Introduction: This study reported the concentration of bacterial and fungal bioaerosol at an animal house and hospi- tal laboratories with the aim to compare the concentration levels at library and administrative offices. The bioaerosol levels between mid-shift (afternoon) were also compared to the concentration measured during pre-shift (morning). Methods: The NIOSH 0800 method utilising microbiological air sampler collecting airborne bacterial and fungal samples via impaction technique on Nutrient agar (NA) and Sabouraud Dextrouse agar (SDA) as culture medium, respectively. Sampling was done twice daily; before (pre-shift) and during working (mid-shift) hour. Results: The highest bacteria and fungi concentration was recorded at the animal house with median concentration of 2477 CFU/ m3 (IQR=121-2477) and 791 CFU/m3 (IQR = 379-2081), respectively. Higher-risked workplaces such as animal house and hospital laboratories have significantly higher bioaerosol concentrations compared to control workplaces such as library and administrative offices (p