METHODS: This single-center, cross-sectional study conducted at the Paediatric Emergency Department from 1 October 2022, to 31 January 2023, included children aged 4 years and older with ARTIs symptoms and excluded those who were COVID-19 positive. B. pertussis was detected via quantitative Polymerase Chain Reaction on nasopharyngeal swabs and pertussis toxin (PT) IgG enzyme-linked immunosorbent assay.
RESULTS: Children (n = 298) with a median (Interquartile range, [IQR]) age of 6.0 (5.0, 8.0) years old were recruited, and 98% were vaccinated adequately. Two cases of B. pertussis (n = 2/298, 0.67%) were detected. Both children were also co-infected with Bordetella spp. The majority of the patients (n = 246/296, 83.1%) had low protective antibodies against pertussis (anti-PT IgG <5 IU/ml), and children 5 years and older were more likely to have lower anti-PT Ig G levels of <5 IU/ml (odds ratio 2.02 [95% CI 1.04,3.90]) compared to children 4 years old.
CONCLUSION: The prevalence of pertussis was low. However, there is significant waning immunity. Booster doses of pertussis vaccine should be given to all school-aged children.
METHODS: A total of 50 serum samples were collected from patients clinically suspected for acute leptospirosis on admission in the Hospital Serdang, from June 2016 to June 2017. All the samples were subjected to MAT, lipL32 PCR and the two rapid tests (Leptocheck-WB and ImmuneMed Leptospira IgM Duo Rapid test).
RESULTS: Out of the 50 clinically suspected patients sampled, 19 were confirmed positive for leptospirosis. Six (12%) were confirmed by MAT and 13 (26%) by PCR. Similarly, of the 50 clinically suspected cases, 17 (34%) showed positivity for Leptocheck-WB and 7 (14%) for ImmuneMed Leptospira IgM Duo Rapid test. The overall sensitivity and specificity was 47.37% and 80.65% for Leptocheck-WB, and 21.05% and 90.32% for ImmuneMed Leptospira IgM Duo Rapid test. In another set of previously confirmed MAT positive samples (1:400-1:3600) obtained from a reference laboratory, Leptocheck-WB showed higher sensitivity (90.72%) than ImmuneMed Leptospira IgM Duo Rapid test (40.21%), and comparable specificity for ImmuneMed Leptospira IgM Duo Rapid test (88.89%) and Leptocheck-WB (82.86%).
CONCLUSION: The sensitivity was higher for Leptocheck-WB and had a comparable specificity with ImmuneMed Leptospira IgM Duo Rapid test. Therefore, based on the present study, Leptocheck-WB is found to be a more sensitive rapid immunodiagnostic test for acute leptospirosis screening in hospital settings.