Displaying publications 1 - 20 of 36 in total

Abstract:
Sort:
  1. Ali RM, Degenhardt R, Zambahari R, Tresukosol D, Ahmad WA, Kamar Hb, et al.
    EuroIntervention, 2011 May;7 Suppl K:K83-92.
    PMID: 22027736 DOI: 10.4244/EIJV7SKA15
    Coronary lesions in diabetics (DM) are associated with a high recurrence following percutaneous coronary intervention (PCI), even after drug-eluting stent (DES) deployment. Encouraging clinical data of the drug-eluting balloon catheter (DEB) SeQuent Please warrant its investigation in these patients.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*; Angioplasty, Balloon, Coronary/mortality
  2. Ali RM, Abdul Kader MASK, Wan Ahmad WA, Ong TK, Liew HB, Omar AF, et al.
    JACC Cardiovasc Interv, 2019 Mar 25;12(6):558-566.
    PMID: 30898253 DOI: 10.1016/j.jcin.2018.11.040
    OBJECTIVES: The aim of this randomized controlled trial was to investigate a novel sirolimus-coated balloon (SCB) compared with the best investigated paclitaxel-coated balloon (PCB).

    BACKGROUND: Treatment of coronary in-stent restenosis (ISR) remains challenging. PCBs are an established treatment option outside the United States with a Class I, Level of Evidence: A recommendation in the European guidelines. However, their efficacy is better in bare-metal stent (BMS) ISR compared with drug-eluting stent (DES) ISR.

    METHODS: Fifty patients with DES ISR were enrolled in a randomized, multicenter trial to compare a novel SCB (SeQuent SCB, 4 μg/mm2) with a clinically proven PCB (SeQuent Please Neo, 3 μg/mm2) in coronary DES ISR. The primary endpoint was angiographic late lumen loss at 6 months. Secondary endpoints included procedural success, major adverse cardiovascular events, and individual clinical endpoints such as stent thrombosis, cardiac death, target lesion myocardial infarction, clinically driven target lesion revascularization, and binary restenosis.

    RESULTS: Quantitative coronary angiography revealed no differences in baseline parameters. After 6 months, in-segment late lumen loss was 0.21 ± 0.54 mm in the PCB group versus 0.17 ± 0.55 mm in the SCB group (p = NS; per-protocol analysis). Clinical events up to 12 months also did not differ between the groups.

    CONCLUSIONS: This first-in-man comparison of a novel SCB with a crystalline coating shows similar angiographic outcomes in the treatment of coronary DES ISR compared with a clinically proven PCB. (Treatment of Coronary In-Stent Restenosis by a Sirolimus [Rapamycin] Coated Balloon or a Paclitaxel Coated Balloon [FIM LIMUS DCB]; NCT02996318).

    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*
  3. Azarisma, S.M.S., Rosli, M.A.B.
    MyJurnal
    We report a-56-year old army pensioner who presented initially to a peripheral hospital with acute ST-elevation inferior myocardial infarction thrombolysed with streptokinase. He was subsequently referred to the National Heart Institute (Institut Jantung Negara, Malaysia) for coronary revascularization. Coronary angiogram revealed an ectatic right coronary artery with discrete lesions at the proximal and distal segments stented with bare metal stents (BMS). Post dilatation shots revealed a wire-induced, distal dissection at the posterior left ventricular artery remedied by balloon angioplasty but resulting in balloon-induced crumpling of the distal BMS. We discuss the importance of sequential, distal-to-proximal coronary intervention, stent crumpling and remedial strategies.
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  4. Bonaventura K, Schwefer M, Yusof AKM, Waliszewski M, Krackhardt F, Steen P, et al.
    Adv Ther, 2020 05;37(5):2210-2223.
    PMID: 32274746 DOI: 10.1007/s12325-020-01320-2
    INTRODUCTION: Scoring balloon angioplasty (SBA) for lumen gain prior to stent implantations or drug-coated balloon angioplasty (DCB) is considered an essential interventional tool for lesion preparation. Recent evidence indicates that SBA may play a pivotal role in enhancing the angiographic and clinical outcomes of DCB angioplasty.

    METHODS: We studied the systematic use of SBA with a low profile, non-slip element device prior to DCB angioplasty in an unselected, non-randomized patient population. This prospective, all-comers study enrolled patients with de novo lesions as well as in-stent restenotic lesions in bare metal stents (BMS-ISR) and drug-eluting stents (DES-ISR). The primary endpoint was the target lesion failure (TLF) rate at 9 months (ClinicalTrials.gov Identifier NCT02554292).

    RESULTS: A total of 481 patients (496 lesions) were recruited to treat de novo lesions (78.4%, 377), BMS-ISR (4.0%, 19), and DES-ISR (17.6%, 85). Overall risk factors were acute coronary syndrome (ACS, 20.6%, 99), diabetes mellitus (46.8%, 225), and atrial fibrillation (8.5%, 41). Average lesion lengths were 16.7 ± 10.4 mm in the de novo group, and 20.1 ± 8.9 mm (BMS-ISR) and 16.2 ± 9.8 mm (DES-ISR) in the ISR groups. Scoring balloon diameters were 2.43 ± 0.41 mm (de novo), 2.71 ± 0.31 mm (BMS-ISR), and 2.92 ± 0.42 mm (DES-ISR) whereas DCB diameters were 2.60 ± 0.39 mm (de novo), 3.00 ± 0.35 mm (BMS-ISR), and 3.10 ± 0.43 mm (DES-ISR), respectively. The overall accumulated TLF rate of 3.0% (14/463) was driven by significantly higher target lesion revascularization rates in the BMS-ISR (5.3%, 1/19) and the DES-ISR group (6.0%, 5/84). In de novo lesions, the TLF rate was 1.1% (4/360) without differences between calcified and non-calcified lesions (p = 0.158) and small vs. large reference vessel diameters with a cutoff value of 3.0 mm (p = 0.901).

    CONCLUSIONS: The routine use of a non-slip element scoring balloon catheter to prepare lesions suitable for drug-coated balloon angioplasty is associated with high procedural success rates and low TLF rates in de novo lesions.

    Matched MeSH terms: Angioplasty, Balloon, Coronary/instrumentation*; Angioplasty, Balloon, Coronary/methods*; Angioplasty, Balloon, Coronary/standards*
  5. Boo YL, Liam CCK, Lim SY, Look ML
    Hong Kong Med J, 2019 Feb;25(1):74-5.
    PMID: 30713145 DOI: 10.12809/hkmj176972
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  6. Campos CM, Caixeta A, Franken M, Bartorelli AL, Whitbourn RJ, Wu CJ, et al.
    Catheter Cardiovasc Interv, 2018 02 15;91(3):387-395.
    PMID: 28471086 DOI: 10.1002/ccd.27109
    OBJECTIVES: to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA) BACKGROUND: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon.

    METHODS: The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR).

    RESULTS: After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups.

    CONCLUSION: In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES. © 2017 Wiley Periodicals, Inc.

    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*; Angioplasty, Balloon, Coronary/mortality
  7. Chee KH, Siaw FS, Chan CG, Chong WP, Imran ZA, Haizal HK, et al.
    Int J Clin Pract, 2005 Jun;59(6):628-31.
    PMID: 15924588
    This single centre study was designed to demonstrate feasibility, safety and efficacy of the Vivant Z stent (PFM AG, Cologne, Germany). Patients with de novo lesion were recruited. Coronary angioplasty was performed with either direct stenting or after balloon predilatation. Repeated angiogram was performed 6 months later or earlier if clinically indicated. Between January to June 2003, a total of 50 patients were recruited (mean age 55.8 +/- 9 years). A total of 52 lesions were stented successfully. Mean reference diameter was 2.77 mm (+/-0.59 SD, range 2.05-4.39 mm) with mean target lesion stenosis of 65.5% (+/-11.6 SD, range 50.1-93.3%). Forty-six lesions (88.5%) were American College of Cardiologist/American Heart Association class B/C types. Direct stenting was performed in 18 (34.6%) lesions. Mean stent diameter was 3.18 mm (+/-0.41 SD, range 2.5-4 mm), and mean stent length was 14.86 mm (+/-2.72 SD, range 9-18 mm). The procedure was complicated in only one case which involved the loss of side branch with no clinical sequelae. All treated lesions achieved Thrombolysis In Myocardial Infarction 3 flow. Mean residual diameter stenosis was 12.2% (+/-7.55 SD, range 0-22.6%) with acute gain of 1.72 mm (+/-0.50 SD, range 0.5-2.8). At 6 months, there was no major adverse cardiovascular event. Repeated angiography after 6 months showed a restenosis rate of 17% (defined as >50% diameter restenosis). Mean late loss was 0.96 mm (+/-0.48 SD) with loss index of 0.61 (+/-0.38 SD). The restenosis rate of those lesions less than 3.0 mm in diameter was 22.2% compared with 6.25% in those lesions more than 3.0 mm in diameter. The Vivant Z stent was shown to be safe and efficacious with low restenosis rate in de novo coronary artery lesion.
    Matched MeSH terms: Angioplasty, Balloon, Coronary*
  8. Chin K
    EuroIntervention, 2011 May;7 Suppl K:K43-6.
    PMID: 22027726 DOI: 10.4244/EIJV7SKA7
    In-stent restenosis remains an important issue even in the drug-eluting stent (DES) era today. In recent years, drug-eluting balloons (DEB) have emerged as a potential alternative to the treatment of in-stent restenosis. Paclitaxel was identified as the primary drug for DEB because of its rapid uptake and prolonged retention. Non-stent-based local drug delivery using DEB maintains the antiproliferation properties of DES, but without the limitations of DES such as subacute stent thrombosis, stent fractures, prolonged antiplatelet therapy and more importantly, avoiding a "stent-in-a-stent" approach. The first major impact of drug-eluting balloon (DEB) in the management of bare metal instent restenosis was the "PACCOCATH ISR I" randomised trial, comparing the efficacy of drug-eluting balloon versus uncoated balloon. The six months angiographic results showed a binary restenosis of 5% and 4% MACE in the drug-eluting balloon group, compared with 43% binary restenosis and 31% MACE, in the uncoated balloon group (p=0.002 and 0.02). The second major DEB trial is the "PEPCAD II Trial", comparing the efficacy of the SeQuent Please DEB with the Taxus drug-eluting stent in the treatment of bare-metal stent instent restenosis. At 6-month follow-up, in-segment late lumen loss was 0.38 ± 0.61 mm in the DES group versus 0.17 ± 0.42 mm (p=0.03) in the DEB group, resulting in a binary restenosis rate of 12/59 (20%) versus 4/57 (7%; p=0.06). At 12 months, MACE rates were 22% in the Taxus group and 9% in the DEB group (P=0.08). The TLR at 12 months was 15% in the Taxus group and 6% in the DEB group (p=0.15). Based on these two pivotal trials, the European Society of Cardiology Guidelines for Percutaneous Coronary Intervention (2010) recommended that DEB should be considered for the treatment of in-stent restenosis after prior bare-metal stent. This was accorded a class 2 IIa indication, with a level B evidence.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*
  9. Chong E, Shen L, Tan HC, Poh KK
    Med J Malaysia, 2011 Aug;66(3):249-52.
    PMID: 22111450
    Thrombolysis in Myocardial Infarction (TIMI) score has been used to predict outcomes in patients presenting with unstable angina (UA) and non-ST elevation myocardial infarction (NSTEMI). Our study assessed other clinical predictors for patients with UA/NSTEMI undergoing early percutaneous coronary intervention (PCI).
    Matched MeSH terms: Angioplasty, Balloon, Coronary*
  10. Choo GH
    J Interv Cardiol, 2009 Apr;22(2):117-20.
    PMID: 19379469 DOI: 10.1111/j.1540-8183.2009.00443.x
    Percutaneous bifurcation intervention is usually sufficient with a single-stent strategy. When the double-stent strategy is employed, higher restenosis and target lesion revascularization (TLR) rates are observed, especially at the side-branch ostium. The results may be improved, however, with refinement in techniques, for example, final kissing balloon inflation and double kissing balloon inflation.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/methods*
  11. Choo GH, Le D, Nguyen K, Phan H, Nguyen Q, Nguyen J
    Chin Med J (Engl), 2012 Oct;125(19):3565-8.
    PMID: 23044325
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  12. Devasia T, Shetty PN, Kareem H, Karkala YR, Singh A
    Indian Heart J, 2018 Dec;70 Suppl 3(Suppl 3):S353-S358.
    PMID: 30595288 DOI: 10.1016/j.ihj.2018.10.411
    BACKGROUND: Lifestyle modification (LSM) such as prudent diet, physical activity, avoidance of smoking, and maintaining a healthy weight may considerably decrease the risk for coronary artery disease.

    OBJECTIVE: The primary objective of this study was to develop a new LSM scoring system and investigate the correlation between adherence to LSM and incidence of major adverse cardiac events (MACEs) at 12-month follow-up.

    METHOD: A total of 1000 consecutive patients who underwent percutaneous transluminal coronary angioplasty (PTCA) were included in this prospective single-center study. Manipal lifestyle modification score (MLSMS) was developed by using five lifestyle-related factors. Adherence to LSM at the baseline and subsequent follow-ups was determined by using MLSMS. The MACE at 1-, 6-, and 12-month follow-up were analyzed.

    RESULTS: There was a significant reduction in overall adherence to LSM (p 

    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects*
  13. Foo CY, Reidpath DD, Chaiyakunapruk N
    Syst Rev, 2016 08 02;5(1):130.
    PMID: 27484905 DOI: 10.1186/s13643-016-0304-7
    BACKGROUND: Acute myocardial infarction (AMI) is a medical emergency in which sudden occlusion of coronary artery(ies) results in ischemia and necrosis of the cardiac tissues. Reperfusion therapies that aim at reopening the occluded artery remain the mainstay of treatment for AMI. Primary percutaneous coronary intervention (PCI), which enables the restoration of blood flow by reopening the occluded artery(ies) via a catheter with an inflatable balloon, is currently the preferred treatment for AMI with ST segment elevation (STEMI). The door-to-balloon (D2B) delay refers to the time interval counting from the arrival of a patient with STEMI at a hospital to the time of the balloon inflation (or stent deployment) that reopens the occluded artery(ies). Reducing this delay in primary PCI is thought to be an important strategy toward achieving better patient outcomes. Unfortunately, significant reduction of D2B delay in the USA over the last decade has not been shown to be associated with improved STEMI mortality. It has been suggested that the lack of impact could be due to the expanding use of primary PCI in STEMI as well as the survival cohort effect, leading to a shift toward a higher risk population receiving the procedure. Others have suggested that reduction in D2B delay may not be as impactful as expected, given that it only represents a small fraction of the total ischemic time. Although most existing evidence have pointed to the presence of a beneficial effect of shorter D2B delay, some inconsistencies however exist. This study aims to synthesize available evidence in order to answer the following questions: (1) what is the overall effect of D2B delay on clinical outcomes in patients with STEMI treated with primary PCI? (2) What factors explain the differences of the effect estimates among the studies? (3) What are the important strength and limitation of the existing body of evidence?

    METHOD: We will search PubMed/MEDLINE, EMBASE, ClinicalTrials.gov, WHO International Clinical Trials Registry, CINAHL Database, and the Cochrane Library using a predefined search strategy. Other sources of literature will include proceedings from the European Society of Cardiology, the American College of Cardiology, the American Heart Association, the EUROPCR, and the ProQuest Dissertations and Theses Database. We will include data from observational studies (case-control and cohort study design) and randomized control trials (that have investigated the relationship of D2B time and clinical outcome(s) in an adult (older than 18) STEMI population). Mortality (cardiac related and all-cause) and incidence heart failure (HF) have been prioritized as the primary outcomes. All eligible studies will be assessed for risk of bias using the Risk Of Bias in Non-randomized Studies - of Interventions tool. The Grading of Recommendations, Assessment, and Evaluation (GRADE) framework will be used to report the quality of evidence and strength of recommendations. We will proceed to analyze the data quantitatively if the pre-specified conditions are satisfied.

    DISCUSSION: Recent discussion on the negative findings of improved D2B delay over time being unrelated to better STEMI outcomes at the population level has reminded us of an important knowledge gap we have on this domain. This systematic review will serve to address some of these key questions not previously examined. Answers to these questions could clarify the controversies and offer empirical support for or against the suggested hypotheses.

    SYSTEMATIC REVIEW REGISTRATION: PROSPERO CRD42015026069.

    Matched MeSH terms: Angioplasty, Balloon, Coronary/methods*
  14. Jeger RV, Eccleshall S, Wan Ahmad WA, Ge J, Poerner TC, Shin ES, et al.
    JACC Cardiovasc Interv, 2020 06 22;13(12):1391-1402.
    PMID: 32473887 DOI: 10.1016/j.jcin.2020.02.043
    Although drug-eluting stents are still the default interventional treatment of coronary artery disease, drug-coated balloons (DCBs) represent a novel alternative therapeutic strategy in certain anatomic conditions. The effect of DCBs is based on the fast and homogenous transfer of antiproliferative drugs into the vessel wall during single balloon inflation by means of a lipophilic matrix without the use of permanent implants. Although their use is established for in-stent restenosis of both bare-metal and drug-eluting stents, recent randomized clinical data demonstrate a good efficacy and safety profile in de novo small-vessel disease and high bleeding risk. In addition, there are other emerging indications (e.g., bifurcation lesions, large-vessel disease, diabetes mellitus, acute coronary syndromes). Because the interaction among the different delivery balloon designs, doses, formulations, and release kinetics of the drugs used is important, there seems to be no "class effect" of DCBs. On the basis of the amount of recently published data, the International DCB Consensus Group provides this update of previous recommendations summarizing the historical background, technical considerations such as choice of device and implantation technique, possible indications, and future perspectives.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects; Angioplasty, Balloon, Coronary/instrumentation*; Angioplasty, Balloon, Coronary/mortality
  15. Lee CY, Hairi NN, Wan Ahmad WA, Ismail O, Liew HB, Zambahari R, et al.
    PLoS One, 2013;8(8):e72382.
    PMID: 24015238 DOI: 10.1371/journal.pone.0072382
    To assess whether gender differences exist in the clinical presentation, angiographic severity, management and outcomes in patients with coronary artery disease (CAD).
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  16. Lee ZV, Arjan Singh RS
    Cureus, 2021 Jan 07;13(1):e12542.
    PMID: 33425567 DOI: 10.7759/cureus.12542
    Transient cortical blindness after coronary angiography has long been reported in the literature; however, this condition remains rare until today. We report a case of transient cortical blindness after coronary angiography, bypass graft angiography, and coronary angioplasty, which was deemed to be secondary to contrast agent. A 60-year-old man who underwent prior coronary artery bypass grafting (CABG) started to experience recurrence of exertional and resting chest pain one year after CABG. In addition to coronary artery disease, he has underlying type 2 diabetes mellitus, hypertension, and dyslipidemia. Due to technical reasons, he was unable to undergo a computed tomography (CT) angiography of the coronary arteries and bypass grafts. Invasive coronary and bypass graft angiography were done, followed by stenting of the left circumflex artery. Thirty minutes after completion of the procedure, the patient had bilateral blurring of vision, which worsened drastically to only being able to perceive light bilaterally. The patient otherwise did not have any other neurological deficits. Binocular indirect ophthalmoscopy revealed no significant abnormalities apart from mild non-proliferative diabetic retinopathy of the left eye. A non-contrasted CT scan of the brain revealed acute subarachnoid bleed in both occipital lobes, but a subsequent magnetic resonance imaging scan of the brain revealed no evidence of intracranial bleed. The patient's vision gradually improved eight hours after the index event, and his vision completely normalized 12 hours later. The patient was discharged well two days later, and at one-month, three-month, and six-month follow-up, the patient remained angina-free, and his vision had remained stable bilaterally.
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  17. Liew HB, Rosli MA, Wan Azman WA, Robaayah Z, Sim KH, NCVD PCI investigators
    Med J Malaysia, 2008 Sep;63 Suppl C:41-4.
    PMID: 19230246
    The National Cardiovascular Database for Percutaneous Coronary Intervention (NCVD PCI) Registry is the first multicentre interventional cardiology project, involving the main cardiac centres in the country. The ultimate goal of NCVD PCI is to provide a contemporary appraisal of PCI in Malaysia. This article introduces the foundation, the aims, methodology, database collection and preliminary results of the first six-month database.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/statistics & numerical data*
  18. Loch A, Bewersdorf JP, Veeriah RS
    Indian Heart J, 2017 03 17;69(5):651-654.
    PMID: 29054192 DOI: 10.1016/j.ihj.2017.03.002
    The LEADERS FREE trial concluded that the polymer free drug-coated BioFreedom™ stent appeared to be both safer and more effective than bare-metal stents (BMS) with an ISR rate comparable to traditional DES without the need for prolonged DAPT. We implanted 45 BioFreedom™ stents in 34 patients over a 4-month period. 4 patients represented early (106-238 days after the implant procedure) with angina symptoms and severe ISR was detected in all patients. The rate of severe and early ISR detected in our patient population of 11.8% is comparable to that of traditional BMS. Further studies are warranted.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/methods*
  19. Ng SC, Sawatt C, Foo LK, Hitam O, Khor PG, Lee YK
    Med J Malaysia, 1996 Mar;51(1):75-9.
    PMID: 10967983
    This is a review of the first 100 coronary stents implanted for the indications of PTCA restenosis, acute or threatened closure and De Novo lesions. The success rates were high and complications rates were low. Subacute stent thrombosis rates were low and stenting for De Novo lesions in > 3.0 mm arteries provide the best short and long term results. Six months restenosis rate was low. Stent assisted high pressure balloon angioplasty is an important advance.
    Matched MeSH terms: Angioplasty, Balloon, Coronary
  20. Ngow H
    Kardiol Pol, 2009 Sep;67(9):1040-2 discussion 1043.
    PMID: 19838965
    Coronary artery stent dislodgement during angioplasty is a rare complication. Stent dislodgement was more frequent in the past when stents were manually crimped onto the balloon. Newer and improved balloon-mounted stents with better radio-opacity have reduced the incidence of stent dislodgement but do not completely eliminate it. We report a case of balloon-mounted stent dislodgement in the proximal left anterior descending (LAD) coronary artery prior to deployment. This patient however was successfully treated with re-wiring of the artery with two parallel wires and the stent's reposition prior to deployment with the help of a small balloon.
    Matched MeSH terms: Angioplasty, Balloon, Coronary/adverse effects*