Displaying publications 1 - 20 of 63 in total

Abstract:
Sort:
  1. Johari NH, Osman K, Helmi NH, Abdul Kadir MA
    PMID: 23521065 DOI: 10.1080/10255842.2013.776548
    Efforts to model the human upper respiratory system have undergone many phases. Geometrical proximity to the realistic shape has been the subject of many research projects. In this study, three different geometries of the trachea and main bronchus were modelled, which were reconstructed from computed tomography (CT) scan images. The geometrical variations were named realistic, simplified and oversimplified. Realistic refers to the lifelike image taken from digital imaging and communications in medicine format CT scan images, simplified refers to the reconstructed image based on natural images without realistic details pertaining to the rough surfaces, and oversimplified describes the straight wall geometry of the airway. The characteristics of steady state flows with different flow rates were investigated, simulating three varied physical activities and passing through each model. The results agree with previous studies where simplified models are sufficient for providing comparable results for airflow in human airways. This work further suggests that, under most exercise conditions, the idealised oversimplified model is not favourable for simulating either airflow regimes or airflow with particle depositions. However, in terms of immediate analysis for the prediction of abnormalities of various dimensions of human airways, the oversimplified techniques may be used.
    Matched MeSH terms: Pulmonary Ventilation
  2. Rosli Abu Bakar, Ahmad Rasdan Ismail, Norfadzilah Jusoh, Abdul Mutalib Leman
    MyJurnal
    This paper discuss thermal comfort studies of an under air conditioning in hot and humid climate which at one of the higher institution in East Coast of Malaysia. Indoor thermal environment is important as it affects the health and productivity of building occupants. The paper reports on an experimental investigation of indoor thermal comfort characteristics under the control of air conditioning. Firstly, the well known Fanger’s thermal comfort model was simplified for the current experimental investigation. This is followed by reporting the experimental results of indoor thermal comfort characteristics under the control of temperature, with eight different of temperatures which are 22oC to 29oC. Finally, indoor thermal comfort was merely affected by the increment ventilation and outdoor climate. PMV value was higher when near from the window because of the effects of the wall radiations and the metabolic heat.
    Matched MeSH terms: Ventilation
  3. Mohd Esa NY, Faisal M, Vengadesa Pilla S, Abdul Rahaman JA
    BMJ Case Rep, 2020 Dec 22;13(12).
    PMID: 33370965 DOI: 10.1136/bcr-2020-236414
    Tracheal tear after endotracheal intubation is extremely rare. The role of silicone Y-stent in the management of tracheal injury has been documented in the previous studies. However, none of the studies have mentioned the deployment of silicone Y-stent via rigid bronchoscope with the patient solely supported by extracorporeal membrane oxygenation (ECMO) without general anaesthesia delivered via the side port of the rigid bronchoscope. We report a patient who had a tracheal tear due to endotracheal tube migration following a routine video-assisted thoracoscopic surgery sympathectomy, which was successfully managed with silicone Y-stent insertion. Procedure was done while she was undergoing ECMO; hence, no ventilator connection to the side port of the rigid scope was required. This was our first experience in performing Y-stent insertion fully under ECMO, and the patient had a successful recovery.
    Matched MeSH terms: One-Lung Ventilation/instrumentation
  4. Ooi SS, Mak JW, Chen DK, Ambu S
    Ind Health, 2017 Feb 07;55(1):35-45.
    PMID: 27476379 DOI: 10.2486/indhealth.2015-0218
    The free-living protozoan Acanthamoeba is an opportunistic pathogen that is ubiquitous in our environment. However, its role in affecting indoor air quality and ill-health of indoor occupants is relatively unknown. The present study investigated the presence of Acanthamoeba from the ventilation system and its correlation with other indoor air quality parameters, used in the industry code of practice and its potential as an indicator for indoor air quality. Indoor air quality assessments were carried out in nine commercial buildings with approval from the building management, and the parameters assessed were as recommended by the Department of Occupational Safety and Health. The presence of Acanthamoeba was determined through dust swabs from the ventilation system and indoor furniture. Logistic regression was performed to study the correlation between assessed parameters and occupants' complaints. A total of 107 sampling points were assessed and 40.2% of the supplying air diffuser and blowing fan and 15% of the furniture were positive for cysts. There was a significant correlation between Acanthamoeba detected from the ventilation system with ambient total fungus count (r=0.327; p=0.01) and respirable particulates (r=0.276; p=0.01). Occupants' sick building syndrome experience also correlated with the presence of Acanthamoeba in the ventilation system (r=0.361; p=0.01) and those detected on the furniture (r=0.290; p=0.01). Logistic regression showed that there was a five-fold probability of sick building syndrome among occupants when Acanthamoeba was detected in the ventilation system.
    Matched MeSH terms: Ventilation*
  5. Nik Mohd Syukra Nik Abd Ghani, Nik Adilah Nik Othman, Amran Mohamad
    MyJurnal
    Tinnitus is not a disease per se but it is a symptom. It can be either subjective or objective type and the
    underlying cause varies such as tumour, infection, vascular abnormality or Meniere’s disease. Foreign body in the external ear is a common presentation especially in children. However, foreign body in the middle ear manifested with only symptom of tinnitus is a rare and unexpected presentation. Foreign body in the middle ear are commonly due to iatrogenic cause such as complication of myringotomy and ventilation tube insertion surgery. There are reported cases of complications of myringotomy and ventilation tube insertion, and they typically presented with the ear infection manifestation, myringosclerosis or permanent perforation of tympanic membrane. Currently, there are only few reported cases in literatures of foreign body in the middle ear following complication of medial migration of ventilation tube into a middle ear with intact tympanic membrane.
    Matched MeSH terms: Middle Ear Ventilation
  6. Azrina, M.R., Basri, M.N., Abdul Hadi, M., Fahmi, M.L., Asmarawati, M.Y., Ariff, O.
    MyJurnal
    High frequency oscillating ventilation (HFOV) provides a rescue therapy for patients with refractory hypoxaemia in severe acute respiratory distress syndrome (ARDS). HFOV utilizes high mean airway pressures to maintain an open lung and low tidal volumes at a high frequency that allows for adequate ventilation while at the same time preventing alveolar overdistension. This seems to be an ideal lung protective ventilation strategies to prevent ventilator-induced lung injury (VILI)2. We reported a case of severe extrapulmonary ARDS secondary to acute lymphoblastic leukaemia responding to the use of HFOV.
    Matched MeSH terms: High-Frequency Ventilation
  7. Mohan V, Paungmali A, Sitilertpisan P, Henry LJ, Omar FA, Azhar FZ
    J Bodyw Mov Ther, 2020 Oct;24(4):196-202.
    PMID: 33218511 DOI: 10.1016/j.jbmt.2020.07.007
    BACKGROUND: Studies have shown the involvement of respiratory characteristics and their relationship with impairments in non-specific low back pain (NS-LBP). The effects of core stability with a combined ball and balloon exercise (CBB) on respiratory variables had not been investigated.

    OBJECTIVE: To evaluate the effectiveness of CBB on respiratory variables among NS-LBP patients.

    STUDY DESIGN: pre- and post-experimental study.

    PARTICIPANTS: Forty participants were assigned to an experimental group (EG) [n = 20] and control group (CG) [n = 20] based on the study criteria.

    INTERVENTIONS: The EG received CBB together with routine physiotherapy and the CG received routine physiotherapy over a period of 8 weeks. Participants were instructed to carry out the exercises for 3 days per week. The training was evaluated once a week and the exercises progressed based on the level of pain.

    OUTCOME MEASURES: Primary outcomes were maximum inspiratory pressure (MIP), maximum expiratory pressure (MEP) and maximum voluntary ventilation (MVV). The secondary outcomes were measured in the numeric rating scale (NRS), total faulty breathing scale (TFBS), cloth tape measure (CTM) and lumbo-pelvic stability.

    RESULTS: The MIP increased significantly among the EG when compared with that in the CG (p > 0.05).The EG showed a significant increase in MVV (p = 0.04) when compared to the CG (p = 0.0001). There was a significant reduction in pain for both groups. The MEP, TFBS, chest expansion and core stability showed no changes in either group.

    CONCLUSION: CBB was effective in improving respiratory variables among NS-LBP patients.

    Matched MeSH terms: Maximal Voluntary Ventilation
  8. Sudheer S, Taha Z, Manickam S, Ali A, Cheng PG
    Fungal Biol, 2018 05;122(5):293-301.
    PMID: 29665955 DOI: 10.1016/j.funbio.2018.01.007
    Following the importance of antler-type fruiting bodies of Ganoderma lucidum, in this study, the impact of main growth parameters such as ventilation and light on the development of antler-type fruiting bodies has been investigated together with the determination of physico-chemical properties of antler fruiting bodies. For this, the primordia bags of G. lucidum were kept under controlled ventilation to adjust the CO2 produced by the mushrooms owing to its respiration under light and dark conditions. The bioactive compounds such as phenolics, flavonoids, water-soluble polysaccharides and ganoderic acid showed a two-fold increase in the antler-type fruiting bodies as compared to normal kidney-shaped fruiting bodies. It is assumed from this study that the antler type fruiting bodies are developed due to restricted ventilation which causes an increase in the level of CO2 gas in the air as a result of respiration of mushroom. The shape and colour of antler fruiting bodies again dependent on the light provided in the growth chamber. This study also proves that with the manipulation of light and ventilation antler-type fruiting bodies of G. lucidum could be developed with higher quantity of bioactive compounds and with higher antioxidant potential.
    Matched MeSH terms: Ventilation
  9. Ching SM, Pang YK, Price D, Cheong AT, Lee PY, Irmi I, et al.
    Respirology, 2014 Jul;19(5):689-93.
    PMID: 24708063 DOI: 10.1111/resp.12291
    BACKGROUND AND OBJECTIVE: Early diagnosis of chronic obstructive pulmonary disease (COPD) in primary care settings is difficult to achieve chiefly due to lack of availability of spirometry. This study estimated the prevalence of airflow limitation among chronic smokers using a handheld spirometer in this setting.
    METHODS: This is a cross-sectional study performed on consecutive patients who were ≥40 years old with ≥10 pack-years smoking history. Face-to-face interviews were carried out to obtain demographic data and relevant information. Handheld spirometry was performed according to a standard protocol using the COPd-6 device (Model 4000, Vitalograph, Ennis, Ireland) in addition to standard spirometry. Airflow limitation was defined as ratio of forced expiratory volume in 1 s (FEV1 )/forced expiratory volume in 6 s <0.75 (COPd-6) or FEV1 /forced vital capacity <0.7. Multiple logistic regression analyses were used to determine predictors of airflow limitation.
    RESULTS: A total of 416 patients were recruited with mean age of 53 years old. The prevalence of airflow limitation was 10.6% (n = 44) with COPd-6 versus 6% as gauged using standard spirometry. Risk factors for airflow limitation were age >65 years (odds ratio (OR) 3.732 95% confidence interval (CI): 1.100-1.280), a history of 'bad health' (OR 2.524, 95% CI: 1.037-6.142) and low to normal body mass index (OR 2.914, 95% CI: 1.191-7.190).
    CONCLUSIONS: In a primary care setting, handheld spirometry (COPd-6) found a prevalence of airflow limitation of ∼10% in smokers. Patients were older, not overweight and had an ill-defined history of health problems.
    KEYWORDS: Malaysia; chronic obstructive pulmonary disease; prevalence; primary care; smoke
    Study site: Public primary health‐care clinic (Klinik Kesihatan), Sepang District, Selangor, Malaysia
    Matched MeSH terms: Pulmonary Ventilation/physiology*
  10. González-Briones A, Prieto J, De La Prieta F, Herrera-Viedma E, Corchado JM
    Sensors (Basel), 2018 Mar 15;18(3).
    PMID: 29543729 DOI: 10.3390/s18030865
    At present, the domotization of homes and public buildings is becoming increasingly popular. Domotization is most commonly applied to the field of energy management, since it gives the possibility of managing the consumption of the devices connected to the electric network, the way in which the users interact with these devices, as well as other external factors that influence consumption. In buildings, Heating, Ventilation and Air Conditioning (HVAC) systems have the highest consumption rates. The systems proposed so far have not succeeded in optimizing the energy consumption associated with a HVAC system because they do not monitor all the variables involved in electricity consumption. For this reason, this article presents an agent approach that benefits from the advantages provided by a Multi-Agent architecture (MAS) deployed in a Cloud environment with a wireless sensor network (WSN) in order to achieve energy savings. The agents of the MAS learn social behavior thanks to the collection of data and the use of an artificial neural network (ANN). The proposed system has been assessed in an office building achieving an average energy savings of 41% in the experimental group offices.
    Matched MeSH terms: Ventilation
  11. Reuben U, Ismail AF, Ahmad AL, Maina HM, Daud A
    PMID: 31013942 DOI: 10.3390/ijerph16081334
    : The chemicals from laboratories pose a significant risk forinducing erythema, an abnormal redness of the skin, as a result of poor occupational and environmental factors that promote hypersensitivity to a chemical agent. The aim of this present study was to determine the occupational and environmental risk factors influencing the inducement of erythema in laboratory workers due to exposure to chemicals. This was a cross-sectional study on a population-based sample of Nigerian university laboratory workers. Data were collected using the erythema index meter and an indoor air control meter. The study included 287 laboratory workers. The laboratory workers who properly used personal protective equipment (PPE) were 60% less likely to have induced erythema (adjusted odds ratio (AOR) = 0.40; 95% confidence interval CI: 0.22-0.77; probability value p = 0.011). The chemical mixture exceeding the permissible exposure limit (PEL) was found to have a small effect in inducing the erythema (AOR = 4.22; 95%CI: 2.88-12.11; p = 0.004). Most of the sampled laboratories where the respondents worked had unsuitable temperatures (AOR = 8.21; 95% CI: 4.03-15.01; p = 0.001). Erythema was more frequently found in the respondents who spent 4-5h in the laboratory (AOR = 3.11; 95%CI: 1.77-9.23; p = 0.001). However, high levels of ventilation reduce the likelihood of erythema in a laboratory by 82% (0.18). Multiple logistic regressions revealed that PPE, PEL, exposure time, temperature, and ventilation were the probable predictive factors associated with the inducement of erythema. Providing better educational knowledge and improving the attitude towards hazards and safety in a laboratory would lead to reduced rates of new cases.
    Matched MeSH terms: Ventilation
  12. Ho JJ, Subramaniam P, Davis PG
    PMID: 26141572 DOI: 10.1002/14651858.CD002271.pub2
    BACKGROUND: Respiratory distress syndrome (RDS) is the single most important cause of morbidity and mortality in preterm infants. In infants with progressive respiratory insufficiency, intermittent positive pressure ventilation (IPPV) with surfactant is the standard treatment for the condition, but it is invasive, potentially resulting in airway and lung injury. Continuous distending pressure (CDP) has been used for the prevention and treatment of RDS, as well as for the prevention of apnoea, and in weaning from IPPV. Its use in the treatment of RDS might reduce the need for IPPV and its sequelae.

    OBJECTIVES: To determine the effect of continuous distending pressure (CDP) on the need for IPPV and associated morbidity in spontaneously breathing preterm infants with respiratory distress.Subgroup analyses were planned on the basis of birth weight (> or < 1000 or 1500 g), gestational age (groups divided at about 28 weeks and 32 weeks), methods of application of CDP (i.e. CPAP and CNP), application early versus late in the course of respiratory distress and high versus low pressure CDP and application of CDP in tertiary compared with non-tertiary hospitals, with the need for sensitivity analysis determined by trial quality.At the 2008 update, the objectives were modified to include preterm infants with respiratory failure.

    SEARCH METHODS: We used the standard search strategy of the Neonatal Review Group. This included searches of the Oxford Database of Perinatal Trials, the Cochrane Central Register of Controlled Trials (CENTRAL, 2015 Issue 4), MEDLINE (1966 to 30 April 2015) and EMBASE (1980 to 30 April 2015) with no language restriction, as well as controlled-trials.com, clinicaltrials.gov and the International Clinical Trials Registry Platform of the World Health Organization (WHO).

    SELECTION CRITERIA: All random or quasi-random trials of preterm infants with respiratory distress were eligible. Interventions were continuous distending pressure including continuous positive airway pressure (CPAP) by mask, nasal prong, nasopharyngeal tube or endotracheal tube, or continuous negative pressure (CNP) via a chamber enclosing the thorax and the lower body, compared with spontaneous breathing with oxygen added as necessary.

    DATA COLLECTION AND ANALYSIS: We used standard methods of The Cochrane Collaboration and its Neonatal Review Group, including independent assessment of trial quality and extraction of data by each review author.

    MAIN RESULTS: We included six studies involving 355 infants - two using face mask CPAP, two CNP, one nasal CPAP and one both CNP (for less ill babies) and endotracheal CPAP (for sicker babies). For this update, we included no new trials.Continuous distending pressure (CDP) is associated with lower risk of treatment failure (death or use of assisted ventilation) (typical risk ratio (RR) 0.65, 95% confidence interval (CI) 0.52 to 0.81; typical risk difference (RD) -0.20, 95% CI -0.29 to -0.10; number needed to treat for an additional beneficial outcome (NNTB) 5, 95% CI 4 to 10; six studies; 355 infants), lower overall mortality (typical RR 0.52, 95% CI 0.32 to 0.87; typical RD -0.15, 95% CI -0.26 to -0.04; NNTB 7, 95% CI 4 to 25; six studies; 355 infants) and lower mortality in infants with birth weight above 1500 g (typical RR 0.24, 95% CI 0.07 to 0.84; typical RD -0.28, 95% CI -0.48 to -0.08; NNTB 4, 95% CI 2.00 to 13.00; two studies; 60 infants). Use of CDP is associated with increased risk of pneumothorax (typical RR 2.64, 95% CI 1.39 to 5.04; typical RD 0.10, 95% CI 0.04 to 0.17; number needed to treat for an additional harmful outcome (NNTH) 17, 95% CI 17.00 to 25.00; six studies; 355 infants). We found no difference in bronchopulmonary dysplasia (BPD), defined as oxygen dependency at 28 days (three studies, 260 infants), as well as no difference in outcome at nine to 14 years (one study, 37 infants).

    AUTHORS' CONCLUSIONS: In preterm infants with respiratory distress, the application of CDP as CPAP or CNP is associated with reduced respiratory failure and mortality and an increased rate of pneumothorax. Four out of six of these trials were done in the 1970s. Therefore, the applicability of these results to current practice is difficult to assess. Further research is required to determine the best mode of administration.

    Matched MeSH terms: Intermittent Positive-Pressure Ventilation/adverse effects
  13. Ho JJ, Subramaniam P, Henderson-Smart DJ, Davis PG
    PMID: 12076445
    BACKGROUND: Respiratory distress syndrome (RDS) is the single most important cause of morbidity and mortality in preterm infants (Greenough 1998, Bancalari 1992). Intermittent positive pressure ventilation (IPPV) with surfactant is the standard treatment for the condition. The major difficulty with IPPV is that it is invasive, resulting in airway and lung injury and contributing to the development of chronic lung disease.

    OBJECTIVES: In spontaneously breathing preterm infants with RDS, to determine if continuous distending pressure (CDP) reduces the need for IPPV and associated morbidity without adverse effects.

    SEARCH STRATEGY: The standard search strategy of the Neonatal Review group was used. This included searches of the Oxford Database of Perinatal Trials, Cochrane Controlled Trials Register (The Cochrane Library, Issue 1, 2002), MEDLINE (1966-January 2002), and EMBASE (1980-January 2002), previous reviews including cross references, abstracts, conference and symposia proceedings, expert informants, journal hand searching mainly in the English language.

    SELECTION CRITERIA: All trials using random or quasi-random allocation of preterm infants with RDS were eligible. Interventions were continuous distending pressure including continuous positive airway pressure (CPAP) by mask, nasal prong, nasopharyngeal tube, or endotracheal tube, or continuous negative pressure (CNP) via a chamber enclosing the thorax and lower body, compared with standard care.

    DATA COLLECTION AND ANALYSIS: Standard methods of the Cochrane Collaboration and its Neonatal Review Group were used, including independent assessment of trial quality and extraction of data by each author.

    MAIN RESULTS: CDP is associated with a lower rate of failed treatment (death or use of assisted ventilation) [summary RR 0.70 (0.55, 0.88), RD -0.22 (-0.35, -0.09), NNT 5 (3, 11)], overall mortality [summary RR 0.52 (0.32, 0.87), RD -0.15 (-0.26, -0.04), NNT 7 (4, 25)], and mortality in infants with birthweights above 1500 g [summary RR 0.24 (0.07, 0.84), RD -0.281 (-0.483, -0.078), NNT 4 (2, 13)]. The use of CDP is associated with an increased rate of pneumothorax [summary RR 2.36 (1.25, 5.54), RD 0.14 (0.04, 0.23), NNH 7 (4, 24)].

    REVIEWER'S CONCLUSIONS: In preterm infants with RDS the application of CDP either as CPAP or CNP is associated with benefits in terms of reduced respiratory failure and reduced mortality. CDP is associated with an increased rate of pneumothorax. The applicability of these results to current practice is difficult to assess, given the intensive care setting of the 1970s when four out of five of these trials were done. Where resources are limited, such as in developing countries, CPAP for RDS may have a clinical role. Further research is required to determine the best mode of administration and its role in modern intensive care settings

    Matched MeSH terms: Intermittent Positive-Pressure Ventilation/adverse effects
  14. Ho JJ, Subramaniam P, Henderson-Smart DJ, Davis PG
    PMID: 10908543
    Respiratory distress syndrome (RDS) is the single most important cause of morbidity and mortality in preterm infants (Greenough 1998, Bancalari 1992). Intermittent positive pressure ventilation (IPPV) with surfactant is the standard treatment for the condition. The major difficulty with IPPV is that it is invasive, resulting in airway and lung injury and contributing to the development of chronic lung disease.
    Matched MeSH terms: Intermittent Positive-Pressure Ventilation/adverse effects
  15. Ho JJ, Subramaniam P, Henderson-Smart DJ, Davis PG
    PMID: 11034747
    BACKGROUND: Respiratory distress syndrome (RDS) is the single most important cause of morbidity and mortality in preterm infants (Greenough 1998, Bancalari 1992). Intermittent positive pressure ventilation (IPPV) with surfactant is the standard treatment for the condition. The major difficulty with IPPV is that it is invasive, resulting in airway and lung injury and contributing to the development of chronic lung disease.

    OBJECTIVES: In spontaneously breathing preterm infants with RDS, to determine if continuous distending pressure (CDP) reduces the need for IPPV and associated morbidity without adverse effects.

    SEARCH STRATEGY: The standard search strategy of the Neonatal Review group was used. This included searches of the Oxford Database of Perinatal Trials, Cochrane Controlled Trials Register, MEDLINE (1966-Jan. 2000), previous reviews including cross references, abstracts, conference and symposia proceedings, expert informants, journal hand searching mainly in the English language.

    SELECTION CRITERIA: All trials using random or quasi-random patient allocation of newborn infants with RDS were eligible. Interventions were continuous distending pressure including continuous positive airway pressure (CPAP) by mask, nasal prong, nasopharyngeal tube, or endotracheal tube, or continuous negative pressure (CNP) via a chamber enclosing the thorax and lower body, compared with standard care.

    DATA COLLECTION AND ANALYSIS: Standard methods of the Cochrane Collaboration and its Neonatal Review Group, including independent assessment of trial quality and extraction of data by each author, were used.

    MAIN RESULTS: CDP is associated with a lower rate of failed treatment (death or use of assisted ventilation), overall mortality, and mortality in infants with birthweights above 1500 g. The use of CDP is associated with an increased rate of pneumothorax.

    REVIEWER'S CONCLUSIONS: In preterm infants with RDS the application of CDP either as CPAP or CNP is associated with some benefits in terms of reduced respiratory failure and reduced mortality. CDP is associated with an increased rate of pneumothorax. The applicability of these results to current practice is difficult to assess, given the outdated methods to administer CDP, low use of antenatal corticosteroids, non-availability of surfactant and the intensive care setting of the 1970s when these trials were done. Where resources are limited, such as in developing countries, CPAP for RDS may have a clinical role. Further research is required to determine the best mode of administration and its role in modern intensive care settings

    Matched MeSH terms: Intermittent Positive-Pressure Ventilation/adverse effects
  16. Ho JJ, Subramaniam P, Davis PG
    Cochrane Database Syst Rev, 2020 10 15;10:CD002271.
    PMID: 33058208 DOI: 10.1002/14651858.CD002271.pub3
    BACKGROUND: Respiratory distress, particularly respiratory distress syndrome (RDS), is the single most important cause of morbidity and mortality in preterm infants. In infants with progressive respiratory insufficiency, intermittent positive pressure ventilation (IPPV) with surfactant has been the usual treatment, but it is invasive, potentially resulting in airway and lung injury. Continuous positive airway pressure (CPAP) has been used for the prevention and treatment of respiratory distress, as well as for the prevention of apnoea, and in weaning from IPPV. Its use in the treatment of RDS might reduce the need for IPPV and its sequelae.

    OBJECTIVES: To determine the effect of continuous distending pressure in the form of CPAP on the need for IPPV and associated morbidity in spontaneously breathing preterm infants with respiratory distress.

    SEARCH METHODS: We used the standard strategy of Cochrane Neonatal to search CENTRAL (2020, Issue 6); Ovid MEDLINE and Epub Ahead of Print, In-Process & Other Non-Indexed Citations, Daily and Versions; and CINAHL on 30 June 2020. We also searched clinical trials databases and the reference lists of retrieved articles for randomised controlled trials and quasi-randomised trials.

    SELECTION CRITERIA: All randomised or quasi-randomised trials of preterm infants with respiratory distress were eligible. Interventions were CPAP by mask, nasal prong, nasopharyngeal tube or endotracheal tube, compared with spontaneous breathing with supplemental oxygen as necessary.

    DATA COLLECTION AND ANALYSIS: We used standard methods of Cochrane and its Neonatal Review Group, including independent assessment of risk of bias and extraction of data by two review authors. We used the GRADE approach to assess the certainty of evidence. Subgroup analyses were planned on the basis of birth weight (greater than or less than 1000 g or 1500 g), gestational age (groups divided at about 28 weeks and 32 weeks), timing of application (early versus late in the course of respiratory distress), pressure applied (high versus low) and trial setting (tertiary compared with non-tertiary hospitals; high income compared with low income) MAIN RESULTS: We included five studies involving 322 infants; two studies used face mask CPAP, two studies used nasal CPAP and one study used endotracheal CPAP and continuing negative pressure for a small number of less ill babies. For this update, we included one new trial. CPAP was associated with lower risk of treatment failure (death or use of assisted ventilation) (typical risk ratio (RR) 0.64, 95% confidence interval (CI) 0.50 to 0.82; typical risk difference (RD) -0.19, 95% CI -0.28 to -0.09; number needed to treat for an additional beneficial outcome (NNTB) 6, 95% CI 4 to 11; I2 = 50%; 5 studies, 322 infants; very low-certainty evidence), lower use of ventilatory assistance (typical RR 0.72, 95% CI 0.54 to 0.96; typical RD -0.13, 95% CI -0.25 to -0.02; NNTB 8, 95% CI 4 to 50; I2 = 55%; very low-certainty evidence) and lower overall mortality (typical RR 0.53, 95% CI 0.34 to 0.83; typical RD -0.11, 95% CI -0.18 to -0.04; NNTB 9, 95% CI 2 to 13; I2 = 0%; 5 studies, 322 infants; moderate-certainty evidence). CPAP was associated with increased risk of pneumothorax (typical RR 2.48, 95% CI 1.16 to 5.30; typical RD 0.09, 95% CI 0.02 to 0.16; number needed to treat for an additional harmful outcome (NNTH) 11, 95% CI 7 to 50; I2 = 0%; 4 studies, 274 infants; low-certainty evidence). There was no evidence of a difference in bronchopulmonary dysplasia, defined as oxygen dependency at 28 days (RR 1.04, 95% CI 0.35 to 3.13; I2 = 0%; 2 studies, 209 infants; very low-certainty evidence). The trials did not report use of surfactant, intraventricular haemorrhage, retinopathy of prematurity, necrotising enterocolitis and neurodevelopment outcomes in childhood.

    AUTHORS' CONCLUSIONS: In preterm infants with respiratory distress, the application of CPAP is associated with reduced respiratory failure, use of mechanical ventilation and mortality and an increased rate of pneumothorax compared to spontaneous breathing with supplemental oxygen as necessary. Three out of five of these trials were conducted in the 1970s. Therefore, the applicability of these results to current practice is unclear. Further studies in resource-poor settings should be considered and research to determine the most appropriate pressure level needs to be considered.

    Matched MeSH terms: Intermittent Positive-Pressure Ventilation/adverse effects
  17. Ho JJ, Subramaniam P, Sivakaanthan A, Davis PG
    Cochrane Database Syst Rev, 2020 10 15;10:CD002975.
    PMID: 33058139 DOI: 10.1002/14651858.CD002975.pub2
    BACKGROUND: The application of continuous positive airway pressure (CPAP) has been shown to have some benefits in the treatment of preterm infants with respiratory distress. CPAP has the potential to reduce lung damage, particularly if applied early before atelectasis has occurred. Early application may better conserve an infant's own surfactant stores and consequently may be more effective than later application.

    OBJECTIVES: • To determine if early compared with delayed initiation of CPAP results in lower mortality and reduced need for intermittent positive-pressure ventilation in preterm infants in respiratory distress ○ Subgroup analyses were planned a priori on the basis of weight (with subdivisions at 1000 grams and 1500 grams), gestation (with subdivisions at 28 and 32 weeks), and according to whether surfactant was used ▫ Sensitivity analyses based on trial quality were also planned ○ For this update, we have excluded trials using continuous negative pressure SEARCH METHODS: We used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL; 2020, Issue 6), in the Cochrane Library; Ovid MEDLINE(R) and Epub Ahead of Print, In-Process & Other Non-Indexed Citations Daily and Versions(R); and the Cumulative Index to Nursing and Allied Health Literatue (CINAHL), on 30 June 2020. We also searched clinical trials databases and the reference lists of retrieved articles for randomised controlled trials (RCTs) and quasi-RCTs.

    SELECTION CRITERIA: We included trials that used random or quasi-random allocation to either early or delayed CPAP for spontaneously breathing preterm infants in respiratory distress.

    DATA COLLECTION AND ANALYSIS: We used the standard methods of Cochrane and Cochrane Neonatal, including independent assessment of trial quality and extraction of data by two review authors. We used the GRADE approach to assess the certainty of evidence.

    MAIN RESULTS: We found four studies that recruited a total of 119 infants. Two were quasi-randomised, and the other two did not provide details on the method of randomisation or allocation used. None of these studies used blinding of the intervention or the outcome assessor. Evidence showed uncertainty about whether early CPAP has an effect on subsequent use of intermittent positive-pressure ventilation (IPPV) (typical risk ratio (RR) 0.77, 95% confidence interval (CI) 0.43 to 1.38; typical risk difference (RD) -0.08, 95% CI -0.23 to 0.08; I² = 0%, 4 studies, 119 infants; very low-certainty evidence) or mortality (typical RR 0.93, 95% CI 0.43 to 2.03; typical RD -0.02, 95% CI -0.15 to 0.12; I² = 33%, 4 studies, 119 infants; very low-certainty evidence). The outcome 'failed treatment' was not reported in any of these studies. There was an uncertain effect on air leak (pneumothorax) (typical RR 1.09, 95% CI 0.39 to 3.04, I² = 0%, 3 studies, 98 infants; very low-certainty evidence). No trials reported intraventricular haemorrhage or necrotising enterocolitis. No cases of retinopathy of prematurity were reported in one study (21 infants). One case of bronchopulmonary dysplasia was reported in each group in one study involving 29 infants. Long-term outcomes were not reported.

    AUTHORS' CONCLUSIONS: All four small trials included in this review were performed in the 1970s or the early 1980s, and we are very uncertain whether early application of CPAP confers clinical benefit in the treatment of respiratory distress, or whether it is associated with any adverse effects. Further trials should be directed towards establishing the appropriate level of CPAP and the timing and method of administration of surfactant when used along with CPAP.

    Matched MeSH terms: Intermittent Positive-Pressure Ventilation/statistics & numerical data
  18. Subramaniam P, Ho JJ, Davis PG
    Cochrane Database Syst Rev, 2021 Oct 18;10(10):CD001243.
    PMID: 34661278 DOI: 10.1002/14651858.CD001243.pub4
    BACKGROUND: Cohort studies have suggested that nasal continuous positive airway pressure (CPAP) starting in the immediate postnatal period before the onset of respiratory disease (prophylactic CPAP) may be beneficial in reducing the need for intubation and intermittent positive pressure ventilation (IPPV), and in preventing bronchopulmonary dysplasia (BPD), in preterm or low birth weight infants.

    OBJECTIVES: To determine if prophylactic nasal CPAP (started within the first 15 minutes) or very early nasal CPAP regardless of respiratory status (started within the first hour of life), reduces the use of mechanical ventilation and the incidence of bronchopulmonary dysplasia without any adverse effects in preterm infants.

    SEARCH METHODS: A comprehensive search was run on 6 November 2020 in the Cochrane Central Register of Controlled Trials (CENTRAL via CRS Web) and MEDLINE via Ovid. We also searched the reference lists of retrieved studies.

    SELECTION CRITERIA: We included all randomised controlled trials (RCTs) and quasi-RCTs in preterm infants (under 37 weeks of gestation). We included trials if they compared prophylactic nasal CPAP (started within the first 15 minutes) or very early nasal CPAP (started within the first hour of life) in infants with minimal signs of respiratory distress with 'supportive care', such as supplemental oxygen therapy, standard nasal cannula, or mechanical ventilation. We excluded studies where prophylactic CPAP was compared with CPAP along with co-interventions.

    DATA COLLECTION AND ANALYSIS: We used the standard methods of Cochrane Neonatal, including independent study selection, assessment of trial quality, and extraction of data by two review authors.

    MAIN RESULTS: We included eight trials (seven from the previous version of the review and one new study), recruiting 3201 babies, in the meta-analysis. Four trials, involving 765 babies, compared CPAP with supportive care, and three trials (2364 babies) compared CPAP with mechanical ventilation. One trial (72 babies) compared prophylactic CPAP with very early CPAP. Apart from a lack of blinding of the intervention, we judged seven studies to have a low risk of bias. However, one study had a high risk of selection bias. Prophylactic or very early CPAP compared to supportive care There may be a reduction in failed treatment (risk ratio (RR) 0.6, 95% confidence interval (CI) 0.49 to 0.74; risk difference (RD) -0.16, 95% CI -0.34 to 0.02; 4 studies, 765 infants; very low certainty evidence). CPAP possibly reduces BPD at 36 weeks (RR 0.76, 95% CI 0.51 to 1.14; 3 studies, 683 infants, moderate certainty evidence); there may be little or no difference in death (RR 1.04, 95% CI 0.56 to 1.93; 4 studies, 765 infants; moderate certainty evidence). Prophylactic CPAP may reduce the composite outcome of death or BPD (RR 0.69, 95% CI 0.40 to 1.19; 1 study, 256 infants; low certainty evidence). There may be no difference in pulmonary air leak (pneumothorax) (RR 0.75, 95% CI 0.35 to 1.16; 3 studies, 568 infants; low certainty evidence), or intraventricular haemorrhage (IVH) Grade 3 or 4 (RR 0.96, 95% CI 0.39 to 2.37; 2 studies, 486 infants; moderate certainty evidence). Neurodevelopmental impairment was not reported in any of the studies. Prophylactic or very early CPAP compared to mechanical ventilation There was probably a reduction in the incidence of BPD at 36 weeks (RR 0.89, 95% CI 0.8 to 0.99; RD -0.04, 95% CI -0.08 to 0.00; 3 studies, 2150 infants; moderate certainty evidence); and death or BPD (RR 0.89, 95% CI 0.81 to 0.97; RD -0.05, 95% CI -0.09 to 0.01; 3 studies, 2358 infants; moderate certainty evidence). There was also probably a reduction in the need for mechanical ventilation (failed treatment) (RR 0.49, 95% CI 0.45 to 0.54; RD -0.50, 95% CI -0.54 to -0.45; 2 studies, 1042 infants; moderate certainty evidence). There was probably a reduction in the incidence of death (RR 0.82, 95% CI 0.66 to 1.03; 3 studies, 2358 infants; moderate certainty evidence); pulmonary air leak (pneumothorax) (RR 1.24, 95% CI 0.91 to 1.69; 3 studies, 2357 infants; low certainty evidence); and IVH Grade 3 or 4 (RR 1.09, 95% CI 0.86 to 1.39; 3 studies, 2301 infants; moderate certainty evidence). One study in this comparison reported that there was probably little or no difference between the groups in the incidence of neurodevelopmental impairment at 18 to 22 months (RR 0.91, 95% CI 0.62 to 1.32; 976 infants; moderate certainty evidence). Prophylactic CPAP compared with very early CPAP There was one study in this comparison. We are very uncertain whether there is any difference in the incidence of BPD (RR 0.5, 95% CI 0.05 to 5.27; very low certainty evidence). The combined outcome of death and BPD was not reported, and failed treatment was reported but without data. There may have been little to no effect on death (RR 0.75, 95% CI 0.29 to1.94; 1 study, 72 infants; very low certainty evidence). Intraventricular haemorrhage Grade 3 or 4 and neurodevelopmental outcomes were not reported in this study. Pulmonary air leak (pneumothorax) was reported in this study, but there were no events in either group.

    AUTHORS' CONCLUSIONS: For preterm and very preterm infants, there is insufficient evidence to evaluate prophylactic CPAP compared to oxygen therapy and other supportive care. When compared to mechanical ventilation, prophylactic nasal CPAP in very preterm infants reduces the incidence of BPD, the combined outcome of death and BPD, and mechanical ventilation. There is probably no difference in neurodevelopmental impairment at 18 to 22 months of age. When prophylactic CPAP is compared to early CPAP, we are very uncertain about whether there is any difference between prophylactic and very early CPAP. There is no information about the effect of prophylactic or very early CPAP in late preterm infants. There is one study awaiting classification.

    Matched MeSH terms: Intermittent Positive-Pressure Ventilation
  19. Wu CL, Hsu WH, Chiang CD, Kao CH, Hung DZ, King SL, et al.
    J. Toxicol. Clin. Toxicol., 1997;35(3):241-8.
    PMID: 9140317 DOI: 10.3109/15563659709001207
    BACKGROUND: Taking Sauropus androgynus, a Malaysian food, to reduce weight began as a fad in Taiwan in 1994. Some advocates of this fad developed pulmonary dysfunction. The aim of this study is to report the lung injury in patients taking Sauropus androgynus.

    METHODS: From July 1995 to November 1995, we investigated 104 nonsmoking patients (one male and 103 females) with chest roentgenography, pulmonary function, test, and Technetium 99m-labeled diethylene triamine penta-acetate (Tc-99m DTPA) radioaerosol inhalation lung scintigraphy.

    RESULTS: Among the 90 patients receiving Tc-99m DTPA inhalation lung scan, 46 (51.1%) patients had increased clearance of Tc-99m DTPA from lung and 20 (22.2%) patients had inhomogeneous deposition of the submicronic radioaerosol. Eighteen (18/100) patients had obstructive ventilatory impairment in pulmonary function test. Analyzing the results, we found that the patients with respiratory symptoms (n = 42) took more vegetables (p = 0.016), had increased clearance of Tc-99m DTPA (p = 0.010) and had lower FEV1 (p = 0.001), FEV1/FVC (p < 0.001), FEF25-75 (p = 0.001), VC (p = 0.002) and DLCO (p = 0.009) than the patients without respiratory symptoms (n = 62). FEV1 and FEV1/FVC were significantly reduced in patients with severe impairment of alveolar permeability. The cumulative dosage and duration of exposure were significantly associated with the reduction of FEV1 and FEV1/FVC.

    CONCLUSION: The lung injury after taking Sauropus androgynus involves alveoli and/or small airways and is manifest as obstructive ventilatory impairment with inhomogeneous aerosol distribution and increased lung epithelial permeability.
    Matched MeSH terms: Pulmonary Ventilation
  20. Al-Shamiry, Faisal Mohammed Seif, Desa Ahmad
    MyJurnal
    Natural ventilation is defined as the number of air exchanges per hour per unit floor area necessary
    to reduce high indoor air temperature and humidity. In addition, it maintains the concentration of carbon dioxide. Natural ventilation is preferred in mechanical system as the ventilation opening is built into the greenhouse, with lower construction cost and no energy and maintenance inputs are required. A mathematical model to quantify natural ventilation rates was developed and verified in large-scale greenhouse structures. For this purpose, four Naturally Ventilated Tropical Greenhouse Structures were designed and constructed at the Malaysian Agricultural Research and Development Institute (MARDI). These were single, double, triple, and quadruple span structures with floor areas of 500 m2, 1000 m2, 1500 m2 and 2000 m2, respectively. This paper presents the validation of a mathematical model which was developed to quantify natural ventilation rates which are very crucial to reduce high in-house temperature built up in the tropics. Regression equations of natural ventilation against wind speed were found to be Φw = 0.0632V, Φw= 0.0395V, Φw= 0.0316Vand Φw=0.0276V for the single, double, triple and quadruple spans, respectively. Meanwhile, coefficients of determination showed strong relationships between ventilation rate and wind speed, with R2 = 0.9999 for all structures. Larger floor area was found to have higher in-house temperature than smaller ones. Ventilation rate inside the single-span structure was found to be higher compared to the multi-span structures, which increased linearly with the increasing wind speed at the eaves of structure.
    Matched MeSH terms: Ventilation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links