Displaying publications 1 - 20 of 27 in total

Abstract:
Sort:
  1. Abdullah A, Mahmud MR, Maimunah A, Zulfiqar MA, Saim L, Mazlan R
    Ann Acad Med Singap, 2003 Jul;32(4):442-5.
    PMID: 12968546
    INTRODUCTION: Accurate preoperative imaging of the temporal bone in patients receiving cochlear implants is important. High resolution computed tomography (HRCT) and magnetic resonance (MR) imaging are the 2 preoperative imaging modalities that provide critical information on abnormalities of the otic capsule, pneumatisation of the mastoid, middle ear abnormalities, cochlear ducts patency and presence of cochlear nerve.

    MATERIALS AND METHODS: The HRCT and MR imaging in 46 cochlear implant patients in our department were reviewed.

    RESULTS: Majority of our patients [34 patients (73.9%)] showed normal HRCT of the temporal bone; 5 (10.9%) patients had labyrinthitis ossificans, 2 (4.3%) had Mondini's abnormality and 2 (4.3%) had middle ear effusion. One patient each had high jugular bulb, hypoplasia of the internal auditory canal and single cochlear cavity, respectively.

    CONCLUSION: The above findings contribute significantly to our surgical decisions regarding candidacy for surgery, side selection and surgical technique in cochlear implantation.

  2. Rozman Z, Thambidorai RR, Zaleha AM, Zakaria Z, Zulfiqar MA
    Biomed Imaging Interv J, 2011 Jul-Sep;7(3):e18.
    PMID: 22279495 MyJurnal DOI: 10.2349/biij.7.3.e18
    This study aims to evaluate the effectiveness of intralesional bleomycin sclerotherapy in the treatment of lymphangioma in children and to determine the incidence of complications in the treatment.
  3. Zulfiqar M, Rohazly I, Rahmah M
    Biomed Imaging Interv J, 2011 Apr;7(2):e14.
    PMID: 22291859 MyJurnal DOI: 10.2349/biij.7.2.e14
    PURPOSE: TO DETERMINE: (i) the mammographic parenchymal patterns in Malaysian women and whether the breasts are dense on mammogram; (ii) the effect of age on breast density; (iii) the effect of parity on breast density; (iv) the difference in breast parenchymal patterns among the major races of women in Malaysia.
    METHODS: This was a descriptive cross-sectional study of 1,784 patients (981 Malays, 571 Chinese, 214 Indians and 18 others) who had undergone mammography during the 1-year study period. Majority of women (41.7%) were aged between 51 and 60 years and majority (43%) had 3-4 children. The Tabar classification (Pattern I - V) was used to evaluate breast parenchymal patterns on mammogram. Tabar Pattern I was further divided into 3 sub-groups (Pattern IA, IB, and IC). The different patterns were then grouped into dense (IB, IC, IV, V) and not dense (IA, II, III) breasts. The SPSS package was used for statistical analysis.
    RESULTS: Majority (59%) of Malaysian women had dense breasts (Pattern IB 29%, IC 20%, IV 5%, and V 5%) and 41% did not have dense breasts (Pattern IA 28%, II 6%, and III 7%). Age and parity were inversely related to breast density (p < 0.0001). Chinese women (65.7%) had the highest percentage of dense breasts (p = 0.69, odds ratio = 1.22), followed by the Indians (57.2%) and the Malays (50.5%).
    CONCLUSION: Majority of women had dense breasts but Pattern IV, which has been associated with increased risk of breast cancer, was seen in only 5% of the women. The breast density reduced steadily with increasing age and parity. There was no statistically significant difference in breast density in the three main races.
    KEYWORDS: Mammography; breast density; breast parenchymal patterns
  4. Faizah M, Kanaheswari Y, Thambidorai C, Zulfiqar M
    Biomed Imaging Interv J, 2011 Jan-Mar;7(1):e7.
    PMID: 21655116 MyJurnal DOI: 10.2349/biij.7.1.e7
    To compare echocontrast cystosonography (ECS) using in-vivo agitated saline with fluoroscopic micturating cystourethrography (MCU) in the detection and grading of vesicoureteric reflux (VUR).
  5. Faizah M, Zuhanis A, Rahmah R, Raja A, Wu L, Dayang A, et al.
    Biomed Imaging Interv J, 2012 Jan;8(1):e6.
    PMID: 22970062 MyJurnal DOI: 10.2349/biij.8.1.e6
    This review was aimed at determining the imaging findings in patients with precocious puberty.
  6. Yunus U, Zulfiqar MA, Ajmal M, Bhatti MH, Chaudhry GE, Muhammad TST, et al.
    Biomed Mater, 2020 09 26;15(6):065004.
    PMID: 32442994 DOI: 10.1088/1748-605X/ab95e1
    Gemcitabine (GEM) is used to treat various cancers such as breast, pancreatic, non-small lung, ovarian, bladder, and cervical cancers. GEM, however, has the problem of non-selectivity. Water-soluble, fluorescent, and mono-dispersed carbon dots (CDs) were fabricated by ultrasonication of sucrose. The CDs were further conjugated with GEM through amide linkage. The physical and morphological properties of these carbon dot-gemcitabine (CD-GEM) conjugates were determined using different analytical techniques. In vitro cytotoxicity and apoptosis studies of CD-GEM conjugates were evaluated by various bioactivity assays on human cell lines, MCF-7 (human breast adenocarcinoma), and HeLa (cervical cancer) cell lines. The results of kinetic studies have shown a maximum drug loading efficacy of 17.0 mg of GEM per 50.0 mg of CDs. The CDs were found biocompatible, and the CD-GEM conjugates exhibited excellent bioactivity and exerted potent cytotoxicity against tumor cells with an IC50 value of 19.50 μg ml-1 in HeLa cells, which is lower than the IC50 value of pure GEM (∼20.10 μg ml-1). In vitro studies on CD-GEM conjugates demonstrated the potential to replace the conventional administration of GEM. CD-GEM conjugates are more stable, have a higher aqueous solubility, and are more cytotoxic as compared to GEM alone. The CD-GEM conjugates show reduced side effects in the normal cells along with excellent cellular uptake. Hence, CD-GEM conjugates are more selective toward cancerous cell lines as compared to non-cancerous cells. Also, the CD-GEM conjugates successfully induced early and late apoptosis in cancer cell lines and might be effective and safe to use for in vivo applications.
  7. Sakina MS, Goh BS, Abdullah A, Zulfiqar MA, Saim L
    Int J Pediatr Otorhinolaryngol, 2006 Dec;70(12):2093-7.
    PMID: 16996619
    Sensorineural hearing loss (SNHL) due to internal auditory canal (IAC) stenosis with hypoplasia of the cochleovestibular nerve is a rare disorder. The diagnosis of the IAC stenosis requires both high resolution computed tomography scan (HRCT) and magnetic resonance imaging (MRI).
  8. Kanaheswari Y, Lai C, Raja Lope RJ, Azizi AB, Zulfiqar MA
    J Paediatr Child Health, 2015 Feb;51(2):223-5.
    PMID: 25099316 DOI: 10.1111/jpc.12707
    Congenital dermal sinus (CDS) and occult spinal dysraphism are suspected when a cutaneous marker overlies the spine of a newborn. CDS can have the appearance of a simple dimple and occur within the gluteal cleft without any skin markers. CDS are the commonest cause of intramedullary spinal cord abscess.
  9. Boo NY, Chandran V, Zulfiqar MA, Zamratol SM, Nyein MK, Haliza MS, et al.
    J Paediatr Child Health, 2000 Aug;36(4):363-9.
    PMID: 10940172
    OBJECTIVES: To identify the types of early cranial ultrasound changes that were significant predictors of adverse outcome during the first year of life in asphyxiated term infants.

    METHODOLOGY: This was a prospective cohort study. Shortly after birth, cranial ultrasonography was carried out via the anterior fontanelles of 70 normal control infants and 104 asphyxiated infants with a history of fetal distress and Apgar scores of less than 6 at 1 and 5 min of life, or requiring endotracheal intubation and manual intermittent positive pressure ventilation for at least 5 min after birth. Neurodevelopmental assessment was carried out on the survivors at 1 year of age.

    RESULTS: Abnormal cranial ultrasound changes were detected in a significantly higher proportion (79.8%, or n = 83) of asphyxiated infants than controls (39.5%, or n = 30) (P < 0.0001). However, logistic regression analysis showed that only three factors were significantly associated with adverse outcome at 1 year of life among the asphyxiated infants. These were: (i) decreasing birthweight (for every additional gram of increase in birthweight, adjusted odds ratio (OR) = 0.999, 95% confidence interval (CI) 0.998, 1.000; P = 0.047); (ii) a history of receiving ventilatory support during the neonatal period (adjusted OR = 8.3; 95%CI 2.4, 28.9; P = 0.0009); and (iii) hypoxic-ischaemic encephalopathy stage 2 or 3 (adjusted OR = 5.8; 95%CI 1.8, 18.6; P = 0.003). None of the early cranial ultrasound changes was a significant predictor.

    CONCLUSIONS: Early cranial ultrasound findings, although common in asphyxiated infants, were not significant predictors of adverse outcome during the first year of life in asphyxiated term infants.

  10. Boo NY, Cheong KB, Cheong SK, Lye MS, Zulfiqar MA
    J Paediatr Child Health, 1997 Aug;33(4):329-34.
    PMID: 9323622
    OBJECTIVES: To compare the overall accuracy of the stable microbubble test (SM test) with measurement of level of surfactant protein A (SP-A) of tracheal aspirate for the diagnosis of respiratory distress syndrome (RDS).

    METHODOLOGY: Tracheal aspirates were obtained from neonates on ventilatory support. The SM test was carried out on specimens of tracheal aspirate immediately after collection. Levels of SP-A in tracheal aspirates were determined by enzyme-linked immunosorbent assay (ELISA) method. The results of the SM test and SP-A level of the tracheal aspirates were compared against the clinical diagnosis of RDS based on clinical, radiological and bacteriological findings.

    RESULTS: Both the median microbubble counts (6 microbubbles/mm2, range = 0-90) and median SP-A levels (100 micrograms/L, range = 0-67447) of infants with RDS were significantly lower than those of infants with no obvious lung pathology (P < 0.0001), and pneumonia (P < 0.0001). The SM test of tracheal aspirates had higher overall accuracy for the diagnosis of RDS than measurement of SP-A levels (94.6% vs 82.4%). When the receiver operating characteristic (ROC) curves of both tests for RDS were compared, the area under the ROC curve of the SM test was larger (0.9689) than that of the SP-A method (0.8965).

    CONCLUSIONS: This study showed that the SM test of tracheal aspirate was a useful bedside diagnostic test for RDS. It could be carried out at any time after birth on infants requiring ventilatory support.

  11. Boo NY, Zuraidah AL, Lim NL, Zulfiqar MA
    J Trop Pediatr, 2000 Jun;46(3):172-5.
    PMID: 10893920
    A case-control study was carried out on 97 consecutive preterm (< 37 weeks) infants to determine predictors associated with failure of nasal continuous positive airway pressure (CPAP) in the treatment of respiratory distress syndrome (RDS). Logistic regression analysis showed that only three risk factors were significantly associated with failed CPAP. These were: moderate or severe RDS (odds ratio: 5.9; 95 per cent confidence interval (CI): 2.2-16.0); septicemia during CPAP therapy (OR: 8.8; 95 per cent: CI 1.5-50.7); and pneumothorax during CPAP therapy (odds ratio: 6.9; 95 per cent: CI 1.1-41.7).
  12. Zarina AL, Hamidah A, Zulkifli SZ, Zulfiqar MA, Jamal R
    Singapore Med J, 2007 Dec;48(12):e320-2.
    PMID: 18043827
    Pancreatic carcinoid tumours are rare, particularly within the paediatric population. The clinical presentation is largely dependent on the functionality of the tumour. Although the tumour is generally slow-growing, surgical resection is still the mainstay of curative treatment. Morbidity is, however, significantly contributed by secretion of excess hormones; in view of this, biotherapy is an important treatment strategy. Octreotide, a somatostatin analogue, has been shown to be successful in both symptomatic control and stability of tumour progression. We report a 12-year-old girl, who presented with hypertensive crisis, and showed good response to a combination of chemotherapy and octreotide.
  13. Tan KP, Mohamad Azlan Z, Rumaisa MP, Siti Aisyah Murni MR, Radhika S, Nurismah MI, et al.
    Med J Malaysia, 2014 Apr;69(2):79-85.
    PMID: 25241817 MyJurnal
    AIM: This study was performed to determine the accuracy of ultrasound (USG) as compared to mammography (MMG) in detecting breast cancer.

    METHODS: This was a review of patients who had breast imaging and biopsy during an 18-month period. Details of patients who underwent breast biopsy were obtained from the department biopsy record books and imaging request forms. Details of breast imaging findings and histology of lesions biopsied were obtained from the hospital Integrated Radiology Information System (IRIS). Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy of USG and MMG were calculated with histology as the gold standard.

    RESULTS: A total of 326 breast lesions were biopsied. Histology results revealed the presence of 74 breast cancers and 252 benign lesions. USG had a sensitivity of 82%, specificity of 84%, PPV = 60%, NPV = 94% and an accuracy of 84%. MMG had a sensitivity of 49%, specificity of 89%, PPV = 53%, NPV = 88% and an accuracy of 81%. A total of 161 lesions which were imaged with both modalities were analyzed to determine the significance in the differences in sensitivity and specificity between USG and MMG. Sensitivity of USG (75%) was significantly higher than sensitivity of MMG (44%) (X(2)1=6.905, p=0.014). Specificity of MMG (91%) was significantly higher than specificity of USG (79%) (X(2)1=27.114, p<0.001). Compared with MMG, the sensitivity of USG was 50% (95% CI 10%-90%) higher in women aged less than 50 years (X(2)1=0.000, p=1.000) and 27% (95% CI 19%-36%) higher in women aged 50 years and above (X(2)1=5.866, p=0.015). Compared with MMG, the sensitivity of USG was 40% (95% CI 10%-70%) higher in women with dense breasts (X(2)1=0.234, p=0.628) and 27% (95% CI 9%-46%) higher in women with non-dense breasts (X(2)1=4.585, p=0.032).

    CONCLUSION: Accuracy of USG was higher compared with MMG. USG was more sensitive than MMG regardless of age group. However, MMG was more specific in those aged 50 years and older. USG was more sensitive and MMG was more specific regardless of breast density. In this study, 20% of breast cancers detected were occult on MMG and seen only on USG.
  14. Zulfiqar MA, Noryati M, Hamzaini AH, Thambidorai CR
    Med J Malaysia, 2006 Jun;61(2):199-203.
    PMID: 16898311 MyJurnal
    The purpose of this study was to determine the effectiveness of pneumatic reduction of intussusception using equipment readily available in the hospital. Twenty-two children aged between four months and four years had pneumatic reduction of intussusception. The device used was assembled using (i) a hand-held pump attached to a pressure gauge, and (ii) a 3-way Foley's balloon catheter. There was a 73% success rate and there were no complications. The device used was effective and safe for the pneumatic reduction of intussusception.
  15. Faizah MZ, Hamzaini AH, Kanaheswari Y, Dayang A AA, Zulfiqar MA
    Med J Malaysia, 2015 Oct;70(5):269-72.
    PMID: 26556113 MyJurnal
    OBJECTIVE: Contrast-enhanced ultrasound has become increasingly utilised as an alternative imaging modality for the diagnosis of vesicoureteric reflux (VUR) in paediatric patients. The study objective is to evaluate the efficacy of contrast enhanced Voiding Urosonography (ce-VUS) compared with fluoroscopic micturating cystourethrography (MCU) in the detection of VUR.
    METHODS: This prospective study was carried out between July 2011 and January 2013 on paediatric patients who underwent MCU. All consented patients would undergo ce- VUS prior to MCU. We documented the epidemiology details, the number of Kidney-Ureter (K-U) unit studied, baseline renal and bladder sonogram, as well as presence of VUR on ce-VUR. The technique for ce-VUS was standardized using normal saline to fill the bladder prior to administration of SonoVue® (2.5 ml) to assess the kidney-ureter (K-U) unit. Dedicated contrast detection software was used to discern the presence of microbubbles in the pelvicaliceal system (PCS). The findings were then compared with MCU.
    RESULTS: 27 paediatric patients were involved in the study [17 males (63%) and 10 females (37%)] involving 55 K-U units (one patient had a complete duplex system). MCU detected VUR in 10 K-U units while ce-VUS detected VUR in 8 out of the 10 K-U units. There were 2 false negative cases (both Grade 1) with ce-VUS. The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of ce-VUS were 80%, 98%, 95%, 89% and 96%, respectively.
    CONCLUSION: ce-VUS is a sensitive and specific radiation-free alternative for the detection of VUR in the paediatric population.
  16. Salinawati B, Hing EY, Fam XI, Zulfiqar MA
    Med J Malaysia, 2015 Aug;70(4):238-42.
    PMID: 26358021 MyJurnal
    AIM: To determine the (i) sensitivity and specificity of ultrasound (USG) in the detection of urinary tract calculi, (ii) size of renal calculi detected on USG, and (iii) size of renal calculi not seen on USG but detected on computed tomography urogram (CTU).
    METHODS: A total of 201 patients' USG and CTU were compared retrospectively for the presence of calculi. Sensitivity, specificity, accuracy, positive predictive value and negative predictive value of USG were calculated with CTU as the gold standard.
    RESULTS: From the 201 sets of data collected, 59 calculi were detected on both USG and CTU. The sensitivity and specificity of renal calculi detection on USG were 53% and 85% respectively. The mean size of the renal calculus detected on USG was 7.6 mm ± 4.1 mm and the mean size of the renal calculus not visualised on USG but detected on CTU was 4 mm ± 2.4 mm. The sensitivity and specificity of ureteric calculi detection on USG were 12% and 97% respectively. The sensitivity and specificity of urinary bladder calculi detection on USG were 20% and 100% respectively.
    CONCLUSION: This study showed that the accuracy of US in detecting renal, ureteric and urinary bladder calculi were 67%, 80% and 98% respectively.
    Study site: Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur
  17. Sridharan R, Yunos SM, Aziz S, Hussain RI, Alhabshi SM, Suria Hayati MP, et al.
    Med J Malaysia, 2015 Dec;70(6):326-33.
    PMID: 26988204 MyJurnal
    OBJECTIVE: The aim of this study was to compare the use of semi-automated (Medax Velox 2; Poggio Rusco, Italy) and automated (Bard Magnum Biopsy Instrument; Covington, GA, USA) core biopsy needles, for ultrasound guided breast biopsy.
    MATERIALS AND METHODS: A 14G semi-automatic spring loaded core biopsy needle with a 22-mm-throw (Medax Velox 2; Poggio Rusco, Italy) and 14-gauge automated needle device with a 22-mm-throw biopsy gun (Bard-Magnum Biopsy Instrument, Covington, GA, USA) were used for breast biopsies under ultrasound guidance on alternate months during the study period between July 2009 and May 2011. One hundred and sixty lesions were biopsied and specimens were sent for histological evaluation.
    RESULTS: The automated needle obtained a higher number of histology reports at 84% (67/80) as compared with the semiautomated needle at 60% (48/80) (Fisher exact test, p value=0.023). Inadequate samples with the automated needle were much less at 9% (7/60) than with the semiautomated needle at 23% (18/60) (Fisher exact test, p value=0.028). The semi-automated needle showed slightly less fragmented samples. However, the number of fragmented samples with definitive diagnosis was slightly higher with the automated compared with the semiautomated needle, at 16% (13/80) and 13% (10/80) respectively. Compared with histology of 29 lesions that were excised, the semi-automated needle had higher sensitivity (100%) but lower specificity (75%) and accuracy (90%) compared with the automated needle (88% sensitivity, 100% specificity, 95% accuracy).
    CONCLUSION: Definitive diagnosis from the study samples slightly favours the use of automated core biopsy needle as compared to semi-automated core biopsy needle.
    Study site: Universiti Kebangsaan Malaysia Medical Centre, Kuala Lumpur
  18. Nadzri M, Hing EY, Hamzaini AH, Faizah MZ, AbAziz A, Kanaheswari Y, et al.
    Med J Malaysia, 2015 Dec;70(6):346-50.
    PMID: 26988207 MyJurnal
    BACKGROUND: to determine the usefulness of Doppler ultrasound measurement of resistive index (RI) in differentiating obstructive from non-obstructive hydronephrosis in children.
    METHODS: From August 2011 to November 2012, renal Doppler assessments of the intra-renal renal arteries were performed on 16 children (19 kidneys) with congenital hydronephrosis. the independent t-test was used to assess for significant difference in RI values between those with obstructive hydronephrosis (6 kidneys) and those with non-obstructive hydronephrosis (13 kidneys) as determined by dynamic renal scintigraphy. the assessor was blinded to the clinical findings and scintigraphy results.
    RESULTS: RI was significantly different between obstructive and non-obstructive hydronephrosis. Obstructive hydronephrosis returned higher RI values, with mean RI of 0.78. Mean RI in non-obstructive hydronephrosis was 0.70, and the difference was significant (p <0.05). the sensitivity and specificity of Doppler ultrasound were 100% and 53% respectively.
    CONCLUSION: Doppler ultrasound measurement of resistive index is useful in differentiating obstructive from nonobstructive hydronephrosis and provides an alternative non-ionizing investigation.
    Study site: Universiti Kebangsaan Malaysia
    Medical Centre, Kuala Lumpur, Malaysia
  19. Zulfiqar MA, Zaleha AM, Zulkifli I, Chia WY, Samad SA
    Med J Malaysia, 1998 Sep;53(3):284-7.
    PMID: 10968168
    Three children aged 3-11 years had ultrasonography of the urinary tract for the investigation of dysuria and haematuria. A bladder mass was seen in these 3 children. One child had computed tomography scan, cystoscopy and bladder biopsy because rhabdomyosarcoma was considered. The biopsy revealed an inflammatory process. The urine culture of the other 2 children revealed E. coli. On ultrasonography, the inflammatory mass may appear homogeneously hypoechoic or may contain moderate level echoes. The mucosal surface of the mass may be smooth or lobulated. It is important to consider an infective cause for a bladder mass in children because computed tomography, cystoscopy and biopsy may be avoided.
Related Terms
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links