrous nonunion of a Hoffa fracture in which the fractured fragment, though not freely movable, led to painful walking. Since the fragment was un-displaced and non-movable we fixed the fractured fragment in situ. Patient regained full range of motion of the knee and was asymptomatic on follow-up.
  2. Gupta R, Singhal A, Malhotra A, Soni A, Masih GD, Raghav M
    Malays Orthop J, 2020 Nov;14(3):50-56.
    PMID: 33403062 DOI: 10.5704/MOJ.2011.009
    Introduction: Few authors have addressed risk factors related to an ipsilateral graft rupture and contralateral anterior cruciate ligament (ACL) injury after return to sports (RTS) following primary ACL reconstruction.

    Material and Methods: Patients with ACL re-injury to either knee after successful primary ACLR were included in Group I and those with no further re-injury were included in Group II. Variables including age, gender, side, body mass index (BMI), thigh atrophy, anterior knee laxity difference between both knees measured by KT-1000 arthrometer, mean time of return to sports (RTS), graft type, type of game, mode of injury, Tegner Activity Score, hormone levels, femoral tunnel length (FTL), posterior tibial slope (PTS) and notch width index (NWI) were studied. Binary logistic regression was used to measure the relative association.

    Results: A total of 128 athletes were included with 64 in each group. Mean age in Group I and II were 24.90 and 26.47 years respectively. Mean follow-up of Group I and Group II were 24.5 and 20.11 months respectively. Significant correlation was present between ACL re-injury and following risk factors; PTS of >10º, KT difference of >3.0mm, thigh atrophy of >2.50cm and time to RTS <9.50 months P value <0.05). No correlation was found with age, sex, BMI, type of game, Tegner Activity Score, mode of injury, NWI, size of graft, FTL and hormone levels.

    Conclusion: Possible risk factors include PTS of ≥ 10º, KT difference of ≥ 3.0mm at 1 year follow-up, thigh atrophy of ≥ 2.50cm at 1 year follow-up and RTS <9.5 months after primary ACLR.

  3. Soni A, Gupta RK, Raghav M, Masih GD, Bansal P
    Malays Orthop J, 2021 Jul;15(2):12-17.
    PMID: 34429817 DOI: 10.5704/MOJ.2107.003
    Introduction: Bone-patellar tendon-bone (BPTB) and semitendinosus-gracilis (STG) are the commonest grafts used for ACL reconstruction. However even after having been debated for years, there is no consensus about the ideal graft. Moreover, the literature is deficient about STG graft with preserved tibial insertion (STGPI) which preserves the proprioception. Our aim is to compare the outcome of BPTB, free STG and STGPI grafts after ACL reconstruction in professional sports persons. We compared the outcome in terms of mechanical stability, functional outcome, return to sports activity and degenerative changes.

    Material and Methods: Professional sports persons aged between 16-50 years operated for ACL tear using BPTB, free STG and STGPI grafts with minimum follow-up of two years were identified from hospital records. Patients with associated knee injuries were excluded. Patients, divided in three groups according to graft used, were compared in terms of mechanical stability (arthrometric examination KT-1000 score), functional outcome (Lysholm Score), return to sports activity (Tegner score and difference in thigh circumference) and degenerative changes (KL grading).

    Results: BPTB graft group was found to be better than free STG and STGPI graft groups in terms of KT-1000 score. There was no statistically significant difference among the groups in terms of Lysholm score, Tegner score, difference in thigh circumference and KL grading.

    Conclusion: BPTB graft is better than free STG and STGPI grafts in terms of knee stability. When compared for patient reported outcome, return to sports activity, osteoarthritic changes and graft failure there is no significant difference among the three types of grafts.

  4. Soni A, Das PK, Yusuf M, Kamyab H, Chelliapan S
    Sci Rep, 2022 Nov 07;12(1):18921.
    PMID: 36344577 DOI: 10.1038/s41598-022-19635-1
    Strict environmental concerns, depleting natural recourses, and rising demand for building construction materials have promoted scientific research toward alternative building materials. This research supports the idea of sustainability and a circular economy via the utilization of waste to produce value-added products. The research explored the potential of waste plastics and silica sand for developing thermoplastic composite as floor tiles. The samples were characterized by water absorption, compressive strength, flexural strength, and sliding wear. The morphological analysis of the sand-plastic interfaces was covered under the umbrella of this study. The maximum compressive and flexural strength were found to be 46.20 N/mm2 and 6.24 N/mm2, respectively, with the minimum water absorption and sliding wear rate of 0.039% and 0.143 × 10-8 kg/m, respectively. The study suggests the workability of the developed floor tiles in non-traffic areas of public places. Thus, the study provides a green building material through recycling waste plastics for sustainable development.
  5. Soni A, Das PK, Yusuf M, Pasha AA, Irshad K, Bourchak M
    Environ Sci Pollut Res Int, 2023 Dec;30(60):124566-124584.
    PMID: 35599290 DOI: 10.1007/s11356-022-20915-6
    The usage of waste for the development of sustainable building materials has received an increasing attention in socio-eco-environment spheres. The rice husk ash (RHA) produced during burning of rice husk and the ever-increasing plastic wastes are useless causing detrimental effects on the environment. This research supports the idea of sustainability and circular economy via utilization of waste to produce value-added products. This research explores the potential of waste plastics, RHA, and silica sand as thermoplastic composite materials. The different composite samples were prepared through waste plastics which includes low- and high-density polyethylene and polypropylene with incorporation of RHA and silica sand in proportions. The study investigates the effect of filler/polymer in 30/70, 20/80, and 10/90 (wt. %) on the workability of the developed composite materials. The workability of the composites was found to improve with filler reinforcement. The experimental results showed the maximum density of 1.676 g/cm3 and mechanical strength of 26.39, 4.89, and 3.25 MPa as compressive, flexural, and tensile strengths, respectively. The minimum percentage of water absorption was 0.052%. The wear tests resulted in a minimum abrasive and sliding wear rate of 0.03759 (cm3) and 0.00692 × 10-6 kg/m. The correlations between wear mechanisms and responses were morphologically analyzed. The developed composites verify the feasibility of RHA and plastics waste as a cost effective and environmentally competent product. The results and discussions provided a direction for the future research on sustainable polymeric composite materials.
  6. Soni A, Das PK, Yusuf M, Ridha S, Kamyab H, Alam MA, et al.
    Chemosphere, 2023 May;323:138233.
    PMID: 36863626 DOI: 10.1016/j.chemosphere.2023.138233
    The diverse nature of polymers with attractive properties has replaced the conventional materials with polymeric composites. The present study was sought to evaluate the wear performance of thermoplastic-based composites under the conditions of different loads and sliding speeds. In the present study, nine different composites were developed by using low-density polyethylene (LDPE), high-density polyethylene (HDPE) and polyethylene terephthalate (PET) with partial sand replacements i.e., 0, 30, 40, and 50 wt%. The abrasive wear was evaluated as per the ASTM G65 standard test for abrasive wear through a dry-sand rubber wheel apparatus under the applied loads of 34.335, 56.898, 68.719, 79.461 and 90.742 (N) and sliding speeds of 0.5388, 0.7184, 0.8980, 1.0776 and 1.4369 (m/s). The optimum density and compressive strength were obtained to be 2.0555 g/cm3 and 46.20 N/mm2, respectively for the composites HDPE60 and HDPE50 respectively. The minimum value of abrasive wear were found to 0.02498, 0.03430, 0.03095, 0.09020 and 0.03267 (cm3) under the considered loads of 34.335, 56.898, 68.719, 79.461 and 90.742 (N), respectively. Moreover, the composites LDPE50, LDPE100, LDPE100, LDPE50PET20 and LDPE60 showed a minimum abrasive wear of 0.03267, 0.05949, 0.05949, 0.03095 and 0.10292 at the sliding speeds of 0.5388, 0.7184, 0.8980, 1.0776 and 1.4369 (m/s), respectively. The wear response varied non-linearly with the conditions of loads and sliding speeds. Micro-cutting, plastic deformations, fiber peelings, etc. were included as the possible wear mechanism. The possible correlations between wear and mechanical properties, and throughout discussions for wear behaviors through the morphological analyses of the worn-out surfaces were provided.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links