Displaying all 10 publications

Abstract:
Sort:
  1. Kamsiah GH, Ramli Y, Idris AY
    Quintessence Int, 1993 May;24(5):311-2.
    PMID: 8362043
    A technique in which the custom-made anterior ceramometal pontics are securely attached to the metal framework of a Kennedy Class IV removable partial denture is described. This technique results in a more esthetic prosthesis with less palatal coverage.
    Matched MeSH terms: Metal Ceramic Alloys*
  2. Soo SY, Silikas N, Satterthwaite J
    Materials (Basel), 2019 Jun 23;12(12).
    PMID: 31234580 DOI: 10.3390/ma12122009
    A single paragraph of about 200 words maximum. For research articles, abstracts should give a pertinent overview of the work. We strongly encourage authors to use the following style of structured abstracts, but without headings: (1) Background: Place the question addressed in a broad context and highlight the purpose of the study; (2) Methods: Describe briefly the main methods or treatments applied; (3) Results: Summarize the article's main findings; and (4) Conclusions: Indicate the main conclusions or interpretations. The abstract should be an objective representation of the article, it must not contain results which are not presented and substantiated in the main text and should not exaggerate the main conclusions. Please add in this section. The aim of the study was to investigate the fracture behaviour of four different groups of zirconia abutments with internal and external connections: (A) Astra Tech ZirDesign™ abutment on Astra Tech Implants, (B) Procera® Esthetic abutment on Nobel Biocare MK III Groovy Implants, (C) IPS e.max® on Straumann Implants, and (D) ZiReal® Posts on Biomet 3I implants. The load was applied on the assemblies using a Zwick universal testing machine: the initial and final failure loads and amplitude were recorded using acoustic emission technique. Mean initial and final failure force was found to be significantly different in each group (P < 0.001). IPS e.max® Straumann abutments exhibited the highest resistance to final fracture force compared to other abutment types. Acoustic emission can be used as one of the methods to detect fracture behaviour of implant abutments. There were no significant differences in fracture loads between the internal and externally connected zirconia abutments studied. However, externally connected abutments demonstrated screw loosening and some deformations.
    Matched MeSH terms: Metal Ceramic Alloys
  3. Goo CL, Tan KB
    Case Rep Dent, 2017;2017:9373818.
    PMID: 28396807 DOI: 10.1155/2017/9373818
    This report describes the clinical and technical aspects in the oral rehabilitation of an edentulous patient with knife-edge ridge at the mandibular anterior edentulous region, using implant-retained overdentures. The application of computer-aided design and computer-aided manufacturing (CAD/CAM) in the fabrication of the overdenture framework simplifies the laboratory process of the implant prostheses. The Nobel Procera CAD/CAM System was utilised to produce a lightweight titanium overdenture bar with locator attachments. It is proposed that the digital workflow of CAD/CAM milled implant overdenture bar allows us to avoid numerous technical steps and possibility of casting errors involved in the conventional casting of such bars.
    Matched MeSH terms: Metal Ceramic Alloys
  4. Al-Marzok MI, Al-Azzawi HJ
    J Contemp Dent Pract, 2009;10(6):E017-24.
    PMID: 20020077
    Dental plaque has a harmful influence on periodontal tissue. When a porcelain restoration is fabricated and refinishing of the glazed surface is inevitable, the increase in surface roughness facilitates the adhesion of plaque and its components. The aim of this in vitro study was to evaluate the effect of surface roughness of glazed or polished porcelain on the adhesion of oral Streptococcus mutans.
    Matched MeSH terms: Metal Ceramic Alloys*
  5. Lui JL
    Dent Traumatol, 2001 Oct;17(5):227-30.
    PMID: 11678543
    The composite reinforcement technique has been used clinically to salvage damaged root-filled teeth compromised by caries, trauma, developmental abnormalities, internal resorption and iatrogenic causes. This clinical case report describes the use of the technique to reattach a fractured fragment in a compromised endodontically treated root besides reinforcing it for continued function in the mouth. Factors of clinical importance related to this additional application; including reattachment of tooth fragments, post crown retention, coronal microleakage and fracture resistance and strength, are also briefly discussed.
    Matched MeSH terms: Metal Ceramic Alloys/chemistry
  6. Patil PG, Nimbalkar-Patil SP, Karandikar AB
    J Contemp Dent Pract, 2014 Jan 1;15(1):112-5.
    PMID: 24939276
    This case report demonstrates sequential periodontic, orthodontic and prosthodontic treatment modalities to save and restore deep horizontally fractured maxillary central incisor. The location of fracture was deep in the mucosa which reveals less than 2 mm of tooth structure to receive the crown. The procedures like surgical crown lengthening, endodontic post placement, orthodontic forced eruption, core build-up and metal-ceramic crown restoration were sequentially performed to conserve the fractured tooth. Forced eruption is preferred to surgical removal of supporting alveolar bone, since forced eruption preserves the biologic width, maintains esthetics, and at the same time exposes sound tooth structure for the placement of restorative margins.
    Matched MeSH terms: Metal Ceramic Alloys/chemistry
  7. Al-Maqtari AA, Lui JL
    J Prosthodont, 2010 Jul;19(5):347-56.
    PMID: 20456026 DOI: 10.1111/j.1532-849X.2010.00593.x
    The purpose of this in vitro study was to determine if packable resin composite with/without flowable resin composite has the ability to prevent coronal leakage in restored endodontic access openings following aging.
    Matched MeSH terms: Metal Ceramic Alloys/chemistry*
  8. Baig MR, Rajan G, Rajan M
    J Oral Implantol, 2009;35(6):295-9.
    PMID: 20017646 DOI: 10.1563/AAID-JOI-D-09-00012R1.1
    This article describes the rehabilitation of a completely edentulous patient using a milled titanium implant framework and cemented crowns. This combined approach significantly offsets unsuitable implant position, alignment, or angulation, while ensuring the easy retrievability, repair, and maintenance of the prosthesis. Hence, the dual advantage of cemented-retained crowns reproducing appropriate esthetics and function, irrespective of where the screw access openings are located in the substructure, can be obtained, along with the splinting effect and management of soft and hard tissue deficits achievable with a screw-retained framework.
    Matched MeSH terms: Metal Ceramic Alloys/chemistry
  9. Baig MR, Gunaseelan R
    J Oral Implantol, 2012 Apr;38(2):149-53.
    PMID: 20932151 DOI: 10.1563/AAID-JOI-D-09-00089
    Passive fit of a long-span screw-retained implant prosthesis is an important criteria for the success of the restoration. This article describes a technique for fabricating a ceramometal implant fixed dental prosthesis (FDP) for a long-span partially edentulous situation by altering the conventional screw-retained design. The possibility of a passive fit is maximized by intraoral luting of the cast frame to milled abutments, and the potential framework distortion during fabrication is compensated to a major extent. Retrievability is ensured by screw retention of the prosthesis to the implants. Compared with conventional porcelain fused to metal screw-retained FDP, this prosthesis is relatively inexpensive to fabricate.
    Matched MeSH terms: Metal Ceramic Alloys/chemistry*
  10. Seow LL, Toh CG, Wilson NH
    Eur J Prosthodont Restor Dent, 2005 Jun;13(2):57-64.
    PMID: 16011232
    Existing literature suggests a relationship between the amount of remaining tooth structure and the fracture resistance of the restored endodontically treated tooth. This study investigated the amount of tooth structure remaining following various tooth preparations used in the restoration of the endodontically treated maxillary second premolar. Illustrations of the maxillary second premolar in buccopalatal, mesiodistal and occlusal sections were drawn to scale. Outlines of various intra- and extracoronal preparations were superim-posed on the illustrations to reveal the amount of tooth tissue remaining in each case. Preparations for a ceramic inlay, inlay with palatal cusp coverage and onlay left 2.0-2.5mm of tooth structure buccally and palatally. Following preparation for a metal-ceramic crown, approximately 1.0mm of tooth structure remained buccally, and between 1.6mm-1.8mm palatally. Preparation for an all-ceramic crown was observed to leave 1.0mm-1.2mm of tooth structure surrounding what remained of the endodontic access cavity. It was concluded that decisions as to the type of definitive restoration to restore the endodontically treated maxillary second premolar may be influenced, amongst other factors, by information on the amount of tooth tissue remaining following preparation.
    Matched MeSH terms: Metal Ceramic Alloys
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links