Displaying publications 1 - 20 of 30 in total

Abstract:
Sort:
  1. Zainal Abidin I, Syed Tamin S, Huat Tan L, Chong WP, Azman W
    Pacing Clin Electrophysiol, 2007 Nov;30(11):1420-2.
    PMID: 17976112
    Infection is a relatively rare but devastating complication of intracardiac device implantation. Burkholderia pseudomallei is the organism which causes melioidosis, an endemic and lethal infection in the tropics. We describe a case of pacemaker infection secondary to Burkholderia pseudomallei, which was treated by explantation of the device and appropriate antimicrobial therapy.
    Matched MeSH terms: Pacemaker, Artificial/adverse effects*
  2. Yew KL
    Heart Views, 2014 Apr;15(2):49-50.
    PMID: 25104983 DOI: 10.4103/1995-705X.137497
    Electrical or electrocution injury is a common accidental occurrence and mostly workplace related. Fatal arrhythmias, skin injury and sudden death may ensue. However, it is rare for electrocution to result in permanent low rate sinus bradycardia, incompatible with an active lifestyle. The probable mechanisms for this pathological sinus bradycardia are sinus node dysfunction and autonomic dysfunction with vagal predominance. We describe a young patient who suffered a non fatal electrocution with resultant low rate sinus bradycardia and its successful treatment with a dual chamber rate responsive pacemaker.
    Matched MeSH terms: Pacemaker, Artificial
  3. Yew KL, Anderson S, Farah R, Lim SH
    Asian Cardiovasc Thorac Ann, 2014 Oct;22(8):979-80.
    PMID: 24887840 DOI: 10.1177/0218492313491583
    Central vein stenosis is not uncommon in hemodialysis-dependent patients as a result of mechanical damage to the vessel walls from prior cannulation. It can cause ipsilateral upper limb swelling and pain, resulting in suboptimal hemodialysis. It is unfortunate for bilateral central vein stenosis to develop concomitantly, and rare in the setting of an in-situ pacemaker. This case illustrates the successful ligation of a nondependent left arteriovenous fistula and stenting of the right subclavian vein with functioning ipsilateral arteriovenous fistula, to overcome the problem of symptomatic bilateral upper limb swelling.
    Matched MeSH terms: Pacemaker, Artificial/adverse effects*
  4. Yew KL
    Med J Malaysia, 2012 Dec;67(6):618-9.
    PMID: 23770958 MyJurnal
    We are seeing more implantation of cardiac device such as pacemakers and defibrillators and also cardiac implantable electronic device infection. The infection may affect just the pocket site or progress to deeper infection and bacteraemia. Inadequately treated infection may lead to right sided endocarditis, cardiotomy for pacemaker explantation and increased cost and length of stay in the hospital. We report a Staphylococcal infection of a pacemaker system, its successful medical and surgical management.
    Matched MeSH terms: Pacemaker, Artificial
  5. Wong TS, Abu Bakar J, Chee KH, Hasan MS, Chung WH, Chiu CK, et al.
    Spine (Phila Pa 1976), 2019 02 15;44(4):E252-E257.
    PMID: 30086081 DOI: 10.1097/BRS.0000000000002828
    STUDY DESIGN: Case report.

    OBJECTIVE: To describe the technical difficulties on performing posterior spinal fusion (PSF) on a pacemaker-dependent patient with complete congenital heart block and right thoracic scoliosis.

    SUMMARY OF BACKGROUND DATA: Congenital complete heart block requires pacemaker implantation at birth through thoracotomy, which can result in scoliosis. Corrective surgery in this patient was challenging. Height gain after corrective surgery may potentially cause lead dislodgement. The usage of monopolar electrocautery may interfere with the function of the implanted cardiac device.

    METHODS: A 17-year-old boy was referred to our institution for the treatment of right thoracic scoliosis of 70°. He had underlying complete congenital heart block secondary to maternal systemic lupus erythematosus. Pacemaker was implanted through thoracotomy since birth and later changed for four times. PSF was performed by two attending surgeons with a temporary pacing inserted before the surgery. The monopolar electrocautery device was used throughout the surgery.

    RESULTS: The PSF was successfully performed without any technical issues and complications. Postoperatively, his permanent pacemaker was functioning normally. Three days later, he was recovering well and was discharged home from hospital.

    CONCLUSION: This case indicates that PSF can be performed successfully with thoughtful anticipation of technical difficulties on a pacemaker-dependent patient with underlying congenital heart block.

    LEVEL OF EVIDENCE: 5.

    Matched MeSH terms: Pacemaker, Artificial
  6. Tamin SS, Hussin A, Za I, Halmey N, Azman W
    Pacing Clin Electrophysiol, 2007 Feb;30(2):276-9.
    PMID: 17338728
    Coronary sinus perforation is a relatively uncommon but much feared complication that may occur during the placement of left ventricular pacing lead. Coronary sinus perforation, especially in the presence of an obstructive flap, usually indicates the need to abandon the implantation attempt, as there are difficulties in crossing the obstructive flap as well as uncertainty of whether the lead is in the true lumen or into the pericardial space. We describe our experience in successfully placing the left ventricular lead safely despite the problems arising from these circumstances.
    Matched MeSH terms: Pacemaker, Artificial/adverse effects*
  7. Steinwender C, Khelae SK, Garweg C, Chan JYS, Ritter P, Johansen JB, et al.
    JACC Clin Electrophysiol, 2020 01;6(1):94-106.
    PMID: 31709982 DOI: 10.1016/j.jacep.2019.10.017
    OBJECTIVES: This study reports on the performance of a leadless ventricular pacemaker with automated, enhanced accelerometer-based algorithms that provide atrioventricular (AV) synchronous pacing.

    BACKGROUND: Despite many advantages, leadless pacemakers are currently only capable of single-chamber ventricular pacing.

    METHODS: The prospective MARVEL 2 (Micra Atrial tRacking using a Ventricular accELerometer 2) study assessed the performance of an automated, enhanced accelerometer-based algorithm downloaded to the Micra leadless pacemaker for up to 5 h in patients with AV block. The primary efficacy objective was to demonstrate the superiority of the algorithm to provide AV synchronous (VDD) pacing versus VVI-50 pacing in patients with sinus rhythm and complete AV block. The primary safety objective was to demonstrate that the algorithm did not result in pauses or heart rates of >100 beats/min.

    RESULTS: Overall, 75 patients from 12 centers were enrolled; an accelerometer-based algorithm was downloaded to their leadless pacemakers. Among the 40 patients with sinus rhythm and complete AV block included in the primary efficacy objective analysis, the proportion of patients with ≥70% AV synchrony at rest was significantly greater with VDD pacing than with VVI pacing (95% vs. 0%; p 

    Matched MeSH terms: Pacemaker, Artificial*
  8. Siew KSW, Tan MP, Hilmi IN, Loch A
    BMC Cardiovasc Disord, 2019 08 07;19(1):191.
    PMID: 31391000 DOI: 10.1186/s12872-019-1174-4
    BACKGROUND: Swallow or deglutition syncope is an unusual type of neurally-mediated syncope associated with life-threatening bradyarrhythmia and hypotension. It is a difficult condition to diagnose with commonly delayed diagnosis and management. There is lack of review articles that elucidate the basic demographics, clinical characteristics and management of this rare condition. This publication systematically reviews the 101 case reports published since 1793 on swallow syncope.

    CASE PRESENTATION: A 59-year-old man presented with the complaint of recurrent dizziness associated with meals. A 24-h ambulatory ECG recording confirmed an episode of p-wave asystole at the time of food intake. Oesophagogastroduodenoscopy with balloon inflation in the mid to lower oesophagus resulted in a 5.6 s sinus pause. The patient's symptoms resolved completely following insertion of a permanent dual chamber pacemaker.

    CONCLUSIONS: Swallow syncope is extremely rare, but still needs to be considered during diagnostic workup. It is commonly associated with gastro-intestinal disease. Permanent pacemaker implantation is the first line treatment.

    Matched MeSH terms: Pacemaker, Artificial
  9. Saw HS, Chong KT, Singham AM
    Ann Acad Med Singap, 1981 Oct;10(4 Suppl):93-8.
    PMID: 7344608
    Updated data on permanent cardiac pacing in Malaysia is presented. Over the past 3 1/2 years (1976-1980), 75 patients underwent insertion of pacemakers giving an annual incidence of about 20 cases as compared with a total of 21 cases in the previous 8 years (1968-1977). Many of the features reported in an earlier paper in 1977 viz mode of presentation, age and sex distribution and indications for pacing remain unchanged. Over this period only 4 patients required lead replacement. Since concentrating mainly on the use of epicardial leads implanted via a subxiphoid approach, complications have been remarkably low. The problem of availability of pacemakers has been averted. Cost remains a major consideration when recommending one pacemaker in preference over another. The details concerning clinical features, indications for pacing, complications and other problems encountered in the management of these patients are discussed.
    Matched MeSH terms: Pacemaker, Artificial*
  10. Saw HS
    Family Practitioner, 1978;3(4):27-30.
    Matched MeSH terms: Pacemaker, Artificial*
  11. Sadiq MA, Azman W, Abidin IZ
    J Invasive Cardiol, 2012 Jan;24(1):E13-5.
    PMID: 22210591
    Permanent complete heart block (CHB) secondary to the loss of first septal perforator after percutaneous coronary intervention (PCI) of the left descending artery (LAD) is an extremely rare complication. We describe a case report where a patient underwent PCI of proximal LAD, complicated by loss of first septal perforator, septal infarction, and bifasicular block, which progressed to symptomatic delayed CHB. One week later, the patient required implantation of a permanent pacemaker following failure to wean off the transvenous temporary pacing maker.
    Matched MeSH terms: Pacemaker, Artificial
  12. Ritter P, Duray GZ, Steinwender C, Soejima K, Omar R, Mont L, et al.
    Eur Heart J, 2015 Oct 1;36(37):2510-9.
    PMID: 26045305 DOI: 10.1093/eurheartj/ehv214
    Permanent cardiac pacing is the only effective treatment for symptomatic bradycardia, but complications associated with conventional transvenous pacing systems are commonly related to the pacing lead and pocket. We describe the early performance of a novel self-contained miniaturized pacemaker.
    Matched MeSH terms: Pacemaker, Artificial
  13. Rai V, Shariffuddin II, Chan YK, Muniandy RK, Wong KK, Singh S
    BMC Anesthesiol, 2014;14:49.
    PMID: 25002831 DOI: 10.1186/1471-2253-14-49
    BACKGROUND: Complete heart block in pregnancy has serious implications particularly during the period of delivery. This is more so if the delivery is an operative one as the presence of heart block may produce haemodynamic instability in the intra operative period. We report a unique case of a pregnant mother with complete heart block undergoing hysterostomy, complicated by placenta accreta and intrauterine death.

    CASE PRESENTATION: A 37 year old Malaysian Chinese parturient was admitted at 25 weeks gestation following a scan which suggested intrauterine death and placenta accreta. She was diagnosed to have congenital complete heart block after her first delivery eight years previously but a pacemaker was never inserted. These medical conditions make her extremely likely to experience massive bleeding and haemodynamic instability. Among the measures taken to optimise her pre-operatively were the insertion of a temporary intravenous pacemaker and embolization of the uterine arteries to minimize peri-operative blood loss. She successfully underwent surgery under general anesthesia, which was relatively uneventful and was discharged well on the fourth post-operative day.

    CONCLUSION: Congenital heart block in pregnancies in the presence of potential massive bleeding is best managed by a team, with meticulous pre-operative optimization. Suggested strategies would include insertion of a temporary pacemaker and embolization of the uterine arteries to reduce the risk of the patient getting into life threatening situations.

    Matched MeSH terms: Pacemaker, Artificial
  14. Piccini JP, Stromberg K, Jackson KP, Laager V, Duray GZ, El-Chami M, et al.
    Heart Rhythm, 2017 05;14(5):685-691.
    PMID: 28111349 DOI: 10.1016/j.hrthm.2017.01.026
    BACKGROUND: Device repositioning during Micra leadless pacemaker implantation may be required to achieve optimal pacing thresholds.

    OBJECTIVE: The purpose of this study was to describe the natural history of acute elevated Micra vs traditional transvenous lead thresholds.

    METHODS: Micra study VVI patients with threshold data (at 0.24 ms) at implant (n = 711) were compared with Capture study patients with de novo transvenous leads at 0.4 ms (n = 538). In both cohorts, high thresholds were defined as >1.0 V and very high as >1.5 V. Change in pacing threshold (0-6 months) with high (1.0 to ≤1.5 V) or very high (>1.5 V) thresholds were compared using the Wilcoxon signed-rank test.

    RESULTS: Of the 711 Micra patients, 83 (11.7%) had an implant threshold of >1.0 V at 0.24 ms. Of the 538 Capture patients, 50 (9.3%) had an implant threshold of >1.0 V at 0.40 ms. There were no significant differences in patient characteristics between those with and without an implant threshold of >1.0 V, with the exception of left ventricular ejection fraction in the Capture cohort (high vs low thresholds, 53% vs 58%; P = .011). Patients with an implant threshold of >1.0 V decreased significantly (P < .001) in both cohorts. Micra patients with high and very high thresholds decreased significantly (P < .01) by 1 month, with 87% and 85% having 6-month thresholds lower than the implant value. However, when the capture threshold at implant was >2 V, only 18.2% had a threshold of ≤1 V at 6 months and 45.5% had a capture threshold of >2 V.

    CONCLUSIONS: Pacing thresholds in most Micra patients with elevated thresholds decrease after implant. Micra device repositioning may not be necessary if the pacing threshold is ≤2 V.

    Matched MeSH terms: Pacemaker, Artificial*
  15. Piccini JP, Stromberg K, Jackson KP, Kowal RC, Duray GZ, El-Chami MF, et al.
    Europace, 2019 Nov 01;21(11):1686-1693.
    PMID: 31681964 DOI: 10.1093/europace/euz230
    AIMS: Patient selection is a key component of securing optimal patient outcomes with leadless pacing. We sought to describe and compare patient characteristics and outcomes of Micra patients with and without a primary pacing indication associated with atrial fibrillation (AF) in the Micra IDE trial.

    METHODS AND RESULTS: The primary outcome (risk of cardiac failure, pacemaker syndrome, or syncope related to the Micra system or procedure) was compared between successfully implanted patients from the Micra IDE trial with a primary pacing indication associated with AF or history of AF (AF group) and those without (non-AF group). Among 720 patients successfully implanted with Micra, 228 (31.7%) were in the non-AF group. Reasons for selecting VVI pacing in non-AF patients included an expectation for infrequent pacing (66.2%) and advanced age (27.2%). More patients in the non-AF group had a condition that precluded the use of a transvenous pacemaker (9.6% vs. 4.7%, P = 0.013). Atrial fibrillation patients programmed to VVI received significantly more ventricular pacing compared to non-AF patients (median 67.8% vs. 12.6%; P 

    Matched MeSH terms: Pacemaker, Artificial*
  16. Ota N, Suzuki R, Latiff HA, Sivalingam S
    Ann Thorac Surg, 2015 Oct;100(4):1471.
    PMID: 26434454 DOI: 10.1016/j.athoracsur.2015.06.084
    Matched MeSH terms: Pacemaker, Artificial/adverse effects*
  17. Nor Hidayah ZA, Azerin O, Mohd Nazri A
    Med J Malaysia, 2018 10;73(5):323-325.
    PMID: 30350813 MyJurnal
    Acute Rheumatic fever (ARF) is commonly associated with ECG abnormalities particularly atrioventricular block. However, third degree atrioventricular block or complete heart block is a rare manifestation. Most cases occurred in children. We reported a 25 year old man who developed complete heart block during an acute episode of ARF. He presented to hospital with five days history of fever, malaise and migrating arthralgia, followed by pleuritic chest pain. One day after admission his electrocardiogram (ECG) revealed complete heart block. Transthoracic echocardiography showed good left ventricular function with thickened, mild mitral regurgitation with minimal pericardial effusion. ASOT titer was positive with elevated white blood count and acute phase reactant. A temporary pacemaker was inserted in view of symptomatic bradycardia. The complete heart block resolved after medical therapy. He was successfully treated with penicillin, steroid and aspirin. He was discharged well with oral penicillin. The rarity of this presentation is highlighted.
    Matched MeSH terms: Pacemaker, Artificial
  18. Lloyd M, Reynolds D, Sheldon T, Stromberg K, Hudnall JH, Demmer WM, et al.
    Heart Rhythm, 2017 02;14(2):200-205.
    PMID: 27871854 DOI: 10.1016/j.hrthm.2016.11.016
    BACKGROUND: The Micra transcatheter pacemaker was designed to have similar functionality to conventional transvenous VVIR pacing systems. It provides rate adaptive pacing using a programmable 3-axis accelerometer designed to detect patient activity in the presence of cardiac motion.

    OBJECTIVE: The purpose of this study was to evaluate the system's performance during treadmill tests to maximum exertion in a subset of patients within the Micra Transcatheter Pacing Study.

    METHODS: Patients underwent treadmill testing at 3 or 6 months postimplant with algorithm programming at physician discretion. Normalized sensor rate (SenR) relative to the programmed upper sensor rate was modeled as a function of normalized workload in metabolic equivalents (METS) relative to maximum METS achieved during the test. A normalized METS and SenR were determined at the end of each 1-minute treadmill stage. The proportionality of SenR to workload was evaluated by comparing the slope from this relationship to the prospectively defined tolerance margin (0.65-1.35).

    RESULTS: A total of 69 treadmill tests were attempted by 42 patients at 3 and 6 months postimplant. Thirty tests from 20 patients who completed ≥4 stages with an average slope of 0.86 (90% confidence interval 0.77-0.96) confirmed proportionality to workload. On an individual test basis, 25 of 30 point estimates (83.3%) had a normalized slope within the defined tolerance range (range 0.46-1.08).

    CONCLUSION: Accelerometer-based rate adaptive pacing was proportional to workload, thus confirming rate adaptive pacing commensurate to workload is achievable with an entirely intracardiac pacing system.

    Matched MeSH terms: Pacemaker, Artificial*
  19. Khoo CS
    Perm J, 2018;22:18-081.
    PMID: 30227913 DOI: 10.7812/TPP/18-081
    Matched MeSH terms: Pacemaker, Artificial*
  20. Garweg C, Khelae SK, Chan JYS, Chinitz L, Ritter P, Johansen JB, et al.
    J Cardiovasc Electrophysiol, 2021 07;32(7):1947-1957.
    PMID: 33928713 DOI: 10.1111/jce.15061
    INTRODUCTION: MARVEL 2 assessed the efficacy of mechanical atrial sensing by a ventricular leadless pacemaker, enabling a VDD pacing mode. The behavior of the enhanced MARVEL 2 algorithm during variable atrio-ventricular conduction (AVC) and/or arrhythmias has not been characterized and is the focus of this study.

    METHODS: Of the 75 patients enrolled in the MARVEL 2 study, 73 had a rhythm assessment and were included in the analysis. The enhanced MARVEL 2 algorithm included a mode-switching algorithm that automatically switches between VDD and ventricular only antibradycardia pacing (VVI)-40 depending upon AVC status.

    RESULTS: Forty-two patients (58%) had persistent third degree AV block (AVB), 18 (25%) had 1:1 AVC, 5 (7%) had variable AVC status, and 8 (11%) had atrial arrhythmias. Among the 42 patients with persistent third degree AVB, the median ventricular pacing (VP) percentage was 99.9% compared to 0.2% among those with 1:1 AVC. As AVC status changed, the algorithm switched to VDD when the ventricular rate dropped less than 40 bpm. During atrial fibrillation (AF) with ventricular response greater than 40 bpm, VVI-40 mode was maintained. No pauses longer than 1500 ms were observed. Frequent ventricular premature beats reduced the percentage of AV synchrony. During AF, the atrial signal was of low amplitude and there was infrequent sensing.

    CONCLUSION: The mode switching algorithm reduced VP in patients with 1:1 AVC and appropriately switched to VDD during AV block. No pacing safety issues were observed during arrhythmias.

    Matched MeSH terms: Pacemaker, Artificial*