Affiliations 

  • 1 Bioxis Sdn. Bhd. Plot 301 (b), Jalan Perindustrian Bukit Minyak 8, Taman Perindustrian Bukit Minyak, 14100 Simpang Ampat, Penang, Malaysia. Electronic address: lohonnkitgabriel@yahoo.com
  • 2 Bioxis Sdn. Bhd. Plot 301 (b), Jalan Perindustrian Bukit Minyak 8, Taman Perindustrian Bukit Minyak, 14100 Simpang Ampat, Penang, Malaysia. Electronic address: wongyl4985@yahoo.com.sg
  • 3 Bioxis Sdn. Bhd. Plot 301 (b), Jalan Perindustrian Bukit Minyak 8, Taman Perindustrian Bukit Minyak, 14100 Simpang Ampat, Penang, Malaysia. Electronic address: yvonne_usm@yahoo.com
  • 4 Clinical Research Centre, Hospital Pulau Pinang, Jalan Residensi, 10990 Georgetown, Penang, Malaysia. Electronic address: chinapple1021@gmail.com
  • 5 Clinical Research Centre, Hospital Pulau Pinang, Jalan Residensi, 10990 Georgetown, Penang, Malaysia. Electronic address: nrshing@gmail.com
  • 6 School of Pharmaceutical Sciences, Universiti Sains Malaysia, 11800 Minden, Penang, Malaysia. Electronic address: chongyew@usm.my
  • 7 School of Pharmaceutical Sciences, Universiti Sains Malaysia, 11800 Minden, Penang, Malaysia. Electronic address: kkpeh@usm.my
J Pharm Biomed Anal, 2021 Feb 05;194:113758.
PMID: 33248861 DOI: 10.1016/j.jpba.2020.113758

Abstract

A simple, rapid, sensitive, and reproducible LC-MS/MS method was developed for simultaneous quantification of flavoxate and 3-methyl-flavone-8-carboxylic (MFCA) in human plasma, using diphenhydramine HCl as internal standard (IS). The chromatographic separation was achieved using Agilent Poroshell 120 EC-C18 - Fast LC column (100 × 2.1mmID, 2.7 μm) fitted with UHPLC Guard Poroshell 120 EC-C18 (5 × 2.1 mmID, 2.7 μm). The mobile phase consisted of 0.1 % v/v formic acid and acetonitrile (30:70, v/v) run at a flow rate of 0.40 mL/min. The standard calibration curve was linear over the concentration range of 2.00 - 2,000.31 ng/mL and 240.00 - 24,000.04 ng/mL for flavoxate and MFCA. For flavoxate and MFCA, the within-run precision was 0.81-6.67 % and 1.68-4.37 %, while accuracy was 100.21-108.25 % and 103.99-110.28 %. The between-run precision was 2.01-9.14 % and 2.31-11.11 %, and accuracy was 96.09-103.33 % and 102.37-109.52 %. The extended run precision was 7.78-11.04 % and 2.22-3.33 %, while accuracy was 100.72-101.88 % and 102.34-105.60 %. Flavoxate and MFCA in plasma were stable 4 h at bench top (short term), 24 h in autosampler and instrumentation room (post-preparative), after 7 freeze-thaw cycles, and 89 days in the freezer. Both analytes and IS stock solutions were stable for 31 days when kept at room temperature (25 ± 4 °C) and refrigerated (2-8 °C). The validated method was successfully applied to a bioequivalence study of two flavoxate formulations involving 24 healthy volunteers.

* Title and MeSH Headings from MEDLINE®/PubMed®, a database of the U.S. National Library of Medicine.