Displaying publications 1 - 20 of 70 in total

Abstract:
Sort:
  1. Ram SP, Malik AS
    Med J Malaysia, 1994 Mar;49(1):96-9.
    PMID: 8058000
    Three children with cardiac tumors are described: a 12-year-old female child who had left atrial myxoma, and two males having rhabdomyoma of the right ventricle associated with tuberous sclerosis. The child with left atrial myxoma was symptomatic and the tumour was subsequently excised. The other two children with rhabdomyoma were managed conservatively.
    Matched MeSH terms: Heart Ventricles
  2. Kwon WK, Sung TY, Yu GY, Sidik H, Kang WS, Lee Y, et al.
    J Anesth, 2016 Apr;30(2):223-31.
    PMID: 26577248 DOI: 10.1007/s00540-015-2094-9
    BACKGROUND: The direct impact of sevoflurane on intraoperative left ventricular (LV) systolic performance during cardiac surgery has not been fully elucidated. Peak systolic tissue Doppler velocities of the lateral mitral annulus (S') have been used to evaluate LV systolic long-axis performance. We hypothesized that incremental sevoflurane concentration (1.0-3.0 inspired-vol%) would dose-dependently reduce S' in patients undergoing cardiac surgery due to mitral or aortic insufficiency.

    METHODS: In 20 patients undergoing cardiac surgery in sevoflurane-remifentanil anesthesia, we analyzed intraoperative S' values which were determined after 10 min exposure to sevoflurane at 1.0, 2.0, and 3.0 inspired-vol% (T1, T2, and T3, respectively) with a fixed remifentanil dose (1.0 μg/kg/min) using transesophageal echocardiography.

    RESULTS: Linear mixed-effect modeling demonstrated dose-dependent declines in S' according to the end-tidal sevoflurane concentration increments (C(ET)-sevoflurane, p < 0.001): the mean value of S' reduction for each 1.0 vol%-increment of C(ET)-sevoflurane was 1.7 cm/s (95 % confidence interval 1.4-2.1 cm/s). Medians of S' at T1, T2, and T3 (9.6, 8.9, and 7.5 cm/s, respectively) also exhibited significant declines (by 6.6, 15.6, and 21.2 % for T1 vs. T2, T2 vs. T3, and T1 vs. T3, p < 0.001, =0.002, and <0.001 in Friedman pairwise comparisons, respectively).

    CONCLUSIONS: Administering sevoflurane as a part of a sevoflurane-remifentanil anesthesia regimen appears to dose-dependently reduce S', indicating LV systolic performance, in patients undergoing cardiac surgery. Further studies may be required to evaluate the clinical implications of these findings.

    Matched MeSH terms: Heart Ventricles
  3. Adi O, Fong CP, Azil A, Wahab SFA
    Ultrasound J, 2019 Feb 25;11(1):1.
    PMID: 31359296 DOI: 10.1186/s13089-019-0116-9
    BACKGROUND: We report a case study of fat embolism seen on ultrasound at right internal jugular vein during central venous cannulation in a patient diagnosed with fat embolism syndrome. This case demonstrates the importance of ultrasound for evaluation of trauma cases with suspicion of fat embolism.

    CASE PRESENTATION: A 23-year-old trauma patient with closed fracture of left femoral shaft and left humerus presented to our emergency department (ED). 11 h after admission to ED, patient became confused, hypoxic and hypotensive. He was then intubated for respiratory failure and mechanically ventilated. Transesophageal ultrasound revealed hyperdynamic heart, dilated right ventricle with no regional wall abnormalities and no major aorta injuries. Whole-body computed tomography was normal. During central venous cannulation of right internal jugular vein (IJV), we found free floating mobile hyperechoic spots, located at the anterior part of the vein. A diagnosis of fat embolism syndrome later was made based on the clinical presentation of long bone fractures and fat globulin in the blood. Despite aggressive fluid resuscitation, patient was a non-responder and needed vasopressor infusion for persistent shock. Blood aspirated during cannulation from the IJV revealed a fat globule. Patient underwent uneventful orthopedic procedures and was discharged well on day 5 of admission.

    CONCLUSIONS: Point-of-care ultrasound findings of fat embolism in central vein can facilitate and increase the suspicion of fat embolism syndrome.

    Matched MeSH terms: Heart Ventricles
  4. Chuah JS, Wong WL, Bakin S, Lim RZM, Lee EP, Tan JH
    Ann Med Surg (Lond), 2021 May;65:102294.
    PMID: 33948169 DOI: 10.1016/j.amsu.2021.102294
    Introduction and importance: A totally implantable venous access device (TIVAD), also referred to as 'chemoport', is frequently used for oncology patients. Chemoport insertion via the subclavian vein access may compress the catheter between the first rib and the clavicle, resulting in pinch-off syndrome (POS). The sequela includes catheter transection and subsequent embolization. It is a rare complication with incidence reported to be 1.1-5.0% and can lead to a devastating outcomes.

    Case presentation: 50-year-old male had his chemoport inserted for adjuvant chemotherapy 3 years ago. During the removal, remaining half of the distal catheter was not found. There was no difficulties during the removal. Chest xray revealed that the fractured catheter had embolized to the right ventricle. Further history taking, he did experienced occasional palpitation and chest discomfort for the past six months. Electrocardiogram and cardiac enzymes were normal. Urgent removal of the fractured catheter via the percutaneous endovascular approach, under fluoroscopic guidance by an experience interventional radiologist was done. The procedure was successful without any complication. Patient made an uneventful recovery. He was discharged the following day, and was well during his 3rd month follow up.

    Conclusion: Early detection and preventive measures can be done to prevent pinch-off syndrome. Unrecognized POS can result in fatal complications such as cardiac arrhythmia and septic embolization. Retrieval via the percutaneous endovascular approach provide excellent outcome in the case of embolized fractured catheter.

    Matched MeSH terms: Heart Ventricles
  5. Sheila Rani Kovil George, Sivalingam Nalliah
    MyJurnal
    The purpose of this prospective longitudinal study was to investigate the maternal cardiac haemodynamic and structural changes that occur
    in pregnancies with uncomplicated hyperemesis gravidarum in a selected Malaysian population. Nine women underwent serial echocardiography beginning at 12 weeks of gestation and throughout pregnancy at monthly intervals. Their echocardiograms were repeated at 6 and 12 weeks following delivery to reflect the pre-pregnancy haemodynamic state. Cardiac output was measured by continuous wave Doppler at the aortic valve. Interventricular septum thickness was determined by M- mode echocardiography and ventricular diastolic function by assessing flow at the mitral valve with Doppler recording. Cardiac output showed an increase of 32.9% at 36 weeks and maintained till 40 weeks of gestation. Heart rate increased from 79 ± 6 to 96 ± 8 beats/min at 36 weeks. Stroke volume increased by 16.4 % at 40 weeks of gestation when compared to the baseline
    value. Systolic and diastolic blood pressure did not appreciably change but showed a lower reading during the mid-trimester period. Early inflow velocity of left ventricle did not show a rise while peak atrial velocity showed an increasing trend; thus the ratio of early inflow to peak atrial transport showed a declining trend from early pregnancy to term. End diastolic dimension of left ventricle and interventricular septum thickness showed an increased value at term. Uncomplicated hyperemesis gravidarum did not alter the haemodynamic changes throughout pregnancy and concur with established data for normal pregnancy.
    Matched MeSH terms: Heart Ventricles
  6. Muhamad, N.A.R., Tuan Hairulnizam, T.K., Jessie, D.H., Rashidi, A., Jeewadas, B., Isa, A.Z., et al.
    MyJurnal
    Flying feather is a traditional street weapon, which is believed to be originated from Philippine. It is a famous weapon in Tawau, Sabah, shot within short distance and being used with the aim to debilitate the victims. Some may even apply poison at the tip of the weapon. We report two cases of severe chest injuries in resulting from flying feathers. Case 1, a 25-year old man sustained left sided hemothorax with anterior right ventricle injury. He underwent thoracotomy and was discharged well. Case 2, a 40-year old man, presented to emergency department with no signs of life, sustained penetrating injury to the left second intercostal muscle, the pericardium and the anterior wall of the right ventricle adjacent to the interventricular septum. These cases highlight the severity spectrum of cardiac injury resulting from flying feathers.
    Matched MeSH terms: Heart Ventricles
  7. Abdulrahman Al Aizary, Faiz Daud
    Int J Public Health Res, 2016;6(1):700-706.
    MyJurnal
    Introduction Prolonged mechanical ventilation among cardiac surgery patient has been
    found to be correlated with negative clinical outcome and increased
    healthcare resources utilization. Prolonged mechanical ventilation (PMV)
    was defined as the accumulative duration of 24 hours or more of
    postoperative endotracheal intubation starting from transfer of the patient to
    cardiac ICU. This study is aimed to identify the risk factors preoperative,
    intra operative and postoperative for prolonged ventilation among cardiac
    patients in AL-Thawra Modern General Hospital (TMGH).

    Methods Observational study design was conducted during a two-month period (from
    1 August 2014 to 30 September 2014). It was among 70 patients who were
    admitted to cardiac surgery intensive care unit in Al-Thawra Modern General
    Hospital and selected by convenient sampling. The soci-demographic
    characteristic and clinical patient data were collected using short
    questionnaire developed by researcher. All patients had the same anesthetic
    and postoperative management. Statistical analysis was performed with SPSS
    version 20 and using bivariate analysis and multivariate logistic regression.
    The p-value of < 0.05 was found to be statistically significant.

    Results Incidence of prolonged mechanical ventilator post cardiac surgery was 37.1%
    (26/70) through bivariate analysis, multivariate logistic regression. Low
    Ejection fraction of Left Ventricle was inversely related to mechanical
    ventilation time (AOR= 0.872) with 95% confidence interval [0.790 - 0.963],
    hemodynamic instability were associated with prolonged mechanical
    ventilation time (AOR=16.35) with 95% confidence interval [2.558 -
    104.556].

    Conclusion Low ejection fraction of Left Ventricle and Hemodynamic Instability post
    operation were identified risk factors for prolonged mechanical ventilation
    post cardiac surgery.
    Matched MeSH terms: Heart Ventricles
  8. Leong MC, Ahmed Alhassan AA, Sivalingam S, Alwi M
    Ann Thorac Surg, 2019 09;108(3):813-819.
    PMID: 30998905 DOI: 10.1016/j.athoracsur.2019.03.045
    BACKGROUND: Ductal stenting is performed to retrain involuted left ventricles (LVs) in patients with d-transposition of the great arteries and intact ventricular septum (TGA-IVS). However, its efficacy is largely unknown. This study aimed to determine the safety and efficacy of ductal stenting in retraining of the involuted LV in patients with TGA-IVS.

    METHODS: This was a single-center, retrospective study. Echocardiographic assessment of the LV geometry, mass, and free wall thickness was performed before stenting and before the arterial switch operation. Patients then underwent the arterial switch operation, and the postoperative outcomes were reviewed.

    RESULTS: There were 11 consecutive patients (male, 81.8%; mean age at stenting, 43.11 ± 18.19 days) with TGA-IVS with involuted LV who underwent LV retraining by ductal stenting from July 2013 to December 2017. Retraining by ductus stenting failed in 4 patients (36.3%). Two patients required pulmonary artery banding, and another 2 had an LV mass index of less than 35 g/m2. Patients in the successful group had improved LV mass index from 45.14 ± 17.91 to 81.86 ± 33.11g/m2 (p = 0.023) compared with 34.50 ± 10.47 to 20.50 ± 9.88 g/m2 (p = 0.169) and improved LV geometry after ductal stenting. The failed group was associated with an increased need for extracorporeal support (14.5% vs 50%, p = 0.012). An atrial septal defect-to-interatrial septum length ratio of more than 0.38 was associated with failed LV retraining.

    CONCLUSIONS: Ductal stenting is an effective method to retrain the involuted LV in TGA-IVS. A large atrial septal defect (atrial septal defect-to-interatrial septum length ratio >0.38) was associated with poor response to LV retraining.

    Matched MeSH terms: Heart Ventricles/surgery
  9. Chinitz L, Ritter P, Khelae SK, Iacopino S, Garweg C, Grazia-Bongiorni M, et al.
    Heart Rhythm, 2018 09;15(9):1363-1371.
    PMID: 29758405 DOI: 10.1016/j.hrthm.2018.05.004
    BACKGROUND: Micra is a leadless pacemaker that is implanted in the right ventricle and provides rate response via a 3-axis accelerometer (ACC). Custom software was developed to detect atrial contraction using the ACC enabling atrioventricular (AV) synchronous pacing.

    OBJECTIVE: The purpose of this study was to sense atrial contractions from the Micra ACC signal and provide AV synchronous pacing.

    METHODS: The Micra Accelerometer Sensor Sub-Study (MASS) and MASS2 early feasibility studies showed intracardiac accelerations related to atrial contraction can be measured via ACC in the Micra leadless pacemaker. The Micra Atrial TRacking Using A Ventricular AccELerometer (MARVEL) study was a prospective multicenter study designed to characterize the closed-loop performance of an AV synchronous algorithm downloaded into previously implanted Micra devices. Atrioventricular synchrony (AVS) was measured during 30 minutes of rest and during VVI pacing. AVS was defined as a P wave visible on surface ECG followed by a ventricular event <300 ms.

    RESULTS: A total of 64 patients completed the MARVEL study procedure at 12 centers in 9 countries. Patients were implanted with a Micra for a median of 6.0 months (range 0-41.4). High-degree AV block was present in 33 patients, whereas 31 had predominantly intrinsic conduction during the study. Average AVS during AV algorithm pacing was 87.0% (95% confidence interval 81.8%-90.9%), 80.0% in high-degree block patients and 94.4% in patients with intrinsic conduction. AVS was significantly greater (P

    Matched MeSH terms: Heart Ventricles/physiopathology*
  10. Crossley GH, Biffi M, Johnson B, Lin A, Gras D, Hussin A, et al.
    Heart Rhythm, 2015 Apr;12(4):751-8.
    PMID: 25533587 DOI: 10.1016/j.hrthm.2014.12.019
    The Medtronic Attain Performa quadripolar leads provide 16 pacing vectors with steroid on every electrode. This includes a short bipolar configuration between the middle 2 electrodes.
    Matched MeSH terms: Heart Ventricles/physiopathology
  11. Yee R, Gadler F, Hussin A, Bin Omar R, Khaykin Y, Verma A, et al.
    Heart Rhythm, 2014 Jul;11(7):1150-5.
    PMID: 24801899 DOI: 10.1016/j.hrthm.2014.04.020
    Left ventricular (LV) lead implantation for cardiac resynchronization therapy (CRT) is associated with lead dislodgement rates ranging from 3% to 10%, and some implant approaches to prevent dislodgement may contribute to suboptimal CRT response. We report our early human experience with an LV lead with a side helix for active fixation to the coronary vein wall.
    Matched MeSH terms: Heart Ventricles/physiopathology
  12. Riyadi S, Mustafa MM, Hussain A, Maskon O, Nor IF
    Adv Exp Med Biol, 2011;696:461-9.
    PMID: 21431586 DOI: 10.1007/978-1-4419-7046-6_46
    Left ventricular motion estimation is very important for diagnosing cardiac abnormality. One of the popular techniques, optical flow technique, promises useful results for motion quantification. However, optical flow technique often failed to provide smooth vector field due to the complexity of cardiac motion and the presence of speckle noise. This chapter proposed a new filtering technique, called quasi-Gaussian discrete cosine transform (QGDCT)-based filter, to enhance the optical flow field for myocardial motion estimation. Even though Gaussian filter and DCT concept have been implemented in other previous researches, this filter introduces a different approach of Gaussian filter model based on high frequency properties of cosine function. The QGDCT is a customized quasi discrete Gaussian filter in which its coefficients are derived from a selected two-dimensional DCT. This filter was implemented before and after the computation of optical flow to reduce the speckle noise and to improve the flow field smoothness, respectively. The algorithm was first validated on synthetic echocardiography image that simulates a contracting myocardium motion. Subsequently, this method was also implemented on clinical echocardiography images. To evaluate the performance of the technique, several quantitative measurements such as magnitude error, angular error, and standard error of measurement are computed and analyzed. The final motion estimation results were in good agreement with the physician manual interpretation.
    Matched MeSH terms: Heart Ventricles/ultrasonography*
  13. Chan BT, Lim E, Chee KH, Abu Osman NA
    Comput Biol Med, 2013 May;43(4):377-85.
    PMID: 23428371 DOI: 10.1016/j.compbiomed.2013.01.013
    The heart is a sophisticated functional organ that plays a crucial role in the blood circulatory system. Hemodynamics within the heart chamber can be indicative of exert cardiac health. Due to the limitations of current cardiac imaging modalities, computational fluid dynamics (CFD) have been widely used for the purposes of cardiac function assessment and heart disease diagnosis, as they provide detailed insights into the cardiac flow field. An understanding of ventricular hemodynamics and pathological severities can be gained through studies that employ the CFD method. In this research the hemodynamics of two common myocardial diseases, dilated cardiomyopathy (DCM) and myocardial infarction (MI) were investigated, during both the filling phase and the whole cardiac cycle, through a prescribed geometry and fluid structure interaction (FSI) approach. The results of the research indicated that early stage disease identification and the improvement of cardiac assisting devices and therapeutic procedures can be facilitated through the use of the CFD method.
    Matched MeSH terms: Heart Ventricles/physiopathology
  14. Garweg C, Khelae SK, Steinwender C, Chan JYS, Ritter P, Johansen JB, et al.
    Heart Rhythm, 2020 12;17(12):2037-2045.
    PMID: 32717315 DOI: 10.1016/j.hrthm.2020.07.024
    BACKGROUND: The MARVEL (Micra Atrial TRacking Using a Ventricular AccELerometer) 2 study assessed the efficacy of atrioventricular (AV) synchronous pacing with a Micra leadless pacemaker. Average atrioventricular synchrony (AVS) was 89.2%. Previously, low amplitude of the Micra-sensed atrial signal (A4) was observed to be a factor of low AVS.

    OBJECTIVE: The purpose of this study was to identify predictors of A4 amplitude and high AVS.

    METHODS: We analyzed 64 patients enrolled in MARVEL 2 who had visible P waves on electrocardiogram for assessing A4 amplitude and 40 patients with third-degree AV block for assessing AVS at rest. High AVS was defined as >90% correct atrial-triggered ventricular pacing. The association between clinical factors and echocardiographic parameters with A4 amplitude was investigated using a multivariable model with lasso variable selection. Variables associated with A4 amplitude together with premature ventricular contraction burden, sinus rate, and sinus rate variability (standard deviation of successive differences of P-P intervals [SDSD]) were assessed for association with AVS.

    RESULTS: In univariate analysis, low A4 amplitude was inversely related to atrial function assessed by E/A ratio and e'/a' ratio, and was directly related to atrial contraction excursion (ACE) and atrial strain (Ɛa) on echocardiography (all P ≤.05). The multivariable lasso regression model found coronary artery bypass graft history, E/A ratio, ACE, and Ɛa were associated with low A4 amplitude. E/A ratio and SDSD were multivariable predictors of high AVS, with >90% probability if E/A <0.94 and SDSD <5 bpm.

    CONCLUSION: Clinical parameters and echocardiographic markers of atrial function are associated with A4 signal amplitude. High AVS can be predicted by E/A ratio <0.94 and low sinus rate variability at rest.

    Matched MeSH terms: Heart Ventricles/physiopathology*
  15. Aslannif R, Suraya K, Koh HB, Tey YS, Tan KL, Tham CH, et al.
    Med J Malaysia, 2019 12;74(6):521-526.
    PMID: 31929479
    INTRODUCTION: Apical Hypertrophic Cardiomyopathy (Apical HCM) is an uncommon variant of hypertrophic cardiomyopathy, but it is relatively more common in Asian countries. This is a retrospective, non-randomised, single centre study of patients with Apical HCM focusing on their diastolic dysfunction grading, echocardiographic parameters and electrocardiograms (ECG).

    METHODS: All Apical HCM patients coming for clinic visits at the Institut Jantung Negara from September 2017 to September 2018 were included. We assessed their echocardiography images, grade their diastolic function and reviewed their ECG on presentation.

    RESULTS: Fifty patient were included, 82% (n=41) were males and 18% (n=9) females. The diastolic function grading of 37 (74%) patients were able to be determined using the updated 2016 American Society of Echocardiography (ASE) diastolic guidelines. Fifty percent (n=25) had the typical ace-ofspades shape left ventricle (LV) appearance in diastole and 12% (n=6) had apical pouch. All patients had T inversion in the anterior leads of their ECG, and only 52% (n=26) fulfilled the ECG left ventricular hypertrophy (LVH) criteria. Majority of our patients presented with symptoms of chest pain (52%, n=26) and dyspnoea (42%, n=21).

    CONCLUSION: The updated 2016 ASE guideline makes it easier to evaluate LV diastolic function in most patients with Apical HCM. It also helps in elucidating the aetiology of dyspnoea, based on left atrial pressure. Clinicians should have a high index of suspicion for Apical HCM when faced with deep T inversion on ECG, in addition to a thick LV apex with an aceof- spades appearance during diastole.

    Matched MeSH terms: Heart Ventricles/physiopathology*
  16. Alwi M
    Catheter Cardiovasc Interv, 2006 May;67(5):679-86.
    PMID: 16572430 DOI: 10.1002/ccd.20672
    Pulmonary atresia with intact ventricular septum (PAIVS) is a disease with remarkable morphologic variability, affecting not only the pulmonary valve but also the tricuspid valve, the RV cavity and coronary arteries. With advances in interventional techniques and congenital heart surgery, the management of PAIVS continues to evolve. This review is an attempt at providing a practical approach to the management of this disease. The basis of our approach is morphologic classification as derived from echocardiography and angiography. Group A, patients with good sized RV and membranous atresia, the primary procedure at presentation is radiofrequency (RF) valvotomy. Often it is the only procedure required in this group with the most favourable outcome. Patients with severely hypoplastic RV (Group C) are managed along the lines of hearts with single ventricle physiology. The treatment at presentation is patent ductus arteriosus (PDA) stenting with balloon atrial septostomy or conventional modified Blalock Taussig (BT) shunt. Bidirectional Glenn shunt may be done 6-12 months later followed by Fontan completion after a suitable interval. Patients in Group B, the intermediate group, are those with borderline RV size, usually with attenuated trabecular component but well developed infundibulum. The treatment at presentation is RF valvotomy and PDA stenting +/- balloon atrial septostomy. Surgical re-interventions are not uncommonly required viz. bidirectional Glenn shunt when the RV fails to grow adequately (11/2 - ventricle repair) and right ventricular outflow tract (RVOT) reconstruction for subvalvar obstruction or small pulmonary annulus. Catheter based interventions viz. repeat balloon dilatation or device closure of patent foramen ovale (PFO) may also be required in some patients.
    Matched MeSH terms: Heart Ventricles/pathology*
  17. Toh KW, Nadesan K, Sie MY, Vijeyasingam R, Tan PS
    Anesth Analg, 2004 Aug;99(2):350-2, table of contents.
    PMID: 15271703
    Arrhythmogenic right ventricular dysplasia is an inherited disease causing fatty replacement of heart tissue. This disease often presents as T-wave inversion in the anterior leads of the electrocardiogram (ECG) with life-threatening ventricular arrhythmias. In older patients, progressive right and left ventricular failure can develop. This is a case report of postoperative death occurring in a 59-yr-old woman with undiagnosed arrhythmogenic right ventricular dysplasia after hepatic cystectomy. The patient had T-wave inversion in the inferior ECG leads and no history of arrhythmias. During general anesthesia, cardiovascular collapse occurred in the absence of arrhythmias that was unresponsive to resuscitation.
    Matched MeSH terms: Heart Ventricles/pathology
  18. Wong AR, Suhaimi H, Ridzuan MA, Rizal MM, Saedah A
    Singapore Med J, 2009 Oct;50(10):e358-61.
    PMID: 19907875
    We present two infants whose endovascular lines were accidentally cut or fractured, and had to be retrieved via transcatheter means in the cardiac catheterisation laboratory. The first case was a two-month-old infant with transposition of the great arteries, requiring an emergency balloon atrial septostomy. An indwelling vascular catheter that was placed in the right femoral vein was accidentally cut and had migrated into the inferior vena cava, before being retrieved. The second case was a one-week-old neonate who presented with pneumonia at birth, and had a long intravenous catheter placed in the left saphenous vein, which became fractured, and subsequently migrated into the heart. This case presented as a pulmonary embolus with haemodynamic instability, as the catheter had partially obstructed the right ventricular outflow tract. This was later retrieved via transcatheter means.
    Matched MeSH terms: Heart Ventricles/pathology
  19. Subramaniam K, Siew SF, Mahmood MS
    Malays J Pathol, 2019 Apr;41(1):51-54.
    PMID: 31025638
    Spontaneous coronary artery dissection is a rare event and commonly associated with pregnancy and female gender. This condition can reduce or completely obstruct the blood flow to the heart, causing a myocardial ischaemia, abnormalities in heart rhythm or sudden death. We present a case of a 28-year-old Indian male with no previous medical illness who complained sudden onset of chest pain prior to his death. Autopsy revealed a left anterior descending coronary artery dissection associated with plaque rupture. The anterior wall of left ventricle showed contraction band necrosis. There was also atheroma present in the right coronary artery which was insignificant. Histologically, dissection was associated with atherosclerosis. There was no evidence of vasculitis. The cause of death was given as coronary artery dissection due to coronary artery atherosclerosis.
    Matched MeSH terms: Heart Ventricles
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links