Affiliations 

  • 1 Universiti Putra Malaysia, Faculty of Medicine and Health Sciences, Departments of Pathology, Selangor, Malaysia
  • 2 Universiti Putra Malaysia, Faculty of Medicine and Health Sciences, Departments of Pathology, Selangor, Malaysia. subashini@upm.edu.my
Malays J Pathol, 2021 Apr;43(1):101-107.
PMID: 33903313

Abstract

INTRODUCTION: Haemolytic specimens are a frequent occurrence in clinical laboratories, and they interfere with the analysis of many tests.

CASE REPORT: We describe here an unusual case of leptospirosis complicated by haemolytic anaemia in a 70-year-old man with established kidney failure. He presented with an abrupt onset of shortness of breath, flushing and erythematous rash after completing haemodialysis. The patient's biochemistry test samples were however rejected twice as they were grossly haemolysed. The integrated auto-verification alert system implemented in the hospital's laboratory information system alerted the staff of the possibility of in vivo haemolysis.

DISCUSSION: The auto-verification alert system effectively distinguishes between in vitro and in vivo haemolysis and as such can be utilised as a diagnostic aid in patients with suspected intravascular haemolysis.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.