Displaying publications 1 - 20 of 21 in total

Abstract:
Sort:
  1. Jin NZ, Gopinath SCB
    Biomed Pharmacother, 2016 Dec;84:356-365.
    PMID: 27668535 DOI: 10.1016/j.biopha.2016.09.057
    Hemostasis initiates a wound healing process and stops bleeding of blood within a damaged tissue, an important process in human and animal systems. However, this process needs to revert temporarily during surgery and analyze the clotting mechanism. In the past decade, heparin has been used widely as an anticoagulant in surgery to prevent unwanted blood clotting as it is not expensive, not difficult to control, lack of suitable replacement as well as less harmful to the human. However, heparin has several disadvantages, which include thrombocytopenia and non-specific plasma binding. Moreover, using heparin it may lead dysfunction and platelet aggregation. In this overview, potential clotting factors and anticoagulants are reviewed and special focus was given to get more insights.
    Matched MeSH terms: Factor IX/metabolism
  2. Krishnan H, Gopinath SCB, Md Arshad MK, Zulhaimi HI, Ramanathan S
    Mikrochim Acta, 2021 03 31;188(4):144.
    PMID: 33791872 DOI: 10.1007/s00604-021-04794-1
    A conventional photolithography technique was used to fabricate three types of Archimedean-spiral interdigitated electrodes (AIDEs) containing concentric interlocking electrodes with different electrode and gap sizes, i.e., 150 μm (D1), 100 μm (D2), and 50 μm (D3). The precision of the fabrication was validated by surface topography using scanning electron microscopy, high power microscopy, 3D-nano profilometry, and atomic force microscopy. These AIDEs were fabricated with a tolerance of ± 6 nm in dimensions. The insignificant current variation at the pico-ampere range for all bare AIDEs further proved the reproducibility of the device. The large gap sized AIDE (D1) is insensitive to acidic medium, whereas D2 and D3 are insensitive to alkali medium. D2 was the best with regard to its electrical characterization. Furthermore, uniformly synthesized molecularly imprinted polymer (MIP) nanoparticles prepared with human blood clotting factor IX and its aptamer were in the size range 140 to 160 nm, attached on the sensing surface and characterized. The average thickness of deposited MIP film was 1.7 μm. EDX data shows the prominent peaks for silicon and aluminum substrates as 61.79 and 22.52%, respectively. The MIP nanoparticles-deposited sensor surface was characterized by applying it in electrolyte solutions, and smooth curves with the current flow were observed at pH lower than 8 and discriminated against alkali media. This study provides a new MIP amalgamated AIDE with nano-gapped fingers enabling analysis of other biomaterials due to its operation in an ideal buffer range.
    Matched MeSH terms: Factor IX/analysis; Factor IX/chemistry
  3. Balraj P, Ahmad M, Khoo AS, Ayob Y
    Malays J Pathol, 2012 Jun;34(1):67-9.
    PMID: 22870602 MyJurnal
    Haemophilia B is caused by coagulation defects in the factor IX gene located in Xq27.1 on the X chromosome. Identification of mutations contributing to defective factor IX may be advantageous for precise carrier and prenatal diagnosis. We studied 16 patients from 11 families, consisting of 8 patients of the Malay ethnic group, of which 6 were siblings. Factor IX mutations have not been previously reported in the Malay ethnic group. The functional region of the factor IX gene was sequenced and mutations were identified in either the exon or intronic regions in 15 of the patients. One novel mutation, 6660_6664delTTCTT was identified in siblings with moderate form of haemophilia B. Mutations identified in our patients when linked with disease severity were similar to findings in other populations. In summary, this preliminary data will be used to build a Malaysian mutation database which would facilitate genetic counseling.
    Matched MeSH terms: Factor IX/analysis; Factor IX/genetics*
  4. Tiede A, Abdul-Karim F, Carcao M, Persson P, Clausen WHO, Kearney S, et al.
    Haemophilia, 2017 Jul;23(4):547-555.
    PMID: 28233381 DOI: 10.1111/hae.13191
    INTRODUCTION: Nonacog beta pegol (N9-GP) is a glycoPEGylated recombinant factor IX (FIX) with an extended half-life developed for routine prophylaxis and the prevention and treatment of bleeding episodes in patients with haemophilia B.

    AIM: The aim of this study was to evaluate the pharmacokinetics (PK) of N9-GP.

    METHODS: Data from 41 previously treated haemophilia B patients, enrolled globally (16 adolescents/adults and 25 children; FIX activity ≤0.02 IU mL-1) with no history of FIX inhibitors, were included. N9-GP was administered once-weekly as 10 IU kg-1or 40 IU kg-1in adolescents/adults and 40 IU kg-1in children. Blood was sampled up to 168 h (1 week) post dose. Standard PK was estimated on the basis of plasma FIX activity vs. time (PK profiles) using non-compartmental methods. Furthermore, a population PK analysis and FIX activity predictions were performed.

    RESULTS: Incremental recoveries were 0.02 (IU mL-1)/(IU kg-1) in both adolescents/adults and children. The extended half-life resulted in mean trough levels of 0.27 IU mL-1for adolescents/adults and 0.17 IU mL-1for children at steady-state after weekly dosing at 40 IU kg-1. The population PK analysis confirmed a mono-exponential decay in FIX activity and allowed for predictions of FIX activity for adolescents/adults above 0.15 IU mL-1at all times and 6.4 days week-1in children.

    CONCLUSION: N9-GP has the potential to shift previously treated haemophilia B patients from a severe/moderate disease state into a mild- or non-haemophilic range for most of the dosing interval, which is expected to reduce the number of bleeding episodes.

    Matched MeSH terms: Factor IX/pharmacokinetics*; Factor IX/therapeutic use
  5. Carcao M, Zak M, Abdul Karim F, Hanabusa H, Kearney S, Lu MY, et al.
    J Thromb Haemost, 2016 Aug;14(8):1521-9.
    PMID: 27174727 DOI: 10.1111/jth.13360
    Essentials Nonacog beta pegol is a recombinant glycoPEGylated factor IX with an extended half-life. This phase 3 trial investigated its safety/efficacy in previously treated hemophilia B boys ≤ 12 years. A 40 IU kg(-1) dose provided effective once-weekly prophylaxis and hemostasis when used to treat bleeds. Nonacog beta pegol was well tolerated in previously treated boys ≤ 12 years with hemophilia B.

    SUMMARY: Background Nonacog beta pegol is a recombinant glycoPEGylated factor IX with an extended half-life, developed to improve care for patients with hemophilia B. Objectives To investigate the safety, efficacy and pharmacokinetics of nonacog beta pegol for the prophylaxis and treatment of bleeds in previously treated children with hemophilia B. Patients/Methods This phase 3 trial, paradigm(™) 5, enrolled and treated 25 children (aged ≤ 12 years) with hemophilia B (FIX ≤ 2%). Patients were stratified by age (0-6 years and 7-12 years), and received once-weekly prophylaxis with 40 IU kg(-1) nonacog beta pegol for 50 exposure days. Results No patient developed inhibitors, and no safety concerns were identified. Forty-two bleeds in 15 patients were reported to have been treated; the overall success rate was 92.9%, and most bleeds (85.7%) resolved after one dose. The median annualized bleeding rates (ABRs; bleeds per patient per year) were 1.0 in the total population, 0.0 in the 0-6-year group, and 2.0 in the 7-12-year group; the estimated mean ABRs were 1.44 in the total population, 0.87 in the 0-6-year group, and 1.88 in the 7-12-year group. For 22 patients who had previously been receiving prophylaxis, the estimated mean ABR was 1.38 versus a historical ABR of 2.51. Estimated mean steady-state FIX trough levels were 0.153 IU mL(-1) (0-6 years) and 0.190 IU mL(-1) (7-12 years). Conclusion Nonacog beta pegol was well tolerated in previously treated children with hemophilia B; a 40 IU kg(-1) dose provided effective once-weekly prophylaxis and hemostasis when bleeds were treated.

    Matched MeSH terms: Factor IX/pharmacokinetics*; Factor IX/therapeutic use
  6. Négrier C, Abdul Karim F, Lepatan LM, Lienhart A, López-Fernández MF, Mahlangu J, et al.
    Haemophilia, 2016 Jul;22(4):e259-66.
    PMID: 27333467 DOI: 10.1111/hae.12972
    INTRODUCTION: Recombinant factor IX fusion protein (rIX-FP) has been developed to improve the pharmacokinetic (PK) profile of factor IX (FIX), allowing maintenance of desired FIX activity between injections at extended intervals, ultimately optimizing haemophilia B treatment.
    AIM: To determine the efficacy and safety of rIX-FP in the perioperative setting.
    METHODS: Subjects were adult and paediatric patients with severe to moderately severe haemophilia B (FIX ≤ 2%) participating in three Phase III clinical trials and undergoing a surgical procedure. PK profiles were established prior to surgery for each patient. Haemostatic efficacy was assessed by the investigator for up to 72 h after surgery. Safety measurements during the study included adverse events and inhibitors to FIX. FIX activity was monitored during and after surgery to determine if repeat dosing was required.
    RESULTS: Twenty-one, both major and minor, surgeries were performed in 19 patients. Haemostatic efficacy was rated as excellent (n = 17) or good (n = 4) in all surgeries. A single preoperative dose maintained intraoperative haemostasis in 20 of 21 surgeries. Nine major orthopaedic surgeries were conducted in eight patients with a mean of 7 (range: 6-12) rIX-FP injections during surgery and the 14-day postoperative period. Median rIX-FP consumption for orthopaedic surgeries was 87 IU kg(-1) preoperatively and 375 IU kg(-1) overall. No subject developed inhibitors to FIX or antibodies to rIX-FP.
    CONCLUSION: Recombinant factor IX fusion protein was well tolerated and effectively maintained haemostasis during and after surgery. Stable FIX activity was achieved with a prolonged dosing interval and reduced consumption compared to conventional or currently available long-acting recombinant FIX.
    KEYWORDS: albumin fusion proteins; factor IX; haemophilia B; orthopaedic surgery; recombinant fusion proteins
    Matched MeSH terms: Factor IX/genetics; Factor IX/metabolism; Factor IX/therapeutic use*
  7. Young G, Collins PW, Colberg T, Chuansumrit A, Hanabusa H, Lentz SR, et al.
    Thromb Res, 2016 May;141:69-76.
    PMID: 26970716 DOI: 10.1016/j.thromres.2016.02.030
    INTRODUCTION: Paradigm™4 was an international extension trial investigating the safety and efficacy of nonacog beta pegol, a recombinant glycoPEGylated factor IX (FIX) with extended half-life, in haemophilia B patients (FIX activity ≤2%; aged 13-70years) who had previously participated in phase III pivotal (paradigm™2) or surgery (paradigm™3) trials.

    METHODS: Patients chose to continue treatment with nonacog beta pegol in either one of two once-weekly prophylaxis arms (10IU/kg or 40IU/kg), or an on-demand arm (40IU/kg for mild/moderate bleeds; 80IU/kg for severe bleeds). The primary objective was to evaluate immunogenicity; key secondary objectives included assessing safety and haemostatic efficacy in the treatment and prevention of bleeds.

    RESULTS: Seventy-one patients received prophylaxis or on-demand treatment. No patient developed an inhibitor and no safety concerns were identified. The success rate for the treatment of reported bleeds was 94.6%; most (87.9%) resolved with one injection. The median annualised bleeding rate for patients on prophylaxis was 1.36 (interquartile range [IQR] 0.00-2.23) and 1.00 (IQR 0.00-2.03) for the 10 and 40IU/kg treatment arms, respectively. The mean FIX activity trough achieved for 10 and 40IU once weekly was 9.8% and 21.3%, respectively. Fourteen patients on prophylaxis underwent 23 minor surgical procedures; haemostatic perioperative outcomes for all of those evaluated were 'excellent' or 'good'.

    CONCLUSIONS: Nonacog beta pegol showed a favourable tolerability profile (with no safety issues identified) with good prophylactic protection and control of bleeding in previously treated adult and adolescent haemophilia B patients.

    Matched MeSH terms: Factor IX/administration & dosage; Factor IX/adverse effects; Factor IX/therapeutic use*
  8. Kavakli K, Smith L, Kuliczkowski K, Korth-Bradley J, You CW, Fuiman J, et al.
    Haemophilia, 2016 May;22(3):381-8.
    PMID: 26823276 DOI: 10.1111/hae.12878
    Limited data are available on optimal prophylaxis regimens of factor IX (FIX) replacements for patients with haemophilia B.
    Matched MeSH terms: Factor IX/genetics; Factor IX/metabolism; Factor IX/therapeutic use*
  9. Escobar MA, Tehranchi R, Karim FA, Caliskan U, Chowdary P, Colberg T, et al.
    Haemophilia, 2017 Jan;23(1):67-76.
    PMID: 27480487 DOI: 10.1111/hae.13041
    INTRODUCTION: Surgery in patients with haemophilia B carries a high risk of excessive bleeding and requires adequate haemostatic control until wound healing. Nonacog beta pegol, a long-acting recombinant glycoPEGylated factor IX (FIX), was used in the perioperative management of patients undergoing major surgery.
    AIM: To evaluate the efficacy and safety of nonacog beta pegol in patients with haemophilia B who undergo major surgery.
    METHODS: This was an open-label, multicentre, non-controlled surgery trial aimed at assessing peri- and postoperative efficacy and safety of nonacog beta pegol in 13 previously treated patients with haemophilia B. All patients received a preoperative nonacog beta pegol bolus injection of 80 IU kg-1 . Postoperatively, the patients received fixed nonacog beta pegol doses of 40 IU kg-1 , repeated at the investigator's discretion. Safety assessments included monitoring of immunogenicity and adverse events.
    RESULTS: Intraoperative haemostatic effect was rated 'excellent' or 'good' in all 13 cases. Apart from the preoperative injection, none of the patients needed additional doses of nonacog beta pegol on the day of surgery. The median number of postoperative doses of nonacog beta pegol was 2.0 from days 1 to 6 and 1.5 from days 7 to 13. No unexpected intra- or postoperative complications were observed including deaths or thromboembolic events. No patients developed inhibitors.
    CONCLUSIONS: These results indicated that nonacog beta pegol was safe and effective in the perioperative setting, allowing major surgical interventions in patients with haemophilia B with minimal peri- and postoperative concentrate consumption and infrequent injections as reported with standard FIX products.
    KEYWORDS: Phase III; factor IX; haemophilia B; long-acting recombinant factor IX; nonacog beta pegol; surgery
    Matched MeSH terms: Factor IX
  10. Khodarahimi S, Hashim IHM, Mohd-Zaharim N
    Psychol Belg, 2016 Mar 01;56(1):65-79.
    PMID: 30479429 DOI: 10.5334/pb.320
    The purpose of this research was to examine the validity of an adult attachment style questionnaire, to understand the relationships between the type of attachment style in relation to self-perceived stress and social support, and to investigate the influence of gender, ethnicity and religion on the above constructs. The participants were 308 university students from Malaysia. A demographic questionnaire and three self-report inventories were administrated in this study. The data indicated that the Relationship Scales Questionnaire (RSQ) is a multidimensional construct with nine factors: "dismissing," "preoccupied with romance," "preoccupied with close relationships," "fearful," "preoccupied with dependency," "secure emotional," "comfortable depending," "preoccupied with mistrust" and "mutual secure." Different attachment styles were positively or negatively correlated at a significant level with perceived stress and social support. Attachment styles were explained by 20 and 33% of the total variance in self-perceived stress and perceived social support, respectively. There were significant gender, ethnic and religious differences in attachment styles, perceived stress and social support.
    Matched MeSH terms: Factor IX
  11. Ong CC, Gopinath SCB, Rebecca LWX, Perumal V, Lakshmipriya T, Saheed MSM
    Int J Biol Macromol, 2018 Sep;116:765-773.
    PMID: 29775720 DOI: 10.1016/j.ijbiomac.2018.05.084
    There are different clotting factors present in blood, carries the clotting cascade and excessive bleeding may cause a deficiency in the clotting Diagnosis of this deficiency in clotting drastically reduces the potential fatality. For enabling a sensor to detect the clotting factors, suitable probes such as antibody and aptamer have been used to capture these targets on the sensing surface. Two major clotting factors were widely studied for the diagnosis of clotting deficiency, which includes factor IX and thrombin. In addition, factor IX is considered as the substitute for heparin and the prothrombotic associated with the increased thrombin generation are taking into account their prevalence. The biosensors, surface plasmon resonance, evanescent-field-coupled waveguide-mode sensor, metal-enhanced PicoGreen fluorescence and electrochemical aptasensor were well-documented and improvements have been made for high-performance sensing. We overviewed detecting factor IX and thrombin using these biosensors, for the potential application in medical diagnosis.
    Matched MeSH terms: Factor IX/metabolism*
  12. Liang T, Qu Q, Chang Y, Gopinath SCB, Liu XT
    Biotechnol Appl Biochem, 2019 Nov;66(6):939-944.
    PMID: 31468573 DOI: 10.1002/bab.1808
    Ovarian cancer starts in the ovaries in its earlier stages and then spreads to the pelvis, uterus, and abdominal region. The success of an ovarian cancer treatment depends on the stage of the cancer and the diagnostic system. Squamous cell carcinoma antigen (SCC-Ag) is one of the most efficient cancer biomarkers, and elevated levels of SCC-Ag in ovarian cancer cells have been used to identify ovarian cancer. Carbon is a potential material for biosensing applications due to its thermal, electrical, and physical properties. Multiwalled carbon nanotubes (MWCNTs) are carbon-based materials that can be used here to detect SCC-Ag. Anti-SCC-Ag antibody was immobilized on the amine-modified MWCNT dielectric sensing surface to detect SCC-Ag. The uniformity of the surface structure was measured with a 3D nanoprofiler, and the results confirmed the detection of SCC-Ag at ∼80 pM. The specific detection of SCC-Ag was confirmed with two control proteins (factor IX and human serum albumin), and the system did not show biofouling. This experimental set-up with MWCNTs a dielectric sensing surface can lead to the detection of ovarian cancer in its initial stages.
    Matched MeSH terms: Factor IX
  13. Gopinath SCB, Ismail ZH, Shapiai MI, Sobran NMM
    PMID: 33835514 DOI: 10.1002/bab.2164
    Artificial intelligence of things (AIoT) has become a potential tool for use in a wide range of fields, and its use is expanding in interdisciplinary sciences. On the other hand, in a clinical scenario, human blood-clotting disease (Royal disease) detection has been considered an urgent issue that has to be solved. This study uses AIoT with deep long short-term memory networks for biosensing application and analyzes the potent clinical target, human blood clotting factor IX, by its aptamer/antibody as the probe on the microscaled fingers and gaps of the interdigitated electrode. The earlier results by the current-volt measurements have shown the changes in the surface modification. The limit of detection (LOD) was noticed as 1 pM with the antibody as the probe, whereas the aptamer behaved better with the LOD at 100 fM. The time-series predictions from the AIoT application supported the obtained results with the laboratory analyses using both probes. This application clearly supports the results obtained from the interdigitated electrode sensor as aptamer to be the better option for analyzing the blood clotting defects. The current study supports a great implementation of AIoT in sensing application and can be followed for other clinical biomarkers.
    Matched MeSH terms: Factor IX
  14. Adam H, Gopinath SCB, Arshad MKM, Parmin NA, Hashim U
    Int J Biol Macromol, 2021 Feb 28;171:217-224.
    PMID: 33418041 DOI: 10.1016/j.ijbiomac.2021.01.014
    Misfolding and accumulation of the protein alpha synuclein in the brain cells characterize Parkinson's disease (PD). Electrochemical based aluminum interdigitated electrodes (ALIDEs) was fabricated by using conventional photolithography method and modified the surfaces with zinc oxide and gold nanorod by using spin coating method for the analysis of PD protein biomarker. The device surface modified with gold nanorod of 25 nm diameter was used. The bare devices and the surface modified devices were characterized by Scanning Electron Microscope, 3D-Profilometer, Atomic Force Microscope and high-power microscope. The above measurement was also performed to measure the interaction of antibody with aggregated alpha-synuclein for normal, aggregated and aggregated alpha synuclein in human serum and distinguished against 3 control proteins (PARK1, DJ-1 and Factor IX). The detection limit for normal alpha synuclein was 1 f. with the sensitivity of 1 f. on a linear regression (R2 = 0.9759). The detection limit for aggregated alpha synuclein was 10 aM with the sensitivity of 1 aM on a linear regression (R2 = 0.9797). Also, the detection limit of aggregated alpha synuclein in serum was 10 aM with the sensitivity of 1 aM on a linear regression (R2 = 0.9739). These results however indicate that, serum has only minimal amount of alpha synuclein.
    Matched MeSH terms: Factor IX
  15. Jameela, S., Rozika, P., Rizalman, J., Phan, C.L., Visalachy, P., Chang, K.M.
    Medicine & Health, 2011;6(2):126-130.
    MyJurnal
    The causes of an isolated prolonged activated partial thromboplastin time (APTT) with a normal prothrombin time (PT) are either a deficiency of clotting factors VIII, IX, XI or XII or the presence of an inhibitor. The inhibitor may be specific to an individual clotting factor or it may be a non-specific inhibitor like the lupus anticoagulant which has opposite therapeutic implications. We report a patient referred to our hospital for treatment that was previously diagnosed at another medical institution as an acquired factor IX inhibitor following an investigation for a prolonged APTT. On further testing this turned out to be a potent lupus anticoagulant which interfered with the phospholipid-dependent factor assays. The use of dilution studies, chromogenic assays and phospholipid neutralization can help differentiate these inhibitors. Great care must be taken in the interpretation of factor assays in the presence of lupus anticoagulant to avoid misdiagnosis and inappropriate treatment.
    Matched MeSH terms: Factor IX
  16. Zahari M, Sulaiman SA, Othman Z, Ayob Y, Karim FA, Jamal R
    Mediterr J Hematol Infect Dis, 2018;10(1):e2018056.
    PMID: 30210749 DOI: 10.4084/MJHID.2018.056
    Background: Haemophilia A (HA) and Haemophilia B (HB) are X-linked blood disorders that are caused by various mutations in the factor VIII (F8) and factor IX (F9) genes respectively. Identification of mutations is essential as some of the mutations are associated with the development of inhibitors. This study is the first comprehensive study of the F8 mutational profile in Malaysia.

    Materials and methods: We analysed 100 unrelated HA and 15 unrelated HB patients for genetic alterations in the F8 and F9 genes by using the long-range PCR, DNA sequencing, and the multiplex-ligation-dependent probe amplification assays. The prediction software was used to confirm the effects of these mutations on factor VIII and IX proteins.

    Results: 44 (53%) of the severe HA patients were positive for F8 intron 22 inversion, and three (3.6%) were positive for intron one inversion. There were 22 novel mutations in F8, including missense (8), frameshift (9), splice site (3), large deletion (1) and nonsense (1) mutations. In HB patients, four novel mutations were identified including the splice site (1), small deletion (1), large deletion (1) and missense (1) mutation.

    Discussion: The mutational spectrum of F8 in Malaysian patients is heterogeneous, with a slightly higher frequency of intron 22 inversion in these severe HA patients when compared to other Asian populations. Identification of these mutational profiles in F8 and F9 genes among Malaysian patients will provide a useful reference for the early detection and diagnosis of HA and HB in the Malaysian population.

    Matched MeSH terms: Factor IX
  17. Curtin J, Santagostino E, Karim FA, Li Y, Seifert W, Négrier C
    Thromb Res, 2020 04;188:85-89.
    PMID: 32109773 DOI: 10.1016/j.thromres.2020.02.011
    INTRODUCTION: Long-acting recombinant factor IX (FIX) products may simplify the surgical treatment of haemophilia B patients. The impact of rIX-FP, a recombinant FIX fused to recombinant albumin, on FIX consumption and surgical management was assessed in patients with haemophilia B.

    MATERIALS AND METHODS: Male patients, ≤65 years old with severe haemophilia B (FIX activity ≤2%) requiring non-emergency surgery were enrolled in the surgical substudy of PROLONG-9FP. Dosing was based on World Federation of Hemophilia guidelines and patients' pharmacokinetics. Haemostatic efficacy was assessed on a 4-point scale. rIX-FP consumption and safety were monitored throughout the perioperative period.

    RESULTS: This updated dataset reports on thirty (8 minor and 22 major) surgeries conducted in 21 patients. A single preoperative bolus was used in 96.7% (n = 29) of surgeries. After minor surgery, patients received a median (range) of 0 (0-3) infusions with a median (range) consumption of 0 (0-178.89) IU/kg in the 14-day postoperative period. In patients who underwent major surgery (including 15 patients undergoing joint replacement surgery), the median (range) number of infusions in the 14-day postoperative period was 5 (0-11) and median consumption was 221.7 (0-444.07) IU/kg. Haemostatic efficacy was rated as excellent or good in 87.5% (7/8) of minor surgeries and 95.5% (21/22) of major surgeries.

    CONCLUSION: Surgical procedures can be performed using a single preoperative bolus of rIX-FP in nearly all patients. During postoperative care, use of rIX-FP necessitated infrequent infusions and low FIX consumption. Overall, data suggest rIX-FP simplifies perioperative care in patients with haemophilia B.

    Matched MeSH terms: Factor IX
  18. Guo S, Lakshmipriya T, Gopinath SCB, Anbu P, Feng Y
    Nanoscale Res Lett, 2019 Jul 02;14(1):222.
    PMID: 31267309 DOI: 10.1186/s11671-019-3058-z
    Developing an enhanced diagnosis using biosensors is important for the treatment of patients before disease complications arise. Improving biosensors would enable the detection of various low-abundance disease biomarkers. Efficient immobilization of probes/receptors on the sensing surface is one of the efficient ways to enhance detection. Herein, we introduced the pre-alkaline sensing surface with amine functionalization for capturing gold nanoparticle (GNP) conjugated to human blood clotting factor IX (FIX), and we demonstrated the excellent performance of the strategy. We have chosen the enzyme-linked immunosorbent assay (ELISA) and the interdigitated electrode (IDE), which are widely used, to demonstrate our method. The optimal amount for silanization has been found to be 2.5%, and 15-nm-sized GNPs are ideal and characterized. The limit of FIX detection was attained with ELISA at 100 pM with the premixed GNPs and FIX, which shows 60-fold improvement in sensitivity without biofouling, as compared to the conventional ELISA. Further, FIX was detected with higher specificity in human serum at a 1:1280 dilution, which is equivalent to 120 pM FIX. These results were complemented by the analysis on IDE, where improved detection at 25 pM was achieved, and FIX was detected in human serum at the dilution of 1:640. These optimized surfaces are useful for improving the detection of different diseases on varied sensing surfaces.
    Matched MeSH terms: Factor IX
  19. Ishak R, Zakaria Z
    PMID: 9561621
    Hemophilia B is an X-linked recessive disorder of the hemostasis involving a defective clotting factor IX. Amplification of the regions containing restriction fragment length polymorphisms (RFLP) can be achieved by the use of polymerase chain reaction (PCR). This paper describes the analysis of 2 RFLPs involving the Dde1 and Taq1 restriction sites within the factor IX gene in a family with hemophilia B. Digestion of the PCR products with Taq1 revealed a 163bp fragment in all the family members. This finding suggests the absence of restriction site for Taq1 enzyme. However, the Dde1 digest results in bands 369bp and 319bp segregated amongst the family members. The pattern of inheritance of the 369bp fragment in this family suggested that both the patient's mother and aunt are not carriers and that the patient's factor IX gene could have undergone a de novo mutation producing a defective factor IX gene responsible for the hemophilia B. This is supported by the fact that no family history of hemophilia B is indicated in the other male members within the family.
    Matched MeSH terms: Factor IX/genetics*
  20. Collins PW, Young G, Knobe K, Karim FA, Angchaisuksiri P, Banner C, et al.
    Blood, 2014 Dec 18;124(26):3880-6.
    PMID: 25261199 DOI: 10.1182/blood-2014-05-573055
    This multinational, randomized, single-blind trial investigated the safety and efficacy of nonacog beta pegol, a recombinant glycoPEGylated factor IX (FIX) with extended half-life, in 74 previously treated patients with hemophilia B (FIX activity ≤2 IU/dL). Patients received prophylaxis for 52 weeks, randomized to either 10 IU/kg or 40 IU/kg once weekly or to on-demand treatment of 28 weeks. No patients developed inhibitors, and no safety concerns were identified. Three hundred forty-five bleeding episodes were treated, with an estimated success rate of 92.2%. The median annualized bleeding rates (ABRs) were 1.04 in the 40 IU/kg prophylaxis group, 2.93 in the 10 IU/kg prophylaxis group, and 15.58 in the on-demand treatment group. In the 40 IU/kg group, 10 (66.7%) of 15 patients experienced no bleeding episodes into target joints compared with 1 (7.7%) of 13 patients in the 10 IU/kg group. Health-related quality of life (HR-QoL) assessed with the EuroQoL-5 Dimensions visual analog scale score improved from a median of 75 to 90 in the 40 IU/kg prophylaxis group. Nonacog beta pegol was well tolerated and efficacious for the treatment of bleeding episodes and was associated with low ABRs in patients receiving prophylaxis. Once-weekly prophylaxis with 40 IU/kg resolved target joint bleeds in 66.7% of the affected patients and improved HR-QoL. This trial was registered at www.clinicaltrials.gov as #NCT01333111.
    Matched MeSH terms: Factor IX/administration & dosage*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links