Materials and methods: A cross-sectional study was conducted on 520 women from three different government health clinics in Kuantan and IIUM Family Health Clinic from February to April 2018. Data were collected using a self-administered questionnaire on socio-demographic factors and knowledge of breast cancer and its effect on the behavioral adoption of BSE.
Results: Significant difference was found between socio-demographic characteristics and behavioral adoption of BSE. However, only breast screening and the best time for screening were found to be significant with the behavioral adoption of BSE and knowledge of breast cancer.
Conclusion: It is found that most women in Kuantan, Pahang perform BSE but were still unaware of the importance of performing BSE for early breast cancer detection. This study was expected to enhance women's awareness of the benefits of performing BSE.
METHODS: The medical records of all patients who underwent breast lump excision under AAA in combination with electrical stimulation at traditional acupuncture points in 2016 were examined. All of them (n = 17) received electrostimulation (2-4 Hz) using single needles inserted at bilateral LI4 and PC6. They also underwent insertion of four acupuncture needles at the lump site, which were electrically stimulated at 30 Hz frequency.
RESULTS: All surgical procedures were successful with minimal use of analgesics and local anesthetic. The median pain score reported was 1/10 (interquartile range (IQR) = 2/10) at the first hour, and slightly increased to 2/10 (IQR = 2/10) between 24 and 48 h of the surgery. No major postoperative adverse events were documented, except for drowsiness in one case.
CONCLUSION: AAA was found to be generally safe and effective for anaesthesia and analgesia in breast lump excision. However, a large-scale randomized controlled study is required to verify the findings.
METHOD: TQ-nanoparticles were prepared and optimized by using two different formulations with different drugs to PLGA-PEG ratio (1:20 and 1:7) and different PLGA-PEG to Pluronic F68 ratio (10:1 and 2:1). The morphology and size were determined using TEM and DLS. Characterization of particles was done using UV-VIS, ATR-IR, entrapment efficiency, and drug release. The effects of drug, polymer, and surfactants were compared between the two formulations. Cytotoxicity assay was performed using MTS assay.
RESULTS: TEM finding showed 96% of particles produced with 1:7 drug to PLGA-PEG were less than 90 nm in size and spherical in shape. This was confirmed with DLS which showed smaller particle size than those formed with 1:20 drug to PLGA-PEG ratio. Further analysis showed zeta potential was negatively charged which could facilitate cellular uptake as reported previously. In addition, PDI value was less than 0.1 in both formulations indicating monodispersed and less broad in size distribution. The absorption peak of PLGA-PEG-TQ-Nps was at 255 nm. The 1:7 drug to polymer formulation was selected for further analysis where the entrapment efficiency was 79.9% and in vitro drug release showed a maximum release of TQ of 50%. Cytotoxicity result showed IC50 of TQ-nanoparticle at 20.05 μM and free TQ was 8.25 μM.
CONCLUSION: This study showed that nanoparticle synthesized with 1:7 drug to PLGA-PEG ratio and 2:1 PLGA-PEG to Pluronic F68 formed nanoparticles with less than 100 nm and had spherical shape as confirmed with DLS. This could facilitate its transportation and absorption to reach its target. There was conserved TQ stability as exhibited slow release of this volatile oil. The TQ-nanoparticles showed selective cytotoxic effect toward UACC 732 cells compared to MCF-7 breast cancer cells.
MATERIALS AND METHODS: In hepatoprotective activity, liver damage was induced by treating rats with 1.0 mL carbon tetrachloride (CCl4)/kg and MEA extract was administered at a dose of 50, 250 and 500 mg/kg 24 h before intoxication with CCl4. Cytotoxicity study was performed on MCF-7 (human breast cancer), DBTRG (human glioblastoma), PC-3 (human prostate cancer) and U2OS (human osteosarcoma) cell lines. 1H, 13C-NMR (nuclear magnetic resonance), and IR (infrared) spectral analyses were also conducted for MEA extract.
RESULTS: In hepatoprotective activity evaluation, MEA extract at a higher dose level of 500 mg/kg showed significant (p<0.05) potency. In cytotoxicity study, MEA extract was more toxic towards MCF-7 and DBTRG cell lines causing 78.7% and 64.3% cell death, respectively. MEA extract in 1H, 13C-NMR, and IR spectra exhibited bands, signals and J (coupling constant) values representing aromatic/phenolic constituents.
CONCLUSIONS: From the results, it could be concluded that MEA extract has potency to inhibit hepatotoxicity and MCF-7 and DBTRG cancer cell lines which might be due to the phenolic compounds depicted from NMR and IR spectra.
METHODS: One hundred and one formalin-fixed and paraffin-processed triple-negative breast cancer cases from the University of Malaya Medical Centre were tested immunohistochemically for cytokeratins 5/6 and 14, PTEN, and IGFBP2. The resulting slides were scored for proportion and intensity of staining.
RESULTS: Loss of tumor nuclear and cytoplasmic staining for PTEN occurred in 48.3% of cases and was significantly associated with younger age at diagnosis (47 years compared with 57 years in those without PTEN loss; P = .005). Independent predictors of PTEN loss were late stage at presentation (P = .026), cytokeratin 5/6 positivity (P = .028), and IGFBP2 expression (P = .042). High levels of IGFBP2 expression were seen in 32% of cases; an independent predictor of high levels was cytokeratin 14 negativity (P = .005). PTEN loss and high levels of IGFBP2 expression were associated with poorer survival, but neither of these trends was significant.
CONCLUSIONS: PTEN loss is a frequent event in triple-negative breast cancers and is significantly associated with younger age at onset of breast cancer, late stage, and IGFBP2 expression.