Displaying publications 1 - 20 of 355 in total

Abstract:
Sort:
  1. Shafik N, Ibrahim N, Gafor AHA
    Saudi J Kidney Dis Transpl, 2023 Nov 01;34(6):642-654.
    PMID: 38725213 DOI: 10.4103/sjkdt.sjkdt_81_22
    Hemodialysis (HD) and peritoneal dialysis (PD) treatments impact the economic burden and psychological distress faced by end-stage kidney disease (ESKD) patients and their caregivers. This review aimed to discuss the concept of an economic burden and the economic burden of different treatment options, and to highlight research gaps regarding the scarcity of previous studies relating economic burden to psychological well-being. We searched five electronic databases for papers published in 2010-2020. Papers focusing on measures of the economic burden from the government's perspective and diseases other than ESKD were excluded. Out of the 6635 publications identified, 10 publications were included. Three categories of economic burden were identified, namely, direct medical costs, direct non-medical costs, and indirect costs. Direct medical costs required the highest expenditure, whereas the lowest economic burden was for indirect costs. HD patients incurred a higher economic burden than PD patients. Most of the studies were carried out in Asia. The results of the research suggest that the economic burden may affect patients and caregivers, but it is unclear whether the economic burden affects the psychological well-being of the patients and caregivers. Very few studies have assessed the relationship between economic burden and psychological well-being, and further research is needed to gain further insight into the relationship between these two variables.
    Matched MeSH terms: Renal Dialysis/economics; Renal Dialysis/psychology; Peritoneal Dialysis/economics; Peritoneal Dialysis/psychology
  2. Chang E, Lim JA, Low CL, Kassim A
    J Nephrol, 2021 02;34(1):97-104.
    PMID: 33394342 DOI: 10.1007/s40620-020-00903-0
    BACKGROUND: Water crisis is becoming a threat to the well-being of the human population worldwide and use of water for healthcare contributes substantially to this resource depletion. Hemodialysis consumes large quantities of water. A huge volume of high purity dialysis water is required to safely perform dialysis treatment. In this process, up to 60-70% of source water is discarded. Many strategies have been suggested to promote green dialysis, and these include reuse of water, however, very few dialysis facilities have taken the preliminary steps to employ it.

    METHODS: We share our experience in a developing country on an innovative reject-water reuse program combining aquaculture, hydroponic and horticulture activities. This is by far the first report on a "green dialysis" project involving aquaponics that reuse dialysis reverse osmosis (RO) reject water.

    RESULTS: Our expereince suggests that reject water can be reused to promote water conservation with encouraging results. It provides a good and biosecure environment for fish breeding and vegetable farming . This project promotes a reduction in carbon footprint, a reduction in water waste, a sustainable organic food source, may lead to income generation, and provides a shared purpose and sense of pride among staff and dialysis patients.

    CONCLUSIONS: Encompassing "environmental protection" practices into a hemodialysis unit can be done with relatively simple and practical steps.

    Matched MeSH terms: Renal Dialysis*
  3. Sahathevan S, Khor BH, Yeong CH, Tan TH, Meera Mohaideen AK, Ng HM, et al.
    JPEN J Parenter Enteral Nutr, 2021 02;45(2):422-426.
    PMID: 32384179 DOI: 10.1002/jpen.1867
    BACKGROUND: Muscle wasting, prevalent in maintenance hemodialysis (HD) patients diagnosed with protein-energy wasting, represents an assessment challenge in the outpatient HD setting. Quadriceps muscle thickness (QMT) and cross-sectional area (CSA) assessment by ultrasound (US) is a potential surrogate measure for muscle wasting. We aimed to determine the validity of US to measure QMT and CSA against the gold standard-computed tomography (CT).

    METHODS: Twenty-six patients on HD underwent US and CT scans on the same day, postdialysis session. QMT for rectus femoris (RF) and vastus intermedius (VI) muscles was taken at the midpoint (MID) and two-thirds (2/3) of both thighs and CSA of the RF muscle (RFCSA ), respectively. Correlation between US and CT measurements was determined by intraclass correlation coefficient (ICC) and Bland-Altman plot.

    RESULTS: ICC (95% CI) computed between US and CT was 0.94 (0.87-0.97), 0.97 (0.93-0.99), 0.94 (0.87-0.97), 0.94 (0.86-0.97), and 0.92 (0.83-0.97) for RFMID , VIMID, RF2/3, VI2/3 , and RFCSA , respectively (all P < 0.001). Bland-Altman analysis indicated no bias in agreement between both methods.

    CONCLUSION: The US imaging offers a valid and quick bedside assessment approach to assess muscle wasting in HD patients.

    Matched MeSH terms: Renal Dialysis*
  4. Tan PC, Morad Z
    Perit Dial Int, 2003 Dec;23 Suppl 2:S206-9.
    PMID: 17986550
    Clinical disciplines in which the nurse plays as pre-eminent a role in total patient care as in peritoneal dialysis (PD) are few. The PD nurse is readily identified by the patient as the principal source of advice on day-to-day aspects of treatment, as a resource manager for supplies of PD disposables and fluids, and as a general counselor for all kinds of advice, including diet, rehabilitation, and medication, among others. The PD nurse is thus the key individual in the PD unit, and most activities involve and revolve around the nursing staff. It is therefore not surprising that most nephrologists pay considerable attention to the selection of PD nurses, particularly in long-term PD programs such as continuous ambulatory peritoneal dialysis (CAPD). The appointment of a PD nurse depends on finding an individual with the right attributes, broad general experience, and appropriate training.
    Matched MeSH terms: Peritoneal Dialysis/nursing*
  5. Mak WY, Leong CT, Ong LM, Bavanandan S, Mushahar L, Goh BL, et al.
    Perit Dial Int, 2021 05;41(3):273-283.
    PMID: 33733911 DOI: 10.1177/0896860821993954
    BACKGROUND: We compared the clinical effectiveness of a new peritoneal dialysis (PD) product with polyvinyl chloride-containing tubing (Stay Safe Link®, SSL) with the plastic-free alternative (Stay Safe®, STS) in patients on continuous ambulatory peritoneal dialysis (CAPD).

    METHOD: A multicentre, parallel, randomised, controlled, open-label, non-inferiority trial was conducted. Adult patients receiving CAPD were randomised in a 1:1 ratio to SSL or STS. The primary outcome was the rate of peritonitis after 1 year of follow-up.

    RESULTS: A total of 472 subjects were randomised (SSL, n = 233; STS, n = 239). One subject in each group was excluded from the analysis as they withdrew consent before the first dialysis dose. Four hundred and seventy subjects (SSL, n = 232; STS, n = 238) were included in the modified intention-to-treat analysis. Non-inferiority between two groups was established as no significant difference was found in peritonitis rate (incident rate ratio: 0.91, 95% CI: 0.65-1.28). No significant difference was detected in weekly Kt/V (p = 0.58) and creatinine clearance (p = 0.55). However, the average ultrafiltration volume was significantly lower in SSL, with a mean difference of 93 ml (p < 0.01). SSL also demonstrated a 2.57-times higher risk of device defect than STS (95% CI: 1.77-3.75).

    CONCLUSION: SSL was non-inferior in peritonitis rate compared to plastic-free STS over 1 year in patients requiring CAPD. There was no difference in the delivered dialysis dose, but there was a higher rate of device defects with SSL.

    Matched MeSH terms: Peritoneal Dialysis*
  6. Goh BL, Shanmuganathan M, Ang KL
    Perit Dial Int, 2021 11;41(6):587.
    PMID: 34423706 DOI: 10.1177/08968608211040361
    Matched MeSH terms: Peritoneal Dialysis, Continuous Ambulatory*
  7. Rozi NRB, Bin Wan Ali WASR, Bin Draman CR, Pasi HB, Rathor MY
    Saudi J Kidney Dis Transpl, 2022 Sep 01;33(5):664-673.
    PMID: 37955458 DOI: 10.4103/1319-2442.389426
    The role of end-of-life care is fundamental for end-stage renal disease (ESRD) patients, who are known to have a high morbidity and mortality rate despite being on dialysis. This requires effective communication and shared decision-making. Thus, exploring patients' knowledge and perceptions is essential to improve the gaps in delivering end-of-life care. This study aimed to describe the knowledge and perceptions of end-of-life care among ESRD patients on hemodialysis (HD). This was a cross-sectional study involving 14 outpatient HD centers in Kuantan, Malaysia. Patients were recruited from March to June 2019. A validated questionnaire was delivered via interview-based surveys by the researcher or trained interviewers. The majority of the respondents had poor knowledge of the disease and end-of-life care. However, more than 70% of the respondents felt that it was important for them to be actively involved in medical decision-making, as well as being prepared and planning for death. End-of-life needs, which included management of symptoms and psychological, social, and spiritual support, were important to most respondents. Additionally, patients with higher educational backgrounds were observed to have higher scores for both knowledge and perceptions (P <0.05). The study found poor knowledge but acceptable perceptions among patients. This highlights the gaps in the current local approach in clinical practice to end-of-life care in ESRD.
    Matched MeSH terms: Renal Dialysis/adverse effects; Renal Dialysis/psychology
  8. Sreenevasan G
    Br J Urol, 1970 Dec;42(6):741.
    PMID: 5497398
    Matched MeSH terms: Renal Dialysis/mortality*; Peritoneal Dialysis/mortality*
  9. Hooi LS
    Med J Malaysia, 2006 Dec;61(5):513-5.
    PMID: 17623948
    Matched MeSH terms: Renal Dialysis*
  10. Ling TW, Khuan L, Baharom A, Arshad MM
    Nephrol Nurs J, 2021 3 9;48(1):31-48.
    PMID: 33683842
    The purpose of this literature review was to explore the qualitative evidence on coping strategies used by patients with end stage kidney disease (ESKD) to manage the challenges and outcomes associated with the condition. A systematic review design following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines was used, and a thematic analysis was used to analyze the data. Four themes were identified from the 14 selected studies: external support, emotion management strategies, reliance on faith or spirituality, and self-care practices. Implications of these findings are discussed. Further primary qualitative studies using interviews and focus groups are needed to gain additional in-depth evidence of ESKD-related coping strategies.
    Matched MeSH terms: Renal Dialysis*
  11. Collister D, Mbuagbaw L, Guyatt G, Devereaux PJ, Tennankore KK, Reis G, et al.
    Contemp Clin Trials, 2021 08;107:106466.
    PMID: 34098039 DOI: 10.1016/j.cct.2021.106466
    BACKGROUND/AIMS: To examine how measuring adherence at 3 weeks by self-report and pill counts compares to measurements at 7 weeks in a pre-randomization run-in period.

    METHODS: Study within a trial of an international parallel group randomized controlled trial (RCT) that compares spironolactone to placebo. Adults receiving dialysis enter an 8-week active run-in period with spironolactone. Adherence was assessed by both self-report and pill counts in a subgroup of participants at both 3 weeks and 7 weeks.

    RESULTS: 332 participants entered the run-in period of which 166 had complete data. By self-report, 146/166 (94.0%) and 153/166 (92.2%) had at least 80% adherence at 3 and 7 weeks respectively (kappa = 0.27 (95% C.I. 0.16 to 0.38). By pill counts, the mean (SD) adherence was 96.5% (16.1%) and 92.4% (18.2%) at 3 and 7 weeks respectively (r = 0.32) with a mean (SD) difference of 3.1% (17.8%) and a 95% limit of agreement from -31.7% to +37.9%. The proportion of adherent participants by self-report and pill counts at 3 weeks agreed in 87.4% of participants (McNemar's p-value 0.58, kappa 0.11, p = 0.02) and at 7 weeks agreed in 92.2% (McNemar's p-value 0.82, kappa 0.47, p 

    Matched MeSH terms: Renal Dialysis*
  12. Bharati J, Jha V
    Semin Dial, 2020 11;33(6):490-498.
    PMID: 33030777 DOI: 10.1111/sdi.12924
    Dialysis adequacy is conventionally quantified as net urea clearance. Single pool (sp) Kt/Vurea remains the best studied measure of dialysis adequacy globally. Other measures such as fluid status control, anemia correction, and mineral metabolism are monitored variably. Increasing use of hemodiafiltration across Europe and many parts of Japan and Australia is predicated on studies showing better patient survival with middle molecule clearance. Apart from local clinical practice guidelines, the income level and public health policy of a country determine quality of dialysis services. Among developed nations, small solute clearance adequacy targets are achieved with high frequency. In the United States, dialysis adequacy target is met by focussing on high blood flow rates and large dialyzer size, sometimes at the cost of session time. In Japan, Australia, and Germany, session length is given importance. Dialysis adequacy reporting is restricted and inconsistent in developing nations. The Gulf Cooperation Council countries, Russia and Malaysia, respectively, are close to achieving dialysis adequacy target (spKt/Vurea ≥1.2) universally in their dialysis populations. Patient-reported outcomes are typically measured only in developed countries. Patient survival on dialysis, partly linked to dialysis adequacy, varies greatly around the world, with Japan having the best survival rates. Until the development of better markers of dialysis adequacy, universal consistency in reporting of conventional parameters with a focus on patient-reported measures should be endeavored.
    Matched MeSH terms: Renal Dialysis*
  13. Abu Maloh HIA, Soh KL, Chong SC, Ismail SIF, Soh KG, Abu Maloh DI, et al.
    Clin Nurs Res, 2023 Feb;32(2):288-297.
    PMID: 35915917 DOI: 10.1177/10547738221112759
    Benson's relaxation affects many symptoms among hemodialysis patients. A cluster-randomized active control clinical trial with three repeated measures; pre, 1-week, and 1-month post-intervention sought to evaluate the effectiveness of Benson's Relaxation on pain and perceived stress (P&PS) among hemodialysis patients. Two governmental hospitals were randomly assigned to intervention and control. Thirty-six participants were randomly selected; 18 were intervention, and 18 were controlled. The intervention group performed Benson's Relaxation twice a day for 10 minutes for 8 weeks after a training session. The control group received an educational session about Progressive Relaxation. Findings revealed a statistically significant reduction in the PSS-10 and PRI scores between pre-intervention and 1 month after-intervention (p  .05). Benson's Relaxation significantly relieved P&PS among hemodialysis patients but not after only 1 week of practicing.
    Matched MeSH terms: Renal Dialysis*
  14. Lim TO, Lim YN, Wong HS, Ahmad G, Singam TS, Morad Z, et al.
    Med J Malaysia, 1999 Dec;54(4):442-52.
    PMID: 11072461
    We determine the cost effectiveness of centre and home haemodialysis (HD), continuous ambulatory peritoneal dialysis (CAPD) and intermittent peritoneal dialysis (IPD) treatment in the Ministry of Health (MOH) programme. The viewpoint taken for this evaluation is that of MOH. Cost categories identified were capital cost, dialysis operational cost, medical cost and general hospital cost. Cost estimates were mostly based on actual resource utilisation. Life years saved were estimated based on Dialysis Registry data on 2480 HD and 732 CAPD patients. Overall, the cost-effectiveness ratio (CER) of centre HD was RM21620/life year saved. Those of home HD, CAPD and IPD were RM23375, RM30469 and RM36016 respectively. Sensitivity analyses did not change the ranking of the CER. We conclude the MOH dialysis programme was cost-effective, and among the various dialysis modalities centre HD was the most cost-effective.
    Matched MeSH terms: Renal Dialysis/economics*; Peritoneal Dialysis/economics*; Peritoneal Dialysis, Continuous Ambulatory/economics*
  15. Goh BL, Ganeshadeva YM, Chew SE, Dalimi MS
    Semin Dial, 2008 Nov-Dec;21(6):561-6.
    PMID: 18764787 DOI: 10.1111/j.1525-139X.2008.00478.x
    Traditionally peritoneal dialysis (PD) catheter was implanted by surgeons using mini-laparotomy or open technique in Malaysia. We introduced peritoneoscopic Tenckhoff catheter insertion technique since the beginning of our PD program. Data were collected from the start of our PD program in February 2006 until April 2008. All Tenckhoff catheters were inserted by nephrologists using the peritoneoscope technique. We also compare the penetration rate of PD versus hemodialysis (HD) in our center, as well as comparing to national PD penetration rate. There were 83 patients who underwent 91 peritoneoscope Tenckhoff catheter insertion procedures from March 2006 until April 2008. The patients were mostly female (66%) with the mean age of 51.99 +/- 1.78 years and the majority (67%) of them were diabetics. All together there were 749.7 patient-months at risk and the overall peritonitis rate was 1 in 93.7 patient-months. The 1-year catheter survival was 86.5%. Primary catheter failure (defined as failure of the catheter within 1 month of insertion) occurred in 16 procedures (17.6%). The main cause of catheter malfunction was catheter tip migration and omentum wrap. The penetration ratio of PD when compared with HD in our center is 44.8%, which is about 4.5 times the national average. With our integrated care approach where nephrologist was heavily involved from the outset of renal replacement therapy discussion, PD access implantation to the assistance of spoke person to whom new patient can identify with, we were able to achieve PD penetration rate which far exceeds that of the national average.
    Matched MeSH terms: Peritoneal Dialysis/instrumentation*; Peritoneal Dialysis/standards*
  16. Borzych-Duzalka D, Shroff R, Ariceta G, Yap YC, Paglialonga F, Xu H, et al.
    Am J Kidney Dis, 2019 08;74(2):193-202.
    PMID: 31010601 DOI: 10.1053/j.ajkd.2019.02.014
    RATIONALE & OBJECTIVE: Arteriovenous fistulas (AVFs) have been recommended as the preferred vascular access for pediatric patients on maintenance hemodialysis (HD), but data comparing AVFs with other access types are scant. We studied vascular access choice, placement, complications, and outcomes in children.

    STUDY DESIGN: Prospective observational cohort study.

    SETTING & PARTICIPANTS: 552 children and adolescents from 27 countries on maintenance HD followed up prospectively by the International Pediatric HD Network (IPHN) Registry between 2012 and 2017.

    PREDICTOR: Type of vascular access: AVF, central venous catheter (CVC), or arteriovenous graft.

    OUTCOME: Infectious and noninfectious vascular access complication rates, dialysis performance, biochemical and hematologic parameters, and clinical outcomes.

    ANALYTICAL APPROACH: Univariate and multivariable linear mixed models, generalized linear mixed models, and proportional hazards models; cumulative incidence functions.

    RESULTS: During 314 cumulative patient-years, 628 CVCs, 225 AVFs, and 17 arteriovenous grafts were placed. One-third of the children with an AVF required a temporary CVC until fistula maturation. Vascular access choice was associated with age and expectations for early transplantation. There was a 3-fold higher living related transplantation rate and lower median time to transplantation of 14 (IQR, 6-23) versus 20 (IQR, 14-36) months with CVCs compared with AVFs. Higher blood flow rates and Kt/Vurea were achieved with AVFs than with CVCs. Infectious complications were reported only with CVCs (1.3/1,000 catheter-days) and required vascular access replacement in 47%. CVC dysfunction rates were 2.5/1,000 catheter-days compared to 1.2/1,000 fistula-days. CVCs required 82% more revisions and almost 3-fold more vascular access replacements to a different site than AVFs (P<0.001).

    LIMITATIONS: Clinical rather than population-based data.

    CONCLUSIONS: CVCs are the predominant vascular access choice in children receiving HD within the IPHN. Age-related anatomical limitations and expected early living related transplantation were associated with CVC use. CVCs were associated with poorer dialysis efficacy, higher complication rates, and more frequent need for vascular access replacement. Such findings call for a re-evaluation of pediatric CVC use and practices.

    Matched MeSH terms: Renal Dialysis/adverse effects; Renal Dialysis/methods*
  17. Goh BL
    Contrib Nephrol, 2017;189:79-84.
    PMID: 27951553
    BACKGROUND: The success rate of peritoneal dialysis (PD) catheter insertion is known to vary among different operators and may be influenced by many factors such as patient and various situational factors. Traditionally, surgeons have inserted Tenckhoff catheters by mini-laparotomy or an open technique. However, with recent advances in endoscopic instrumentation and video capabilities, peritoneoscope Tenckhoff catheter insertion has become a viable approach in interventional nephrologist-initiated PD access programmes.

    SUMMARY: Nephrologist-initiated peritoneoscopic PD access programs have had a positive impact on PD penetration. The technique has been associated with a better primary success rate, superior catheter survival, less postoperative pain, shorter hospital stay, and shorter catheter break-in time compared with the conventional surgical technique. The role of interventional nephrologists in peritoneoscope Tenckhoff catheter placement is still perceived to be a relatively new advance, investigational by some, and many nephrologists and surgeons alike remain sceptical of the value of this recent option. Crucial questions often raised are how many procedures one needs to perform before being considered competent and who should be credentialed to perform the procedure or supervise trainees performing it. The evaluation of technical proficiency in a specific operation is difficult and complex. Cumulative summation (CUSUM) analysis is one option for tracking the success and failure of technical skill and examining trends over time. Key Messages: The author's facility has had good outcomes with a nephrologist-initiated peritoneoscopic PD access programme. Quality control of PD catheter insertion can be performed using CUSUM charting to monitor for primary catheter dysfunction, primary leak, and primary peritonitis.

    Matched MeSH terms: Peritoneal Dialysis/methods*; Peritoneal Dialysis/trends
  18. Kandel S, Zaidi STR, Wanandy ST, Ming LC, Castelino RL, Sud K, et al.
    Perit Dial Int, 2017 11 21;38(1):49-56.
    PMID: 29162678 DOI: 10.3747/pdi.2017.00115
    BACKGROUND: Intraperitoneal (IP) administration of ceftazidime is recommended for the treatment of peritoneal dialysis-associated peritonitis (PDAP) from Pseudomonas. Patients with PDAP may also need IP heparin to overcome problems with drainage of turbid peritoneal dialysis (PD) fluids and blockage of catheters with fibrin. Physico-chemical stability of ceftazidime and heparin, and biological stability of heparin in many types of PD solutions is unknown. Therefore, we investigated the stability of ceftazidime and heparin in 4 types of PD solutions.

    METHODS: A total of 12 PD bags (3 for each type of solution) containing ceftazidime and heparin were prepared and stored at 4°C for 120 hours, and then at 25°C for 6 hours, and finally at 37°C for 12 hours. An aliquot was withdrawn after predefined time points and analyzed for the concentration of ceftazidime and heparin using high-performance liquid-chromatography (HPLC). Samples were assessed for pH, color changes, particle content, and anticoagulant activity of heparin.

    RESULTS: Ceftazidime and heparin retained more than 91% of their initial concentration when stored at 4°C for 120 hours followed by storage at 25°C for 6 hours and then at 37°C for 12 hours. Heparin retained more than 95% of its initial activity throughout the study period. Particle formation was not detected at any time under the storage conditions. The pH and color remained essentially unchanged throughout the study.

    CONCLUSIONS: Ceftazidime-heparin admixture retains its stability over long periods of storage at different temperatures, allowing its potential use for PDAP treatment in outpatient and remote settings.

    Matched MeSH terms: Peritoneal Dialysis; Dialysis Solutions/chemistry*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links