Displaying publications 1 - 20 of 117 in total

Abstract:
Sort:
  1. Leong SS, Wong JHD, Md Shah MN, Vijayananthan A, Jalalonmuhali M, Mohd Sharif NH, et al.
    Ultrasound Med Biol, 2020 01;46(1):34-45.
    PMID: 31594681 DOI: 10.1016/j.ultrasmedbio.2019.08.011
    Tissue elasticity is related to the pathologic state of kidneys and can be measured using shear wave elastography (SWE). However, SWE quantification has not been rigorously validated. The aim of this study was to evaluate the accuracy of SWE-measured stiffness and the effect of tissue anisotropy on SWE measurements. Point SWE (pSWE), 2-D SWE and dynamic mechanical analysis (DMA) were used to measure stiffness and evaluate the effect of tissue anisotropy on the measurements. SWE and DMA were performed on phantoms of different gelatin concentrations. In the tissue anisotropy study, SWE and DMA were performed on the outer cortex of sheep kidneys. In the in vivo study, 15 patients with different levels of interstitial fibrosis were recruited for pSWE measurements. Another 10 healthy volunteers were recruited for tissue anisotropy studies. SWE imaging revealed a non-linear increase with gelatin concentration. There was a significant correlation between pSWE and 2-D SWE, leading to the establishment of a linear regression equation between the two SWE ultrasound measurements. In the anisotropy study, the median difference in stiffness between shear waves oriented at 0° and 90° towards the pyramid axis was significant. In the in vivo study, there was a strong positive linear correlation between pSWE and the percentage of interstitial fibrosis. There was a significant difference in the Young's modulus (YM) between severities of fibrosis. The mean YM values were lower in control patients than in patients with mild, moderate and severe fibrosis. YM values were also significantly higher when shear waves were oriented at 0° toward the pyramid axis. Tissue stiffness and anisotropy affects SWE measurements. These factors should be recognized before applying SWE for the interpretation of measured values.
    Matched MeSH terms: Phantoms, Imaging
  2. Dabbagh A, Abdullah BJ, Ramasindarum C, Abu Kasim NH
    Ultrason Imaging, 2014 Oct;36(4):291-316.
    PMID: 24626566 DOI: 10.1177/0161734614526372
    Tissue-mimicking phantoms that are currently available for routine biomedical applications may not be suitable for high-temperature experiments or calibration of thermal modalities. Therefore, design and fabrication of customized thermal phantoms with tailored properties are necessary for thermal therapy studies. A multitude of thermal phantoms have been developed in liquid, solid, and gel forms to simulate biological tissues in thermal therapy experiments. This article is an attempt to outline the various materials and techniques used to prepare thermal phantoms in the gel state. The relevant thermal, electrical, acoustic, and optical properties of these phantoms are presented in detail and the benefits and shortcomings of each type are discussed. This review could assist the researchers in the selection of appropriate phantom recipes for their in vitro study of thermal modalities and highlight the limitations of current phantom recipes that remain to be addressed in further studies.
    Matched MeSH terms: Phantoms, Imaging*
  3. Kanaga KC, Yap HH, Laila SE, Sulaiman T, Zaharah M, Shantini AA
    Med J Malaysia, 2010 Jun;65(2):119-22.
    PMID: 23756795 MyJurnal
    Full field digital mammography (FFDM) has been progressively introduced in medical centers in recent years. However, it is questionable which exposure parameters are suitable in order to reduce the glandular breast doses as they are related to induced carcinogenesis. The goal of this study was to compare the average glandular doses (AGD) and image quality of three FFDM systems namely Siemens Mammomat NovationDR, Hologic Lorad Selenia and General Electric Senographe Essential using a Figure of Merit. A Computerized Imaging Reference Systems (CIRS) tissue equivalent breast phantom which consists of phototimer compensation plate with different thickness and glandularity was exposed in fully automatic exposure control mode in the cranio-caudal projection similar to clinical settings. Thermoluminescent dosimeter 100H (TLD- 100H) was used to measure the entrance surface air kerma (ESAK), the AGD was calculated using European protocol whilst the image quality was assessed quantitatively by measuring the contrast to noise ratio (CNR) value. The obtained values were used to calculate the Figure of Merit (FOM) to analyze the effectiveness of the system. Repeated Measures ANOVA analysis showed that there is a significant difference (p<0.05) in the mean value of AGD and CNR between the three FFDM systems. Hologic Lorad Selenia system contrbuted the highest AGD value while General Electric Senographe Essential had the highest CNR and FOM value. In conclusion, this study may provide an objective criterion during the selection of a mammography unit by using the figure of merit for screening or diagnostic purpose.
    Matched MeSH terms: Phantoms, Imaging
  4. Darmini, Prastanti AD, Daryati S, Kartikasari Y, Sulistiyadi AH, Setiawan DA
    Med J Malaysia, 2023 Dec;78(7):865-869.
    PMID: 38159919
    INTRODUCTION: There are two data acquisition methods for computed tomography (CT) scans, namely sequence and helical. Each of them has two ways of measuring the volume of bleeding in a head CT scan, namely by manual and automatic methods. So, it is necessary to have an analysis for measurement accuracy with these two methods in two data acquisitions. The purpose of this study was to compare and evaluate bleeding volumetric measurement accuracy of sequence and helical on head CT acquisition using manual and automatic methods.

    MATERIALS AND METHODS: This is quantitative research with a true experimental approach. Actual bleeding volume was simulated by an acrylic phantom containing Iodine contrast media (5 ml, 10 ml, 15 ml, and 20 ml). The phantom was scanned using routine CT protocol using the helical and sequence technique. Bleeding volume from each technique was measured manually using the Broderick formula and automatic software (ROI based). Accuracy was assessed by comparing the volume measurement result to the actual bleeding volume. Data was analysed using the Friedman test and by Wilcoxon.

    RESULTS: The standard deviation of measured bleeding volume from the manual and automatic measurements compared to the actual bleeding volume were (0.220; 0.236; 0.351; 0.057) and (0.139; 0.270; 0.315; 0.329) in helical technique, and (0.333; 0.376; 0.447; 0.476) and (0.139; 0.242; 0.288; 0,376) in sequence technique. There are differences in the measurement results from the helical and sequence techniques (p <0.05) and using manual and automatic methods (p <0.05).

    CONCLUSION: The measurement of bleeding volume that has a standard deviation value compared to the actual volume is more accurate in the helical technique using the automatic method, while the sequence technique is the manual method.

    Matched MeSH terms: Phantoms, Imaging
  5. Dolah MT, Samat SB, Kadni T
    Malays J Med Sci, 2000 Jan;7(1):47-53.
    PMID: 22844215
    Absorbed dose to water was measured with ionisation chambers NE 2561 (#267), NE 2581 (#334), NE 2571 (#1028), using the IAEA standard water phantom. The ionisation chamber was inserted in the water phantom at a reference depth dependent on the type of the radiation quality used. Three radiation qualities were used namely 1.25 MeV gamma ray, 6 MV x-rays and 10 MV x-rays. The values of the absorbed dose to water were determined by the N(K)- and N(X)- based methods, i.e with the use of IAEA, HPA, NACP, AAPM, NCRP and ICRU protocols. The aim of this study was to make an intercomparison of the results, by taking the IAEA protocol as a standard. The largest deviation contributed by any of these protocols was recorded for each quality. It was found that AAPM, NCRP and ICRU protocols contributed 0.94% for 1.25 MeV gamma ray, NACP contributed 2.12% for the 6 MV x-rays, and NACP contributed 2.35% for 10 MV x-rays. Since the acceptable limit of deviation set by the IAEA for this absorbed dose work is ± 3%, it is clear that the overall deviations obtained were all satisfactory.
    Matched MeSH terms: Phantoms, Imaging
  6. Omar H, Ahmad AL, Hayashi N, Idris Z, Abdullah JM
    Malays J Med Sci, 2015 Dec;22(Spec Issue):20-8.
    PMID: 27006634 MyJurnal
    Magnetoencephalography (MEG) has been extensively used to measure small-scale neuronal brain activity. Although it is widely acknowledged as a sensitive tool for deciphering brain activity and source localisation, the accuracy of the MEG system must be critically evaluated. Typically, on-site calibration with the provided phantom (Local phantom) is used. However, this method is still questionable due to the uncertainty that may originate from the phantom itself. Ideally, the validation of MEG data measurements would require cross-site comparability.
    Matched MeSH terms: Phantoms, Imaging
  7. Jafari SM, Jordan TJ, Distefano G, Bradley DA, Spyrou NM, Nisbet A, et al.
    Br J Radiol, 2015;88(1055):20140804.
    PMID: 26258442 DOI: 10.1259/bjr.20140804
    To investigate the feasibility of using glass beads as novel thermoluminescent dosemeters (TLDs) for radiotherapy treatment plan verification.
    Matched MeSH terms: Phantoms, Imaging
  8. Banjade DP, Ng BS, Zakir M, Tajuddin AA, Shukri A
    Br J Radiol, 2002 Oct;75(898):812-8.
    PMID: 12381690
    A study of dose mapping techniques to investigate the dose distribution throughout a planned target volume (PTV) in a humanoid breast phantom exposed to a 6 MV photon beam similar to that of treatment conditions is described. For tangential breast irradiation using a 6 MV accelerator beam, the dose is mapped at various locations within the PTV using thermoluminescent dosemeters (TLDs) and radiographic films. An average size perspex breast phantom with the ability to hold the dosemeters was made. TLDs were exposed after packing them in various locations in a particular slice, as planned by the treatment planning system (TPS). To map the dose relative to the isocenter, films were exposed after tightly packing them in between phantom slices, parallel to the central axis of the beam. The dose received at every location was compared with the given dose as generated by the TPS. The mapped dose in each location in the isocentric slice from superficial to deep region was found to be in close agreement with the TPS generated dose to within +/-2%. Doses at greater depths and distant medial and lateral ends, however, were found to be lower by as much as 9.4% at some points. The mapped dose towards the superior region and closest inferior region from the isocenter was found to agree with those for TPS. Conversely, results for the farthest inferior region were found to be significantly different with a variance as much as 17.4% at some points, which is believed to be owing to the variation in size and shape of the contour. Results obtained from films confirmed this, showing similar trends in dose mapping. Considering the importance of accurate doses in radiotherapy, evaluating dose distribution using this technique and tool was found to be useful. This provides the opportunity to choose a technique and plan to provide optimum dose delivery for radiotherapy to the breast.
    Matched MeSH terms: Phantoms, Imaging*
  9. Ng AH, Alqahtani MS, Jambi LK, Bugby SL, Lees JE, Perkins AC
    Br J Radiol, 2019 Jun;92(1098):20190020.
    PMID: 30864832 DOI: 10.1259/bjr.20190020
    OBJECTIVE: To examine the imaging capability of a novel small field of view hybrid gamma camera (HGC) using 125I seeds prior to surgical use.

    METHODS: The imaging performance of the camera system was assessed quantitatively and qualitatively at different source depths, source to collimator distances (SCD), activity levels, acquisition times and source separations, utilising bespoke phantoms.

    RESULTS: The system sensitivity and spatial resolution of the HGC for 125I were 0.41 cps/MBq (at SCD 48 mm) and 1.53 ± 0.23 mm (at SCD 10 mm) respectively. The camera was able to detect the 125I seed at a SCD of 63 mm (with no scattering material in place) in images recorded within a 1-min acquisition time. The detection of the seeds beneath scattering material (simulating deep-seated tumours) was limited to depths of less than 20 mm beneath the skin surface with a SCD of 63 mm and seed activity of 2.43 MBq. Subjective assessments of the hybrid images acquired showed the capability of the HGC for localising the 125I seeds.

    CONCLUSION: This preliminary ex vivo study demonstrates that the HGC is capable of detecting 125I seeds and could be a useful tool in radioactive seed localisation with the added benefit of providing hybrid optical γ images for guiding breast conserving surgery.

    ADVANCES IN KNOWLEDGE: The SFOV HGC could provide high resolution fused optical-gamma images of 125I radioactive seeds indicating the potential use in intraoperative surgical procedure such as RSL.

    Matched MeSH terms: Phantoms, Imaging
  10. Islam MT, Samsuzzaman M, Islam MT, Kibria S
    Sensors (Basel), 2018 Dec 14;18(12).
    PMID: 30558191 DOI: 10.3390/s18124427
    An experimental system for early screening of a breast tumor is presented in this article. The proposed microwave imaging (MI) system consists of a moveable array of nine improved negative-index metamaterial (MTM)-loaded ultrawideband (UWB) antenna sensor with incorporation of a corresponding SRR (split-ring resonator) and CLS (capacitively loaded strip) structure, in a circular array, the stepper motor-based array-mounting stand, the adjustable phantom hanging platform, an RF switching system to control the receivers, and a personal computer-based signal processing and image reconstruction unit using MATLAB. The improved antenna comprises of four-unit cells along one axis, where an individual unit cell integrates a balancing SRR and CLS pair, which makes the antenna radiation omnidirectional over the operating frequencies. The electrical dimensions of this proposed antenna are 0.28λ × 0.20λ × 0.016λ, measured at the lowest operating frequency of 2.97 GHz as the operating bandwidth of this is in between 2.97⁻15 GHz (134.82% bandwidth), with stable directional radiation pattern. SP8T 8 port switch is used to enable the eight receiver antennas to sequentially send a 3⁻8.0 GHz microwave signal to capture the backscattered signal by MATLAB software. A low-cost realistic homogeneous breast phantom with tumor material is developed and measured to test the capability of the imaging system to detect the breast tumors. A post-processing delay-multiply-and-sum (DMAS) algorithm is used to process the recorded backscatter signal to get an image of the breast phantom, and to accurately identify the existence and located area of multiple breast tumor tissues.
    Matched MeSH terms: Phantoms, Imaging*
  11. Ikram S, Shah JA, Zubair S, Qureshi IM, Bilal M
    Sensors (Basel), 2019 Apr 23;19(8).
    PMID: 31018597 DOI: 10.3390/s19081918
    The application of compressed sensing (CS) to biomedical imaging is sensational since it permits a rationally accurate reconstruction of images by exploiting the image sparsity. The quality of CS reconstruction methods largely depends on the use of various sparsifying transforms, such as wavelets, curvelets or total variation (TV), to recover MR images. As per recently developed mathematical concepts of CS, the biomedical images with sparse representation can be recovered from randomly undersampled data, provided that an appropriate nonlinear recovery method is used. Due to high under-sampling, the reconstructed images have noise like artifacts because of aliasing. Reconstruction of images from CS involves two steps, one for dictionary learning and the other for sparse coding. In this novel framework, we choose Simultaneous code word optimization (SimCO) patch-based dictionary learning that updates the atoms simultaneously, whereas Focal underdetermined system solver (FOCUSS) is used for sparse representation because of a soft constraint on sparsity of an image. Combining SimCO and FOCUSS, we propose a new scheme called SiFo. Our proposed alternating reconstruction scheme learns the dictionary, uses it to eliminate aliasing and noise in one stage, and afterwards restores and fills in the k-space data in the second stage. Experiments were performed using different sampling schemes with noisy and noiseless cases of both phantom and real brain images. Based on various performance parameters, it has been shown that our designed technique outperforms the conventional techniques, like K-SVD with OMP, used in dictionary learning based MRI (DLMRI) reconstruction.
    Matched MeSH terms: Phantoms, Imaging
  12. Islam MT, Ullah MA, Alam T, Singh MJ, Cho M
    Sensors (Basel), 2018 Sep 05;18(9).
    PMID: 30189632 DOI: 10.3390/s18092949
    Microwave imaging is the technique to identify hidden objects from structures using electromagnetic waves that can be applied in medical diagnosis. The change of dielectric property can be detected using microwave antenna sensor, which can lead to localization of abnormality in the human body. This paper presents a stacked type modified Planar Inverted F Antenna (PIFA) as microwave imaging sensor. Design and performance analysis of the sensor antenna along with computational and experimental analysis to identify concealed object has been investigated in this study. The dimension of the modified PIFA radiating patch is 40 × 20 × 10 mm³. The reflector walls used, are 45 mm in length and 0.2-mm-thick inexpensive copper sheet is considered for the simulation and fabrication which addresses the problems of high expenses in conventional patch antenna. The proposed antenna sensor operates at 1.55⁻1.68 GHz where the maximum realized gain is 4.5 dB with consistent unidirectional radiation characteristics. The proposed sensor antenna is used to identify tumor in a computational human tissue phantom based on reflection and transmission coefficient. Finally, an experiment has been performed to verify the antenna's potentiality of detecting abnormality in realistic breast phantom.
    Matched MeSH terms: Phantoms, Imaging
  13. Islam MT, Samsuzzaman M, Islam MT, Kibria S, Singh MJ
    Sensors (Basel), 2018 Sep 05;18(9).
    PMID: 30189684 DOI: 10.3390/s18092962
    Microwave breast imaging has been reported as having the most potential to become an alternative or additional tool to the existing X-ray mammography technique for detecting breast tumors. Microwave antenna sensor performance plays a significant role in microwave imaging system applications because the image quality is mostly affected by the microwave antenna sensor array properties like the number of antenna sensors in the array and the size of the antenna sensors. In this paper, a new system for successful early detection of a breast tumor using a balanced slotted antipodal Vivaldi Antenna (BSAVA) sensor is presented. The designed antenna sensor has an overall dimension of 0.401λ × 0.401λ × 0.016λ at the first resonant frequency and operates between 3.01 to 11 GHz under 10 dB. The radiating fins are modified by etching three slots on both fins which increases the operating bandwidth, directionality of radiation pattern, gain and efficiency. The antenna sensor performance of both the frequency domain and time domain scenarios and high-fidelity factor with NFD is also investigated. The antenna sensor can send and receive short electromagnetic pulses in the near field with low loss, little distortion and highly directionality. A realistic homogenous breast phantom is fabricated, and a breast phantom measurement system is developed where a two antennas sensor is placed on the breast model rotated by a mechanical scanner. The tumor response was investigated by analyzing the backscattering signals and successful image construction proves that the proposed microwave antenna sensor can be a suitable candidate for a high-resolution microwave breast imaging system.
    Matched MeSH terms: Phantoms, Imaging
  14. Asan NB, Hassan E, Shah JVSRM, Noreland D, Blokhuis TJ, Wadbro E, et al.
    Sensors (Basel), 2018 Aug 21;18(9).
    PMID: 30134629 DOI: 10.3390/s18092752
    In this paper, we investigate the use of fat tissue as a communication channel between in-body, implanted devices at R-band frequencies (1.7⁻2.6 GHz). The proposed fat channel is based on an anatomical model of the human body. We propose a novel probe that is optimized to efficiently radiate the R-band frequencies into the fat tissue. We use our probe to evaluate the path loss of the fat channel by studying the channel transmission coefficient over the R-band frequencies. We conduct extensive simulation studies and validate our results by experimentation on phantom and ex-vivo porcine tissue, with good agreement between simulations and experiments. We demonstrate a performance comparison between the fat channel and similar waveguide structures. Our characterization of the fat channel reveals propagation path loss of ∼0.7 dB and ∼1.9 dB per cm for phantom and ex-vivo porcine tissue, respectively. These results demonstrate that fat tissue can be used as a communication channel for high data rate intra-body networks.
    Matched MeSH terms: Phantoms, Imaging
  15. Ullah MA, Islam MT, Alam T, Ashraf FB
    Sensors (Basel), 2018 Dec 01;18(12).
    PMID: 30513719 DOI: 10.3390/s18124214
    This paper demonstrates the performance of a potential design of a paper substrate-based flexible antenna for intrabody telemedicine systems in the 2.4 GHz industrial, scientific, and medical radio (ISM) bands. The antenna was fabricated using 0.54 mm thick flexible photo paper and 0.03 mm copper strips as radiating elements. Design and performance analyses of the antenna were performed using Computer Simulation Technology (CST) Microwave Studio software. The antenna performances were investigated based on the reflection coefficient in normal and bent conditions. The total dimensions of the proposed antenna are 40 × 35 × 0.6 mm³. The antenna operates at 2.33⁻2.53 GHz in the normal condition. More than an 8% fractional bandwidth is expressed by the antenna. Computational analysis was performed at different flexible curvatures by bending the antenna. The minimum fractional bandwidth deviation is 5.04% and the maximum is 24.97%. Moreover, it was mounted on a homogeneous phantom muscle and a four-layer human tissue phantom. Up to a 70% radiation efficiency with a 2 dB gain was achieved by the antenna. Finally, the performance of the antenna with a homogeneous phantom muscle was measured and found reliable for wearable telemedicine applications.
    Matched MeSH terms: Phantoms, Imaging
  16. Islam MT, Mahmud MZ, Islam MT, Kibria S, Samsuzzaman M
    Sci Rep, 2019 10 29;9(1):15491.
    PMID: 31664056 DOI: 10.1038/s41598-019-51620-z
    Globally, breast cancer is a major reason for female mortality. Due to the limitations of current clinical imaging, the researchers are encouraged to explore alternative and complementary tools to available techniques to detect the breast tumor in an earlier stage. This article outlines a new, portable, and low-cost microwave imaging (MWI) system using an iterative enhancing technique for breast imaging. A compact side slotted tapered slot antenna is designed for microwave imaging. The radiating fins of tapered slot antenna are modified by etching nine rectangular side slots. The irregular slots on the radiating fins enhance the electrical length as well as produce strong directive radiation due to the suppression of induced surface currents that radiate vertically at the outer edges of the radiating arms with end-fire direction. It has remarkable effects on efficiency and gain. With the addition of slots, the side-lobe levels are reduced, the gain of the main-lobe is increased and corrects the squint effects simultaneously, thus improving the characteristics of the radiation. For experimental validation, a heterogeneous breast phantom was developed that contains dielectric properties identical to real breast tissues with the inclusion of tumors. An alternative PC controlled and microcontroller-based mechanical MWI system is designed and developed to collect the antenna scattering signal. The radiated backscattered signals from the targeted area of the human body are analyzed to reveal the changes in dielectric properties in tissues. The dielectric constants of tumorous cells are higher than that of normal tissues due to their higher water content. The remarkable deviation of the scattered field is processed by using newly proposed Iteratively Corrected Delay and Sum (IC-DAS) algorithm and the reconstruction of the image of the phantom interior is done. The developed UWB (Ultra-Wideband) antenna based MWI has been able to perform the detection of tumorous cells in breast phantom that can pave the way to saving lives.
    Matched MeSH terms: Phantoms, Imaging
  17. Islam MS, Islam MT, Almutairi AF
    Sci Rep, 2021 11 10;11(1):22015.
    PMID: 34759284 DOI: 10.1038/s41598-021-01486-x
    This paper presents the preparation and measurement of tissue-mimicking head phantom and its validation with the iteratively corrected coherence factor delay-multiply-and-sum (IC-CF-DMAS) algorithm for brain stroke detection. The phantom elements are fabricated by using different chemical mixtures that imitate the electrical properties of real head tissues (CSF, dura, gray matter, white matter, and blood/stroke) over the frequency band of 1-4 GHz. The electrical properties are measured using the open-ended dielectric coaxial probe connected to a vector network analyzer. Individual phantom elements are placed step by step in a three-dimensional skull. The IC-CF-DMAS image reconstruction algorithm is later applied to the phantom to evaluate the effectiveness of detecting stroke. The phantom elements are preserved and measured multiple times in a week to validate the overall performance over time. The electrical properties of the developed phantom emulate the similar properties of real head tissue. Moreover, the system can also effectively detect the stroke from the developed phantom. The experimental results demonstrate that the developed tissue-mimicking head phantom is time-stable, and it shows a good agreement with the theoretical results in detecting and reconstructing the stroke images that could be used in investigating as a supplement to the real head tissue.
    Matched MeSH terms: Phantoms, Imaging*
  18. Karim MKA, Sabarudin A, Muhammad NA, Ng KH
    Radiol Phys Technol, 2019 Dec;12(4):374-381.
    PMID: 31468370 DOI: 10.1007/s12194-019-00532-8
    This study aimed to evaluate effective dose and size-specific dose estimate (SSDE) of computed tomography angiography (CTA) examination using an anthropomorphic phantom. We included three CTA examination protocols to evaluate the intra- and extra-cranial arteries, pulmonary artery (CTPA), and abdominal vessels. Patient SSDEs were measured retrospectively to estimate patient dose, relative to the bodyweight of the patient and volume CT dose index (CTDIvol). Our findings revealed that the highest dose was absorbed by the left lobe of the thyroid gland during intra-/extra-cranial CTA and CTPA, that is, 14.11 ± 0.24 mGy and 16.20 ± 3.95 mGy, respectively. However, the highest absorbed dose in abdominal/pelvic CTA was the gonads (8.98 ± 0.30 mGy), while other radiosensitive organs in intra- and extra-cranial CTA, CTPA, and abdominal/pelvic CTA did not demonstrate significant differences between organs/structures with p value 0.88, 0.11, and 0.54, respectively. The estimated effective dose in intra-/extra-cranial CTA was lower in patients (0.80 ± 0.60 mSv) than in the phantom (0.83 mSv), but it was the opposite for CTPA, with the effective dose being higher in patients (7.54 ± 3.09 mSv) than in the phantom (6.68 mSv). Similar to the effective dose, only CTPA SSDEs were significantly higher in men than in women (19.74 ± 4.79 mGy versus 7.9 mGy). Effective dose and SSDE are clinically relevant parameters that can help estimate a more accurate patient dose based on a patient's size.
    Matched MeSH terms: Phantoms, Imaging*
  19. Yusof MFM, Hamid PNKA, Tajuddin AA, Hashim R, Bauk S, Isa NM, et al.
    Radiol Phys Technol, 2017 Sep;10(3):331-339.
    PMID: 28718054 DOI: 10.1007/s12194-017-0408-3
    The aim of this study was to determine the suitability of tannin-added Rhizophora spp. particleboards as phantom materials in the application of low- and high-energy photons. The tannin-added Rhizophora spp. particleboards and density plug phantoms were created with a target density of 1.0 g/cm3. The elemental composition and effective atomic number of the particleboards were measured using energy dispersive X-ray analysis. The mass attenuation coefficient of the particleboards for low-energy photons were measured using the attenuation of X-ray fluorescence. The mass attenuation coefficients of high-energy photons were measured using the attenuation of 137Cs and 60Co gamma energies. The results were compared to the calculated value of water using XCOM calculations. The results showed that the effective atomic number and mass attenuation coefficients of tannin-added Rhizophora spp. particleboards were similar to those of water, indicating the suitability of tannin-added Rhizophora spp. particleboards as phantom materials for low- and high-energy photons.
    Matched MeSH terms: Phantoms, Imaging*
  20. Rabba JA, Suhaimi FM, Mat Jafri MZ, Jaafar HA, Osman ND
    Radiography (Lond), 2023 May;29(3):533-538.
    PMID: 36913788 DOI: 10.1016/j.radi.2023.02.028
    INTRODUCTION: The daily image quality assessment involves large datasets that consume a lot of time and effort. This study aims to evaluate a proposed automated calculator for image distortion analysis in 2-dimensional (2D) panoramic imaging mode for a dental cone beam computed tomography (CBCT) system in comparison with present manual calculations.

    METHODS: A ball phantom was scanned using panoramic mode of the Planmeca ProMax 3D Mid CBCT unit (Planmeca, Helsinki, Finland) with standard exposure settings used in clinical practice (60 kV, 2 mA, and maximum FOV). An automated calculator algorithm was developed in MATLAB platform. Two parameters associated with panoramic image distortion such as balls diameter and distance between middle and tenth balls were measured. These automated measurements were compared with manual measurement using the Planmeca Romexis and ImageJ software.

    RESULTS: The findings showed smaller deviation in distance difference measurements by proposed automated calculator (ranged 3.83 mm) as compared to manual measurements (ranged 5.00 for Romexis and 5.12 mm for ImageJ software). There was a significant difference (p 

    Matched MeSH terms: Phantoms, Imaging