METHODS: A cross-sectional study was conducted among 134 geriatric patients with a mean age of 68.9 ± 8.4 who stayed at acute care wards in Hospital Tuanku Ampuan Rahimah, Klang from July 2017 to August 2017. The SGA, MNA, and GNRI were administered through face-to-face interviews with all the participants who gave their consent. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the GNRI and MNA were analyzed against the SGA. Receiver-operating characteristic (ROC) curve analysis was used to obtain the area under the curve (AUC) and suitable optimal cutoff values for both the GNRI and MNA.
RESULTS: According to the SGA, MNA, and GNRI, 26.9%, 42.5%, and 44.0% of the participants were malnourished, respectively. The sensitivity, specificity, PPV, and NPV for the GNRI were 0.622, 0.977, 0.982, and 0.558, respectively, while those for the MNA were 0.611, 0.909, 0.932, and 0.533, respectively. The AUC of the GNRI was comparable to that of the MNA (0.831 and 0.898, respectively). Moreover, the optimal malnutrition cutoff value for the GNRI was 94.95.
CONCLUSIONS: The prevalence of malnutrition remains high among hospitalized elderly patients. Validity of the GNRI is comparable to that of the MNA, and use of the GNRI to assess the nutritional status of this group is proposed with the new suggested cutoff value (GNRI ≤ 94.95), as it is simpler and more efficient. Underdiagnosis of malnutrition can be prevented, possibly reducing the prevalence of malnourished hospitalized elderly patients and improving the quality of the nutritional care process practiced in Malaysia.
AIM: To analyze the existing literature on the effects of TRE with different eating durations on anthropometrics and cardiometabolic health markers in adults with excessive weight and obesity-related metabolic diseases.
METHODS: We reviewed a series of prominent scientific databases, including Medline, Scopus, Web of Science, Academic Search Complete, and Cochrane Library articles to identify published clinical trials on daily TRE in adults with excessive weight and obesity-related metabolic diseases. Randomized controlled trials were assessed for methodological rigor and risk of bias using version 2 of the Cochrane risk-of-bias tool for randomized trials (RoB-2). Outcomes of interest include body weight, waist circumference, fat mass, lean body mass, fasting glucose, insulin, HbA1c, homeostasis model assessment for insulin resistance (HOMA-IR), lipid profiles, C-reactive protein, blood pressure, and heart rate.
RESULTS: Fifteen studies were included in our systematic review. TRE significantly reduces body weight, waist circumference, fat mass, lean body mass, blood glucose, insulin, and triglyceride. However, no significant changes were observed in HbA1c, HOMA-IR, total cholesterol, low-density lipoprotein cholesterol, high-density lipoprotein cholesterol, heart rate, systolic and diastolic blood pressure. Furthermore, subgroup analyses based on the duration of the eating window revealed significant variation in the effects of TRE intervention depending on the length of the eating window.
CONCLUSION: TRE is a promising chrononutrition-based dietary approach for improving anthropometric and cardiometabolic health. However, further clinical trials are needed to determine the optimal eating duration in TRE intervention for cardiovascular disease prevention.
DESIGN: This was a single-center prospective observational study that compared resting energy expenditure estimated by 15 commonly used predictive equations against resting energy expenditure measured by indirect calorimetry at different phases. Degree of agreement between resting energy expenditure calculated by predictive equations and resting energy expenditure measured by indirect calorimetry was analyzed using intraclass correlation coefficient and Bland-Altman analyses. Resting energy expenditure values calculated from predictive equations differing by ± 10% from resting energy expenditure measured by indirect calorimetry was used to assess accuracy. A score ranking method was developed to determine the best predictive equations.
SETTING: General Intensive Care Unit, University of Malaya Medical Centre.
PATIENTS: Mechanically ventilated critically ill patients.
INTERVENTIONS: None.
MEASUREMENTS AND MAIN RESULTS: Indirect calorimetry was measured thrice during acute, late, and chronic phases among 305, 180, and 91 ICU patients, respectively. There were significant differences (F= 3.447; p = 0.034) in mean resting energy expenditure measured by indirect calorimetry among the three phases. Pairwise comparison showed mean resting energy expenditure measured by indirect calorimetry in late phase (1,878 ± 517 kcal) was significantly higher than during acute phase (1,765 ± 456 kcal) (p = 0.037). The predictive equations with the best agreement and accuracy for acute phase was Swinamer (1990), for late phase was Brandi (1999) and Swinamer (1990), and for chronic phase was Swinamer (1990). None of the resting energy expenditure calculated from predictive equations showed very good agreement or accuracy.
CONCLUSIONS: Predictive equations tend to either over- or underestimate resting energy expenditure at different phases. Predictive equations with "dynamic" variables and respiratory data had better agreement with resting energy expenditure measured by indirect calorimetry compared with predictive equations developed for healthy adults or predictive equations based on "static" variables. Although none of the resting energy expenditure calculated from predictive equations had very good agreement, Swinamer (1990) appears to provide relatively good agreement across three phases and could be used to predict resting energy expenditure when indirect calorimetry is not available.
METHODS: Using indirect calorimetry, REE was measured at acute (≤5 days; n = 294) and late (≥6 days; n = 180) phases of intensive care unit admission. PEs were developed by multiple linear regression. A multi-fold cross-validation approach was used to validate the PEs. The best PEs were selected based on the highest coefficient of determination (R2), the lowest root mean square error (RMSE) and the lowest standard error of estimate (SEE). Two PEs developed from paired 168-patient data were compared with measured REE using mean absolute percentage difference.
RESULTS: Mean absolute percentage difference between predicted and measured REE was <20%, which is not clinically significant. Thus, a single PE was developed and validated from data of the larger sample size measured in the acute phase. The best PE for REE (kcal/day) was 891.6(Height) + 9.0(Weight) + 39.7(Minute Ventilation)-5.6(Age) - 354, with R2 = 0.442, RMSE = 348.3, SEE = 325.6 and mean absolute percentage difference with measured REE was: 15.1 ± 14.2% [acute], 15.0 ± 13.1% [late].
CONCLUSIONS: Separate PEs for acute and late phases may not be necessary. Thus, we have developed and validated a PE from acute phase data and demonstrated that it can provide optimal estimates of REE for patients in both acute and late phases.
TRIAL REGISTRATION: ClinicalTrials.gov NCT03319329.
METHODS: From June 2015 to Jan 2018, a total of 4,603 adults were enrolled from 628 communities in 18 countries and 7 regions of the world. Each participant performed concurrent measurements from the MicroGP and EasyOne spirometer. Measurements were compared by the intra-class correlation coefficient (ICC) and Bland-Altman method.
RESULTS: Approximately 65% of the participants achieved clinically acceptable quality measurements. Overall correlations between paired FEV1 (ICC 0.88 [95% CI 0.87, 0.88]) and FVC (ICC 0.84 [0.83, 0.85]) were high. Mean differences between paired FEV1 (-0.038 L [-0.053, -0.023]) and FVC (0.033 L [0.012, 0.054]) were small. The 95% limits of agreement were wide but unbiased (FEV1 984, -1060; FVC 1460, -1394). Similar findings were observed across regions. The source of variation between spirometers was mainly at the participant level. Older age, higher body mass index, tobacco smoking and known COPD/asthma did not adversely impact on the inter-device variability. Furthermore, there were small and acceptable mean differences between paired FEV1 and FVC z-scores using the Global Lung Initiative normative values, suggesting minimal impact on lung function interpretation.
CONCLUSIONS: In this multicenter, diverse community-based cohort study, measurements from two portable spirometers provided good correlation, small and unbiased differences between measurements. These data support their interchangeable use across diverse populations to provide accurate trends in serial lung function measurements in epidemiological studies.