METHODS: We conducted a comprehensive literature review, searching databases such as PubMed, Embase, and Web of Science until June 2023. Our objective was to identify studies that compared the efficacy of 68Ga-PSMA-11 PET/CT and mpMRI in detecting primary prostate cancer. To determine heterogeneity, the I2 statistic was used. Meta-regression analysis and leave-one-out sensitivity analysis were conducted to identify potential sources of heterogeneity.
RESULTS: Initially, 1286 publications were found, but after careful evaluation, only 16 studies involving 1227 patients were analyzed thoroughly. The results showed that the 68Ga-PSMA-11 PET/CT method had a pooled sensitivity and specificity of 0.87 (95 % CI: 0.80-0.92) and 0.80 (95 % CI: 0.69-0.89), respectively, for diagnosing prostatic cancer. Similarly, the values for mpMRI were determined as 0.84 (95 % CI: 0.75-0.92) and 0.74 (95 % CI: 0.61-0.86), respectively. There were no significant differences in diagnostic effectiveness observed when comparing two primary prostate cancer methodologies (pooled sensitivity P = 0.62, pooled specificity P = 0.50). Despite this, the funnel plots showed symmetry and the Egger test results (P values > 0.05) suggested there was no publication bias.
CONCLUSIONS: After an extensive meta-analysis, it was found that both 68Ga-PSMA-11 PET/CT and mpMRI demonstrate similar diagnostic effectiveness in detecting primary prostate cancer. Future larger prospective studies are warranted to investigate this issue further.
METHODS: The European Association of Nuclear Medicine (EANM) procedure guidelines version 2.0 for FDG-PET tumor imaging has adhered for this purpose. A NEMA2012/IEC2008 phantom was filled with tumor to background ratio of 10:1 with the activity concentration of 30 kBq/ml ± 10 and 3 kBq/ml ± 10% for each radioisotope. The phantom was scanned using different acquisition times per bed position (1, 5, 7, 10 and 15 min) to determine the Tmin. The definition of Tmin was performed using an image coefficient of variations (COV) of 15%.
RESULTS: Tmin obtained for 18F, 68Ga and 124I were 3.08, 3.24 and 32.93 min, respectively. Quantitative analyses among 18F, 68Ga and 124I images were performed. Signal-to-noise ratio (SNR), contrast recovery coefficients (CRC), and visibility (VH) are the image quality parameters analysed in this study. Generally, 68Ga and 18F gave better image quality as compared to 124I for all the parameters studied.
CONCLUSION: We have defined Tmin for 18F, 68Ga and 124I SPECT CT imaging based on NEMA2012/IEC2008 phantom imaging. Despite the long scanning time suggested by Tmin, improvement in the image quality is acquired especially for 124I. In clinical practice, the long acquisition time, nevertheless, may cause patient discomfort and motion artifact.