Displaying all 6 publications

Abstract:
Sort:
  1. Semail NF, Keyon ASA, Saad B, Kamaruzaman S, Zain NNM, Lim V, et al.
    J Chromatogr A, 2022 Dec 06;1685:463616.
    PMID: 36335907 DOI: 10.1016/j.chroma.2022.463616
    Realising the need to devise a simple, sensitive, and reliable detection method, this study investigated the development of a dual-stacking transient isotachophoresis (t-ITP) and sweeping in micellar electrokinetic chromatography with diode array detector (t-ITP/sweeping-MEKC-DAD) for the determination of selected non-steroidal anti-inflammatory drugs (NSAIDs); ketoprofen, diclofenac and naproxen from aqueous matrices. Prior to the system setup, various parameters were optimised to assess the potential use of the t-ITP paired with the sweeping stacking technique in micellar background electrolyte for dual preconcentration and separation of trace amounts of NSAIDs. Once the optimum conditions have been established, the method performance was validated and applied to 17 environmental water samples. Based on the results, the combined t-ITP and sweeping approach significantly improved the stacking and separation sensitivity. A large volume of samples could also be introduced and subsequently separated by MEKC with greater focusing effects due to the sweeping. Under optimised conditions, the developed method exhibited excellent linearity at a high range (0.1-500 ng/mL, r2 ≥ 0.998), low limits of detection (LODs) of 0.01-0.07 ng/mL, and a remarkable relative recovery (RR) of 99.6-101.9% with a relative standard deviation (RSD) of 1.4-8.6% (n = 9). Ultimately, the sensitivity enhancement factors improved up to 666-fold using the optimised method. Therefore, the proposed method presents a simplified yet effective and suitable for the determination of NSAIDs from aqueous matrices.
    Matched MeSH terms: Isotachophoresis*
  2. John AS, Sidek MM, Thang LY, Sami S, Tey HY, See HH
    J Chromatogr A, 2021 Feb 08;1638:461868.
    PMID: 33453653 DOI: 10.1016/j.chroma.2020.461868
    One of the major drawbacks of electrophoresis in both capillary and microchip is the unsatisfactory sensitivity. Online sample preconcentration techniques can be regarded as the most common and powerful approaches commonly applied to enhance overall detection sensitivity. While the advances of various online preconcentration strategies in capillary and microchip employing aqueous background electrolytes are well-reviewed, there has been limited discussion of the feasible preconcentration techniques specifically developed for capillary and microchip using nonaqueous background electrolytes. This review provides the first consolidated overview of various online preconcentration techniques in nonaqueous capillary and microchip electrophoresis, covering the period of the last two decades. It covers developments in the field of sample stacking, isotachophoresis, and micellar-based stacking. Attention is also given to multi-stacking strategies that have been used for nonaqueous electrophoresis.
    Matched MeSH terms: Isotachophoresis
  3. Abdul Keyon AS, Guijt RM, Bolch CJ, Breadmore MC
    J Chromatogr A, 2014 Oct 17;1364:295-302.
    PMID: 25223612 DOI: 10.1016/j.chroma.2014.08.074
    The accumulation of paralytic shellfish toxins (PSTs) in contaminated shellfish is a serious health risk making early detection important to improve shellfish safety and biotoxin management. Capillary electrophoresis (CE) has been proven as a high resolution separation technique compatible with miniaturization, making it an attractive choice in the development of portable instrumentation for early, on-site detection of PSTs. In this work, capillary zone electrophoresis (CZE) with capacitively coupled contactless conductivity detector (C(4)D) and UV detection were examined with counter-flow transient isotachophoresis (tITP) to improve the sensitivity and deal with the high conductivity sample matrix. The high sodium concentration in the sample was used as the leading ion while l-alanine was used as the terminating electrolyte (TE) and background electrolyte (BGE) in which the toxins were separated. Careful optimization of the injected sample volume and duration of the counter-flow resulted in limit of detections (LODs) ranging from 74.2 to 1020 ng/mL for tITP-CZE-C(4)D and 141 to 461 ng/mL for tITP-CZE-UV, an 8-97 fold reduction compared to conventional CZE. The LODs were adequate for the analysis of PSTs in shellfish samples close to the regulatory limit. Intra-day and inter-day repeatability values (percentage relative standard deviation, n=3) of tITP-CZE-C(4)D and tITP-CZE-UV methods for both migration time and peak height were in the range of 0.82-11% and 0.76-10%, respectively. The developed method was applied to the analysis of a contaminated mussel sample and validated against an Association of Official Analytical Chemists (AOAC)-approved method for PSTs analysis by high performance liquid chromatography (HPLC) with fluorescence detection (FLD) after pre-column oxidation of the sample. The method presented has potential for incorporation in to field-deployable devices for the early detection of PSTs on-site.
    Matched MeSH terms: Isotachophoresis/methods
  4. Breadmore MC, Wuethrich A, Li F, Phung SC, Kalsoom U, Cabot JM, et al.
    Electrophoresis, 2017 01;38(1):33-59.
    PMID: 27678139 DOI: 10.1002/elps.201600331
    One of the most cited limitations of capillary (and microchip) electrophoresis is the poor sensitivity. This review continues to update this series of biennial reviews, first published in Electrophoresis in 2007, on developments in the field of on-line/in-line concentration methods in capillaries and microchips, covering the period July 2014-June 2016. It includes developments in the field of stacking, covering all methods from field amplified sample stacking and large volume sample stacking, through to isotachophoresis, dynamic pH junction, and sweeping. Attention is also given to on-line or in-line extraction methods that have been used for electrophoresis.
    Matched MeSH terms: Isotachophoresis/methods*
  5. Thang LY, See HH, Quirino JP
    Talanta, 2016 Dec 01;161:165-169.
    PMID: 27769394 DOI: 10.1016/j.talanta.2016.08.054
    The low conductivity of separation electrolytes employed in nonaqueous capillary electrophoresis (NACE) limits the use of on-line sample concentration or stacking by field enhancement. Herein, micelle-to-solvent stacking (MSS) was performed by the simple injection of a micellar solution plug prior to electrokinetic injection of sample prepared under field-enhanced stacking conditions (known as field-enhanced sample injection, FESI). The proposed approach allowed a 214-625-fold improvement in peak signals for targeted anticancer drugs (e.g., tamoxifen) and its major metabolites in NACE using 100% methanol-based separation electrolyte that comprised of 7.5mM deoxycholic acid sodium salt, 15mM acetic acid and 1mM 18-crown-6. These improvements yielded tamoxifen and its metabolites with 2-5 times better stacking efficiency as compared to those obtained without micellar solution injection or FESI only. This is comparable to the results typically achieved when FESI is combined with isotachophoresis (electrokinetic supercharging). The FESI-MSS-NACE was tested for the measuring levels of target drugs in plasma. The analytical figures of merit are also reported.
    Matched MeSH terms: Isotachophoresis
  6. Breadmore MC, Grochocki W, Kalsoom U, Alves MN, Phung SC, Rokh MT, et al.
    Electrophoresis, 2019 01;40(1):17-39.
    PMID: 30362581 DOI: 10.1002/elps.201800384
    One of the most cited limitations of capillary and microchip electrophoresis is the poor sensitivity. This review continues to update this series of biannual reviews, first published in Electrophoresis in 2007, on developments in the field of online/in-line concentration methods in capillaries and microchips, covering the period July 2016-June 2018. It includes developments in the field of stacking, covering all methods from field-amplified sample stacking and large-volume sample stacking, through to isotachophoresis, dynamic pH junction, and sweeping. Attention is also given to online or in-line extraction methods that have been used for electrophoresis.
    Matched MeSH terms: Isotachophoresis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links