This paper uses wavelets in the detection comparison of breast cancer among the three main races in Malaysia: Chinese, Malays, and Indians followed by a system that evaluates the radiologist's findings over a period of time to gauge the radiologist's skills in confirming breast cancer cases. The db4 wavelet has been utilized to detect microcalcifications in mammogram-digitized images obtained from Malaysian women sample. The wavelet filter's detection evaluation was done by visual inspection by an expert radiologist to confirm the detection results of those pixels that corresponded to microcalcifications. Detection was counted if the wavelet-detected pixels corresponded to the radiologist's identified microcalcification pixels. After the radiologist's detection confirmation a new client-server radiologist recording and evaluation system is designed to evaluate the findings of the radiologist over some period of cancer detection working time. It is a system that records the findings of the Malaysian radiologist for the presence of breast cancer in Malaysian patients and provides a way of registering the progress of detecting breast cancer of the radiologist by tracking certain metric values such as the sensitivity, specificity, and receiver operator curve (ROC). The initial findings suggest that no single race mammograms are easier for wavelets' detections of microcalcifications and for the radiologist confirmation even though for this study the Chinese race samples detection average were a few percentages less than the other two races, namely the Malay and Indian races.
We present a case of rare pitfall in the diagnosis of an oesophageal foreign body due to the calcified vertical plate of the cricoid to highlight the need to be aware of this entity to avoid unnecessary morbidity.
The new 64-row multidetector computed tomography (CT)-assisted angiography can now detect coronary artery disease with shorter breath-hold time and at faster heart rates for symptomatic patients. We aim to determine if the 64-row scanner can also overcome limitations due to mild to moderate calcification.
X-ray microradiography of surgically excised breast specimens offers the possibility of morphological characterization of calcifications. When combined with digital imaging techniques there exists added potential for obtaining valuable basic quantitative morphometric information regarding differences between microcalcifications in tissues exhibiting evidence of fibrocystic change, benign and malignant tumours. A total of 157 excised breast specimens from 84 patients were microradiographed using a Softex Super Soft X-ray unit and Kodak AA high resolution industrial film. A Quantimet 570C image analysis system was used to digitize and analyse the microradiographs. Of the 157 microradiographs, 51 (from 30 patients) revealed microcalcification clusters. The existence of significant differences between the three identified categories of tissue were indicated by clustering parameters. These included the number of particles per cluster, area of clusters, maximum distance to nearest neighbour, and geometric mean distance to nearest neighbour. The distribution pattern index (DPI), another of the clustering parameters used in this study, has been observed to be a particularly powerful discriminator. The value for fibrocystic change was found to be significantly smaller (0.514) than that for benign tumour (0.796) whilst that for benign tumour was observed to be significantly larger than that for malignant tumour (0.604) at a p-value of less than 0.05 (Kruskal-Wallis one-way analysis of variance).
To assess the importance of Computed Tomography(CT) in the evaluation of retinoblastoma, we reviewed thirteen cases of retinoblastoma which presented at Hospital University Sains Malaysia, Kelantan, Malaysia, from August 1986 to June 1991. High resolution computed tomography of the orbits was performed in all patients prior to therapy. Nine patients (69%) had unilateral and four (31%) had bilateral retinoblastoma. The interesting features were the remarkably high incidence in the right eye (89%) as compared to the left eye (11%) in unilateral retinoblastoma, and overall predominance of the male population (male to female ratio was 2:1). Computed tomography detected intraocular calcification in 82% of the tumourous eyes. All patients presented at late stages when tumours were of large size. The presence of calcification was not related to the size of the tumour. CT detected calcification in a suspected retinoblastoma with a high degree of accuracy. Computed tomographic evidence of intraocular calcification in children under 3 years of age is highly suggestive of retinoblastoma.
Coronary heart disease is a major health problem in Malaysia with high morbidity and mortality. Common primary screening tool of cardiovascular risk stratification is exercise treadmill test (ETT). This communication is to determine the performance of coronary artery calcium score a new method to stratify the presence of obstructive coronary artery disease (CAD) in comparison to traditional ETT in patients having coronary artery diseases.