SIGNIFICANCE: The LC/ESI-MS/MS prazosin method was highly sensitive and selective. Bedside sampling reduced the orthostatic hypotension incidence and subject dropout rate.
METHODS: After sample preparation, prazosin and terazosin (IS) were detected on mass spectrometer operating in multiple reaction monitoring mode using positive ionization. Mobile phase flow rate was set at 0.40 mL/min with sample run time of 1.75 min. The bioanalytical method was validated as per EMEA and FDA guidelines. Bedside sampling was performed in bioequivalence study for the first 4 h after dosing. The three primary pharmacokinetic parameters, Cmax, AUC0-t and AUC0-∞ and 90% confidence interval were determined.
RESULTS: The small injection volume of 1 μL minimized instrumentation contamination and prolonged the analytical column lifespan. Linearity was obtained between 0.5 and 30.0 ng/mL, with coefficient of determination, r2 ≥ 0.99. The mean extraction recovery of prazosin and IS was >92%, with precision value (CV, %) ≤ 10.3%. Only two orthostatic hypotension adverse events were reported. The two prazosin formulations were found to be bioequivalent.
CONCLUSION: The LC/ESI-MS/MS method has shown robustness and reliability exemplified by the incurred sample re-analysis result. Bedside sampling should be proposed for bioequivalence or pharmacokinetic studies of drugs demonstrating adverse event of orthostatic hypotension.
MATERIALS AND METHODS: In this trial, a total of 56 eligible subjects were randomly assigned to the fasting group and the postprandial group. The two groups were given 250 mg of the test and reference preparation, respectively. Liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was applied to determine the plasma concentration of cefalexin. PhoenixWinNonlin software (V7.0) was used to calculate the pharmacokinetic parameters of cefalexin using the non-compartmental model (NCA), and the bioequivalence and safety results were calculated by SAS (V9.4) software.
RESULTS: The main pharmacokinetic parameters of the test and reference preparations were as follows, the fasting group: Cmax 12.59 ± 2.65 μg/mL, 12.72 ± 2.28 μg/mL; AUC0-8h 20.43 ± 3.47 h×μg/mL, 20.66 ± 3.38 h×μg/mL; AUC0-∞ 20.77 ± 3.53 h×μg/mL, 21.02 ± 3.45 h×μg/mL; the postprandial group: Cmax 5.25 ± 0.94 μg/mL, 5.23 ± 0.80 μg/mL; AUC0-10h 16.92 ± 2.03 h×μg/mL, 17.09 ± 2.31 h×μg/mL; AUC0-∞ 17.33 ± 2.09 h×μg/mL, 17.67 ± 2.45 h×μg/mL.
CONCLUSION: The 90% confidence intervals of geometric mean ratios of test preparation and reference preparation were calculated, and the 90% confidence intervals of geometric mean ratios of Cmax, AUC0-10h, and AUC0-∞ were within the 80.00% ~ 125.00% range in both groups. Both Cmax and AUC met the pre-determined criteria for assuming bioequivalence. The test and reference products were bioequivalent after administration under fasting as well as under fed conditions in healthy Chinese subjects. This study may suggest that successful generic versions of cefalexin not only guarantee the market supply of such drugs but can also improve the safety and effectiveness and quality controllability of cefalexin through a new process and a new drug composition ratio.
METHOD: The effects of organic modifiers in mobile phase, protein precipitation agent to plasma sample ratio, and light on montelukast stability in unprocessed and processed human plasma, were evaluated. Validation was conducted in accordance with European Medicines Agency Guideline on bioanalytical method validation.
RESULTS: No interference peak was observed when acetonitrile was used as an organic modifier. Acetonitrile to plasma ratio of 4:1 produced clean plasma sample. Approximately 3 % of cis isomer was detected in unprocessed plasma samples while 21 % of cis isomer was detected in processed plasma samples after exposing to fluorescent light for 24h. The standard calibration curve was linear over 3.00-1200.00 ng/mL. All method validation parameters were within the acceptance criteria.
CONCLUSION: The validated method was successfully applied to a bioequivalence study of two montelukast formulations involving 24 healthy Malaysian volunteers. The light stability of a light sensitive drug in unprocessed and processed human plasma samples should be studied prior to pharmacokinetic/bioequivalence studies. Measures could then be taken to protect the analyte in human plasma from light degradation.
METHOD: This is a single-center, single-dose, open-label, randomized, 2-treatment, 2-sequence and 2-period crossover study with a washout period of 7 days. Paracetamol/Orphenadrine tablets were administered after a 10-h fast. Blood samples for pharmacokinetic analysis were collected at scheduled time intervals prior to and up to 72 h after dosing. Blood samples were centrifuged, and separated plasma were kept frozen (- 15 °C to - 25 °C) until analysis. Plasma concentrations of orphenadrine and paracetamol were quantified using liquid-chromatography-tandem mass spectrometer using diphenhydramine as internal standard. The pharmacokinetic parameters AUC0-∞, AUC0-t and Cmax were determined using plasma concentration time profile for both preparations. Bioequivalence was assessed according to the ASEAN guideline acceptance criteria for bioequivalence which is the 90% confidence intervals of AUC0-∞, AUC0-t and Cmax ratio must be within the range of 80.00-125.00%.
RESULTS: There were 28 healthy subjects enrolled, and 27 subjects completed this trial. There were no significant differences observed between the AUC0-∞, AUC0-t and Cmax of both test and reference preparations in fasted condition. The 90% confidence intervals for the ratio of AUC0-t (100.92-111.27%), AUC0-∞ (96.94-108.08%) and Cmax (100.11-112.50%) for orphenadrine (n = 25); and AUC0-t (94.29-101.83%), AUC0-∞ (94.77-101.68%) and Cmax (87.12-101.20%) for paracetamol (n = 27) for test preparation over reference preparation were all within acceptable bioequivalence range of 80.00-125.00%.
CONCLUSION: The test preparation is bioequivalent to the reference preparation and can be used interchangeably.
TRIAL REGISTRATION: NMRR- 17-1266-36,001; registered and approved on 12 September 2017.
MATERIALS AND METHODS: This is a single-center, single-dose, open-label, randomized, 2-treatment, 2-sequence and 2- period crossover study with a washout period of 7 days. All 28 adult male subjects were required to fast for at least 10 hours prior to drug administration and they were given access to water ad libitum during this period. Thirty minutes prior to dosing, all subjects were served with a standardized high-fat and high-calorie breakfast with a total calorie of 1000 kcal which was in accordance to the EMA Guideline on the Investigation of Bioequivalence. Subsequently, subjects were administered either the test or reference preparation with 240mL of plain water in the first trial period. During the second trial period, they received the alternate preparation. Plasma levels of glibenclamide and metformin were analysed separately using two different high performance liquid chromatography methods.
RESULTS: The 90% confidence interval (CI) for the ratio of the AUC0-t, AUC0-∞, and Cmax of the test preparation over those of the reference preparation were 0.9693-1.0739, 0.9598- 1.0561 and 0.9220 - 1.0642 respectively. Throughout the study period, no serious drug reaction was observed. However, a total of 26 adverse events (AE)/side effects were reported, including 24 that were definitely related to the study drugs, namely giddiness (n=17), while diarrheoa (n=3), headache (n=2) and excessive hunger (n=2) were less commonly reported by the subjects.
CONCLUSION: It can be concluded that the test preparation is bioequivalent to the reference preparation.
RECENT FINDINGS: The quality of multiple generic DAAs has been shown to be bioequivalent to innovator formulations, with generic versions achieving high cure rates in real-world settings. Although published materials are limited, there is expanding experience with local pilot and national treatment programs which are largely being funded by national governments and other institutions.
SUMMARY: Countries and other public health stakeholders are recognizing the need to scale up HCV diagnosis and treatment programs using generic DAAs. However, local pilot or national treatment programs need to be massively expanded to eliminate HCV in high-burden areas.
METHODS: This study was a cross-sectional nationwide survey targeting physicians from private medical centres in Malaysia. The survey was conducted using questionnaire having (i) background and demographic data of the physicians, volume of prescription in a day, stock of generic medicines in their hospital pharmacy etc. (ii) their knowledge about bioequivalence (iii) prescribing behavior (iv) physicians' knowledge of quality, safety and efficacy of generic medicines, and their cost (v) perceptions of physicians towards issues pertaining to generic medicines utilization.
RESULTS: A total of 263 questionnaires out of 735 were received, giving a response rate of 35.8%. Of the respondents, 214 (81.4%) were male and 49 (18.6%) were females. The majority of the participants were in the age range of 41-50 years and comprised 49.0% of the respondents. Only 2.3% of physicians were aware of the regulatory limits of bioequivalence standards in Malaysia. Of the respondents, 23.2% agreed that they 'always' write their prescriptions using originator product name whereas 50.2% do it 'usually'. A number of significant associations were found between their knowledge, perceptions about generic medicines and their demographic characteristics.
CONCLUSIONS: The majority of the physicians from private medical centres in Malaysia had negative perceptions about safety, quality and the efficacy of generic medicines. These negative perceptions could be the cause of the limited use of generic medicines in the private medical centres. Therefore, in order to facilitate their use, it is recommended that the physicians need to be reassured and educated about the drug regulatory authority approval system of generic medicines with regard to their bioequivalence, quality, efficacy and safety. Apart from the policy on generic substitution, it would also be recommended to have a national medicine pricing policy, which controls drug prices, in both the public and private sector. These efforts are worthwhile to reduce the drug expenditure and improve the medicine affordability in Malaysia.