Displaying publications 1 - 20 of 63 in total

Abstract:
Sort:
  1. Miranda AF, Reddy VG
    Med J Malaysia, 1990 Mar;45(1):65-9.
    PMID: 2152071
    A Brain laryngeal mask was assessed in fifty patients undergoing general anaesthesia who required controlled ventilation. The mask was inserted in all patients without any difficulty and the satisfactory seal obtained enabled ventilation in all patients in a wide range of positions. Airway obstruction occurred in seven patients secondary to downfolding of the epiglottis and this was rectified by reinsertion. The incidence of sore throat was 10%. The Brain laryngeal mask is a safe alternative to the tracheal tube for controlled ventilation during general anaesthesia.
    Matched MeSH terms: Masks*
  2. Reddy SV, Win N
    Singapore Med J, 1990 Aug;31(4):338-40.
    PMID: 2255930
    Brain laryngeal mask (BLM) was used to assess its suitability in 50 spontaneously breathing patients by one lecturer and 4 Medical Officers. Insertion of the laryngeal mask was successful at the first attempt in 42 patients, second attempt in 7 and third attempt in one. The incidence of airway obstruction secondary to downfolding of the epiglottis, which was corrected by reinsertion, was 16%. Post-operative complications included clenching of teeth in 5 patients, vomiting in 2 and excessive salivation in 3. The incidence of sore throat was 10%.
    Matched MeSH terms: Masks
  3. Chiu CL, Murugasu J, Chan L
    Anaesth Intensive Care, 2003 Apr;31(2):187-92.
    PMID: 12712784
    We have compared the use of the laryngeal mask airway with the new modified laryngeal tube in a prospective randomized controlled study. Sixty ASA 1 or 2 patients, aged 18 to 65 years, scheduled for elective surgery and breathing spontaneously under general anaesthesia, were studied. After preoxygenation, anaesthesia was induced with fentanyl and propofol. The patients were randomized to receive either a laryngeal mask airway or a laryngeal tube. Anaesthesia was maintained with nitrous oxide, oxygen and isoflurane. We recorded the speed and the ease of insertion, the number of attempts needed to successfully secure the airway and intraoperative complications, such as partial airway obstruction needing airway manipulation. The airway devices were removed with the patients fully awake at the end of surgery. Systolic arterial blood pressure, heart rate and end-tidal CO2 were recorded at various time intervals. Postoperative complications were recorded. We found that the incidence of partial airway obstruction needing intraoperative airway manipulation was higher with the laryngeal tube than with the laryngeal mask airway. We conclude that during spontaneous ventilation the modified laryngeal tube is not as reliable in providing a satisfactory airway and we consider it is not a suitable alternative to the laryngeal mask airway.
    Matched MeSH terms: Laryngeal Masks*
  4. Rao AS, Yew AEG, Inbasegaran K
    Med J Malaysia, 2003 Dec;58(5):717-22.
    PMID: 15190658 MyJurnal
    The summary of various studies done looking at size selection of the laryngeal mask airway (LMA) in adults is that, selection based on sex is appropriate, and that both sizes 4 or 5 are adequate for adult females. However, in our local population these sizes may be too large especially the size 5 for adult females.
    Matched MeSH terms: Laryngeal Masks/standards*
  5. Goh PK, Chiu CL, Wang CY, Chan YK, Loo PL
    Anaesth Intensive Care, 2005 Apr;33(2):223-8.
    PMID: 15960405
    The aim of this prospective, double-blind, randomized, placebo-controlled clinical trial was to investigate whether the administration of ketamine before induction with propofol improves its associated haemodynamic profile and laryngeal mask airway (LMA) insertion conditions. Ninety adult patients were randomly allocated to receive either ketamine 0.5 mg x kg(-1) (n = 30), fentanyl 1 microg x kg(-1) (n = 30) or normal saline (n = 30), before induction of anaesthesia with propofol 2.5 mg x kg(-1). Insertion of the LMA was performed 60s after injection of propofol. Arterial blood pressure and heart rate were measured before induction (baseline), immediately after induction, immediately before LMA insertion, immediately after LMA insertion and every minute for three minutes after LMA insertion. Following LMA insertion, the following six subjective endpoints were graded by a blinded anaesthestist using ordinal scales graded 1 to 3: mouth opening, gagging, swallowing, movement, laryngospasm and ease of insertion. Systolic blood pressure was significantly higher following ketamine than either fentanyl (P = 0.010) or saline (P = 0.0001). The median (interquartile range) summed score describing the overall insertion conditions were similar in the ketamine [median 7.0, interquartile range (6.0-8.0)] and fentanyl groups [median 7.0, interquartile range (6.0-8.0)]. Both appeared significantly better than the saline group [median 8.0, interquartile range (6.75-9.25); P = 0.024]. The incidence of prolonged apnoea (> 120s) was higher in the fentanyl group [23.1% (7/30)] compared with the ketamine [6.3% (2/30)] and saline groups [3.3% (1/30)]. We conclude that the addition of ketamine 0.5 mg x kg(-1) improves haemodynamics when compared to fentanyl 1 microg x kg(-1), with less prolonged apnoea, and is associated with better LMA insertion conditions than placebo (saline).
    Matched MeSH terms: Laryngeal Masks*
  6. Yong SC, Chen SJ, Boo NY
    Arch. Dis. Child. Fetal Neonatal Ed., 2005 Nov;90(6):F480-3.
    PMID: 15941825
    To compare the incidence of nasal trauma associated with the use of prong or mask during nasal continuous positive airway pressure (nCPAP) support in very low birthweight (<1501 g) infants.
    Matched MeSH terms: Masks/adverse effects*
  7. Zainuddin Z, Shaker AAH
    Family Physician, 2005;13(3):2-4.
    MyJurnal
    Thyroid diseases are common in women, including at the time of pregnancies. Many typical features of hyperthyroidism are common in normal pregnancies and this may delay or mask the diagnosis. Uncontrolled thyrotoxicosis increases the rate of miscarriage, intrauterine growth restriction (IUGR), premature labour and perinatal mortality. Multi-disciplinary efforts are required to achieve optimal control of thyrotoxicosis. Anti-thyroid drugs are safe and should be used with the lowest possible doses. Radioiodine treatment is contraindicated during pregnancy and lactation. Indications of surgery include: compression symptoms, thyroid malignancy, non-compliance to medications or when the patient develop drugs side effects
    Matched MeSH terms: Masks
  8. Jeyaindran S
    Med J Malaysia, 2006 Mar;61(1):117-21.
    PMID: 16708750
    From the beginning of time, man has lived in a continuous state of interdependence with his environment. If the forces of nature are harnessed well, they are a source of great benefit to mankind, but when this balance is tipped, nature's backlash on man can be quite devastating. In recent times, we have seen many vivid examples of the magnitude of the destructive forces of nature, ranging from massive floods caused by typhoons such as Katrina and Rita, the hundreds of thousands of lives lost by the powerful tsunami and the destruction of the environment by the raging forest fires in Spain and California. Yet man has not learnt his lesson. Often greed, at times gross ignorance and more often than not, just indifference to the effects of his actions on the environment result in man upsetting his balance with the environment. In Malaysia, since 1990, the haze has become a predictable annual occurrence, varying only in its severity and duration. The cause being beyond our control, we are unable to prevent it from happening. However, it is within our means to be ready to take the necessary steps to minimize the effects of the haze on the health of Malaysians. In order to be able to give appropriate advice and to allay the anxiety of the general public, it is necessary to have a clear understanding about the various effects of haze on humans.
    Matched MeSH terms: Masks
  9. Noor Zairul M, Khairul Faizi A, Norzalina E
    Med J Malaysia, 2006 Jun;61(2):157-61.
    PMID: 16898305
    The purpose of this study is to assess whether the newly developed laryngeal tube (LT) VBM is easy, simple to use and able to provide adequate ventilation and oxygenation to a patient with an unstable neck who required airway management. We compared the LT to the laryngeal mask airway (LMA) as alternative airway management tool in adult patient with unstable neck who underwent intubation with manual in-line neck stabilization. A randomized single-blinded prospective study was conducted involving a total of 40 ASA I and II premedicated patients who were divided into two groups with 20 patients for each group; either LT or LMA group for airway management during elective surgery. After preoxygenation, anaesthesia was induced and neuromuscular blockade was produced with intravenous drugs. The LT or LMA was inserted after neuromuscular blockade was confirmed using a peripheral nerve stimulator (TOF 1). A size 3, 4 or 5 LT OR a size 3 or 4 LMA was inserted while the patient's head and neck were being stabilized by an assistant who held the sides of the neck and the mastoid processes (manual in-line stabilization). If it was not possible to ventilate the lungs, or if endotrachial carbon dioxide (ETCO2) and/or chest movement did not indicate a patent airway, the LT or LMA was removed. After three failed attempts, the study was terminated and the airway was secured in the most suitable manner determined by the anaesthetist. There was a statistically significant difference for both groups in the time required for successful insertion (time required for LT was 24.8 +/- 7.7 seconds and LMA was 36.1+/-17.3 seconds) (p= 0.01). There was no statistical differences (p>0.05) in number of attempts needed to achieve a patent airway although we were able to achieve a clear airway in all patients in LT group at the first attempt compared with 85% in LMA group. successful insertion rate was 100% for both groups. We conclude that the LT is easier to insert and is a suitable alternative to the LMA for airway management when the patient's head and neck are stabilized by manual in-line method.
    Matched MeSH terms: Laryngeal Masks*
  10. Noor Zairul M, Khairul Faizi A
    Singapore Med J, 2006 Oct;47(10):892-6.
    PMID: 16990966
    INTRODUCTION: The purpose of this study is to assess whether the newly-developed VBM (Medizintechnik GmbH, Sulz, Germany) laryngeal tube (LT) is able to provide adequate ventilation and oxygenation to patients with an unstable neck and require airway management. The haemodynamic responses to insertion between the two devices were also studied. We compared the LT to the laryngeal mask airway (LMA) as an alternative airway management tool in adult patients with unstable neck and who underwent intubation with manual in-line neck stabilisation.
    METHODS: A randomised single-blinded prospective study was conducted involving a total of 40 American Society of Anesthesiology I and II pre-medicated patients who were divided into two groups, LT or LMA, for airway management during elective surgery. There were 20 patients for each group. After pre-oxygenation, anaesthesia was induced using intravenous (i.v.) fentanyl and i.v. propofol. The neuromuscular blockade was produced with either i.v. vecuronium or i.v. atracurium. The LT or LMA was inserted after neuromuscular blockade was confirmed using a peripheral nerve stimulator (train-of-four 1). A size 3, 4 or 5 LT or a size 3 or 4 LMA was inserted while the patient's head and neck were being stabilised by an assistant who held the sides of the neck and the mastoid processes (manual in-line stabilisation). If it was not possible to ventilate the lungs, or if end-tidal carbon dioxide and/or chest movement did not indicate a patent airway, the LT or LMA was removed. After three failed attempts, the study was terminated and the airway was secured in the most suitable manner determined by the anaesthetist. After successful placement of LT or LMA, anaesthesia was maintained with 66 percent nitrous oxide in oxygen and 2 minimum alveolar concentration sevoflurane. All patients received standard anaesthesia monitoring. The ease of insertion, the number of attempts needed to successfully secure the airway, episodes of desaturation (less than 95 percent) and end-tidal carbon dioxide at various time intervals were studied. The haemodynamic parameters such as systolic blood pressure, diastolic blood pressure, mean arterial pressure and heart rate at different time intervals were also studied.
    RESULTS: The study showed a statistically significant difference in time required for successful insertion between the groups; time required for LT was 24.8 +/- 7.7 seconds and LMA was 36.1 +/- 17.3 seconds (p-value equals 0.01). Both groups had no statistical differences (p-value is greater than 0.05) in number of attempts needed to achieve a patent airway, and the successful insertion rate was 100 percent for both groups. There were also no statistical differences in the haemodynamic response to insertion and the end-tidal carbon dioxide in this study.
    CONCLUSION: We conclude that, under anaesthesia, the LT was a valuable and better alternative to LMA for ventilation and airway management when the patient's head and neck are stabilised by the manual in-line method.
    Matched MeSH terms: Laryngeal Masks*
  11. Liew SM
    Malays Fam Physician, 2006;1(2):91-93.
    PMID: 27570598 MyJurnal
    Recommend that the following measures be applied universally: CPR training should emphasize the very low risk of disease transmission. Training in the use of barrier mask should be included; Oral barrier devices should be made freely available in hospital and in public areas e.g. hotels, theaters, health clubs and restaurants. A survey among health personnel in Malaysia conducted in 2005 found that nearly half of the 4989 subjects were either not confident at all or unsure about their ability in giving first-aid and CPR.13 The investigators however did not look at fear of infection in particular.
    Matched MeSH terms: Masks
  12. Noorddin Y, Raha AR, Jaafar MZ, Rozaidi SH, Muraly S, Marlizan MY
    Med J Malaysia, 2007 Jun;62(2):127-9.
    PMID: 18705444 MyJurnal
    The use of laryngeal mask airway (LMA) as an alternative to the endotracheal tube (ETT) is becoming more popular in the practice of anesthesia. It is undeniable that this device has numerous advantages over endotracheal tube, however it does not provide an airtight seal between the airway and atmospheric gases. This may lead to pollution of the operating room environment with nitrous oxide. One hundreds adult patients undergoing general anaesthesia were divided into two groups. The airway in Group I was maintained with LMA with spontaneous ventilation and ETT with intermittent positive pressure ventilation (IPPV) was used for Group II. The result demonstrated that the ETT group recorded concentrations of nitrous oxide that were well above the NIOSH recommended eight hour time weighted average of 25ppm throughout the duration of surgery when compared to patients using LMA.
    Matched MeSH terms: Laryngeal Masks*
  13. Shariffuddin II, Wang CY
    Anaesthesia, 2008 Jan;63(1):82-5.
    PMID: 18086075
    We compared the performance of the Ambu AuraOnce Laryngeal Mask with that of the LMA Classic laryngeal mask airway during controlled anaesthesia. Forty patients requiring intermittent positive pressure ventilation were studied using a randomised crossover design. The mean (SD) oropharyngeal leak pressure for the Ambu device (19 (7.5) cmH2O) was significantly greater than for the LMA Classic (15 (5.2) cmH2O; p = 0.004), and the number of attempts for successful insertions was significantly less (39 (50%) vs 45 (56%), respectively; p = 0.02). There was one failure to obtain a patent airway with the Ambu Laryngeal Mask and none with the LMA Classic. Insertion of the Ambu Laryngeal Mask required more manipulations to achieve a patent airway than did the LMA Classic (6 (15%) vs 1 (2.5%), respectively; p = 0.045), but the time taken for insertion was similar between the two groups. The incidence of trauma, grade of fibreoptic view, peak airway pressure and quality of ventilation during maintenance of anaesthesia were similar in both groups.
    Matched MeSH terms: Laryngeal Masks*
  14. Teoh CY, Lim FS
    Paediatr Anaesth, 2008 Feb;18(2):119-24.
    PMID: 18184242 DOI: 10.1111/j.1460-9592.2007.02385.x
    The Proseal laryngeal mask airway (PLMA) is a relatively new supraglottic airway device with a drain tube to minimize the risk of gastric insufflation and aspiration. We compared introducer tool (IT) and gum elastic bougie (GEB)-guided techniques for insertion of the Proseal LMA in children.
    Matched MeSH terms: Laryngeal Masks/adverse effects*
  15. Yahya, N.A., Lim, K.H.D.
    Ann Dent, 2008;15(2):89-93.
    MyJurnal
    Direct composite veneers can be used to mask tooth discolorations and/or to correct unaesthetic tooth forms and/or positions. However, these type of restorations are often regarded as one of the most challenging in aesthetic dentistry presumably due to the extent of natural tooth structure that must be recreated. This paper discusses easy application techniques and tips for Ceram.X Duo™, a nano ceramic composite restorative material. Its natural shading system allows the restoration of tooth with both dentine and enamel shade and transforms it into a final direct veneer restoration that mimics a natural tooth.
    Matched MeSH terms: Masks
  16. Hutagalung SD, Darsono T, Khatijah A. Yaacob
    Atomic force microscopes (AFM) as one of the scanning probe microscopy (spm) modes have become useful tools, not only for observing surface morphology and nanostructure topography but also for fabrication of various nanostructures itself. In this work, silicon oxide (SiOx) patterns were formed on Si(100) surface by means of AFM anodization, where a non-contact mode used to oxidize Si wafer at the nanoscale size. The oxide patterns could serve as masks for the chemical etching of Si surface in alkaline solution in order to create the Si nanodots. A special attention is paid to finding relations between the size of dots and operational parameters as tip bias voltage and tip writing speed Dot arrays with 10 nm high and less than 50 nm in diameter have been successfully fabricated. The ability to control oxidation and scanning speed can be utilized in fabrication of complex nanostructures and make scanning probe lithography (SPL) as a very promising lithographic technique in nanoelectronic devices, nanophotonics and other high-tech areas.
    Matched MeSH terms: Masks
  17. Cheah PK, Ahmed R, Ho CV, Lim CC
    Malays Fam Physician, 2009;4(2-3):91-3.
    PMID: 25606171 MyJurnal
    Nasal foreign body in children is not an uncommon presentation to the Emergency Department. Removal is essential. Many methods of removal exist. Nasal wash technique is advocated mainly in friable foreign bodies. We report the successful use of the oral bag-valve-mask insufflation technique to remove friable facial tissue in the left nose of a 2 year-old girl. We used a pediatric bag-valve-mask with a pop-off pressure relief valve to avoid barotrauma. Pop-off pressure relief valve limits the pressure beyond 30mmHg. Conscious sedation was not required. There were no complications.
    Matched MeSH terms: Masks
  18. Tan AS, Wang CY
    Anaesth Intensive Care, 2010 Jan;38(1):65-9.
    PMID: 20191779
    The aim of this randomised, controlled trial was to determine the optimum dose of fentanyl in combination with propofol 2.5 mg x kg(-1) when inserting the Classic Laryngeal Mask Airway. Seventy-five ASA I or II patients were randomly assigned to five groups of fentanyl dosage: 0 microg x kg(-1) (placebo), 0.5 microg x kg(-1), 1.0 microg x kg(-1), 1.5 microg x kg(-1) and 2.0 microg x kg(-1). Anaesthesia was induced by first injecting the study drug over 10 seconds. Three minutes after the study drug was injected, propofol (2.5 mg x kg(-1)) was injected over 10 seconds. The Classic Laryngeal Mask Airway was inserted four minutes and 30 seconds after injection of the study drug. Insertion conditions were evaluated using a four-category score. Thirty-nine males and 36 females aged 19 to 59 years were studied. The incidence of prolonged apnoea increased as fentanyl dose increased. We found that there was a high rate of successful first attempt at insertion with 1 microg x kg(-1) and 1.5 microg x kg(-1), 93% and 87% respectively, compared to 87% in the 2.0 microg x kg(-1) group. The 1.0 microg x kg(-1) group also achieved an 80% optimal insertion conditions score of 4, compared to 73% in the 1.5 microg x kg(-1) group and 80% in the 2 microg x kg(-1) group. Therefore we recommend 1.0 microg x kg(-1) as the optimal dose of fentanyl when used in addition to propofol 2.5 mg/kg for the insertion of the Classic Laryngeal Mask Airway.
    Matched MeSH terms: Laryngeal Masks*
  19. Chew EE, Hashim NH, Wang CY
    Anaesth Intensive Care, 2010 Nov;38(6):1018-22.
    PMID: 21226431
    We compared the performance of the LMA Supreme (SLMA) with the I-Gel during anaesthesia in spontaneously breathing adult patients. Ninety patients with American Society of Anesthesiologists physical status I or II were studied in a prospective randomised controlled study. Our primary outcome measure was oropharyngeal leak pressure. We also compared the overall insertion success rate, ease of insertion, adequacy of ventilation and incidence of complications. The mean (SD), oropharyngeal leak pressure for the SLMA was 25.6 (5.1) cmH2O, which was greater than for the I-Gel 20.7 (5.9) cmH2O (P = 0.0001). The first attempt and overall insertion success rates were similar between the two groups (SLMA 97.8 and 97.8%; I-Gel 93.3 and 100%, P = 0.132). The SLMA was rated easier to insert than the I-Gel (P = 0.011), but the time taken for insertion (P = 0.433) was similar. The incidence of complications was low in both groups. The grade of fibreoptic view was better with the I-Gel than the SLMA (P = 0.001). We conclude that in adults with normal airways, the SLMA is easier to insert and provides a higher oropharyngeal leak pressure, but fibreoptic views are better with the i-gel.
    Matched MeSH terms: Laryngeal Masks*
  20. Hui MT, Subash S, Wang CY
    Anaesthesia, 2011 Apr;66(4):274-7.
    PMID: 21401540 DOI: 10.1111/j.1365-2044.2011.06620.x
    The 50% and 95% effective doses of desflurane for removal of the classic laryngeal mask airway after suction of the upper airway, in anaesthetised spontaneously breathing adult patients, are not known. To determine these, we studied 38 healthy patients, aged between 18 and 44 years. The target desflurane concentration in each individual patient was determined by the Dixon up-and-down method. When the predetermined target end-tidal desflurane concentration reached steady state, we kept a constant end-expiratory partial pressure between the alveolus and the brain for 10 min before attempting to remove the classic laryngeal mask airway after suctioning the upper airway. The initial desflurane target concentration was set at 6% and up-down desflurane increments were 0.1%. This continued until there were at least six crossover pairs. From the probit analysis, the 50% effective dose of desflurane was 5.29% (95% CI 5.132-5.379%) and the 95% effective dose was 5.55% (95% CI 5.429-6.394%).
    Matched MeSH terms: Laryngeal Masks*