Displaying publications 1 - 20 of 29 in total

Abstract:
Sort:
  1. Solehuddin Shuib, Sahari, B.B., Wong, Shaw Voon, Arumugam, Manohar, Halim Kadarman, A.
    MyJurnal
    Bone is a living tissue. It continuously reproduces its structure and its growth depends partly upon the applied mechanical load. After an implant is inserted, the load equilibrium is disturbed, leading to bone resorption and the stress shielding phenomena. Aseptic loosening is the main contributor for hip prosthesis failure. The purpose of the study is to determine the effect of bone resorption on the stress values and hence obtain a better understanding of the behavior of the stress adaptive bone-remodeling. The bone material used for the analysis was assumed to be isotropic and linearly elastic, and the external loads applied comprised of a femoral head load and an abductor load. A Finite element computer program for evaluating the changes in bone's density and modulus was developed. The values of stress for bone, cement mantle in medial, and lateral positions of Total Hip Replacement (THR) are presented. The failure mechanisms of THR with bone resorption observed the implant loosening since stress is reduced.
    Matched MeSH terms: Prosthesis Failure
  2. Keun Seon J, Anwar Ayob K, Giun Noh M, Yeol Yang H
    Acta Orthop Traumatol Turc, 2024 Jan;58(1):68-72.
    PMID: 38525513 DOI: 10.5152/j.aott.2024.23115
    Oxidized zirconium (OxiniumTM) prostheses, made up of a metallic alloy of zirconium with a ceramic surface formed by oxidizing the outer layer, were developed as an alternative bearing surface to reduce polyethylene wear and decrease failure of total knee arthroplasty (TKA). We report a unique catastrophic failure of an Oxinium TKA with consequent accelerated wear and severe metallosis. Intraoperatively, we observed extensive wear grooving of the femoral component with exposure of the underlying silver layers and the complete wear of polyethylene on the medial side. Metallic debris had a peculiar arthrogram appearance, noted within the cut surface of the femur and tibia, indicative of the osteolysis that occurred, leading up to the failure of the implants. The histopathologic examination revealed a collection of macrophages with foreign-body reactions and black-pigmented metal-induced wear particles. Oxinium has clear benefits regarding superior wear properties; however, surgeons need to be aware that there is a risk of exposure to the underlying layers that may precede accelerated wear, deformation, and metallosis. Uncovering the deeper layers could result in the appearance of an arthrogram on plain radiographs. Early identification of polyethylene wear and prompt revision is crucial to avoid the rapid progression of subsequent metallosis and catastrophic implant failure, specifically when using oxidized zirconium components for TKA. To the best of our knowledge, this is the first report presenting a detailed histologic analysis to provide insight into the mechanisms of the failed Oxinium components.
    Matched MeSH terms: Prosthesis Failure
  3. Marwan M, Ibrahim M
    Injury, 1999 Jun;30(5):333-5.
    PMID: 10505126
    A simple technique for removal of the distal fragment of the broken intramedullary interlocking nail is described. It was successfully used in three patients with a broken nail due to nonunion. The technique requires only cerclage wire, which is available in any operating room, avoiding the difficulties obtaining the custom made hook and of excessive exposure to radiation.
    Matched MeSH terms: Prosthesis Failure*
  4. Lee YS, Lee SH, Lee ES, Fong TS
    BMC Musculoskelet Disord, 2019 Mar 20;20(1):118.
    PMID: 30894158 DOI: 10.1186/s12891-019-2505-4
    BACKGROUND: We report a case of hardware failure after distal femoral osteotomy (DFO) with a broken screw pulled out from the locking hole and positioned within the knee joint.

    CASE PRESENTATION: A 57-year-old man presented to our orthopedic outpatient department with 3-months history of an unusual painful swelling at the operated area following DFO. The leakage of joint fluid from the penetrated suprapatellar pouch was assumed to be the reason for this complication.

    CONCLUSIONS: The overall aim of this case report is to provide a lesson to budding surgeons who might experience a similar situation that cannot be easily explained, like the unexpected complication in the present case.

    Matched MeSH terms: Prosthesis Failure/adverse effects*
  5. Abdullah AH, Todo M, Nakashima Y
    Med Eng Phys, 2017 06;44:8-15.
    PMID: 28373012 DOI: 10.1016/j.medengphy.2017.03.006
    Femoral bone fracture is one of the main causes for the failure of hip arthroplasties (HA). Being subjected to abrupt and high impact forces in daily activities may lead to complex loading configuration such as bending and sideway falls. The objective of this study is to predict the risk of femoral bone fractures in total hip arthroplasty (THA) and resurfacing hip arthroplasty (RHA). A computed tomography (CT) based on finite element analysis was conducted to demonstrate damage formation in a three dimensional model of HAs. The inhomogeneous model of femoral bone was constructed from a 79 year old female patient with hip osteoarthritis complication. Two different femoral components were modeled with titanium alloy and cobalt chromium and inserted into the femoral bones to present THA and RHA models respectively. The analysis included six configurations, which exhibited various loading and boundary conditions, including axial compression, torsion, lateral bending, stance and two types of falling configurations. The applied hip loadings were normalized to body weight (BW) and accumulated from 1 BW to 3 BW. Predictions of damage formation in the femoral models were discussed as the resulting tensile failure as well as the compressive yielding and failure elements. The results indicate that loading directions can forecast the pattern and location of fractures at varying magnitudes of loading. Lateral bending configuration experienced the highest damage formation in both THA and RHA models. Femoral neck and trochanteric regions were in a common location in the RHA model in most configurations, while the predicted fracture locations in THA differed as per the Vancouver classification.
    Matched MeSH terms: Prosthesis Failure*
  6. Mahadeva S, Ranjeev P, Goh KL
    Gastrointest Endosc, 2003 Aug;58(2):295-7.
    PMID: 12872109
    Matched MeSH terms: Prosthesis Failure
  7. Raj JJ, Thompson M, Whitehouse SL, Jaiprakash A, Varughese I, Crawford RW
    Proc Inst Mech Eng H, 2023 Mar;237(3):368-374.
    PMID: 36734414 DOI: 10.1177/09544119231152351
    Standard practice for acetabular component placement in total hip arthroplasty (THA) is to medialise the acetabular component. Bone preservation techniques during primary THA are beneficial for possible future revisions. The goal of this study is to examine the effect of downsizing and minimising medialisation of the acetabular component on bone resection volume. The volume of bone resected during acetabular preparation for different sizes of components was calculated and the volume of bone preserved by downsizing the cup was determined. Minimising medialisation of the acetabular component by 1-3 mm from the true floor was calculated. Absolute values and percentage of bone volume preserved when acetabular components are downsized or less medialised is presented. Downsizing the acetabular component by one size (2 mm) preserves between 2.6 cm3 (size 40 vs 42) and 8.4 cm3 (size 72 vs 74) of bone volume and consistently reduces resected bone volume by at least 35% (range 35.2%-37.5%). Similarly, reducing medialisation of a 56 mm acetabular cup (as an example of a commonly implanted component) by 3 mm reduces bone loss by 5.9 cm3- 44% less bone volume resection. Downsizing and minimising medialisation of the cup in THA substantially preserves bone which may benefit future revision surgeries. Surgeons could consider implanting the smallest acceptable acetabular shell to preserve bone without compromising on head size.
    Matched MeSH terms: Prosthesis Failure
  8. Lim AK, Goh PP, Azura R, Mariam I
    J Cataract Refract Surg, 2011 Apr;37(4):655-9.
    PMID: 21420589 DOI: 10.1016/j.jcrs.2010.10.050
    PURPOSE: To determine the prevalence of and risk factors for AcriFlex 50CSE hydrophilic acrylic intraocular lens (IOL) opacification approximately 3 years after implantation.
    SETTING: Selayang Hospital, Selangor, Malaysia.
    DESIGN: Cross-sectional study.
    METHODS: Patients who had AcriFlex 50CSE IOL implantation in 2005 and 2006 were identified from operating logbooks and recalled via telephone and letters. Opaque IOLs were explanted and sent for scanning electron microscopy (SEM) and energy-dispersive x-ray spectroscopy (EDS).
    RESULTS: The review showed that 18 patients had died and 67 had declined examination or could not be contacted, leaving 239 eyes for evaluation. The age of the patients ranged from 25 to 85 years. Of the patients, 83 (34.7%) were Malay, 127 (53.1%) Chinese, and 29 (12.1%) East Indian. The male:female ratio was 1:1. Fourteen eyes of 13 patients (5.4%) had IOL opacification; 1 had bilateral opacification. Five eyes had fine deposits, and 9 eyes had dense opaque deposits. Seven opaque IOLs required explantation. There was no correlation between age (P=.645), sex (P=.319), or race (P=.860) and IOL opacification. Pearson chi-square analysis showed a strong association between diabetes mellitus and IOL opacification (P=.019). Nine (69.2%) of the 13 patients with opacification had diabetes. Scanning electron microscopy and EDS showed calcium and phosphate deposits on the optic surface and intralenticularly near the anterior surface of the optic.
    CONCLUSIONS: Results indicate that diabetes mellitus is a risk factor for AcriFlex hydrophilic acrylic IOL opacification. In some cases, opacification affected vision, necessitating explantation. The pathophysiology of this complication is unknown.
    FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
    Matched MeSH terms: Prosthesis Failure*
  9. Salamonsen RF, Lim E, Moloney J, Lovell NH, Rosenfeldt FL
    Artif Organs, 2015 Aug;39(8):681-90.
    PMID: 26146861 DOI: 10.1111/aor.12550
    This study in five large greyhound dogs implanted with a VentrAssist left ventricular assist device focused on identification of the precise site and physiological changes induced by or underlying the complication of left ventricular suction. Pressure sensors were placed in left and right atria, proximal and distal left ventricle, and proximal aorta while dual perivascular and tubing ultrasonic flow meters measured blood flow in the aortic root and pump outlet cannula. When suction occurred, end-systolic pressure gradients between proximal and distal regions of the left ventricle on the order of 40-160 mm Hg indicated an occlusive process of variable intensity in the distal ventricle. A variable negative flow difference between end systole and end diastole (0.5-3.4 L/min) was observed. This was presumably mediated by variable apposition of the free and septal walls of the ventricle at the pump inlet cannula orifice which lasted approximately 100 ms. This apposition, by inducing an end-systolic flow deficit, terminated the suction process by relieving the imbalance between pump requirement and delivery from the right ventricle. Immediately preceding this event, however, unnaturally low end-systolic pressures occurred in the left atrium and proximal left ventricle which in four dogs lasted for 80-120 ms. In one dog, however, this collapse progressed to a new level and remained at approximately -5 mm Hg across four heart beats at which point suction was relieved by manual reduction in pump speed. Because these pressures were associated with a pulmonary capillary wedge pressure of -5 mm Hg as well, they indicate total collapse of the entire pulmonary venous system, left atrium, and left ventricle which persisted until pump flow requirement was relieved by reducing pump speed. We suggest that this collapse caused the whole vascular region from pulmonary capillaries to distal left ventricle to behave as a Starling resistance which further reduced right ventricular output thus contributing to a major reduction in pump flow. We contend that similar complications of manual speed control also occur in the human subject and remain a major unsolved problem in the clinical management of patients implanted with rotary blood pumps.
    Matched MeSH terms: Prosthesis Failure*
  10. Ng KL, Nawawi O, Lim BK, Htun TH, Dublin N, Razack AH
    Asian J Surg, 2017 Apr;40(2):171-174.
    PMID: 24210538 DOI: 10.1016/j.asjsur.2013.09.012
    Ureteric strictures are common and can be due to benign or malignant causes. Various surgical treatments can be used from minimally invasive endoscopic retrograde JJ stent insertion, balloon dilatation, ureterolithotomy, to open surgical exploration and repair. Memokath 051 stent is a metallic stent designed for long-term ureteral stenting in the management of ureteral strictures. The insertion of this device is usually a straightforward procedure performed endoscopically in a retrograde fashion via cystoscopy. However, this procedure can be difficult in complicated scenarios when the bladder has been removed with neoureteral reimplantations or high-grade strictures. Here, we report a case of Memokath stent insertion complicated by placement difficulties in a lady with ileal conduit due to previous ovarian cancer complicated by vesicovaginal fistula, who presented with malignant stricture of the ureteroileal anastomosis. We describe a simple yet effective antegrade technique to precisely reposition the malpositioned Memokath stent, along with illustrations.
    Matched MeSH terms: Prosthesis Failure*
  11. Arif M, Sivananthan S, Choon DS
    J Orthop Surg (Hong Kong), 2004 Jun;12(1):25-30.
    PMID: 15237118
    To report the outcome of revised total hip arthroplasty procedures involving an anterior cortical window, extensive strut allografts, and an Exeter impaction graft.
    Matched MeSH terms: Prosthesis Failure*
  12. Merican AM, Randle R
    J Arthroplasty, 2006 Sep;21(6):846-51.
    PMID: 16950037
    The Fitmore titanium mesh cementless acetabular component in 115 hip arthroplasties was reviewed at an average of 33 months of follow-up. None were revised nor had infection. One hip dislocated 4 years postoperatively. Two femoral components were revised. The average Harris Hip Score at the last follow-up was 90 points. In the 96 sets of radiographs available, there was no loosening or new radiolucency. One hip had nonprogressive osteolysis adjacent to a screw. This press-fit cup has its polar region flattened and is rim loading. Noncontact (gaps) at the acetabular floor is expected and is not critical for fixation. In all but 6 hips, these gaps filled. In 5 hips, a minimal gap (
    Matched MeSH terms: Prosthesis Failure
  13. Sivananthan KS, Raveendran K, Kumar T, Sivananthan S
    Injury, 2000 Jul;31(6):433-4.
    PMID: 10831741
    The removal of broken implanted intramedullary nails secondary to re-fracture or non-union is challenging. In 12 cases a simple and safe method has been used to remove broken implants.
    Matched MeSH terms: Prosthesis Failure
  14. Park KS, Seon JK, Lee KB, Kim SK, Chan CK, Yoon TR
    J Arthroplasty, 2017 02;32(2):503-509.
    PMID: 27546473 DOI: 10.1016/j.arth.2016.07.010
    BACKGROUND: This study aims at determining the average long-term result of revision total hip arthroplasty (THA) using the acetabular reinforcement ring with a hook (ARRH) and bone grafting in severe acetabular bony defect. Expected 15-year survival of ARRH in revision THA is included in the study.

    METHODS: Retrospective review of 48 patients (48 hips) with follow-up duration of average 11.4 years (range, 6.1-21.4 years) was conducted. At each follow-up, Harris hip score was used to assess functional outcome, and radiographic acetabular component osteolysis was measured by DeLee and Charnley classification. Bone defects were assessed preoperatively and intraoperatively using American academy of orthopedic surgeons and Paprosky classification. The common modes of ARRH failures were evaluated. Bone consolidation, presence of heterotopic ossification, and complications such as infection and dislocation were recorded.

    RESULTS: The bone defects were varied and included cavitary, segmental, and combined defects without any pelvic discontinuity. Mean Harris hip score improved from 52.6 points preoperatively to 82.0 points postoperatively. Nine acetabular revisions and 3 stem revisions (2 concurrent with acetabular revisions and 1 isolated stem revision) were performed. There were 5 infected cases and 1 patient with recurrent dislocation. The 11.4-year survival of revision THA with ARRH was 71% as the end point for acetabular revision surgery for any reason. The expected 15-year survival of revision THA with ARRH was 60%. The most common failure mode of ARRH was superomedial migration followed by lateral migration.

    CONCLUSION: ARRH combined with bone grafting produces relatively good average long-term clinical results.

    Matched MeSH terms: Prosthesis Failure
  15. Duray GZ, Ritter P, El-Chami M, Narasimhan C, Omar R, Tolosana JM, et al.
    Heart Rhythm, 2017 05;14(5):702-709.
    PMID: 28192207 DOI: 10.1016/j.hrthm.2017.01.035
    BACKGROUND: Early performance of the Micra transcatheter pacemaker from the global clinical trial reported a 99.2% implant success rate, low and stable pacing capture thresholds, and a low (4.0%) rate of major complications up to 6 months.

    OBJECTIVE: The purpose of this report was to describe the prespecified long-term safety objective of Micra at 12 months and electrical performance through 24 months.

    METHODS: The Micra Transcatheter Pacing Study was a prospective single-arm study designed to assess the safety and efficacy of the Micra VVIR leadless/intracardiac pacemaker. Enrolled patients met class I or II guideline recommendations for de novo ventricular pacing. The long-term safety objective was freedom from a system- or procedure-related major complication at 12 months. A predefined historical control group of 2667 patients with transvenous pacemakers was used to compare major complication rates.

    RESULTS: The long-term safety objective was achieved with a freedom from major complication rate of 96.0% at 12 months (95% confidence interval 94.2%-97.2%; P < .0001 vs performance goal). The risk of major complications for patients with Micra (N = 726) was 48% lower than that for patients with transvenous systems through 12 months postimplant (hazard ratio 0.52; 95% confidence interval 0.35-0.77; P = .001). Across subgroups of age, sex, and comorbidities, Micra reduced the risk of major complications compared to transvenous systems. Electrical performance was excellent through 24 months, with a projected battery longevity of 12.1 years.

    CONCLUSION: Long-term performance of the Micra transcatheter pacemaker remains consistent with previously reported data. Few patients experienced major complications through 12 months of follow-up, and all patient subgroups benefited as compared to transvenous pacemaker historical control group.

    Matched MeSH terms: Prosthesis Failure
  16. Ajit Singh V, Ying Jing O, Santharalinggam RD, Yasin NF
    J Orthop Surg (Hong Kong), 2024;32(3):10225536241306917.
    PMID: 39629838 DOI: 10.1177/10225536241306917
    Background: Bipolar hip endoprosthesis replacement is a commonly employed procedure in orthopaedic oncology that requires the resection and reconstruction of the proximal femur. With improving survival rates, issues of implant durability and acetabular wear have become increasingly important. The decision to replace the acetabulum in bipolar hip endoprosthesis replacement procedures remains a topic of debate. Aim: This study aimed to assess the prevalence of secondary osteoarthritis following bipolar hip replacement, the need for revision to total joint replacement post-procedure, the functional status of patients in relation to radiological findings of joint degeneration, and the survivorship of bipolar hip replacements. Methods: Patients with orthopaedic oncology cases who underwent bipolar hip endoprosthesis replacement between 2006 and October 2021, with a minimum follow-up of six months, were included. Both clinical and radiological evaluations were carried out. The clinical evaluation utilised the Musculoskeletal Tumor Society (MSTS), Toronto Extremity Salvage Score (TESS), and modified Harris Hip Score (mHHS) systems. The radiological assessment focused on identifying acetabular erosion. Results: Forty eligible patients were identified. Radiological assessments revealed 21 patients (52.5%) with grade 0, 17 patients (42.5%) with grade 1, and 2 patients (5.0%) with grade 2 acetabular erosion. No patients exhibited grade 3 acetabular erosion. One patient (2.5%) required revision surgery from proximal femoral bipolar replacement to total hip replacement due to recurrent postoperative hip dislocation. There was no statistically significant difference in MSTS and mHHS scores but a significant difference in TESS scores. The ten-year implant survival rate was 77.8%, while the overall patient survivorship at ten years was 72.1%. Conclusion: Bipolar hip replacement is a durable limb-preserving reconstruction that can outlast patients' lifespans and is well-tolerated by oncology patients. The incidence of acetabular erosion and revision surgery is low. Despite radiological evidence of hip degeneration, functional status in patients is not significantly impacted.
    Matched MeSH terms: Prosthesis Failure
  17. Riahi M, Ang HL, Jones M, Prachasilchai P, Baruteau AE, Promphan W, et al.
    Circ Cardiovasc Interv, 2018 04;11(4):e005923.
    PMID: 29618579 DOI: 10.1161/CIRCINTERVENTIONS.117.005923
    Matched MeSH terms: Prosthesis Failure*
  18. Yong CK, Choon DS, Soon HC
    J Orthop Surg (Hong Kong), 2008 Aug;16(2):197-200.
    PMID: 18725672
    To present midterm results of Duracon total knee arthroplasty (TKA) performed between 1991 and 2001.
    Matched MeSH terms: Prosthesis Failure