  1. Pui WC, Chieng TH, Siow SL, Nik Abdullah NA, Sagap I
    Asian Pac J Cancer Prev, 2020 Oct 01;21(10):2927-2934.
    PMID: 33112550 DOI: 10.31557/APJCP.2020.21.10.2927
    BACKGROUND: Various methods have been used for treatment of hemorrhagic radiation proctitis (HRP) with variable results. Currently, the preferred treatment is formalin application or endoscopic therapy with argon plasma coagulation. Recently, a novel therapy with colonic water irrigation and oral antibiotics showed promising results and more effective compared to 4% formalin application for HRP. The study objective is to compare the effect of water irrigation and oral antibiotics versus 4% formalin application in improving per rectal bleeding due to HRP and related symptoms such as diarrhoea, tenesmus, stool frequency, stool urgency and endoscopic findings.

    METHODS: We conducted a study on 34 patients with HRP and randomly assigned the patients to two treatment arm groups (n=17). The formalin group underwent 4% formalin dab and another session 4 weeks later. The irrigation group self-administered daily rectal irrigation at home for 8 weeks and consumed oral metronidazole and ciprofloxacin during the first one week. We measured the patients' symptoms and endoscopic findings before and after total of 8 weeks of treatment in both groups.

    RESULTS: Our study showed that HRP patients had reduced per rectal bleeding (p = 0.003) in formalin group, whereas irrigation group showed reduced diarrhoea (p=0.018) and tenesmus (p=0.024) symptoms. The comparison between the two treatment arms showed that irrigation technique was better than formalin technique for tenesmus (p=0.043) symptom only.

    CONCLUSION: This novel treatment showed benefit in treating HRP. It could be a new treatment option which is safe and conveniently self-administered at home or used as a combination with other therapies to improve the treatment outcome for HRP.
    .

    Matched MeSH terms: Electrocoagulation/methods*
  2. Emami Moghaddam SA, Harun R, Mokhtar MN, Zakaria R
    Biomed Res Int, 2018;2018:6563196.
    PMID: 30643814 DOI: 10.1155/2018/6563196
    The interest in utilizing algae for wastewater treatment has been increased due to many advantages. Algae-wastewater treatment system offers a cost-efficient and environmentally friendly alternative to conventional treatment processes such as electrocoagulation and flocculation. In this biosystem, algae can assimilate nutrients in the wastewater for their growth and simultaneously capture the carbon dioxide from the atmosphere during photosynthesis resulting in a decrease in the greenhouse gaseousness. Furthermore, the algal biomass obtained from the treatment process could be further converted to produce high value-added products. However, the recovery of free suspended algae from the treated effluent is one of the most important challenges during the treatment process as the current methods such as centrifugation and filtration are faced with the high cost. Immobilization of algae is a suitable approach to overcome the harvesting issue. However, there are some drawbacks with the common immobilization carriers such as alginate and polyacrylamide related to low stability and toxicity, respectively. Hence, it is necessary to apply a new carrier without the mentioned problems. One of the carriers that can be a suitable candidate for the immobilization is zeolite. To date, various types of zeolite have been used for the immobilization of cells of bacteria and yeast. If there is any possibility to apply them for the immobilization of algae, it needs to be considered in further studies. This article reviews cell immobilization technique, biomass immobilization onto zeolites, and algal immobilization with their applications. Furthermore, the potential application of zeolite as an ideal carrier for algal immobilization has been discussed.
    Matched MeSH terms: Electrocoagulation
  3. Danial R, Sobri S, Abdullah LC, Mobarekeh MN
    Chemosphere, 2019 Oct;233:559-569.
    PMID: 31195261 DOI: 10.1016/j.chemosphere.2019.06.010
    In this study, the performance of glyphosate removal in an electrocoagulation batch with two electrodes formed by the same metal type, consisting of aluminum, iron, steel and copper have been compared. The aim of this study intends to remove glyphosate from an aqueous solution by an electrocoagulation process using metal electrode plates, which involves electrogeneration of metal cations as coagulant agents. The production of metal cations showed an ability to bind together to form aggregates of flocs composed of a combination of glyphosate and metal oxide. Electrocoagulation using aluminum electrodes indicated a high percentage removal of glyphosate, 94.25%; followed by iron electrodes, 88.37%; steel electrodes, 62.82%; and copper electrodes, 46.69%. The treated aqueous solution was then analyzed by Fourier Transform Infrared Spectroscopy. Percentages of Carbon, Hydrogen, Nitrogen, Sulfur remaining in the treated aqueous solution after the electrocoagulation process have been determined. The treated water and sludge were characterized and the mechanism of the overall process was concluded as an outcome. An X-Ray Diffraction analysis of dried sludge confirmed that new polymeric compounds were formed during the treatment. The sludge composed of new compounds were also verified the removals. This study revealed that an electrocoagulation process using metal electrodes is reliable and efficient.
    Matched MeSH terms: Electrocoagulation/methods
  4. Bani-Melhem K, Elektorowicz M, Tawalbeh M, Al Bsoul A, El Gendy A, Kamyab H, et al.
    Chemosphere, 2023 Oct;339:139693.
    PMID: 37536541 DOI: 10.1016/j.chemosphere.2023.139693
    Treating and reusing wastewater has become an essential aspect of water management worldwide. However, the increase in emerging pollutants such as polycyclic aromatic hydrocarbons (PAHs), which are presented in wastewater from various sources like industry, roads, and household waste, makes their removal difficult due to their low concentration, stability, and ability to combine with other organic substances. Therefore, treating a low load of wastewater is an attractive option. The study aimed to address membrane fouling in the submerged membrane bioreactor (SMBR) used for wastewater treatment. An aluminum electrocoagulation (EC) device was combined with SMBR as a pre-treatment to reduce fouling. The EC-SMBR process was compared with a conventional SMBR without EC, fed with real grey water. To prevent impeding biological growth, low voltage gradients were utilized in the EC deviceThe comparison was conducted over 60 days with constant transmembrane pressure and infinite solid retention time (SRT). In phase I, when the EC device was operated at a low voltage gradient (0.64 V/cm), no significant improvement in the pollutants removal was observed in terms of color, turbidity, and chemical oxygen demand (COD). Nevertheless, during phase II, a voltage gradient of 1.26 V/cm achieved up to 100%, 99.7%, 92%, 94.1%, and 96.5% removals in the EC-SMBR process in comparison with 95.1%, 95.4%, 85%, 91.7% and 74.2% removals in the SMBR process for turbidity, color, COD, ammonia nitrogen (NH3-N), total phosphorus (TP), respectively. SMBR showed better anionic surfactant (AS) removal than EC-SMBR. A voltage gradient of 0.64 V/cm in the EC unit significantly reduced fouling by 23.7%, while 1.26 V/cm showed inconsistent results. Accumulation of Al ions negatively affected membrane performance. Low voltage gradients in EC can control SMBR fouling if Al concentration is controlled. Future research should investigate EC-SMBR with constant membrane flux for large-scale applications, considering energy consumption and operating costs.
    Matched MeSH terms: Electrocoagulation
  5. Al Aradi IK
    Dermatol Surg, 2006 Oct;32(10):1244-50.
    PMID: 17034373
    Management of periorbital syringomas is problematic and avoided by many inexperienced physicians. The medical literature presently prefers CO(2) laser resurfacing to many other modalities, but the subject of electrosurgery has not been well explored.
    Matched MeSH terms: Electrocoagulation/instrumentation*
  6. Leung AK, Barankin B, Leong KF, Hon KL
    Drugs Context, 2018;7:212563.
    PMID: 30622585 DOI: 10.7573/dic.212563
    Background: Penile warts are the most common sexually transmitted disease in males. Clinicians should be familiar with the proper evaluation and management of this common condition.

    Objective: To provide an update on the current understanding, evaluation, and management of penile warts.

    Methods: A PubMed search was completed in Clinical Queries using the key terms 'penile warts' and 'genital warts'. The search strategy included meta-analyses, randomized controlled trials, clinical trials, observational studies, and reviews.

    Results: Penile warts are caused by human papillomavirus (HPV), notably HPV-6 and HPV-11. Penile warts typically present as asymptomatic papules or plaques. Lesions may be filiform, exophytic, papillomatous, verrucous, hyperkeratotic, cerebriform, fungating, or cauliflower-like. Approximately one-third of penile warts regress without treatment and the average duration prior to resolution is approximately 9 months. Active treatment is preferable to watchful observation to speed up clearance of the lesions and to assuage fears of transmission and autoinoculation. Patient-administered therapies include podofilox (0.5%) solution or gel, imiquimod 3.75 or 5% cream, and sinecatechins (polypheron E) 15% ointment. Clinician-administered therapies include podophyllin, cryotherapy, bichloroacetic or trichloroacetic acid, oral cimetidine, surgical excision, electrocautery, and carbon dioxide laser therapy. Patients who do not respond to first-line treatments may respond to other therapies or a combination of treatment modalities. Second-line therapies include topical/intralesional/intravenous cidofovir, topical 5-fluorouracil, and topical ingenol mebutate.

    Conclusion: No single treatment has been shown to be consistently superior to other treatment modalities. The choice of the treatment method should depend on the physician's comfort level with the various treatment options, the patient's preference and tolerability of treatment, and the number and severity of lesions. The comparative efficacy, ease of administration, adverse effects, cost, and availability of the treatment modality should also be taken into consideration.

    Matched MeSH terms: Electrocoagulation
  7. Aliaga Ramos J, Arantes V, Abdul Rani R, Yoshida N
    Endosc Int Open, 2020 Dec;8(12):E1741-E1747.
    PMID: 33269305 DOI: 10.1055/a-1265-6598
    Background and study aims  Submucosal (SM) injection is a critical step in endoscopic submucosal dissection (ESD). In Japan, use of viscous solutions such as sodium hyaluronate are recommended; the commercially product available is MucoUp (Seikagaku Co. and Boston Scientific Japan Co., Japan). Nevertheless, MucoUp is expensive and unavailable in many Western countries. For the past 8 years, we have been using low-cost sterile teardrops solution composed of 0.4 % sodium hyaluronate (Adaptis Fresh, Legrand Laboratory, Brazil). This solution is readily available in drugstores with a cost of approximately US$ 10.00 for each 10-cc bottle. The aim of this study was to present the clinical outcome with off-label sodium hyaluronate use for SM injection in gastric ESD. Patients and methods  A single-center retrospective study of collected data investigating consecutive patients that underwent gastric ESD between 2012 and 2019. ESD was performed using 0.4 % sodium hyaluronate teardrop for SM injection and Flush Knife BT 2.5 (Fujifilm Co., Japan). The following data were analyzed: clinical-pathological features, en-bloc, R0 and curative resection rate, procedure duration, adverse events, and clinical outcome. Results  ESD was performed with sodium hyaluronate for submucosal injection in 78 patients. The en-bloc resection rate and R0 resection rate were 96.1 % and 92.3 %, respectively. The curative resection rate for epithelial lesions was 83.8 %. Adverse events occurred in 5 cases (6.3 %): delayed bleeding (3.8 %, 3 cases) and perforation (2.5 %, 2 cases); all managed successfully by clipping and thermal coagulation. The mean volume of sodium hyaluronate solution used per patient was 10 cc (SD: ± 8 cc). During follow-up (mean: 17 months; SD: ± 14.5 months), two patients developed metachronous lesions (2.5 %). Conclusions  Off-label use of teardrops with 0.4 % sodium hyaluronate for submucosal injection was demonstrated to be safe and able to provide an effective submucosal cushion that facilitates SM dissection in gastric ESD procedures.
    Matched MeSH terms: Electrocoagulation
  8. Al-Raad AA, Hanafiah MM, Naje AS, Ajeel MA
    Environ Pollut, 2020 Oct;265(Pt B):115049.
    PMID: 32599327 DOI: 10.1016/j.envpol.2020.115049
    In this study, a novel rotating anode-based reactor (RAR) was designed to investigate its effectiveness in removing dissolved salts (i.e., Br-, Cl-, TDS, and SO42-) from saline water samples. Two configurations of an impeller's rotating anode with various operation factors, such as operating time (min), rotating speed (rpm), current density (mA/cm2), temperature (°C), pH, and inter-electrode space (cm), were used in the desalination process. The total cost consumed was calculated on the basis of the energy consumption and aluminum (Al) used in the desalination. In this respect, operating costs were calculated using optimal operating conditions. Salinity was removed electrochemically from saline water through electrocoagulation (EC). Results showed that the optimal adjustments for treating saline water were carried out at the following conditions: 150 and 75 rpm rotating speeds for the impeller's rod anode and plate anode designs, respectively; 2 mA/cm2 current density (I), 1 cm2 inter-electrode space, 25 °C temperature, 10 min operation time, and pH 8. The results indicated that EC technology with impeller plates of rotating anode can be considered a very cost-effective technique for treating saline water.
    Matched MeSH terms: Electrocoagulation
  9. Asaithambi P, Aziz ARA, Sajjadi B, Daud WMABW
    Environ Sci Pollut Res Int, 2017 Feb;24(6):5168-5178.
    PMID: 27221586 DOI: 10.1007/s11356-016-6909-5
    In the present work, the efficiency of the sonication, electrocoagulation, and sono-electrocoagulation process for removal of pollutants from the industrial effluent of the pulp and paper industry was compared. The experimental results showed that the sono-electrocoagulation process yielded higher pollutant removal percentage compared to the sonication and electrocoagulation process alone. The effect of the operating parameters in the sono-electrocoagulation process such as electrolyte concentration (1-5 g/L), current density (1-5 A/dm(2)), effluent pH (3-11), COD concentration (1500-6000 mg/L), inter-electrode distance (1-3 cm), and electrode combination (Fe and Al) on the color removal, COD removal, and power consumption were studied. The maximum color and COD removal percentages of 100 and 95 %, respectively, were obtained at the current density of 4 A/dm(2), electrolyte concentration of 4 g/L, effluent pH of 7, COD concentration of 3000 mg/L, electrode combination of Fe/Fe, inter-electrode distance of 1 cm, and reaction time of 4 h, respectively. The color and COD removal percentages were analyzed by using an UV/Vis spectrophotometer and closed reflux method. The results showed that the sono-electrocoagulation process could be used as an efficient and environmental friendly technique for complete pollutant removal.
    Matched MeSH terms: Electrocoagulation/methods*
  10. Rakhmania, Kamyab H, Yuzir MA, Al-Qaim FF, Purba LDA, Riyadi FA
    Environ Sci Pollut Res Int, 2023 Jun;30(28):71741-71753.
    PMID: 34480301 DOI: 10.1007/s11356-021-16197-z
    In this study, palm oil mill effluent (POME) was treated using electrocoagulation, whereby the influencing factors including voltage, electrolysis time, and electrolyte amount were optimized to achieve the highest chemical oxygen demand (COD) and color removal efficiencies. Graphite was selected as electrode material due to its performance better compared to aluminum and copper. Response surface methodology (RSM) was carried out for optimization of the electrocoagulation operating parameters. The best model obtained using Box-Behnken design (BBD) were quadratic for COD removal (R2 = 0.9844), color reduction (R2 = 0.9412), and oil and grease removal (R2 = 0.9724). The result from the analysis of variance (ANOVA) was obtained to determine the relationship between factors and treatment efficiencies. The experimental results under optimized conditions such as voltage 14, electrolysis time of 3 h, and electrolyte amount of 13.41 g/L show that the electrocoagulation process effectively reduced the COD (56%), color (65%), and oil and grease (99%) of the POME treatment. Graphical abstract.
    Matched MeSH terms: Electrocoagulation/methods
  11. Mousazadeh M, Niaragh EK, Usman M, Khan SU, Sandoval MA, Al-Qodah Z, et al.
    Environ Sci Pollut Res Int, 2021 Aug;28(32):43143-43172.
    PMID: 34164789 DOI: 10.1007/s11356-021-14631-w
    Electrocoagulation (EC) is one of the emerging technologies in groundwater and wastewater treatment as it combines the benefits of coagulation, sedimentation, flotation, and electrochemical oxidation processes. Extensive research efforts implementing EC technology have been executed over the last decade to treat chemical oxygen demand (COD)-rich industrial wastewaters with the aim to protect freshwater streams (e.g., rivers, lakes) from pollution. A comprehensive review of the available recent literature utilizing EC to treat wastewater with high COD levels is presented. In addition, recommendations are provided for future studies to improve the EC technology and broaden its range of application. This review paper introduces some technologies which are often adopted for industrial wastewater treatment. Then, the EC process is compared with those techniques as a treatment for COD-rich wastewater. The EC process is considered as the most privileged technology by different research groups owing to its ability to deal with abundant volumes of wastewater. After, the application of EC as a single and combined treatment for COD-rich wastewaters is thoroughly reviewed. Finally, this review attempts to highlight the potentials and limitations of EC. Related to the EC process in batch operation mode, the best operational conditions are found at 10 V and 60 min of voltage and reaction time, respectively. These last values guarantee high COD removal efficiencies of > 90%. This review also concludes that considerably large operation costs of the EC process appears to be the serious drawback and renders it as an unfeasible approach for handling of COD rich wastewaters. In the end, this review has attempted to highlights the potential and limitation of EC and suggests that vast notably research in the field of continuous flow EC system is essential to introduce this technology as a convincing wastewater technology.
    Matched MeSH terms: Electrocoagulation
  12. Kumaresan R, Karthikeyan P, Mohammed F, Thapasum Fairozekhan A
    Int J Clin Pediatr Dent, 2013 Sep;6(3):201-4.
    PMID: 25206223 DOI: 10.5005/jp-journals-10005-1219
    Mucocele, a common benign cystic lesion of minor salivary gland and associated ducts develops following extravasation or retention of mucous material in the subepithelial tissue. Occurrence of mucocele of tongue is considered less frequent when compared to a higher incidence of mucocele in the lower lip of young patients. Different modalities of treatment, such as conventional surgical excision followed by newer techniques like cryosurgery, electrocautery have been proposed to completely remove the lesion and reduce the chances of recurrence. Herewith, we report a novel treatment technique using alginate impression material to aid in complete excision of mucocele of glands of Blandin-Nuhn. How to cite this article: Kumaresan R, Karthikeyan P, Mohammed F, Fairozekhan TA. A Novel Technique for the Management of Blandin-Nuhn Mucocele: A Case Report. Int J Clin Pediatr Dent 2013;6(3):201-204.
    Matched MeSH terms: Electrocoagulation
  13. Goh LC, Wan MH, Shashi G, Elangkumaran S
    Iran J Otorhinolaryngol, 2018 Jul;30(99):225-229.
    PMID: 30083529
    Introduction: This study aims to report a rare case of a respiratory epithelial adenomatoid hamartoma (REAH) of the lateral nasal wall that had initially presented as a fungating mass, similar to that of a sinonasal malignancy, and its complete removal from the lateral nasal wall.

    Case Report: We report the case of a 58-year-old woman who presented to us with a chief complaint of recurrent right-sided epistaxis and nasal blockage for the past 4 months, which was progressively worsening. Histopathological examination confirmed the presence of a REAH instead of a sinonasal malignancy. The tumor was surgically excised from the lateral nasal wall using electrocautery under endoscopic guidance. The patient was then carefully followed-up after surgery, and the wound was successfully healed 3 months after the initial surgery. There was no evidence of recurrence 6 months after the initial surgery.

    Conclusion: This case demonstrates the rare presentation of a REAH, which had arisen from the lateral nasal wall. Clinically, it is difficult to distinguish a REAH from a more notorious mass such as a sinonasal malignancy. Therefore, biopsy is mandatory in all cases of lateral nasal mass in order to rule out malignancy before confirming nasal REAH. Fortunately, as seen in this case, a lateral nasal REAH, once diagnosed, can be safely and easily removed from the lateral nasal wall using electrocautery with good surgical outcomes and a low rate of recurrence.

    Matched MeSH terms: Electrocoagulation
  14. Naje AS, Chelliapan S, Zakaria Z, Abbas SA
    J Environ Manage, 2016 Jul 1;176:34-44.
    PMID: 27039362 DOI: 10.1016/j.jenvman.2016.03.034
    This paper investigates the optimum operational conditions of a novel rotated bed electrocoagulation (EC) reactor for the treatment of textile wastewater. The effect of various operational parameters such as rotational speed, current density (CD), operational time (RT), pH, temperature, and inter-electrode distance (IED) on the pollutant removal efficiency were examined. In addition, the consumption of aluminum (Al) and electrical energy, as well as operating costs at optimum conditions were also calculated. The results indicated that the optimum conditions for the treatment of textile wastewater were achieved at CD = 4 mA/cm(2), RT = 10 min, rotational speed = 150 rpm, pH = 4.57, temperature = 25 °C, and IED = 1 cm. The electrode consumption, energy consumption, and operating costs were 0.038 kg/m(3), 4.66 kWh/m(3) and 0.44 US$/m(3), respectively. The removal efficiencies of chemical oxygen demand (COD), biological oxygen demand (BOD), total suspended solid (TSS), turbidity and color were 97.10%, 95.55%, 98%, 96% and 98.50%, respectively, at the first 10 min of reaction time, while the phenol compound of the wastewater was almost entirely removed (99.99%). The experimental results confirm that the new reactor design with rotated anode impellers and cathode rings provided high treatment efficiency at a reduced reaction time and with lower energy consumption.
    Matched MeSH terms: Electrocoagulation
  15. Al-Raad AA, Hanafiah MM
    J Environ Manage, 2021 Dec 15;300:113696.
    PMID: 34509809 DOI: 10.1016/j.jenvman.2021.113696
    Electrocoagulation (ECoag) technique has shown considerable potential as an effective method in separating different types of pollutants (including inorganic pollutants) from various sources of water at a lower cost, and that is environmentally friendly. The EC method's performance depends on several significant parameters, including current density, reactor geometry, pH, operation time, the gap between electrodes, and agitation speed. There are some challenges related to the ECoag technique, for example, energy consumption, and electrode passivation as well as its implementation at a larger scale. This review highlights the recent studies published about ECoag capacity to remove inorganic pollutants (including salts), the emerging reactors, and the effect of reactor geometry designs. In addition, this paper highlights the integration of the ECoag technique with other advanced technologies such as microwave and ultrasonic to achieve higher removal efficiencies. This paper also presents a critical discussion of the major and minor reactions of the electrocoagulation technique with several significant operational parameters, emerging designs of the ECoag cell, operating conditions, and techno-economic analysis. Our review concluded that optimizing the operating parameters significantly enhanced the efficiency of the ECoag technique and reduced overall operating costs. Electrodes geometry has been recommended to minimize the passivation phenomenon, promote the conductivity of the cell, and reduce energy consumption. In this review, several challenges and gaps were identified, and insights for future development were discussed. We recommend that future studies investigate the effect of other emerging parameters like perforated and ball electrodes on the ECoag technique.
    Matched MeSH terms: Electrocoagulation
  16. Huda N, Raman AAA, Bello MM, Ramesh S
    J Environ Manage, 2017 Dec 15;204(Pt 1):75-81.
    PMID: 28865309 DOI: 10.1016/j.jenvman.2017.08.028
    The main problem of landfill leachate is its diverse composition comprising many persistent organic pollutants which must be removed before being discharge into the environment. This study investigated the treatment of raw landfill leachate using electrocoagulation process. An electrocoagulation system was designed with iron as both the anode and cathode. The effects of inter-electrode distance, initial pH and electrolyte concentration on colour and COD removals were investigated. All these factors were found to have significant effects on the colour removal. On the other hand, electrolyte concentration was the most significant parameter affecting the COD removal. Numerical optimization was also conducted to obtain the optimum process performance. Under optimum conditions (initial pH: 7.73, inter-electrode distance: 1.16 cm, and electrolyte concentration (NaCl): 2.00 g/L), the process could remove up to 82.7% colour and 45.1% COD. The process can be applied as a pre-treatment for raw leachates before applying other appropriate treatment technologies.
    Matched MeSH terms: Electrocoagulation/methods*
  17. Nasution MA, Yaakob Z, Ali E, Tasirin SM, Abdullah SR
    J Environ Qual, 2011 Jul-Aug;40(4):1332-9.
    PMID: 21712603 DOI: 10.2134/jeq2011.0002
    Palm oil mill effluent (POME) is highly polluting wastewater generated from the palm oil milling process. Palm oil mill effluent was used as an electrolyte without any additive or pretreatment to perform electrocoagulation (EC) using electricity (direct current) ranging from 2 to 4 volts in the presence of aluminum electrodes with a reactor volume of 20 L. The production of hydrogen gas, removal of chemical oxygen demand (COD), and turbidity as a result of electrocoagulation of POME were determined. The results show that EC can reduce the COD and turbidity of POME by 57 and 62%, respectively, in addition to the 42% hydrogen production. Hydrogen production was also helpful to remove the lighter suspended solids toward the surface. The production of Al(OH)XHO at the aluminum electrode (anode) was responsible for the flocculation-coagulation process of suspended solids followed by sedimentation under gravity. The production of hydrogen gas from POME during EC was also compared with hydrogen gas production by electrolysis of tap water at pH 4 and tap water without pH adjustment under the same conditions. The main advantage of this study is to produce hydrogen gas while treating POME with EC to reduce COD and turbidity effectively.
    Matched MeSH terms: Electrocoagulation/instrumentation; Electrocoagulation/methods*
  18. Balasubramanian N, Kojima T, Basha CA, Srinivasakannan C
    J Hazard Mater, 2009 Aug 15;167(1-3):966-9.
    PMID: 19231076 DOI: 10.1016/j.jhazmat.2009.01.081
    Removal of arsenic from aqueous solution was carried out using electrocoagulation. Experiments were conducted using mild steel sacrificial anode covering wide range in operating conditions to assess the removal efficiency. The maximum arsenic removal efficiency was recorded as 94% under optimum condition. The electrocoagulation mechanism of arsenic removal has been developed to understand the effect of applied charge and electrolyte pH on arsenic removal efficiency. Further the experimental data were tested with different adsorption isotherm model to describe the electrocoagulation process.
    Matched MeSH terms: Electrocoagulation/methods*
  19. Rajendren, S. K., Krishnan, K., Ganesh, T. N., Roslan, N. S., Hashim, N. A., Mohamad, M. A.
    Jurnal Veterinar Malaysia, 2019;31(2):19-22.
    MyJurnal
    A 5-year-old Mongrel was brought presented with the complaint of having serosanguineous discharge from penis for a month since adoption. Physical examination revealed cauliflower-like mass at the bulbus glandis. Presence of numerous anisokaryotic and anisocytotic round to oval histiocytes with multivacuolated cytoplasm from cytology, an evidence of canine transmissibale venereal tumour (CTVT). The mass was successfully surgically resected using electrocautery and was in remission for 12 months (since January 2019).
    Matched MeSH terms: Electrocoagulation
  20. Nur Syuhaidah Mohd Aris, Shariff Ibrahim, Borhannuddin Arifin, Yahaya Hawari
    MyJurnal
    Electrocoagulation has proven to be an effective method in the treatment of wastewater. This study evaluated the decolourisation of Palm Oil Mill Effluent (POME) using electrocoagulation (EC) batch reactor by utilising aluminium as sacrificial electrode. POME sample source from a final discharged pond at a palm oil mill was characterised for its colour, chemical oxygen demand (COD), pH, conductivity and turbidity; were found to be 2707 PtCo, 3909 mg/L, 7.63, 12.82 mS/cm and 755 NTU respectively. The respective effects of operating parameters such as pH (3 to 11), applied voltage (5 V to 20 V), plate gap (7.5 to 11.5 cm) and operating time (1 to 8 hours) were investigated. The decolourisation of POME was observed to increase with increasing voltage and operating time. Highest removal efficiency was observed at pH 5, 20 V applied voltage, 9.5 cm plate gap and at 8-hour operating time with colour removal efficiency of 89, 79, 78 and 64% respectively. From the findings, it can be concluded that electrocoagulation process using aluminium electrodes is a reliable technique for the removal of colour from POME.
    Matched MeSH terms: Electrocoagulation