Displaying publications 1 - 20 of 45 in total

Abstract:
Sort:
  1. Ailin Razali, M. S. Othman, M. S. Rahman, N. F.I. Misaridin
    MyJurnal
    Recreational noise exposure has become a major threat to the hearing system, and this
    includes exposure to loud noise during group exercises such as Zumba Fitness, where loud music plays an
    important role. This study aimed to assess the noise exposure and hearing threshold profile among Zumba
    Fitness regulars in Kuantan, Malaysia. MATERIALS AND METHODS: Noise exposure and hearing profile
    threshold were measured during Zumba Fitness sessions at a fitness studio in Kuantan, Malaysia from 24th
    June 2014 to 12th August 2014. Noise exposure was measured using a noise dosimeter for one hour of Zumba
    Fitness session with a total of nine sessions run by three different instructors while sound level pressure was
    taken using a sound level meter during ambient, peak session and during cooling down. Thirty participants
    answered questionnaires and underwent pure tone diagnostic audiometry test at a local clinic for hearing
    threshold documentation. RESULTS: Some areas of the hall posed higher risks of causing noise-induced
    hearing loss especially near the amplifiers. There were periods when the hearing level exceeded 115 dBA.
    Early abnormal pattern could be observed in the hearing profiles of some of the participants to suggest
    preliminary hearing problems. CONCLUSION: Zumba Fitness regulars have a risk of developing noise-induced
    hearing loss and preventive steps should be properly addressed as NIHL is permanent and irreversible.
    Matched MeSH terms: Audiometry, Pure-Tone
  2. Akmaliza Ali, Ellin Fariza Selamat
    MyJurnal
    Kajian terdahulu mendapati Respons Auditori Keadaan Mantap (ASSR) mempunyai variasi yang besar dalam meramal ambang pendengaran, manakala kebolehulangan ASSR masih kurang dilaporkan. Kajian ini bertujuan untuk menentukan kebolehulangan ASSR dalam menilai ambang pendengaran golongan dewasa lanjut umur yang bermasalah pendengaran sensorineural. Seramai 15 orang subjek berumur antara 55 hingga 75 tahun terlibat dalam kajian ini. Ambang pendengaran ditentukan menggunakan audiometri nada tulen (PTA) dan ASSR pada frekuensi 0.5, 1, 2 dan 4 kHz, di mana ASSR diulang pada 0.5 dan 1 kHz. Secara keseluruhannya, nilai ambang ASSR adalah lebih tinggi daripada PTA. ANOVA satu hala menunjukkan perbezaan antara ambang PTA dan ASSR adalah tidak signifikan pada semua frekuensi. Terdapat korelasi yang signifikan antara ambang PTA dan ambang ASSR pada 0.5 kHz (r = 0.77, p < 0.05), 1 kHz (r = 0.45, p < 0.05), 2 kHz (r = 0.58, p < 0.05) dan 4 kHz (r = 0.73, p < 0.05). Ujian t berpasangan menunjukkan tiada perbezaan signifikan antara ujian ASSR pertama dan ASSR ulangan pada frekuensi 0.5 kHz (t = 2.09, p > 0.05) dan 1 kHz (t = 0.436, p > 0.05). Korelasi Pearson menunjukkan korelasi yang sederhana di antara dua pengukuran ASSR pada 0.5 kHz (r = 0.68, p < 0.001) dan 1 kHz (r = 0.60, p < 0.001). Hasil kajian ini mendapati bahawa ambang pendengaran ASSR tidak berubah secara signifikan jika diulang uji dan ujian ASSR boleh disarankan sebagai alternatif kepada PTA dalam menentukan ambang pendengaran golongan dewasa lanjut usia bermasalah pendengaran sensorineural.
    Matched MeSH terms: Audiometry, Pure-Tone
  3. Ami M, Abdullah A, Awang MA, Liyab B, Saim L
    Laryngoscope, 2008 Apr;118(4):712-7.
    PMID: 18176342 DOI: 10.1097/MLG.0b013e318161e521
    To investigate cochlear outer hair cell function based on distortion product otoacoustic emission (DPOAE) in patients with tinnitus.
    Matched MeSH terms: Audiometry, Pure-Tone
  4. Arvin B, Prepageran N, Raman R
    Indian J Otolaryngol Head Neck Surg, 2013 Dec;65(Suppl 3):480-4.
    PMID: 24427701 DOI: 10.1007/s12070-011-0356-x
    The objective of this study is to determine whether presbycusis occurs much earlier than previously believed if the high frequency (above 8 kHz) are included. Tertiary referral center (a teaching University). This is a cross-sectional observational study. Healthy adults from 20 to 49 years of age who had essentially normal hearing were included into the study. They were subjected to high frequency pure tone audiometry (until 16 kHz). Participants were grouped based on age ranges of 10 years (e.g., 20-29, 30-39, and 40-49) and the presence of symmetrical high frequency sensor neural hearing loss were documented. There is a significant presence of symmetrical high frequency sensor neural hearing loss (not attributed to any known risk factors) as early as from the age group of 40 to 49 years. Seven of 43 participants (16%) from age group of 20 to 29 years and 12 of 24 participants (50%) from age group of 30 to 39 years had significant high frequency hearing loss. High frequency hearing loss (high frequency Presbycusis) may occur much earlier than previously believed.
    Matched MeSH terms: Audiometry, Pure-Tone
  5. Asma A, Anouk H, Luc VH, Brokx JP, Cila U, Van De Heyning P
    Int J Pediatr Otorhinolaryngol, 2010 May;74(5):474-81.
    PMID: 20189254 DOI: 10.1016/j.ijporl.2010.01.023
    To discuss the clinical approach in managing patients with large vestibular aqueduct syndrome.
    Matched MeSH terms: Audiometry, Pure-Tone
  6. Aziz A, Md Daud MK, Nik Othman NA, Abd Rahman N
    Otol Neurotol, 2020 09;41(8):e989-e992.
    PMID: 32472918 DOI: 10.1097/MAO.0000000000002725
    BACKGROUND: Presbycusis is an age-related sensorineural hearing loss and it may reduce quality of life. We conducted a study to establish the prevalence of high-frequency presbycusis in normal hearing individuals and to validate the role of extended high-frequency distortion product otoacoustic emission (DPOAE) in the screening.

    METHOD: A cross-sectional study was conducted among 205 normal hearing adult participants with an age range between 25 and 54 years old. Hearing analysis with extended high-frequency pure-tone audiometry (PTA) and high-frequency DPOAE was carried out for all eligible participants. High-frequency presbycusis was considered to be present when the impairment of more than 25 dB occurs at higher than 8 kHz frequencies on both ears.

    RESULTS: Prevalence of high-frequency presbycusis using extended PTA was 31.7 (95% CI: 25.3, 38.1) and using high-frequency DPOAE was 57.4 (95% CI: 50.7, 64.4). The sensitivity and specificity of high-frequency DPOAE in detecting high-frequency presbycusis were 72.3 and 49.3% respectively with positive predictive value of 39.8% and negative predictive value of 79.3%. The association between age and high-frequency presbycusis was significant based on high-frequency DPOAE (p = 0.029).

    CONCLUSIONS: The prevalence of high-frequency hearing loss is higher with increasing in age. High-frequency DPOAE may be used as a screening tool followed by confirmation using extended PTA. The early detection of presbycusis is important so that measures can be taken to prevent more severe problems developing.

    Matched MeSH terms: Audiometry, Pure-Tone
  7. Balachandran R, Prepageran N, Prepagaran N, Rahmat O, Zulkiflee AB, Hufaida KS
    J Laryngol Otol, 2012 Apr;126(4):345-8.
    PMID: 22310164 DOI: 10.1017/S0022215112000047
    The Bluetooth wireless headset has been promoted as a 'hands-free' device with a low emission of electromagnetic radiation.
    Matched MeSH terms: Audiometry, Pure-Tone
  8. Bokari S, Prepageran N, Raman R
    PMID: 23120679 DOI: 10.1007/s12070-010-0004-x
    OBJECTIVE: To determine if visual analog scale (VAS) that has been used to measure magnitude of internal states such as pain, mood and various functional capabilities can be applied for patients with hearing loss.

    MATERIALS AND METHODS: One hundred and sixty patients, aged 12-80 years with unilateral hearing loss were studied using a VAS (1-10) and pure tone audiometry (PTA) of responses to 500, 1,000 and 2,000 Hz to determine degree and type of hearing loss. The results of both were compared to determine if VAS can be used in measuring hearing loss.

    RESULTS: Patients with mild, moderate hearing loss correlate well with corresponding VAS but other degrees of hearing loss (severe and profound) have poor correlation. The best correlation between PTA and VAS were found in conductive type of hearing loss.

    CONCLUSION: This study suggest that there may be a role for VAS in mild and moderate hearing loss. This may be more applicable in rural setting as a screening procedure when audiometry is not available and can enhance clinical hearing assessment especially in mild-to-moderate conductive hearing loss.

    Matched MeSH terms: Audiometry, Pure-Tone
  9. Cheong JP, Soo SS, Manuel AM
    PMID: 27497393 DOI: 10.1016/j.ijporl.2016.06.045
    OBJECTIVE: To determine the factors contributing towards hearing impairment in patients with cleft lip/palate.

    METHOD: A prospective analysis was conducted on 173 patients (346 ears) with cleft lip and palate (CL/P) who presented to the combined cleft clinic at University Malaya Medical Centre (UMMC) over 12 months. The patients' hearing status was determined using otoacoustic emission (OAE), pure tone audiometry (PTA) and auditory brainstem response (ABR). These results were analysed against several parameters, which included age, gender, race, types of cleft pathology, impact and timing of repair surgery.

    RESULTS: The patients' age ranged from 1-26 years old. They comprised 30% with unilateral cleft lip and palate (UCLP), 28% with bilateral cleft lip and palate (BCLP), 28% with isolated cleft palate (ICP) and 14% with isolated cleft lip (ICL). Majority of the patients (68.2%) had normal otoscopic findings. Out of the 346 ears, 241 ears (70%) ears had passed the hearing tests. There was no significant relationship between patients' gender and ethnicity with their hearing status. The types of cleft pathology significantly influenced the outcome of PTA and ABR screening results (p 

    Matched MeSH terms: Audiometry, Pure-Tone
  10. Gendeh BS, Gibb AG, Aziz NS, Kong N, Zahir ZM
    Otolaryngol Head Neck Surg, 1998 Apr;118(4):551-8.
    PMID: 9560111
    A prospective study was undertaken in 16 patients with chronic renal failure on continuous ambulatory peritoneal dialysis, with 22 episodes of peritonitis treated with vancomycin, a known ototoxic agent. Twelve patients had one episode each, and four had recurrent peritonitis. Each treatment course consisted of two infusions of vancomycin (30 mg/kg body weight) in 2 L of peritoneal dialysate administered at 6-day intervals. Serum vancomycin analyzed by enzyme immunoassay showed a mean trough level of 11.00 microg/ml on day 6 and mean serum levels of 33.8 and 38.6 microg/ml about 12 hours after administration on days 1 and 7, respectively. Similar levels, well within the therapeutic range, were encountered with repeated vancomycin therapy for recurrent episodes of peritonitis, suggesting that no changes occurred in the pharmacokinetic profile of the drug. Pure-tone audiometry, electronystagmography, and clinical assessment performed during each course of treatment showed no evidence of ototoxicity even on repeated courses of vancomycin therapy. The results suggest that vancomycin therapy when given in appropriate concentrations as a single therapeutic agent is both effective and safe. We believe, however, that vancomycin administered in combination with an aminoglycoside may produce ototoxic effects that may be greatly aggravated, possibly because of synergism.
    Matched MeSH terms: Audiometry, Pure-Tone
  11. Gendeh BS, Said H, Gibb AG, Aziz NS, Kong N, Zahir ZM
    J Laryngol Otol, 1993 Aug;107(8):681-5.
    PMID: 8409715 DOI: 10.1017/s0022215100124132
    A prospective study was undertaken of 10 chronic renal failure patients on Continuous Ambulatory Peritoneal Dialysis (CAPD) complicated by repeated bouts of peritonitis treated with gentamicin. Each 10-day treatment course consisted of a 120 mg loading dose, followed by 16 mg in 21 of peritoneal dialysate, given four times a day. Serum gentamicin analysed by enzyme immunoassay showed a mean level of 5.2 micrograms/ml, (range 3.7 to 6.6 mg/ml) four hours after the loading dose. Similar levels, well within the therapeutic range, were maintained on the 3rd, 5th, 7th and 9th days of intraperitoneal gentamicin therapy, suggesting no accumulation of gentamicin in the serum. Pure tone audiometry, electronystagmography and clinical assessment were performed during each course of treatment. Although no evidence of ototoxicity was found during the first two courses of gentamicin, but disequilibrium and bobbing oscillopsia were present during the third and fourth courses of gentamicin. These findings could be explained by cumulative injury to the vestibular apparatus caused by repeated therapeutic insults.
    Matched MeSH terms: Audiometry, Pure-Tone
  12. Gendeh BS, Said H, Gibb AG, Aziz NS, Zahir ZM
    J Laryngol Otol, 1991 Dec;105(12):999-1001.
    PMID: 1787382
    In a prospective study on 47 patients, 16 mg of gentamicin per two litres dialysate was administered intraperitoneally at every cycle of intermittent peritoneal dialysis, carried out over the course of several days. Serum gentamicin sampling, pure tone audiometry and caloric tests were performed before and during the treatment. The gentamicin levels reached at the end of the thirtieth cycle were observed to be low. In view of this, the risk of acute ototoxicity was considered to be minimal. This was confirmed by the absence of clinical audiometric or vestibulometric evidence of toxicity.
    Matched MeSH terms: Audiometry, Pure-Tone
  13. Goh BS, Tang CL, Hashim ND, Annamalay T, Abd Rahman FN
    PMID: 30578988 DOI: 10.1016/j.ijporl.2018.12.010
    OBJECTIVE: There is a dearth of studies on long term hearing status and behavioural patterns among cleft lip and/or palate children after their primary lip and palate closure in Malaysia. This study describes the audiology status and behavioural patterns in a group of school aged children with cleft lip and/or palate.

    METHOD: A cross sectional study was carried out where caretakers of cleft lip and/or palate were asked to complete the translated Malay language version of Strength Difficulties Questionnaire. The hearing status of the children was analyzed based on recent pure tone audiometric and tympanogram results. The patients' age, gender, type of cleft pathology, age of palatal surgery and behavioural patterns were examined for their potential relationship with hearing status.

    RESULTS: A total of 74 children (148 ears) aged between 7 and 17 years with cleft lip and/or palate were recruited. The result showed 37 ears (25.0%) had hearing loss with majority suffered from mild conductive hearing loss. There were 16 ears (10.8%) that had persistent middle ear effusion. Hearing improvement occurred when palatal repair was performed at the age of less than 1 year old. (p = 0.015) There was no significant relationship between patients' gender, age, type of cleft and history of myringotomy with their hearing status. In terms of behavioural patterns, 16.3% were abnormal for total behavioural score, 39.2% for peer problem and 17.6% for conduct problem. For prosocial behaviour, 16.3% were rated low and very low. There was fair correlation between age and hyperactivity problems (r = 0.44). Patients' gender, type of cleft pathology, had been teased apart and hearing status was found not related to behavioural problems.

    CONCLUSION: Cleft lip and/or palate patients have a good longterm hearing outcome. Majority had normal hearing and if there is hearing impairment, it is only a mild loss. Early palatal repair surgery before the age of 1 year can significantly reduce the risk of hearing loss. Cleft lip and/or palate patients experienced peer problems. There was no significant correlation between behavioural difficulty and hearing status among school-aged children with cleft lip and palate.

    Matched MeSH terms: Audiometry, Pure-Tone
  14. Goh LC, Azman A, Siti HBK, Khoo WV, Muthukumarasamy PA, Thong MK, et al.
    Int J Pediatr Otorhinolaryngol, 2018 Jun;109:50-53.
    PMID: 29728184 DOI: 10.1016/j.ijporl.2018.03.010
    OBJECTIVE: To study the audiological outcome and early screening of pre-school going children with craniosynostosis under follow-up at the University of Malaya Medical Center(UMMC), Kuala Lumpur, Malaysia over a 10 year period.

    METHODS: A retrospective descriptive cohort study on the audiological findings detected during the first hearing assessment done on a child with craniosynostosis using otoacoustic emissions, pure tone audiometry or auditory brainstem response examination. The main aim of this study was to evaluate the type and severity of hearing loss when compared between syndromic and non-sydromic craniosynostosis, and other associated contributory factors.

    RESULTS: A total of 31 patients with 62 ears consisting of 14 male patients and 17 female patients were evaluated. Twenty two patients (71%) were syndromic and 9 (29%) were non-syndromic craniosynostosis. Amongst the syndromic craniosynostosis, 9 (41%) had Apert syndrome, 7 (32%) had Crouzon syndrome, 5 (23%) had Pfieffer syndrome and 1 (4%) had Shaethre Chotzen syndrome. Patients with syndromic craniosynostosis were more likely to present with all types and severity of hearing loss, including severe to profound sensorineural hearing loss while children with non-syndromic craniosynostosis were likely to present with normal hearing (p 

    Matched MeSH terms: Audiometry, Pure-Tone
  15. Govindaraju R, Omar R, Rajagopalan R, Norlisah R, Kwan-Hoong N
    Auris Nasus Larynx, 2011 Aug;38(4):519-22.
    PMID: 21236610 DOI: 10.1016/j.anl.2010.12.006
    The higher field strength magnetic resonance imaging (MRI) such as 3 Tesla (T) and above generates noise that has potential detrimental effects on the hearing. Temporary threshold shifts following MRI examination have been reported for MRI with lower field strength. Such effect, however, have not been reported so far for a 3T MRI. We report a case that exemplifies the possible detrimental effects of a 3 T MRI generated noise on the auditory system. Our patient underwent investigation of his chronic backache in a 3 T MRI unit and developed hearing loss and tinnitus post-MRI examination. Hearing assessment was done using pure tone audiogram, distortion product otoacoustic emission (DPOAE) and brainstem electrical response audiometry (BERA) which revealed a unilateral sensorineural hearing loss which recovered within 3 days. However the tinnitus persisted. This is possibly a case of temporary threshold shift following noise exposure. However a sudden sensorineural hearing loss remains the other possibility.
    Matched MeSH terms: Audiometry, Pure-Tone
  16. Ho EC, Ong WMW, Li K, Zhang H, Bei YTE, Medapati SVR, et al.
    Int J Audiol, 2018 10;57(10):776-783.
    PMID: 29957077 DOI: 10.1080/14992027.2018.1476781
    OBJECTIVE: To examine the factors associated with late presentation at first hearing aid (HA) fitting, HA choice and usage among users in Singapore.

    DESIGN: Retrospective cross-sectional study.

    STUDY SAMPLE: 1068 subjects issued with HAs at a tertiary hospital from 2001 to 2013.

    RESULTS: Half of the subjects presented with more severe (>55 dB) hearing loss (HL) in their better ear. In multivariable analysis, older age, Malay ethnicity, conductive and mixed HL, and combination type of HL were associated with more severe HL at first presentation. Over 70% of subjects were older than 65 years. Worse pure tone audiometry (PTA) thresholds of the better ear, gradual onset and sensorineural HL were associated with older age presentation. For unilaterally fitted subjects, PTA thresholds were the only determinant of having the better ear aided. Better PTA thresholds, younger age and sensorineural HL were associated with choosing in ear compared to behind the ear HAs. Younger age and worse PTA of the better ear were associated with ≥4 h of daily HA usage.

    CONCLUSIONS: Age, ethnicity and type of HL were important determinants for more severe HL at first HA fitting. Older patients and those with better hearing were less likely to use their HAs regularly.

    Matched MeSH terms: Audiometry, Pure-Tone
  17. Hu S, Anschuetz L, Huth ME, Sznitman R, Blaser D, Kompis M, et al.
    JMIR Res Protoc, 2019 Jan 09;8(1):e12270.
    PMID: 30626571 DOI: 10.2196/12270
    BACKGROUND: Electroencephalography (EEG) studies indicate possible associations between tinnitus and changes in the neural activity. However, inconsistent results require further investigation to better understand such heterogeneity and inform the interpretation of previous findings.

    OBJECTIVE: This study aims to investigate the feasibility of EEG measurements as an objective indicator for the identification of tinnitus-associated neural activities.

    METHODS: To reduce heterogeneity, participants served as their own control using residual inhibition (RI) to modulate the tinnitus perception in a within-subject EEG study design with a tinnitus group. In addition, comparison with a nontinnitus control group allowed for a between-subjects comparison. We will apply RI stimulation to generate tinnitus and nontinnitus conditions in the same subject. Furthermore, high-frequency audiometry (up to 13 kHz) and tinnitometry will be performed.

    RESULTS: This work was funded by the Infrastructure Grant of the University of Bern, Bern, Switzerland and Bernafon AG, Bern, Switzerland. Enrollment for the study described in this protocol commenced in February 2018. Data analysis is currently under way and the first results are expected to be submitted for publication in 2019.

    CONCLUSIONS: This study design helps in comparing the neural activity between conditions in the same individual, thereby addressing a notable limitation of previous EEG tinnitus studies. In addition, the high-frequency assessment will help to analyze and classify tinnitus symptoms beyond the conventional clinical standard.

    INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): RR1-10.2196/12270.

    Matched MeSH terms: Audiometry, Pure-Tone
  18. Ibrahim IA, Ting HN, Moghavvemi M
    J Int Adv Otol, 2019 Apr;15(1):87-93.
    PMID: 30924771 DOI: 10.5152/iao.2019.4553
    OBJECTIVES: This study uses a new approach for classifying the human ethnicity according to the auditory brain responses (electroencephalography [EEG] signals) with a high level of accuracy. Moreover, the study presents three different algorithms used to classify the human ethnicity using auditory brain responses. The algorithms were tested on Malays and Chinese as a case study.

    MATERIALS AND METHODS: The EEG signal was used as a brain response signal, which was evoked by two auditory stimuli (Tones and Consonant Vowels stimulus). The study was carried out on Malaysians (Malay and Chinese) with normal hearing and with hearing loss. A ranking process for the subjects' EEG data and the nonlinear features was used to obtain the maximum classification accuracy.

    RESULTS: The study formulated the classification of Normal Hearing Ethnicity Index and Sensorineural Hearing Loss Ethnicity Index. These indices classified the human ethnicity according to brain auditory responses by using numerical values of response signal features. Three classification algorithms were used to verify the human ethnicity. Support Vector Machine (SVM) classified the human ethnicity with an accuracy of 90% in the cases of normal hearing and sensorineural hearing loss (SNHL); the SVM classified with an accuracy of 84%.

    CONCLUSION: The classification indices categorized or separated the human ethnicity in both hearing cases of normal hearing and SNHL with high accuracy. The SVM classifier provided a good accuracy in the classification of the auditory brain responses. The proposed indices might constitute valuable tools for the classification of the brain responses according to the human ethnicity.

    Matched MeSH terms: Audiometry, Pure-Tone/methods
  19. Ibrahimzubil, A.R., Nor Hassim, I., Thaherah Nor
    MyJurnal
    Comparative cross sectional study was conducted to determine the prevalence of hearing impairment among workers in one of the airport in Malaysia and the factors associated with it. A total of 248 subjects comprising 175 from the exposed group and the remaining control group were sampled. The main tools used in this study were validated questionnaire on hearing assessment and pure tone audiometric test. Response rate was 94%. Both area and personal exposure monitoring have exceeded action level for 8 Hrs TWA in the exposed group but within normal limit in the control group. The prevalence of hearing impairment was 88% among the noise exposed group and 11% in the control group with prevalence odds ratio (POR) 3.569 (95%CI 1.210-10.53, p
    Matched MeSH terms: Audiometry, Pure-Tone
  20. Indudharan R, Valuyeetham KA, Raju SS
    Arch Med Res, 2005 Mar-Apr;36(2):154-8.
    PMID: 15847949 DOI: 10.1016/j.arcmed.2004.12.012
    It is conventional to use antibiotic-steroid combination eardrops, although the advantage of steroid combination has not been substantiated. The present prospective randomized comparative study is designed to assess the role of glucocorticoids in ototopical antibiotic-steroid preparations in the treatment of chronic suppurative otitis media (CSOM).
    Matched MeSH terms: Audiometry, Pure-Tone
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)