Displaying all 18 publications

Abstract:
Sort:
  1. Mazlan R, Ting TL, Mukari SZ, Abdullah A
    Int J Pediatr Otorhinolaryngol, 2014 Feb;78(2):348-53.
    PMID: 24380662 DOI: 10.1016/j.ijporl.2013.12.014
    The present study aimed to determine levels of parents' satisfaction associated with the universal newborn hearing screening process in a university hospital setting in Kuala Lumpur, Malaysia.
    Matched MeSH terms: Neonatal Screening/methods*
  2. Abdul Wahid SN, Md Daud MK, Sidek D, Abd Rahman N, Mansor S, Zakaria MN
    Int J Pediatr Otorhinolaryngol, 2012 Sep;76(9):1366-9.
    PMID: 22770594 DOI: 10.1016/j.ijporl.2012.06.008
    OBJECTIVE: To identify the outcomes of hearing screening using different protocols of both Distortion Product Otoacoustic Emissions (DPOAE) and Automated Auditory Brainstem Response (AABR) tests in the same ear of the babies in a neonatal unit population.
    METHODS: A cross-sectional study was carried out on babies who were admitted into a neonatal unit. By using a formula of single proportion and considering 20% drop out, the number of sample required was 114. The subjects were chosen by using a systematic random sampling. The infants selected were subjected to DPOAE followed by AABR tests screening at the same setting before discharge.
    RESULTS: There were 73 newborns (61.6% male and 38.4% female) participated in this study with a total of 146 ears screened. Ototoxic medication was the most common risk factor followed by hyperbilirubinaemia and low birth weight. AABR had higher passing rate (82.9%) as compared to DPOAE (77.4%). The highest passing rate was achieved if the protocol of either passed DPOAE or AABR was used (90.4%). The rate was lower when auditory neuropathy spectrum disorder (ANSD) has been considered (82.9%). Hyperbilirubinaemia, prematurity, craniofacial malformation and ototoxic drugs seem to be the high risk factors for auditory neuropathy.
    CONCLUSION: AABR has a higher passing rate as compared to DPOAE. However, the use of both instruments in the screening process especially in NICU will be useful to determine the infants with ANSD who may need different approach to management. Therefore, a protocol in which newborns are tested with AABR first and then followed by DPOAE on those who fail the AABR is recommended.
    Matched MeSH terms: Neonatal Screening/methods*
  3. George E, Lai MI, Teh LK, Ramasamy R, Goh EH, Asokan K, et al.
    Med J Malaysia, 2011 Dec;66(5):429-34.
    PMID: 22390095 MyJurnal
    Detection and quantification of Hb subtypes of human blood is integral to presumptive identification of thalassaemias. It has been used in neonatal screening of thalassaemia and Hb variants. The use of discarded red blood cells following processing of the cord blood for stem cells provides readily available diagnostic material for thalassaemia screening. In this study, we determined the range of Hb subtypes in 195 consecutive cord blood samples collected for cord blood banking. The 'cord blood samples' analysed were those of the remaining red blood cells after the cord blood was processed for stem cell storage. Quantification of Hb subtypes by high performance liquid chromatography (HPLC) was done on BioRad Variant II Hb testing system. Only 73 (36.5%) of the samples could be analyzed neat without dilution. With a 1:300 dilution with wash solution the acceptable area as recommended by the manufacturer for reading of a C-gram within the 1 to 3 million ranges were achieved in all. Eighteen (9%) 12 showed classical Hb Barts (y4) prerun peaks were confirmed by Sebia Hydrasys automated Hb gel electrophoresis and quantified by Sebia Capillarys 2 capillary electrophoresis. Only 1 (0.5%) was presumptively identified with HbH disease. Due to the limited number of samples no beta-thalassaemia major, Hb E beta-thalassaemia and Hb Barts hydrops fetalis were found. The HPLC assay was possible at a cost US$ 5 per sample and a turnover time of 10 samples per hour without technical difficulties. This study reports an effective and valuable protocol for thalassaemia screening in red blood cells which would otherwise be discarded during cord blood processing. Cord blood with severe and intermediate forms of thalassaemia can be preselected and not stored.
    Matched MeSH terms: Neonatal Screening/methods*
  4. Padilla CD, Therrell BL
    J Inherit Metab Dis, 2007 Aug;30(4):490-506.
    PMID: 17643195
    The success of blood spot newborn screening in the USA led to early screening efforts in parts of the Asia Pacific Region in the mid-1960s. While there were early screening leaders in the region, many of the countries with depressed and developing economies are only now beginning organized screening efforts. Four periods of screening growth in the Asia Pacific region were identified. Beginning in the 1960s, blood spot screening began in New Zealand and Australia, followed by Japan and a cord blood screening programme for G6PD deficiency in Singapore. In the 1980s, established programmes added congenital hypothyroidism and new programmes developed in Taiwan, Hong Kong, China (Shanghai), India and Malaysia. Programmes developing in the 1990s built on the experience of others developing more rapidly in Korea, Thailand and the Philippines. In the 2000s, with limited funding support from the International Atomic Energy Agency, there has been screening programme development around detection of congenital hypothyroidism in Indonesia, Mongolia, Sri Lanka, Myanmar and Pakistan. Palau has recently contracted with the Philippine newborn screening programme. There is little information available on newborn screening activities in Nepal, Cambodia, Laos and the other Pacific Island nations, with no organized screening efforts apparent. Since approximately half of the births in the world occur in the Asia Pacific Region, it is important to continue the ongoing implementation and expansion efforts so that these children can attain the same health status as children in more developed parts of the world and their full potential can be realized.
    Matched MeSH terms: Neonatal Screening/methods*
  5. Khairi MD, Din S, Shahid H, Normastura AR
    J Laryngol Otol, 2005 Sep;119(9):678-83.
    PMID: 16156907
    The objective of this prospective study was to report on the prevalence of hearing impairment in the neonatal unit population. From 15 February 2000 to 15 March 2000 and from 15 February 2001 to 15 May 2001, 401 neonates were screened using transient evoked otoacoustic emissions (TEOAE) followed by second-stage screening of those infants who failed the initial test. Eight (2 per cent) infants failed one ear and 23 (5.74 per cent) infants failed both ears, adding up to 7.74 per cent planned for second-stage screening. Five out of 22 infants who came for the follow up failed the screening, resulting in a prevalence of hearing impairment of 1 per cent (95 per cent confidence interval [95% CI]: 0.0-2.0). Craniofacial malformations, very low birth weight, ototoxic medication, stigmata/syndromes associated with hearing loss and hyperbilirubinaemia at the level of exchange tranfusion were identified to be independent significant risk factors for hearing impairment, while poor Apgar scores and mechanical ventilation of more than five days were not. In conclusion, hearing screening in high-risk neonates revealed a total of 1 per cent with hearing loss. The changes in the risk profile indicate improved perinatal handling in a neonatal population at risk for hearing disorders.
    Matched MeSH terms: Neonatal Screening/methods*
  6. Wu LL, Sazali BS, Adeeb N, Khalid BA
    Singapore Med J, 1999 Jan;40(1):23-6.
    PMID: 10361481
    Clinical diagnosis of congenital hypothyroidism (CH) is difficult at birth without neonatal screening. In line with the priorities of the national health services in Malaysia towards preventive medicine, early diagnosis and treatment of CH is emphasised. We conducted a pilot study at Kuala Lumpur's Maternity Hospital between April 1995 and November 1995 to estimate the incidence of CH and also evaluated the problems associated with large-scale neonatal screening using a commercial TSH kit on cord bloodspots.
    Matched MeSH terms: Neonatal Screening/methods*
  7. Wang FL, Boo NY, Ainoon O, Wong MK
    Singapore Med J, 2009 Jan;50(1):62-7.
    PMID: 19224086
    INTRODUCTION:
    This study aimed to compare the detection rates of glucose-6-phosphate dehydrogenase (G6PD) deficiency in neonates by fluorescent spot test (FST), enzyme assay and molecular methods, and to identify which method was a significant predictor of severe hyperbilirubinaemia.
    METHODS:
    74 term infants of Chinese descent admitted with severe hyperbilirubinaemia (total serum bilirubin equal or greater than 300 micromol/L) and 125 healthy term infants born in the hospital without severe hyperbilirubinaemia were recruited into the study. Specimens of blood were collected from each infant for FST, G6PD enzyme assay and TaqMan minor groove binder single nucleotide polymorphism genotyping assay.
    RESULTS:
    26 (13.1 percent) infants were diagnosed to have G6PD deficiency by FST. They had significantly lower median enzyme levels (0.8 IU/g Hb, interquartile range [IQR] 0.4-4.3) than those diagnosed to be normal (12.0 IU/g Hb, IQR 10.3-15.8) (p-value is less than 0.0001). Based on the enzyme assay, 39 (19.6 percent) infants had G6PD deficiency at an enzyme cut-off level of less than 8.5 IU/g Hb. G6PD mutation was detected in 27 (13.6 percent) infants. Logistic regression analysis showed that the only significant predictors of severe hyperbilirubinaemia were G6PD deficiency based on a cut-off level of less than 8.5 IU/g Hb (adjusted odds ratio [OR] 5.3, 95 percent confidence interval [CI] 2.4-11.4; p-value is less than 0.0001) and exclusive breast-feeding (adjusted OR 11.4, 95 percent CI 3.1-42.4; p-value is less than 0.0001). The gender and birth weight of infants, FST results, G6PD mutation and the actual G6PD enzyme levels were not significant predictors.
    CONCLUSION:
    A G6PD enzyme level of less than 8.5 IU/g Hb is a significant predictor of severe hyperbilirubinaemia
    Matched MeSH terms: Neonatal Screening/methods*
  8. Azma RZ, Hidayati N, Farisah NR, Hamidah NH, Ainoon O
    PMID: 21073074
    Glucose-6-phosphate dehydrogenase (G6PD) deficiency is one of the commonest causes of neonatal jaundice in Malaysia. Screening of cord blood for G6PD deficiency by the semiquantitative fluorescent spot test (FST) is performed in Malaysia but this test can miss cases of partial G6PD deficiency. The OSMMR-D kit assay measures G6PD activity and hemoglobin (Hb) concentration, allowing direct expression of results in U/gHb. We evaluated this method and established the normal range for G6PD activity in normal term neonates and adults. EDTA blood from 94 neonates and 295 adults (age 15-59 years old) with normal Hb and FST were selected. The normal means for G6PD activity for neonates and adults were 12.43 +/- 2.28 U/gHb and 9.21 +/- 2.6 U/gHb, respectively; the reference ranges for normal G6PD activity in neonates and adults were 10.15-14.71 U/gHb and 6.61-11.81 U/gHb respectively. There were no significant differences in mean normal G6PD activity between the Malays and Chinese racial groups or between genders. The upper and lower limit cut-off points for partial deficiency in neonates were 7.4 U/gHb (60% of the normal mean) and 2.5 U/gHb (20% of the normal mean), respectively. For adults, the upper and lower limit cut-off points for partial deficiency in adults were 5.52 U/gHb (60% of the normal mean) and 1.84 U/gHb (20% of the normal mean), respectively. The quantitation of G6PD enzymes using this OSMMR-D kit with Hb normalization was simple since the Hb was analyzed simultaneously and the results were reproducible with a CV of less than 5%.
    Matched MeSH terms: Neonatal Screening/methods*
  9. Chua BS, Song LH, Chang CT, Lim XJ, Nachiappan J
    J Paediatr Child Health, 2021 01;57(1):12-14.
    PMID: 33078471 DOI: 10.1111/jpc.15226
    The coronavirus disease 2019 (COVID-19) cases was on an increasing trend, including in Malaysia. The Malaysian Ministry of Health had implemented a range of measures, such as the use of masks and social distancing, to reduce the risk of transmission. Traditionally, newborns are evaluated for neonatal jaundice using visual assessment, a capillary heel prick and serum bilirubin (SB) sampling in primary health-care clinics. This approach requires the physical presence of both parents and their newborns in the primary health-care clinics, causing crowding and increasing the risk of COVID-19 infections. To alleviate crowding, we implemented the transcutaneous bilirubin drive-through (DT) service, which is an established, non-invasive, painless and rapid method to determine the bilirubin levels. Throughout the screening, both parents and baby will be confined to their car. A total of 1842 babies were screened in our DT setting from April to July 2020. Of the total babies, 298 (16.1%) required venesection for SB measurement and 85 required admission for phototherapy. None with severe jaundice were missed since the implementation of this service. The average test duration per neonate was less than 5 min, while conventional venous bilirubin laboratory testing required an average of 1.5 h per neonate. The cost of the SB laboratory test and consumables was approximately USD 5 per test, with an estimated cost savings of USD 7720. DT screening may be introduced in health-care settings to reduce crowding and eliminate the need of painful blood sampling in newborns.
    Matched MeSH terms: Neonatal Screening/methods*
  10. Ngui LX, Tang IP, Prepageran N, Lai ZW
    Int J Pediatr Otorhinolaryngol, 2019 May;120:184-188.
    PMID: 30844634 DOI: 10.1016/j.ijporl.2019.02.045
    INTRODUCTION: Congenital hearing loss is one of the commonest congenital anomalies. Neonatal hearing screening aims to detect congenital hearing loss early and provide prompt intervention for better speech and language development. The two recommended methods for neonatal hearing screening are otoacoustic emission (OAE) and automated auditory brainstem response (AABR).

    OBJECTIVE: To study the effectiveness of distortion product otoacoustic emission (DPOAE) and automated auditory brainstem response (AABR) as first screening tool among non-risk newborns in a hospital with high delivery rate.

    METHOD: A total of 722 non-risk newborns (1444 ears) were screened with both DPOAE and AABR prior to discharge within one month. Babies who failed AABR were rescreened with AABR ± diagnostic auditory brainstem response tests within one month of age.

    RESULTS: The pass rate for AABR (67.9%) was higher than DPOAE (50.1%). Both DPOAE and AABR pass rates improved significantly with increasing age (p-value<0.001). The highest pass rate for both DPOAE and AABR were between the age of 36-48 h, 73.1% and 84.2% respectively. The mean testing time for AABR (13.54 min ± 7.47) was significantly longer than DPOAE (3.52 min ± 1.87), with a p-value of <0.001.

    CONCLUSIONS: OAE test is faster and easier than AABR, but with higher false positive rate. The most ideal hearing screening protocol should be tailored according to different centre.

    Matched MeSH terms: Neonatal Screening/methods*
  11. Boo NY, Chang YF, Leong YX, Tok ZY, Hooi LC, Chee SC, et al.
    Pediatr Res, 2019 08;86(2):216-220.
    PMID: 30696987 DOI: 10.1038/s41390-019-0304-0
    BACKGROUND: This study aimed to determine the accuracy of a point-of-care Bilistick method for measuring total serum bilirubin (TSB) and its turn-around-time (TAT) against hospital laboratory methods.

    METHODS: This prospective study was carried out on 561 term-gestation jaundiced neonates in two Malaysian hospitals. Venous blood sample was collected from each neonate for contemporary measurement of TSB by hospital laboratories and Bilistick. TAT was the time interval between specimen collection and TSB result reported by each method.

    RESULTS: The mean laboratory-measured TSB was 194.85 (±2.844) µmol/L and Bilistick TSB was 169.37 (±2.706) µmol/L. Pearson's correlation coefficient was: r = 0.901 (p 

    Matched MeSH terms: Neonatal Screening/methods
  12. Ainoon O, Alawiyah A, Yu YH, Cheong SK, Hamidah NH, Boo NY, et al.
    PMID: 12971572
    Neonatal screening for G6PD deficiency has long been established in many countries. The aim of the study was to determine whether the routine semiquantitative fluorescent spot test could detect all cases of G6PD deficiency, including those cases with partial deficiency (residual red cell G6PD activity between 20-60% of normal). We compared the results of G6PD screening by the semiquantitative fluorescent spot test and quantitative G6PD activity assay on a group of 976 neonates and 67 known female heterozygotes. The values for mean G6PD activity of G6PD-normal neonates and 293 healthy adult females were determined. There was no significant difference in the mean normal G6PD activity between the two racial groups in the neonates (669 Malays, 307 Chinese) and in the 293 healthy adult females (150 Malays, 143 Chinese) group. The values for the upper limits of total deficiency (20% of normal residual activity) for neonates and adult females were 2.92 U/gHb and 1.54 U/gHb, respectively. The upper limits of partial deficiency (60% of normal residual activity) were 8.7 U/gHb and 4.6 U/gHb respectively. The prevalence of G6PD deficiency among the male neonates was 5.1% (26) by both the fluorescent spot test and the enzyme assay method. The G6PD activity levels of all 26 cases of G6PD-deficient male neonates were < 20% normal (severe enzyme deficiency). In the female neonate group, the frequency of G6PD deficiency was 1.3% (6 of 472) by the fluorescent spot test and 9.35% (44 of 472) by enzyme assay. The 6 cases diagnosed as deficient by the fluorescent spot test showed severe enzyme deficiency (< 2.92 U/gHb). The remaining 38 female neonates had partial enzyme deficiency and all were misdiagnosed as normal by the fluorescent spot test. In the female heterozygote group, G6PD deficiency was diagnosed in 53% (35 of 67) by enzyme assay and in 7.5% (4 of 67) of cases by the fluorescent spot test. The 4 cases detected by fluorescent spot test had severe enzyme deficiency (<1.6 U/gHb). The remaining 31 (46.3%) cases, diagnosed as normal by fluorescent spot test, showed partial G6PD deficiency. In conclusion, we found that the semiquantitative fluorescent spot test could only diagnose cases of total G6PD deficiency and misclassified the partially-deficient cases as normal. In this study, the overall prevalence of G6PD deficiency was 3.28% by the semiquantitative fluorescent spot test and 7.17% by enzyme assay. This means that 3.9% of G6PD-deficient neonates were missed by the routine fluorescent spot test and they were found to be exclusively females. This study demonstrates a need to use a method that can correctly classify female heterozygotes with partial G6PD deficiency. The clinical implication is that these individuals may be at risk of the hemolytic complication of G6PD deficiency.
    Matched MeSH terms: Neonatal Screening/methods
  13. Mohd Khairi MD, Rafidah KN, Affizal A, Normastura AR, Suzana M, Normani ZM
    Int J Pediatr Otorhinolaryngol, 2011 Apr;75(4):513-7.
    PMID: 21292333 DOI: 10.1016/j.ijporl.2011.01.009
    To investigate the anxiety among mothers whom their babies have failed test results in the first stage of Universal Neonatal Hearing Screening Program.
    Matched MeSH terms: Neonatal Screening/methods*
  14. Amar HS, Ho JJ, Mohan AJ
    J Paediatr Child Health, 1999 Feb;35(1):63-6.
    PMID: 10234638
    OBJECTIVE: To determine the community prevalence of human immunodeficiency virus (HIV) in women at the time of delivery in a Malaysian setting.

    METHODOLOGY: Cord blood samples from a pilot screening programme for congenital hypothyroidism in 1995 at Ipoh city and surrounding district hospitals were screened anonymously for HIV 1 and 2. HIV status was determined using chemiluminescent technology. Positive samples were retested using the Genelavia Mixt assay.

    RESULTS: A total of 4927 samples were tested. The ethnic breakdown included 51.7% Malays, 18.9% Chinese, 14.3% Indian, 2.3% Others and 12.9% unknown. The geographical distribution of samples was 73.9% urban, 24.2% rural and 1.9% unknown. The seroprevalence of HIV positivity was 3.25 per 1000 deliveries (95% CI: 1.92-5.16). Seroprevalence was higher for samples from rural and Malay mothers.

    CONCLUSION: The high seroprevalence in this study suggests that the spread of HIV is far wider than that anticipated by mandatory national reporting. It also supports antenatal screening and the use of antiretroviral therapy as an important strategy to reduce perinatal transmission.

    Matched MeSH terms: Neonatal Screening/methods*
  15. Elmonem MA, Belanger-Quintana A, Bordugo A, Boruah R, Cortès-Saladelafont E, Endrakanti M, et al.
    Mol Genet Metab, 2020 11;131(3):285-288.
    PMID: 33004274 DOI: 10.1016/j.ymgme.2020.09.004
    Quantitative estimates for the global impact of COVID-19 on the diagnosis and management of patients with inborn errors of metabolism (IEM) are lacking. We collected relevant data from 16 specialized medical centers treating IEM patients in Europe, Asia and Africa. The median decline of reported IEM related services in March 1st-May 31st 2020 compared to the same period in 2019 were as high as 60-80% with a profound impact on patient management and care for this vulnerable patient group. More representative data along with outcome data and guidelines for managing IEM disorders under such extraordinary circumstances are needed.
    Matched MeSH terms: Neonatal Screening/methods
  16. Abdul Majid AH, Zakaria MN, Abdullah NAC, Hamzah S, Mukari SZS
    Int J Pediatr Otorhinolaryngol, 2017 Oct;101:107-111.
    PMID: 28964278 DOI: 10.1016/j.ijporl.2017.07.036
    OBJECTIVE: This paper aims to investigate the effects of perceived attitude and anxiety on awareness of UNHS among caregivers in Malaysia.

    METHODS: Using cross sectional research approach, data were collected and some 46 out of 87 questionnaires distributed to caregivers attending UNHS programs at selected public hospitals were usable for analysis (response rate of 52.8%). Partial Least Squares Method (PLS) algorithm and bootstrapping technique were employed to test the hypotheses of the study.

    RESULTS: R square value is 0.205, and it implies that exogenous latent variables explained 21% of the variance of the endogenous latent variable. This value indicates moderate and acceptable level of R-squared values. Findings from PLS structural model evaluation revealed that anxiety has no significant influence (β = -0.091, t = 0.753, p > 0.10) on caregivers' awareness; but perceived attitude has significant effect (β = -0.444, t = 3.434, p 

    Matched MeSH terms: Neonatal Screening/methods*