Displaying publications 1 - 20 of 41 in total

Abstract:
Sort:
  1. May IJ, Nowak AK, Francis RJ, Ebert MA, Dhaliwal SS
    J Med Imaging Radiat Oncol, 2024 Feb;68(1):57-66.
    PMID: 37898984 DOI: 10.1111/1754-9485.13592
    INTRODUCTION: Malignant pleural mesothelioma is difficult to prognosticate. F18-Fluorodeoxyglucose positron emission tomography (FDG PET) shows promise for response assessment but is confounded by talc pleurodesis. F18-Fluorothymidine (FLT) PET is an alternative tracer specific for proliferation. We compared the prognostic value of FDG and FLT PET and determined the influence of talc pleurodesis on these parameters.

    METHODS: Overall, 29 prospectively recruited patients had FLT PET, FDG PET and CT-scans performed prior to and post one chemotherapy cycle; 10 had prior talc pleurodesis. Patients were followed for overall survival. CT response was assessed using mRECIST. Radiomic features were extracted using the MiM software platform. Changes in maximum SUV (SUVmax), mean SUV (SUVmean), FDG total lesion glycolysis (TLG), FLT total lesion proliferation (TLP) and metabolic tumour volume (MTV) after one chemotherapy cycle.

    RESULTS: Cox univariate analysis demonstrated FDG PET radiomics were confounded by talc pleurodesis, and that percentage change in FLT MTV was predictive of overall survival. Cox multivariate analysis showed a 10% increase in FLT tumour volume corresponded with 9.5% worsened odds for overall survival (P = 0.028, HR = 1.095, 95% CI [1.010, 1.187]). No other variables were significant on multivariate analysis.

    CONCLUSION: This is the first prospective study showing the statistical significance of FLT PET tumour volumes for measuring mesothelioma treatment response. FLT may be better than FDG for monitoring mesothelioma treatment response, which could help optimise mesothelioma treatment regimes.

    Matched MeSH terms: Positron-Emission Tomography/methods; Positron Emission Tomography Computed Tomography/methods
  2. Robson RE, Brunger MJ, Buckman SJ, Garcia G, Petrović ZLj, White RD
    Sci Rep, 2015 Aug 06;5:12674.
    PMID: 26246002 DOI: 10.1038/srep12674
    The kinetic theory of non-relativistic positrons in an idealized positron emission tomography PET environment is developed by solving the Boltzmann equation, allowing for coherent and incoherent elastic, inelastic, ionizing and annihilating collisions through positronium formation. An analytic expression is obtained for the positronium formation rate, as a function of distance from a spherical source, in terms of the solutions of the general kinetic eigenvalue problem. Numerical estimates of the positron range - a fundamental limitation on the accuracy of PET, are given for positrons in a model of liquid water, a surrogate for human tissue. Comparisons are made with the 'gas-phase' assumption used in current models in which coherent scattering is suppressed. Our results show that this assumption leads to an error of the order of a factor of approximately 2, emphasizing the need to accurately account for the structure of the medium in PET simulations.
    Matched MeSH terms: Positron-Emission Tomography/methods*
  3. Mohd Rohani MF, Zanial AZ, Suppiah S, Phay Phay K, Mohamed Aslum Khan F, Mohamad Najib FH, et al.
    Nucl Med Commun, 2021 Jan;42(1):9-20.
    PMID: 33165258 DOI: 10.1097/MNM.0000000000001306
    Skeletal whole-body scintigraphy (WBS), although widely used as a sensitive tool for detecting metastatic bone disease in oncology cases, has relatively low specificity. Indeterminate bone lesions (IBLs) detected by WBS cause a diagnostic dilemma, which hampers further management plans. In the advent of hybrid imaging, single-photon emission computed tomography/computed tomography (SPECT/CT) has been gaining popularity as a tool to improve the characterisation of IBLs detected by WBS. As yet, there has not been a systematic review to objectively evaluate the diagnostic capabilities of SPECT/CT in this area. We conducted a systematic review of relevant electronic databases up to 30 August 2020. The outcomes of interest were the reporting of SPECT/CT to identify benign and malignant IBLs and the calculation of the sensitivity and specificity of the index test, based on histopathological examination or clinical and imaging follow-up as the reference standard. After the risk of bias and eligibility assessment, 12 articles were identified and synthesised in the meta-analysis. The pooled sensitivity and specificity of SPECT/CT for diagnosing IBLs are 93.0% [95% confidence interval (CI) 0.91-0.95] and 96.0% (95% CI 0.94-0.97), respectively. There was heterogeneity of the articles due to variable imaging protocols, duration of follow-up and scoring methods for interpreting the SPECT/CT results. The heterogeneity poses a challenge for accurate interpretation of the true diagnostic capability of SPECT/CT. In conclusion, targeted SPECT/CT improves the specificity of diagnosing bone metastases, but efforts need to be made to standardise the thresholds for SPECT/CT, methodology, as well as harmonising the reporting and interpretation criteria. We also make some recommendations for future works.
    Matched MeSH terms: Single Photon Emission Computed Tomography Computed Tomography/methods*
  4. Al-Siweedi SYA, Ngeow WC, Nambiar P, Abu-Hassan MI, Ahmad R, Asif MK, et al.
    Folia Morphol (Warsz), 2023;82(2):315-324.
    PMID: 35285511 DOI: 10.5603/FM.a2022.0024
    BACKGROUND: The purpose of this study was to identify and classify the anatomic variation of mandibular canal among Malaysians of three ethnicities.

    MATERIALS AND METHODS: The courses of the mandibular canal in 202 cone-beam computed tomography scanned images of healthy Malaysians were evaluated, and trifid mandibular canal (TMC) when present, were recorded and studied in detail by categorizing them to a new classification (comprising of 12 types). The diameter and length of canals were also measured, and their shape determined.

    RESULTS: Trifid mandibular canals were observed in 12 (5.9%) subjects or 16 (4.0%) hemi-mandibles. There were 10 obvious categories out the 12 types of TMCs listed. All TMCs (except one) were observed in patients older than 30 years. The prevalence according to ethnicity was 6 in Malays, 5 in Chinese and 1 in Indian. Four (33.3%) patients had bilateral TMCs, which was not seen in the Indian subject. More than half (56.3%) of the accessory canals were located above the main mandibular canal. Their mean diameter was 1.32 mm and 1.26 mm for the first and second accessory canal, and the corresponding lengths were 20.42 mm and 21.60 mm, respectively. Most (62.5%) canals had irregularly shaped lumen; there were more irregularly shaped canals in the second accessory canal than the first branch. None of the second accessory canal was oval (in shape).

    CONCLUSIONS: This new classification can be applied for the variations in the branching pattern, length and shape of TMCs for better clinical description.

    Matched MeSH terms: Cone-Beam Computed Tomography/methods
  5. Hatipoğlu FP, Mağat G, Hatipoğlu Ö, Al-Khatib H, Elatrash AS, Abidin IZ, et al.
    J Endod, 2023 Oct;49(10):1308-1318.
    PMID: 37393948 DOI: 10.1016/j.joen.2023.06.011
    AIM: The aim of this study was two-folded: i) to assess the prevalence of Distolingual Canal (DLC) and Radix Entomolaris (RE) in Mandibular First Molars (M1Ms), using Cone Beam Computed Tomography (CBCT) images and ii) to assess the impact of sociodemographic factors on the prevalence of these conditions worldwide.

    METHODS: CBCT images were scanned retrospectively and the ones including bilateral M1Ms were included in the study. The evaluation was performed by 1 researcher in each country, trained with CBCT technology. A written and video instruction program explaining the protocol to be followed step-by-step was provided to all observers to calibrate them. The CBCT imaging screening procedure consisted of evaluating axial sections from coronal to apical. The presence of DLC and RE in M1Ms (yes/no) was identified and recorded.

    RESULTS: Six thousand three hundred four CBCTs, representing 12,608 M1Ms, were evaluated. A significant difference was found between countries regarding the prevalence of both RE and DLC (P  .05).

    CONCLUSION: The overall prevalence of RE and DLC in M1Ms was 3% and 22%. Additionally, both RE and DLC showed substantial bilaterally. These variations should be considered by endodontic clinicians during endodontic procedures in order to avoid potential complications.

    Matched MeSH terms: Cone-Beam Computed Tomography/methods
  6. Ren X, Nur Salihin Yusoff M, Hartini Mohd Taib N, Zhang L, Wang K
    Eur J Radiol, 2024 Jan;170:111274.
    PMID: 38147764 DOI: 10.1016/j.ejrad.2023.111274
    PURPOSE: The goal of this study was to evaluate the effectiveness of two diagnostic methods, 68Ga-PSMA-11 PET/CT and mpMRI, in detecting primary prostate cancer without limitations on the Gleason score.

    METHODS: We conducted a comprehensive literature review, searching databases such as PubMed, Embase, and Web of Science until June 2023. Our objective was to identify studies that compared the efficacy of 68Ga-PSMA-11 PET/CT and mpMRI in detecting primary prostate cancer. To determine heterogeneity, the I2 statistic was used. Meta-regression analysis and leave-one-out sensitivity analysis were conducted to identify potential sources of heterogeneity.

    RESULTS: Initially, 1286 publications were found, but after careful evaluation, only 16 studies involving 1227 patients were analyzed thoroughly. The results showed that the 68Ga-PSMA-11 PET/CT method had a pooled sensitivity and specificity of 0.87 (95 % CI: 0.80-0.92) and 0.80 (95 % CI: 0.69-0.89), respectively, for diagnosing prostatic cancer. Similarly, the values for mpMRI were determined as 0.84 (95 % CI: 0.75-0.92) and 0.74 (95 % CI: 0.61-0.86), respectively. There were no significant differences in diagnostic effectiveness observed when comparing two primary prostate cancer methodologies (pooled sensitivity P = 0.62, pooled specificity P = 0.50). Despite this, the funnel plots showed symmetry and the Egger test results (P values > 0.05) suggested there was no publication bias.

    CONCLUSIONS: After an extensive meta-analysis, it was found that both 68Ga-PSMA-11 PET/CT and mpMRI demonstrate similar diagnostic effectiveness in detecting primary prostate cancer. Future larger prospective studies are warranted to investigate this issue further.

    Matched MeSH terms: Positron Emission Tomography Computed Tomography/methods
  7. Joshi SC, Pant I, Hamzah F, Kumar G, Shukla AN
    Indian J Cancer, 2008 12 30;45(4):137-41.
    PMID: 19112200
    Positron emission tomography (PET) has emerged as an important diagnostic tool in the management of lung cancers. Although PET is sensitive in detection of lung cancer, but FDG (2-deoxy-2- 18 fluro-D-glucose) is not tumor specific and may accumulate in a variety of nonmalignant conditions occasionally giving false positive result. Addition of CT to PET improves specificity foremost, but also sensitivity in tumor imaging. Thus, PET/CT fusion images are a more accurate test than either of its individual components and are probably also better than side-by-side viewing of images from both modalities. PET/CT fusion images are useful in differentiating between malignant and benign disease, fibrosis and recurrence, staging and in changing patient management to more appropriate therapy. With analysis and discussion it appears that PET/ CT fusion images have the potential to dramatically improve our ability to manage the patients with lung cancer and is contributing to our understanding of cancer cell biology and in development of new therapies.
    Matched MeSH terms: Positron-Emission Tomography/methods*
  8. Abdullah MZ, Yin W, Bilal M, Armitage DW, Mackin R, Peyton AJ
    Rev Sci Instrum, 2007 Aug;78(8):084703.
    PMID: 17764343
    This article addresses time-domain ultrawide band (UWB) electromagnetic tomography for reconstructing the unknown spatial characteristic of an object from observations of the arrivals of short electromagnetic (EM) pulses. Here, the determination of the first peak arrival of the EM traces constitutes the forward problem, and the inverse problem aims to reconstruct the EM property distribution of the media. In this article, the finite-difference time-domain method implementing a perfectly matched layer is used to solve the forward problem from which the system sensitivity maps are determined. Image reconstruction is based on the combination of a linearized update and regularized Landweber minimization algorithm. Experimental data from a laboratory UWB system using targets of different contrasts, sizes, and shapes in an aqueous media are presented. The results show that this technique can accurately detect and locate unknown targets in spite of the presence of significant levels of noise in the data.
    Matched MeSH terms: Tomography/methods*
  9. Tooyama I, Yanagisawa D, Taguchi H, Kato T, Hirao K, Shirai N, et al.
    Ageing Res Rev, 2016 09;30:85-94.
    PMID: 26772439 DOI: 10.1016/j.arr.2015.12.008
    The formation of senile plaques followed by the deposition of amyloid-β is the earliest pathological change in Alzheimer's disease. Thus, the detection of senile plaques remains the most important early diagnostic indicator of Alzheimer's disease. Amyloid imaging is a noninvasive technique for visualizing senile plaques in the brains of Alzheimer's patients using positron emission tomography (PET) or magnetic resonance imaging (MRI). Because fluorine-19 ((19)F) displays an intense nuclear magnetic resonance signal and is almost non-existent in the body, targets are detected with a higher signal-to-noise ratio using appropriate fluorinated contrast agents. The recent introduction of high-field MRI allows us to detect amyloid depositions in the brain of living mouse using (19)F-MRI. So far, at least three probes have been reported to detect amyloid deposition in the brain of transgenic mouse models of Alzheimer's disease; (E,E)-1-fluoro-2,5-bis-(3-hydroxycarbonyl-4-hydroxy)styrylbenzene (FSB), 1,7-bis(4'-hydroxy-3'-trifluoromethoxyphenyl)-4-methoxycarbonylethyl-1,6-heptadiene3,5-dione (FMeC1, Shiga-Y5) and 6-(3',6',9',15',18',21'-heptaoxa-23',23',23'-trifluorotricosanyloxy)-2-(4'-dimethylaminostyryl)benzoxazole (XP7, Shiga-X22). This review presents the recent advances in amyloid imaging using (19)F-MRI, including our own studies.
    Matched MeSH terms: Positron-Emission Tomography/methods*
  10. Muhammad AMA, Ibrahim N, Ahmad R, Asif MK, Radzi Z, Zaini ZM, et al.
    BMC Oral Health, 2020 02 10;20(1):48.
    PMID: 32041589 DOI: 10.1186/s12903-020-1035-7
    BACKGROUND: Cone Beam Computed Tomography (CBCT) is a reliable radiographic modality to assess trabecular bone microarchitecture. The aim of this study was to determine the effect of CBCT image reconstruction parameters, namely, the threshold value and reconstruction voxel size, on trabecular bone microstructure assessment.

    METHODS: Five sectioned maxilla of adult Dorper male sheep were scanned using a CBCT system with a resolution of 76 μm3 (Kodak 9000). The CBCT images were reconstructed using different reconstruction parameters and analysed. The effect of reconstruction voxel size (76, 100 and 200 μm3) and threshold values (±15% from the global threshold value) on trabecular bone microstructure measurement was assessed using image analysis software (CT analyser version 1.15).

    RESULTS: There was no significant difference in trabecular bone microstructure measurement between the reconstruction voxel sizes, but a significant difference (Tb.N = 0.03, Tb.Sp = 0.04, Tb.Th = 0.01, BV/TV = 0.00) was apparent when the global threshold value was decreased by 15%.

    CONCLUSIONS: Trabecular bone microstructure measurements are not compromised by changing the CBCT reconstruction voxel size. However, measurements can be affected when applying a threshold value of less than 15% of the recommended global value.

    Matched MeSH terms: Cone-Beam Computed Tomography/methods*
  11. Hassan H, Othman MF, Abdul Razak HR, Zakaria ZA, Ahmad Saad FF, Osman MA, et al.
    Molecules, 2022 Nov 17;27(22).
    PMID: 36432069 DOI: 10.3390/molecules27227969
    [18F]sodium fluoride ([18F]NaF) is recognised to be superior to [99mTc]-methyl diphosphate ([99mTc]Tc-MDP) and 2-deoxy-2-[18F]fluoro-D-glucose ([18F]FDG) in bone imaging. However, there is concern that [18F]NaF uptake is not cancer-specific, leading to a higher number of false-positive interpretations. Therefore, in this work, [18F]AlF-NOTA-pamidronic acid was prepared, optimised, and tested for its in vitro uptake. NOTA-pamidronic acid was prepared by an N-Hydroxysuccinimide (NHS) ester strategy and validated by liquid chromatography-mass spectrometry analysis (LC-MS/MS). Radiolabeling of [18F]AlF-NOTA-pamidronic acid was optimised, and it was ensured that all quality control analysis requirements for the radiopharmaceuticals were met prior to the in vitro cell uptake studies. NOTA-pamidronic acid was successfully prepared and radiolabeled with 18F. The radiolabel was prepared in a 1:1 molar ratio of aluminium chloride (AlCl3) to NOTA-pamidronic acid and heated at 100 °C for 15 min in the presence of 50% ethanol (v/v), which proved to be optimal. The preliminary in vitro results of the binding of the hydroxyapatite showed that [18F]AlF-NOTA-pamidronic acid was as sensitive as [18F]sodium fluoride ([18F]NaF). Normal human osteoblast cell lines (hFOB 1.19) and human osteosarcoma cell lines (Saos-2) were used for the in vitro cellular uptake studies. It was found that [18F]NaF was higher in both cell lines, but [18F]AlF-NOTA-pamidronic acid showed promising cellular uptake in Saos-2. The preliminary results suggest that further preclinical studies of [18F]AlF-NOTA-pamidronic acid are needed before it is transferred to clinical research.
    Matched MeSH terms: Positron-Emission Tomography/methods
  12. Rabba JA, Suhaimi FM, Mat Jafri MZ, Jaafar HA, Osman ND
    Radiography (Lond), 2023 May;29(3):533-538.
    PMID: 36913788 DOI: 10.1016/j.radi.2023.02.028
    INTRODUCTION: The daily image quality assessment involves large datasets that consume a lot of time and effort. This study aims to evaluate a proposed automated calculator for image distortion analysis in 2-dimensional (2D) panoramic imaging mode for a dental cone beam computed tomography (CBCT) system in comparison with present manual calculations.

    METHODS: A ball phantom was scanned using panoramic mode of the Planmeca ProMax 3D Mid CBCT unit (Planmeca, Helsinki, Finland) with standard exposure settings used in clinical practice (60 kV, 2 mA, and maximum FOV). An automated calculator algorithm was developed in MATLAB platform. Two parameters associated with panoramic image distortion such as balls diameter and distance between middle and tenth balls were measured. These automated measurements were compared with manual measurement using the Planmeca Romexis and ImageJ software.

    RESULTS: The findings showed smaller deviation in distance difference measurements by proposed automated calculator (ranged 3.83 mm) as compared to manual measurements (ranged 5.00 for Romexis and 5.12 mm for ImageJ software). There was a significant difference (p 

    Matched MeSH terms: Cone-Beam Computed Tomography/methods
  13. Ishak MH, Zhun OC, Shaari R, Rahman SA, Hasan MN, Alam MK
    Mymensingh Med J, 2014 Oct;23(4):781-6.
    PMID: 25481601
    This study evaluated the validity of panoramic radiography and cone beam computed tomography (CBCT) in the assessment of mandibular canal and impacted third molar. In this descriptive-analytical study, 58 mandibular third molars from 42 patients who showed a close relationship between impacted third molar and canal on panoramic radiographs were selected. They were then classified into seven radiographic markers in panoramic radiographs (superimposition, darkening of the root, interruption of the white lines, root narrowing, canal diversion, canal narrowing, and also closed distance in OPG <1mm). The groups of markers were further assessed with CBCT to see presence or absence of contact. The three most common markers seen in panoramic images are superimposition, interruption of white line and root darkening. In CBCT, superimposition marker always presented higher frequency of contact with canal compared to non-contact group. There are 31% of teeth presented with interruption of white lines and there are 29.3% of teeth presented with superimposition. About 55.6% and 35.3% of the impacted mandibular third molars which indicated interruption of white lines and superimposition also indicated contact in the CBCT respectively. Presence or absence of radiological sign in panoramic radiography was not properly predict a close relationship with third molar and it is suggested that in case of tooth-canal overlapping, the patient should be referred for CBCT assessment.
    Matched MeSH terms: Cone-Beam Computed Tomography/methods*
  14. Juliana N, Shahar S, Chelliah KK, Ghazali AR, Osman F, Sahar MA
    Asian Pac J Cancer Prev, 2014;15(14):5759-65.
    PMID: 25081698
    Electrical impedance tomography (EIT) is a potential supplement for mammogram screening. This study aimed to evaluate and feasibility of EIT as opposed to mammography and to determine pain perception with both imaging methods. Women undergoing screening mammography at the Radiology Department of National University of Malaysia Medical Centre were randomly selected for EIT imaging. All women were requested to give a pain score after each imaging session. Two independent raters were chosen to define the image findings of EIT. A total of 164 women in the age range from 40 to 65-year-old participated and were divided into two groups; normal and abnormal. EIT sensitivity and specificity for rater 1 were 69.4% and 63.3, whereas for rater 2 they were 55.3% and 57.0% respectively. The reliability for each rater ranged between good to very good (p<0.05). Quantitative values of EIT showed there were significant differences in all values between groups (ANCOVA, p<0.05). Interestingly, EIT scored a median pain score of 1.51±0.75 whereas mammography scored 4.15±0.87 (Mann Whitney U test, p<0.05). From these quantitative values, EIT has the potential as a health discriminating index. Its ability to replace image findings from mammography needs further investigation.
    Matched MeSH terms: Tomography/methods*
  15. Anderson PJ, Yong R, Surman TL, Rajion ZA, Ranjitkar S
    Aust Dent J, 2014 Jun;59 Suppl 1:174-85.
    PMID: 24611727 DOI: 10.1111/adj.12154
    Following the invention of the first computed tomography (CT) scanner in the early 1970s, many innovations in three-dimensional (3D) diagnostic imaging technology have occurred, leading to a wide range of applications in craniofacial clinical practice and research. Three-dimensional image analysis provides superior and more detailed information compared with conventional plain two-dimensional (2D) radiography, with the added benefit of 3D printing for preoperative treatment planning and regenerative therapy. Current state-of-the-art multidetector CT (MDCT), also known as medical CT, has an important role in the diagnosis and management of craniofacial injuries and pathology. Three-dimensional cone beam CT (CBCT), pioneered in the 1990s, is gaining increasing popularity in dental and craniofacial clinical practice because of its faster image acquisition at a lower radiation dose, but sound guidelines are needed to ensure its optimal clinical use. Recent innovations in micro-computed tomography (micro-CT) have revolutionized craniofacial biology research by enabling higher resolution scanning of teeth beyond the capabilities of MDCT and CBCT, presenting new prospects for translational clinical research. Even after four decades of refinement, CT technology continues to advance and broaden the horizons of craniofacial clinical practice and phenomics research.
    Matched MeSH terms: Multidetector Computed Tomography/methods
  16. Songib NA, Nazri M, Yaakup NA, Nor HM, Sun Z
    Clin Imaging, 2013 Nov-Dec;37(6):1037-42.
    PMID: 24035803 DOI: 10.1016/j.clinimag.2013.08.005
    The aim of this study is to investigate the feasibility of eliminating the nephrographic phase from the four-phase renal computed tomography (CT) imaging to a three-phase protocol without affecting its diagnostic value. Thirty patients undergoing four-phase renal CT scans for assessment of renal lesions (>10 mm) were included in the study. A three-phase renal CT, without nephrographic phase, had similar diagnostic ability to a four-phase renal CT in the detection and characterization of renal lesions. A three-phase CT (plain, corticomedullary, and excretory phase) is therefore adequate in the clinical diagnosis of renal lesions.
    Matched MeSH terms: Multidetector Computed Tomography/methods*
  17. Abu Bakar N, Abdul Aziz YF, Singh Sandhu R, Fadzli F, Yaakub NA, Krishnasamy S, et al.
    Heart Lung Circ, 2013 Apr;22(4):305-8.
    PMID: 22921797 DOI: 10.1016/j.hlc.2012.07.016
    Pericardial cysts are uncommon mediastinal lesions that are usually congenital in origin. Patients are usually asymptomatic and the cysts are generally discovered on routine radiography for unrelated purposes. This case illustrates a symptomatic presentation of a haemorrhagic pericardial cyst in which radiographic, echocardiographic and multislice (MRI and CT) imaging were performed. The imaging findings were not typical of pericardial cysts leading to a diagnostic quandary despite the varied imaging techniques. In conclusion, it is important to appreciate that the imaging findings of pericardial cysts can be varied. Radiologists and clinicians alike should be aware of this variability.
    Matched MeSH terms: Multidetector Computed Tomography/methods
  18. Nordin AJ, Rossetti C, Rahim NA
    Eur. J. Nucl. Med. Mol. Imaging, 2009 May;36(5):882.
    PMID: 19296106 DOI: 10.1007/s00259-009-1107-z
    Matched MeSH terms: Positron-Emission Tomography/methods*
  19. Al-koshab M, Nambiar P, John J
    PLoS One, 2015;10(3):e0121682.
    PMID: 25803868 DOI: 10.1371/journal.pone.0121682
    INTRODUCTION: Proper imaging allows practitioners to evaluate an asymptomatic tempormandibular joint (TMJ) for potential degenerative changes prior to surgical and orthodontic treatment. The recently developed cone-beam computed tomography (CBCT) allows measurement of TMJ bony structures with high accuracy. A study was undertaken to determine the morphology, and its variations, of the mandibular condyle and glenoid fossa among Malay and Chinese Malaysians.

    METHODS: CBCT was used to assess 200 joints in 100 subjects (mean age, 30.5 years). i-CAT CBCT software and The Mimics 16.0 software were employed to measure the volume, metrical size, position of each condyle sample and the thickness of the roof of the glenoid fossa (RGF).

    RESULTS: No significant gender differences were noted in thickness of the RGF and condylar length; however condylar volume, width, height and the joint spaces were significantly greater among males. With regards to comparison of both TMJs, the means of condylar volume, width and length of the right TMJ were significantly higher, while the means of the left condylar height and thickness of RGF were higher. When comparing the condylar measurements and the thickness of RGF between the two ethnic groups, we found no significant difference for all measurements with exception of condylar height, which is higher among Chinese.

    CONCLUSION: The similarity in measurements for Malays and Chinese may be due to their common origin. This information can be clinically useful in establishing the diagnostic criteria for condylar volume, metrical size, and position in the Malaysian East Asians population.

    Matched MeSH terms: Cone-Beam Computed Tomography/methods*
  20. Ling LL, Hsu CC, Yong CC, Elsarawy AM, Chan YC, Wang CC, et al.
    Int J Surg, 2019 Sep;69:124-131.
    PMID: 31386913 DOI: 10.1016/j.ijsu.2019.07.035
    BACKGROUND: Tumor histology affects outcome after liver transplantation (LT) for hepatocellular carcinoma (HCC). This study explores the association between F-18 fluorodeoxyglucose positron emission tomography (FDG-PET) and tumor histology in living donor liver transplantation (LDLT) recipients and their outcome.

    MATERIALS AND METHODS: Two hundred fifty-eight patients with primary liver tumors who underwent FDG-PET before LDLT were enrolled in this retrospective study. Unfavorable tumor histology was defined as primary liver tumor other than a well- or moderately differentiated HCC. Thirteen patients had unfavorable tumor histology, including 2 poorly differentiated HCC, 2 sarcomatoid HCC, 5 combined hepatocellular cholangiocarcinoma, 3 intrahepatic cholangiocarcinoma, and 1 hilar cholangiocarcinoma.

    RESULTS: FDG-PET positivity was significantly associated with unfavorable tumor histology (P < 0.001). Both FDG-PET positivity and unfavorable tumor histology were significant independent predictors of tumor recurrence and overall survival. In a subgroup analysis of patients with FDG-PET-positive tumors, unfavorable tumor histology was a significant independent predictor of tumor recurrence and overall survival. High FDG uptake (tumor to non-tumor uptake ratio ≥ 2) was a significant predictor of unfavorable tumor histology. Patients with high FDG uptake and/or unfavorable tumors had significantly higher 3-year cumulative recurrence rate (70.8% versus 26.2%, P = 0.004) and worse 3-year overall survival (34.1% versus 70.8%, P = 0.012) compared to those with low FDG uptake favorable tumors.

    CONCLUSIONS: The expression of FDG-PET is highly associated with histology of explanted HCC and predicts the recurrence. FDG-PET-positive tumors with high FDG uptake may be considered contraindication for LDLT due to high recurrence rate except when pathology proves favorable histology.

    Matched MeSH terms: Positron-Emission Tomography/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links