Affiliations 

  • 1 Applied Physics and Radiation Technologies Group, CCDCU, School of Engineering and Technology, Sunway University, 47500, Bandar Sunway, Selangor, Malaysia
  • 2 Applied Physics and Radiation Technologies Group, CCDCU, School of Engineering and Technology, Sunway University, 47500, Bandar Sunway, Selangor, Malaysia; Faculty of Graduate Studies, Daffodil International University, Daffodil Smart City, Birulia, Savar, Dhaka, 1216, Bangladesh. Electronic address: mu_khandaker@yahoo.com
  • 3 Department of Physics, Faculty of Science, University of Malaya, 50603, Kuala Lumpur, Malaysia
  • 4 Clinical Oncology Unit, Faculty of Medicine, University of Malaya, 50603, Kuala Lumpur, Malaysia
  • 5 Department of Radiological Sciences, College of Applied Medical Sciences, Taif University, 21944, Taif, Saudi Arabia
  • 6 Nuclear Materials Authority, P.O. Box 530 El-Maadi, Cairo, Egypt; Ural Federal University, St. Mira, 19, 620002, Yekaterinburg, Russia
  • 7 Department of Physics, Faculty of Science, Isra University, Amman, Jordan; Department of Physics and Technical Sciences, Western Caspian University, Baku, Azerbaijan
  • 8 Department of Radiological Sciences, College of Applied Medical Sciences, King Saud University, PO Box 10219, Riyadh, 11433, Saudi Arabia
  • 9 Department of Basic Sciences, Deanship of Preparatory Year and Supporting Studies, Imam Abdulrahman Bin Faisal University, Dammam, 34212, Saudi Arabia
  • 10 Applied Physics and Radiation Technologies Group, CCDCU, School of Engineering and Technology, Sunway University, 47500, Bandar Sunway, Selangor, Malaysia; School of Mathematics and Physics, University of Surrey, Guildford, GU2 7XH, United Kingdom
Appl Radiat Isot, 2024 Oct;212:111457.
PMID: 39068692 DOI: 10.1016/j.apradiso.2024.111457

Abstract

In clinical settings, standard dosimeters might miss radiation mishaps. Retrospective dosimeters could help to track personnel (such as patients and other staff who don't wear dosimeters) exceeding safe limits and assess long-term exposure trends. This study has investigated key thermoluminescence (TL) dosimetric characteristics, including the glow curve structure, dose-response, energy dependence, sensitivity and fading of various safety glasses that are used as screen protectors of smartphones subjected to photon irradiation. Among the studied glasses, the HD Anti-Peep safety glass for iPhone has been found to exhibit a linear dose-response with a regression coefficient of 99% within the dose range of 2-10 Gy. Moreover, all the safety glasses showed independence with respect to photon energy of 6 MV and 10 MV. The TL glow curves of the samples showed a broad glow peak between 125 °C and 325 °C at 10 Gy. The TL kinetic parameters of the safety glasses were also studied by analyzing the glow curves using the peak shape and initial rise method. The geometric factor (μg) is found to be within the range of 0.43-0.53, which indicates the suitability of applying Chen's general-order formula to calculate the kinetic parameters such as activation energy, frequency factor and trap lifetime. The activation energy (E) and frequency factor (s) are found in the range of 0.31-0.54 eV and 4.55 × 103 to 2.12 × 106 s-1 respectively obtained via the peak shape method. The relatively long trap lifetime and observed thermoluminescence features indicate that the HD Anti-Peep safety glass offers a better option to estimate dose retrospectively to ensure the safety of human health.