Displaying publications 1 - 20 of 21 in total

Abstract:
Sort:
  1. Sia S, Shibazaki T, Koga Y, Yoshida N
    Am J Orthod Dentofacial Orthop, 2009 Jan;135(1):36-41.
    PMID: 19121498 DOI: 10.1016/j.ajodo.2007.01.034
    This study was designed to determine the optimum vertical height of the retraction force on the power arm that is required for efficient anterior tooth retraction during space closure with sliding mechanics.
  2. Aliaga Ramos J, Arantes V, Abdul Rani R, Yoshida N
    Endosc Int Open, 2020 Dec;8(12):E1741-E1747.
    PMID: 33269305 DOI: 10.1055/a-1265-6598
    Background and study aims  Submucosal (SM) injection is a critical step in endoscopic submucosal dissection (ESD). In Japan, use of viscous solutions such as sodium hyaluronate are recommended; the commercially product available is MucoUp (Seikagaku Co. and Boston Scientific Japan Co., Japan). Nevertheless, MucoUp is expensive and unavailable in many Western countries. For the past 8 years, we have been using low-cost sterile teardrops solution composed of 0.4 % sodium hyaluronate (Adaptis Fresh, Legrand Laboratory, Brazil). This solution is readily available in drugstores with a cost of approximately US$ 10.00 for each 10-cc bottle. The aim of this study was to present the clinical outcome with off-label sodium hyaluronate use for SM injection in gastric ESD. Patients and methods  A single-center retrospective study of collected data investigating consecutive patients that underwent gastric ESD between 2012 and 2019. ESD was performed using 0.4 % sodium hyaluronate teardrop for SM injection and Flush Knife BT 2.5 (Fujifilm Co., Japan). The following data were analyzed: clinical-pathological features, en-bloc, R0 and curative resection rate, procedure duration, adverse events, and clinical outcome. Results  ESD was performed with sodium hyaluronate for submucosal injection in 78 patients. The en-bloc resection rate and R0 resection rate were 96.1 % and 92.3 %, respectively. The curative resection rate for epithelial lesions was 83.8 %. Adverse events occurred in 5 cases (6.3 %): delayed bleeding (3.8 %, 3 cases) and perforation (2.5 %, 2 cases); all managed successfully by clipping and thermal coagulation. The mean volume of sodium hyaluronate solution used per patient was 10 cc (SD: ± 8 cc). During follow-up (mean: 17 months; SD: ± 14.5 months), two patients developed metachronous lesions (2.5 %). Conclusions  Off-label use of teardrops with 0.4 % sodium hyaluronate for submucosal injection was demonstrated to be safe and able to provide an effective submucosal cushion that facilitates SM dissection in gastric ESD procedures.
  3. Arantes V, Aliaga Ramos J, Abdul Rani R, Yoshida N
    Endosc Int Open, 2020 Dec;8(12):C3.
    PMID: 33304992 DOI: 10.1055/a-1328-0505
    [This corrects the article DOI: 10.1055/a-1265-6598.].
  4. Aliaga Ramos J, Yoshida N, Abdul Rani R, Arantes VN
    Arq Gastroenterol, 2023;60(2):208-216.
    PMID: 37556747 DOI: 10.1590/S0004-2803.20230222-168
    •This study aimed to assess the learning curve effect on patient's clinical outcome for EESD. Retrospective observational study, enrolling patients that underwent EESD from 2009 to 2021, divided in 2 groups. Mean procedure time was 111.8 min and 103.6 min for T1 and T2, respectively (P=0.004). The learning curve in esophageal ESD could be overcomed effectively and safely by an adequately trained Western endoscopist. Background - Esophageal endoscopic submucosal dissection (EESD) is a complex and time-consuming procedure at which training are mainly available in Japan. There is a paucity of data concerning the learning curve to master EESD by Western endoscopists. Objective - This study aimed to assess the learning curve effect on patient's clinical outcome for EESD. Methods - This is a retrospective observational study. Enrolling patients that underwent EESD from 2009 to 2021. The analysis was divided into two periods; T1: case 1 to 49 and T2: case 50 to 98. The following features were analyzed for each group: patients and tumors characteristics, en-bloc, complete and curative resection rates, procedure duration and adverse events rate. Results - Ninety-eight EESD procedures were performed. Mean procedure time was 111.8 min and 103.6 min for T1 and T2, respectively (P=0.004). En bloc resection rate was 93.8% and 97.9% for T1 and T2, respectively (P=0.307). Complete resection rate was 79.5% and 85.7% for T1 and T2, respectively (P=0.424). Curative resection rate was 65.3% and 71.4% for T1 and T2, respectively (P=0.258). Four patients had complications; three during T1 period and one during T2 period. Overall mortality rate: 0%. Conclusion - The esophageal endoscopic submucosal dissection could be performed effectively and safely by an adequately trained Western endoscopist.
  5. Ho QN, Hidaka T, Rahman MA, Yoshida N
    RSC Adv, 2024 Aug 16;14(36):26484-26493.
    PMID: 39175683 DOI: 10.1039/d4ra04672b
    Microbial fuel cells (MFCs) are a promising technology that directly converts organic matter (OM) in wastewater into electricity while simultaneously degrading contaminants. However, MFCs are insufficient for the removal of nitrogenous compounds. Therefore, the post-treatment of MFCs is essential. This study was the first to use natural zeolite adsorption integrated with photosynthesis (ZP) for post-treating MFCs. In this system, no external energy was required; instead, natural light was used to promote the growth of photosynthetic microorganisms, thereby enhancing contaminants removal through the photosynthesis process. To assess the effectiveness of the method, comparisons were conducted under two conditions: dark (no photosynthesis) and light (with photosynthesis). In darkness, extending hydraulic retention time (HRT) enhanced COD and BOD removal by 19.8% and 28.9%, respectively. When exposed to natural light, improvements were even more notable, with COD and BOD removal reaching 32% and 40%, respectively. In both conditions, the method effectively removed NH4 +, achieving 60% efficiency in darkness and 84.5% in light. This study showed that the adsorption capacity of the zeolite reached saturation when the cumulative liquid volume per unit weight of the zeolite exceeded 0.2 L g-1. The key functional photosynthetic microbes were investigated using 16S rRNA and 18S rRNA. This revealed the presence of microorganisms such as Chlorobium, Acidovorax, Novosphingobium, and Scenedesmus, which likely play a role in enhancing the efficiency of photosynthesis in removing contaminants. The study findings indicated that the integration of MFCs-ZP represents an eco-friendly approach capable of resource recovery from wastewater while also meeting discharge standards.
  6. Mohd Hassan FW, Muggundha Raoov, Kamaruzaman S, Sanagi MM, Yoshida N, Hirota Y, et al.
    J Sep Sci, 2018 Oct;41(19):3751-3763.
    PMID: 30125466 DOI: 10.1002/jssc.201800326
    This study describes a dispersive liquid-liquid microextraction combined with dispersive solid-phase extraction method based on phenyl-functionalized magnetic sorbent for the preconcentration of polycyclic aromatic hydrocarbons from environmental water, sugarcane juice, and tea samples prior to gas chromatography with mass spectrometry analysis. Several important parameters affecting the extraction efficiency were investigated thoroughly, including the mass of sorbent, type and volume of extraction solvent, extraction time, type of desorption solvent, desorption time, type and amount of salt-induced demulsifier, and sample volume. Under the optimized extraction and gas chromatography-mass spectrometric conditions, the method revealed good linearity (10-100000 ng/L) with coefficient of determination (R2 ) of ≥0.9951, low limits of detection (3-16 ng/L), high enrichment factors (61-239), and satisfactory analyte recoveries (86.3-109.1%) with the relative standard deviations n = 5). The entire sample preparation procedure was simple, rapid and can be accomplished within 10 min. This method was applied (after pretreatment) to 30 selected samples, and the presence of studied analytes was quantified in 17 samples.
  7. Yoshida N, Naito Y, Murakami T, Ogiso K, Hirose R, Inada Y, et al.
    Case Rep Gastroenterol, 2018 01 19;12(1):27-31.
    PMID: 29515342 DOI: 10.1159/000486128
    Cold snare polypectomy (CSP) should be performed for benign lesions, though an accurate diagnosis is sometimes difficult with only white light observation. Irregular findings by narrow-band imaging (NBI) are useful for differentiating malignant lesions from benign lesions, and cases with this finding are not expected for CSP. We present a diminutive T1 cancer resected by CSP as a reflection case. A 68-year-old man underwent colonoscopy for surveillance after polypectomy. A reddish polyp 4 mm in size was detected at the rectum. White light observation showed no depression, but a slight, heterogeneous color change. NBI magnification showed irregular vessel and surface patterns. The polyp was diagnosed as intramucosal cancer. Even though cancerous lesions are regularly resected by endoscopic mucosal resection (EMR), this polyp was resected by CSP in daycare surgery because the patient requested not to be treated by EMR but by CSP, which needed an admission to our institution. The surgeon thought the polyp could be completely resected by CSP. It was thoroughly resected, and a histological examination showed submucosal cancer with a positive vertical margin. Additional surgical resection was not accepted by the patient, since he had received total gastrectomy for gastric cancer and a right hemicolectomy for colonic cancer in the past 7 years. He underwent follow-up colonoscopy 2 months after the CSP. Although there were no recurrent endoscopic findings, endoscopic submucosal dissection was performed to the scar area. The histological examination showed no residual tumor. In conclusion, CSP should only be adopted for benign cases, as cancerous lesions have a possibility for invading the submucosa, like in our case.
  8. Aliaga Ramos J, Pedrosa MS, Yoshida N, Abdul Rani R, Arantes VN
    J Clin Gastroenterol, 2023 Jan 01;57(1):74-81.
    PMID: 33883515 DOI: 10.1097/MCG.0000000000001541
    BACKGROUND: The standard of practice when a superficial lesion was identified during upper GI endoscopy is to take an endoscopic forceps biopsy (EFB) of the lesion. The histopathologic findings then will determine the management plan. Endoscopic submucosal dissection (ESD) enables en-bloc resection for early neoplasms of the gastrointestinal tract and provides an adequate specimen that permits a more reliable histopathologic assessment. The objective of this study was to determine the rate of histopathologic discrepancy between EFB and specimens resected by ESD, and to identify the predisposing risk factors for this discordance.

    MATERIALS AND METHODS: This is a retrospective study, enrolling patients with superficial gastric neoplasms that underwent EFB followed by ESD. We divided cases to concordant or discordant group according to the histopathologic diagnosis of EFB and ESD specimens. We also analyzed the features that may have influenced the occurrence of histopathologic discordance and the association between discordant samples of adenocarcinoma and neoplastic invasion to deeper layers.

    RESULTS: A total of 115 gastric ESD procedures were performed with 84 patients meeting the inclusion criteria. Histopathologic discordance between EFB and ESD specimens were observed in 35.8% of cases (30/84 lesions). The univariant-bivariant analysis and multivariate logistic regression analysis showed that histologic discordance was closely related to the size of the lesions ( P =0.028).

    CONCLUSION: Histopathologic discrepancy between EFB and ESD specimens may occur in approximately one-third of cases, particularly for lesions over 20 mm, which may lead to crucial delays in gastric cancer precise diagnosis and treatment.

  9. Nor NAM, Tanaka F, Yoshida N, Jaafar J, Zailani MZ, Ahmad SNA
    Bioelectrochemistry, 2024 Jun 27;160:108770.
    PMID: 38943780 DOI: 10.1016/j.bioelechem.2024.108770
    This study assessed the viability of an anion-exchange microbial fuel cell (MFC) for extracting electricity from palm oil mill effluent (POME), a major pollutant in palm-oil producing regions due to increasing demand. The MFC incorporated a tubular membrane electrode assembly (MEA) with an air core, featuring a carbon-painted carbon-cloth cathode, an anion exchange membrane (AEM), and a nonwoven graphite fabric (NWGF) anode. An additional carbon brush (CB) anode was placed adjacent to the tubular MEA. The MFC operated under semi-batch conditions with POME replacement every 7 days. Results showed superior performance of the AEM, with the highest power density (Pmax) observed in POME-treated MFCs. Current and power density increased with CB addition; the best chemical oxygen demand (COD) removal efficiency reached 73 %, decreasing from 1249 to 332 mg/L with three CBs. The Pmax was 0.18 W/m-2(-|-) with 1000 mg/L COD and three CBs, dropping to 0.0031 W/m-2(-|-) without CB and at 410 mg/L COD. Anode resistance, calculated using organic matter supplementation, COD, and anode surface area, decreased with increased COD or surface area, improving electricity production. AEM and CB compatibility synergistically enhanced MFC performance, offering potential for POME wastewater treatment and energy recovery.
  10. Yoshida N, Naito Y, Murakami T, Hirose R, Ogiso K, Inada Y, et al.
    Ann Transl Med, 2017 Apr;5(8):185.
    PMID: 28616400 DOI: 10.21037/atm.2017.03.33
    In Japan, endoscopic submucosal dissection (ESD) becomes one of standard therapies for large colorectal tumors. Recently, the efficacy of ESD has been reported all over the world. However, it is still difficult even for Japanese experts in some situations. Right-sided location, large tumor size, high degree of fibrosis, difficult manipulation is related with the difficulty. However, improvements on ESD devices, suitable strategies, and increase of operators' experiences enable us to solve these problems. In this chapter, we introduce recent topics about various difficult factors of colorectal ESD and the tips such as strategy, devices, injection, and traction method [Pocket-creation method (PCM) etc.].
  11. Nasir ANM, Yahaya N, Zain NNM, Lim V, Kamaruzaman S, Saad B, et al.
    Food Chem, 2019 Mar 15;276:458-466.
    PMID: 30409620 DOI: 10.1016/j.foodchem.2018.10.044
    Thiol-functionalized magnetic carbon nanotubes (TMCNTs) were employed as the sorbent in the magnetic micro-solid phase extraction (M-µ-SPE) of sulfonamide antibiotics (SAs) in water, milks and chicken meat products prior to high performance liquid chromatography-diode array detector (HPLC-DAD) analysis. The synthesized sorbent was characterized by several spectroscopic techniques. Optimum conditions were: 20 mg of TMCNTs at pH 4, 2 min extraction time, 10% addition of salt and 30 mL of sample volume. Under the optimized TMCNTs-M-µ-SPE and HPLC-DAD conditions, the method showed good linearity in the range of 0.1-500 µg L-1 (r2 ≥ 0.9950), low limits of detection (0.02-1.5 µg L-1), good analytes recovery (80.7-116.2%) and acceptable RSDs (0.3-7.7%, n = 15). The method was applied to tap water (1), milks (15) and commercial chicken meat products (35), SAs were detected in five chicken meat samples (3.0-25.7 µg L-1). The method is critically compared to those reported in the literature.
  12. Yoshida N, Naito Y, Yasuda R, Murakami T, Ogiso K, Hirose R, et al.
    Endosc Int Open, 2017 12;5(12):C6.
    PMID: 29620079 DOI: 10.1055/a-0587-5955
    [This corrects the article DOI: 10.1055/s-0043-120659.].
  13. Yoshida N, Inoue K, Yasuda R, Hirose R, Dohi O, Naito Y, et al.
    Dig Dis Sci, 2018 12;63(12):3457-3464.
    PMID: 30232637 DOI: 10.1007/s10620-018-5275-1
    INTRODUCTION: Previous narrow-band imaging (NBI) was dark and reported not to be useful for polyp detection. In this study, we analyzed the efficacy of an additional 30-s observation of the right-sided colon with the recent bright high-resolution NBI.

    METHODS: We enrolled patients undergoing colonoscopy from February 2015 to May 2017 in two institutions. All procedures were performed with the latest system (EVIS LUCERA ELITE, Olympus). The cecum and ascending colon were first observed with white light imaging (WLI) in both the NBI and WLI group. Then, the colonoscope was re-inserted, and the cecum and ascending colon were observed for an additional 30 s. In this second observation, NBI was performed for the first 130 patients in the NBI group and WLI for the next 130 in the WLI group. The number of adenoma and sessile serrated polyps (ASPs) in the second observation were examined in both groups. According to our initial pilot study, the sample size was estimated at 126.

    RESULTS: In the first observation, the number of ASPs was 72 in the NBI group and 72 in the WLI group (p = 1.0). In the second observation, the number of ASPs was 23 in the NBI group and 10 in the WLI group (p = 0.02). The polyp and adenoma detection rates in the second observation were 16.2% and 12.3% in the NBI group and 7.7% (p = 0.03) and 6.2% (p = 0.09) in the WLI group.

    CONCLUSIONS: The additional 30-s observation with recent NBI decreased missed polyps in the right-sided colon.

  14. Yoshida N, Hirose R, Watanabe M, Yamazaki M, Hashimoto S, Matsubara S, et al.
    JGH Open, 2021 Jan;5(1):160-162.
    PMID: 33490630 DOI: 10.1002/jgh3.12435
    COVID-19 rarely causes lower gastrointestinal bleeding even though its RNA has been detected in patient's stool. Urgent colonoscopy in a COVID-19 patient with massive bloody stool requires various procedural and equipment considerations. Here, we present a case of colonoscopic hemostasis of a cecal hemorrhagic ulceration in a patient on heparin for COVID-19 coagulopathy. We also share various management methods for the prevention of COVID-19 contamination. A 71-year-old man was diagnosed with COVID-19 pneumonia and subsequently underwent hemodiafiltration. Heparin was initiated for COVID-19 coagulopathy. At day 42, the patient experienced 2000 mL of bloody stool. An operator performed urgent colonoscopy with three assistants in a negative-pressure room with full personal protective equipment. A hemorrhagic ulceration was detected at the cecum, and endoscopic hemostasis was performed. Immunohistochemistry was positive for cytomegalovirus. Postprocedure, the endoscopic systems were thoroughly cleaned, and specific measures for endoscope reprocessing and disinfection were performed to prevent contamination with COVID-19.
  15. Yoshida N, Naito Y, Yasuda R, Murakami T, Hirose R, Ogiso K, et al.
    Int J Colorectal Dis, 2017 Sep;32(9):1253-1260.
    PMID: 28725959 DOI: 10.1007/s00384-017-2855-z
    PURPOSE: Linked color imaging (LCI) by laser endoscopy is a novel narrow band light observation. In this study, we analyzed the efficacy of LCI for improving the various featured colorectal polyp's visibility utilizing a subjective endoscopist's visibility scoring and objective color difference (CD) value.

    METHODS: We retrospectively reviewed two pictures both with white light (WL) and LCI for 54 consecutive neoplastic polyps 2-20 mm in size. All pictures were evaluated by four endoscopists according to a published polyp visibility score from four (excellent visibility) to one (poor visibility). Additionally, we calculated CD value between each polyp and surrounding mucosa in LCI and WL using an original software.

    RESULTS: The mean polyp visibility scores of LCI (3.11 ± 1.05) were significantly higher than those of WL (2.50 ± 1.09, P 

  16. Yoshida N, Naito Y, Yasuda R, Murakami T, Hirose R, Ogiso K, et al.
    Endosc Int Open, 2018 Aug;6(8):E975-E983.
    PMID: 30083587 DOI: 10.1055/a-0593-5818
    Background and study aims:  Severe fibrosis poses a challenge in colorectal endoscopic submucosal dissection (ESD). Recently, the pocket-creation method (PCM) has been developed for overcoming various difficulties of ESD. A specific tapered hood is used for adequate traction in the PCM, and endoscopic operability becomes stable in the pocket. In this study, we investigated the efficacy of the PCM in ESD for cases with severe fibrosis.

    Patients and methods : We retrospectively reviewed 1000 consecutive colorectal ESD cases (April 2006 to January 2017). Since 2016, the PCM was performed in 58 cases. The indications for ESD included (1) tumors ≥ 20 mm in size diagnosed as intramucosal cancer or high-grade dysplasia and part of T1a cancer using magnifying endoscopic examinations and (2) tumors that appeared impossible to resect with endoscopic mucosal resection because of suspected fibrosis. We identified 120 cases with severe fibrosis and compared them to cases without severe fibrosis. Additionally, the 120 severe fibrosis cases were divided into the PCM and non-PCM groups. En bloc resection, procedure time, discontinuation, and complications were analyzed between these 2 groups.

    Results:  Among all 1000 ESDs, severe fibrosis and discontinuation rates were 12.0 % (120 cases) and 1.8 % (18 cases), respectively. Regarding the comparison between cases with severe fibrosis and with no severe fibrosis, there were significant differences about en bloc resection rate (78.3 % vs. 95.7 %, P   0.6.

    Conclusions:  In cases with severe fibrosis, the PCM with ESD improved en bloc resection rates and shortened the procedure time compared to the conventional non-PCM method. Additionally, the PCM reduced the discontinuation rate.

  17. Yoshida N, Dohi O, Inoue K, Yasuda R, Murakami T, Hirose R, et al.
    Gut Liver, 2019 03 15;13(2):140-148.
    PMID: 30513568 DOI: 10.5009/gnl18276
    A laser endoscopy system was developed in 2012. The system allows blue laser imaging (BLI), BLI-bright, and linked color imaging (LCI) to be performed as modes of narrow-band light observation; these modes have been reported to be useful for tumor detection and characterization. Furthermore, an innovative endoscopy system using four-light emitting diode (LED) multilight technology was released in 2016 to 2017 in some areas in which laser endoscopes have not been approved for use, including the United States and Europe. This system enables blue light imaging (this is also known as BLI) and LCI with an LED light source instead of a laser light source. Several reports have shown that these modes have improved tumor detection. In this paper, we review the efficacy of BLI and LCI with laser and LED endoscopes in tumor detection and characterization.
  18. Yoshida N, Fukumoto K, Hasegawa D, Inagaki Y, Inoue K, Hirose R, et al.
    J Gastroenterol Hepatol, 2021 Dec;36(12):3337-3344.
    PMID: 34260116 DOI: 10.1111/jgh.15625
    BACKGROUND AND AIM: High-grade dysplasia (HGD) and T1 lesions are accidentally resected by cold snare polypectomy (CSP) and the characteristics, and follow-up of them has not been reported. In this study, we analyzed the histopathological findings and recurrence of them.

    METHODS: This was a multicenter retrospective-cohort study. We collected HGD and T1 lesions of ≤ 10 mm resected by CSP among 15 520 patients receiving CSP from 2014 to 2019 at nine related institutions, and we extracted only cases receiving definite follow-up colonoscopy after CSP of HGD and T1 lesions. We analyzed these tumor's characteristics and therapeutic results such as R0 resection and local recurrence and risk factors of recurrence.

    RESULTS: We collected 103 patients (0.63%) and extracted 80 lesions in 74 patients receiving follow-up colonoscopy for CSP scar. Mean age was 68.4 ± 12.0, and male rate was 68.9% (51/80). The mean tumor size (mm) was 6.6 ± 2.5, and the rate of polypoid morphology and rectum location was 77.5% and 25.0%. The rate of magnified observation was 53.8%. The rates of en bloc resection and R0 resection were 92.5% and 37.5%. The local recurrence rate was 6.3% (5/80, median follow-up period: 24.0 months). The recurrence developed within 3 months after CSP for four out of five recurrent cases. Comparing five recurrent lesions to 75 non-recurrent lesions, a positive horizontal margin was a significant risk factor (60.0% vs 10.7%, P 

  19. Yoshida N, Naito Y, Yasuda R, Murakami T, Ogiso K, Hirose R, et al.
    Endosc Int Open, 2017 Dec;5(12):E1235-E1241.
    PMID: 29218315 DOI: 10.1055/s-0043-120659
    Background and study aims:  Water drop adhesions (WDA) impair endoscopic view during gastrointestinal endoscopy. We developed a novel lens cleaner designed using two types of harmLess surfactants and it is reported to be useful for preventing lens cloudiness during colorectal ESD. In the current study, we examined the ability of it for preventing and removing WDA.

    Patients and methods:  During laboratory experiments, the cleaner (Cleash; Fujifilm Co., Tokyo, Japan and Nagase Medicals Co., Hyogo, Japan) was applied to the endoscopic lens and an air/water device (AWD) (water 200 mL, dimethicone 1 mL, Cleash 1 mL). The endoscope was submerged in water 100 times for 5 cycles. Rates of WDA were calculated for various groups (lens and AWD with or without Cleash) and compared to a normal cleaner (SL cleaner). During clinical research, 30 colonoscopies and 30 esophagogastroduodenoscopies were analyzed. For the Cleash group, the cleaner was applied to both lens and AWD. The numbers of WDA and WDA with non-rapid removal were calculated, compared to those of the SL cleaner group.

    Results:  The mean WDA rate for the Cleash setting (lens: Cleash; AWD: Cleash) was 11.0 %, which was significantly lower than other settings (lens: SL cleaner; AWD: water, 31.0 %;P 

  20. Tomie A, Yoshida N, Kugai M, Hirose R, Dohi O, Inoue K, et al.
    Gastroenterol Res Pract, 2020;2020:9656040.
    PMID: 32411210 DOI: 10.1155/2020/9656040
    Materials and Methods: This was a multicenter retrospective cohort study. The subjects were patients aged ≥20 years treated for chronic constipation from May 2018 to November 2019 at 12 related institutions. Patients were divided into ≤74 years and ≥75 years old. Elobixibat at 10 mg/day was prescribed for two weeks. We then analyzed the discontinuation due to ineffectiveness, change of spontaneous bowel movements (SBM), stool consistency, the time until the first SBM, adverse events, and effect-related factors.

    Results: There were 140 cases (61 males) evaluated, with an average age of 72.1 ± 13.6 years (≤74 years: 71 cases; ≥75 years: 69 cases). The discontinuation rate was 7.9%. The SBM (times/week) increased from 2.86 to 6.08 (p < 0.001). The overall SBM improvement rate was 74.0% (≤74 years: 78.2% vs. ≥75 years: 68.9%, p = 0.31; male: 75.0% vs. female: 73.3%, p = 0.78). The overall improvement rate of stool consistency was 59.6% (≤74 years: 62.9%, ≥75 years: 56.1%, p = 0.42). The time until the first SBM (hours) for those ≤74 years and ≥75 years was 17.2 ± 14.3 and 11.2 ± 8.4 (p = 0.04). Adverse event rates for those ≤74 years and ≥75 years were 28.2% and 10.1% (p < 0.01). There were no significant effect-related factors for gender, age, and use of laxatives.

    Conclusions: Short-period elobixibat is shown to be effective also for the elderly and male.

Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links