Displaying publications 1 - 20 of 31 in total

Abstract:
Sort:
  1. Jin-Poi T, Shatriah I, Ng SL, Zurkurnai Y, Yunus R
    JAMA Ophthalmol, 2013 Feb;131(2):263-5.
    PMID: 23411903 DOI: 10.1001/jamaophthalmol.2013.587
    Matched MeSH terms: Visual Acuity/physiology
  2. Wong EY, Chew PT, Chee CK, Wong JS
    Am J Ophthalmol, 1997 Dec;124(6):797-804.
    PMID: 9402826
    PURPOSE: To evaluate the effectiveness and safety of diode laser contact transscleral cyclophotocoagulation in Asian patients with refractory glaucoma by lower energy settings with an innovative probe featuring a glass ball tip that focused the laser beam onto the ciliary body.

    METHODS: This prospective clinical study included consecutive Asian patients with dark irides and confirmed for glaucoma. Only one eye of each patient was treated. Diode laser contact transscleral cyclophotocoagulation treatment was performed with the center of the probe placed 1.5 mm behind the limbus. About 30 pulses of 810-mm laser radiation (power, 1.8 to 2.0 W; duration, 0.3 to 0.5 second) were applied around the eye. Patients were examined at fixed postoperative intervals. Intraocular pressure levels and postoperative complications were recorded. The relation between patient and disease characteristics, total laser energy delivered, and intraocular pressure effects were analyzed.

    RESULTS: Thirty-three patients were studied, with a mean follow-up period of 9.4 months. An average 56% of patients showed a 30% or greater drop in intraocular pressure. About 38% of patients achieved sustained intraocular pressure lowering to below 22 mm Hg at 18 months. Complications were few and included transient hypotony and iritis.

    CONCLUSIONS: In Asian patients with refractory glaucoma or painful glaucomatous eyes with poor visual acuity (defined for this study as worse than 20/200), low-energy-setting diode laser contact transscleral cyclophotocoagulation by means of the glass ball probe is relatively effective and safe.

    Matched MeSH terms: Visual Acuity/physiology
  3. Shatriah I, Adlina AR, Alshaarawi S, Wan-Hitam WH
    Pediatr Neurol, 2012 May;46(5):293-7.
    PMID: 22520350 DOI: 10.1016/j.pediatrneurol.2012.02.020
    Limited data are available on optic neuritis in Asian children. Clinical profiles tend to vary with different races. We aimed to determine the clinical manifestations, visual outcomes, and etiologies of optic neuritis in Malaysian children, and discuss the literature of optic neuritis in Asian children. A retrospective study involving 14 children with optic neuritis was performed at Hospital Universiti Sains Malaysia between July 2005 and January 2010 (follow-up, 18-60 months). Clinical features, laboratory results, possible etiologies, and visual acuity after 1 year were studied. Females were predominant (mean age at presentation, 11.1 years). All patients manifested bilateral involvement. Swollen optic discs were observed in 92.9% of eyes; 60.7% of patients demonstrated a visual acuity of 6/60 (or 20/200) or worse on presentation, whereas 14.3% remained at 6/60 (or 20/200) or worse, 1 year after their attack. Cecocentral scotoma comprised the most common visual field defect. Infection contributed to 50.0% of cases; 14.3% progressed to multiple sclerosis during follow-up, with no evidence of recurrent optic neuritis. The clinical profiles and etiologies of optic neuritis in Malay children differ slightly compared with other optic neuritis studies of Asian children. The frequency of progression to multiple sclerosis is relatively lower.
    Matched MeSH terms: Visual Acuity/physiology*
  4. Jones DJW, Harris JP, Butler LT, Vaux EC
    Physiol Behav, 2017 03 15;171:1-6.
    PMID: 28025091 DOI: 10.1016/j.physbeh.2016.12.029
    We investigated an effect of end-stage renal disease (ESRD) on the visual system by measuring the ability of 21 patients to perceive depth in the random dot stereograms and circles of the Randot Test. To control for other factors which might influence performance on the tests of stereopsis, patients were compared with healthy controls matched for age, years of education, IQ, and general cognitive ability. Vernier acuity (thought to reflect mainly central processing) and Landolt acuity (more sensitive to retinal and optical abnormalities) were also measured, but the study did not include a formal ophthalmological examination. All controls could perceive depth in random dot stereograms, whereas 9/21 patients could not. Patients who could perceive depth had worse stereoacuity than did their matched controls. The patient group as a whole had worse Vernier and Landolt acuities than the controls. The stereoblind patient subgroup had similar Vernier acuity to the stereoscopic subgroup, but worse Landolt acuity, and was more likely to have peripheral vascular disease. We conclude that ESRD had affected structures both within the eye, and within the visual brain. However, the similarity of Vernier acuity and difference of Landolt acuity in the stereoblind and stereoscopic patient subgroups suggest that the differences in stereoscopic ability arise from abnormalities in the eyes rather than in the brain.
    Matched MeSH terms: Visual Acuity/physiology
  5. Yong GY, Pan SW, Humayun Akhter F, Law TN, Toh TH
    PMID: 26693590 DOI: 10.1097/APO.0000000000000150
    PURPOSE: To study the demographic characteristics of ocular trauma in Central Sarawak and identify the determinant factors of poor visual outcome.

    DESIGN: A retrospective study of ocular trauma cases presenting at the referral hospital in 2013.

    METHODS: Patients were identified and recruited from hospital records. Those presenting for follow-up review were excluded. Case records were retrieved and reviewed after recruitment.

    RESULTS: We studied 168 patients with 179 ocular injuries, of which 44% were work related. Compared with non-work-related cases, work-related cases were more likely to be male [odds ratio (OR), 19.7; 95% confidence interval (CI), 2.6-150.9] and foreign (OR, 18.0; 95% CI, 2.3-142.0). Open globe injuries constituted a higher percentage of impaired visual acuity (VA) during the first visit: 84.6% compared with 18.1% for closed globe injuries (OR, 25.0; 95% CI, 5.3-118.4; P < 0.001). Of the open globe injuries, 61.5% worsened or showed no improvement in VA after 3 months compared with closed globe injuries (28.9%) (OR, 3.9; 95% CI, 1.2-12.7; P = 0.015). Of cases presenting 7 or more days after trauma, 76.9% worsened or showed no improvement in VA after 3 months compared with those presenting in less than 7 days (27.7%) (OR, 8.7; 95% CI, 2.3-33.0; P < 0.001). Among those with work-related injuries, 23.1% had used eye protective devices (EPDs).

    CONCLUSIONS: Ocular injuries in Central Sarawak were predominantly work related, occurring at industrial premises, and involving males and foreigners. Both open globe injuries and a delay in seeking treatment resulted in significantly poorer visual outcomes.

    Matched MeSH terms: Visual Acuity/physiology
  6. Yeow PT, Taylor SP
    Optom Vis Sci, 1991 Dec;68(12):930-41.
    PMID: 1787950
    Since their rapid introduction into the workplace visual display terminals (VDT's) have been the source of a number of studies aimed at detecting effects on office workers. The published studies have been either short-term or cross-sectional, with one exception. The results have shown varying degrees of relation but by not having a comparable control group all have been limited in their value. We set out to monitor at regular intervals over a 2-year period specific visual functions that have been reported to be affected by VDT usage, and to compare VDT and non-VDT users in the same office environment. By assessing the VDT operators from the time the systems were introduced we have an accurate baseline to work from when assessing change due to the introduction of the VDT.
    Matched MeSH terms: Visual Acuity/physiology*
  7. Shin HC, Subrayan V, Tajunisah I
    J Cataract Refract Surg, 2010 Aug;36(8):1289-95.
    PMID: 20656150 DOI: 10.1016/j.jcrs.2010.02.024
    PURPOSE: To evaluate changes in anterior chamber depth (ACD) and intraocular pressure (IOP) after phacoemulsification in eyes with occludable angles and compare the results with those in eyes with normal open angles.
    SETTING: Eye Clinic, Ipoh General Hospital, Ipoh, Perak, Malaysia.
    METHODS: Patients with nonglaucomatous eyes with open angles or with occludable angles were recruited. Ocular biometric measurements (ACD, axial length [AL], lens thickness and position) and IOP (tonometry) were performed preoperatively and 1 day and 1, 4, 9, and 12 weeks postoperatively.
    RESULTS: The open-angle group and occludable-angle group each comprised 35 patients. The occludable-angle group had a shallower ACD, shorter AL, thicker and relatively anterior lens position, and higher IOP preoperatively; postoperatively, there was a significant increase in ACD and a significant reduction in IOP (P
    Matched MeSH terms: Visual Acuity/physiology
  8. Peyman M, Tajunisah I, Loo A, Chuah KC, Subrayan V
    J Diabetes Complications, 2012 May-Jun;26(3):210-3.
    PMID: 22520399 DOI: 10.1016/j.jdiacomp.2012.03.019
    To correlate Heidelberg Retina Tomograph (HRT) derived macular edema (DME) index with severity of diabetic retinopathy and systemic factors. A total of 300 diabetic patients were recruited for the study for each of them a value for the macular edema index was obtained using the HRT II. Patients' age, gender, duration and type of diabetes mellitus, latest HbA1c result and presence or absence of co-morbid factors (hypertension, ischemic heart disease, nephropathy) were recorded together with the stage of diabetic retinopathy. These were correlated with DME. Out of 300 patients, HRT defined macula edema was seen in 68 patients (22.6%). There is a wider and higher range (95% percentile) of macula edema index in the severe non proliferative diabetic retinopathy (NPDR) group. Independent samples t test showed significant difference between the severe NPDR group and no DR group (p<0.001), mild NPDR group (p<0.05) and moderate NPDR group (p<0.05). A higher macula edema index was also found to have a low degree of correlation with more advanced stages of retinopathy (r=0.310; p<0.001). Also nephropathy showed a strong and significant correlation with DME. Hypertension had moderately significant correlation with DME. This study found no correlation between ischemic heart disease and DME. HRT derived scanning laser edema index is a reliable objective tool to evaluate diabetic retinopathy and systemic risk factors.
    Matched MeSH terms: Visual Acuity/physiology
  9. Lundström M, Goh PP, Henry Y, Salowi MA, Barry P, Manning S, et al.
    Ophthalmology, 2015 Jan;122(1):31-8.
    PMID: 25234011 DOI: 10.1016/j.ophtha.2014.07.047
    PURPOSE: The aim of this study was to describe changes over time in the indications and outcomes of cataract surgery and to discuss optimal timing for the surgery.
    DESIGN: Database study.
    PARTICIPANTS: Patients who had undergone cataract extraction in the Netherlands, Sweden, or Malaysia from 2008 through 2012.
    METHODS: We analyzed preoperative, surgical, and postoperative data from 2 databases: the European Registry of Quality Outcomes for Cataract and Refractive Surgery (EUREQUO) and the Malaysian National Cataract Registry. The EUREQUO contains complete data from the national cataract registries in the Netherlands and Sweden.
    MAIN OUTCOME MEASURES: Preoperative and postoperative corrected distance visual acuity, preoperative ocular comorbidity in the surgery eye, and capsule complications during surgery.
    RESULTS: There were substantial differences in indication for surgery between the 3 national data sets. The percentage of eyes with a preoperative best-corrected visual acuity of 20/200 or worse varied from 7.1% to 72%. In all 3 data sets, the visual thresholds for cataract surgery decreased over time by 6% to 28% of the baseline values. The frequency of capsule complications varied between the 3 data sets, from 1.1% to 3.7% in 2008 and from 0.6% to 2.7% in 2012. An increasing postoperative visual acuity was also seen for all 3 data sets. A high frequency of capsule complication was related significantly to poor preoperative visual acuity, and a high frequency of decreased visual acuity after surgery was related significantly to excellent preoperative visual acuity.
    CONCLUSIONS: The 5-year trend in all 3 national data sets showed decreasing visual thresholds for surgery, decreasing surgical complication rates, and increasing visual outcomes regardless of the initial preoperative visual level. Cataract surgery on eyes with poor preoperative visual acuity was related to surgical complications, and cataract surgery on eyes with excellent preoperative visual acuity was related to adverse visual results.
    Matched MeSH terms: Visual Acuity/physiology
  10. Sailoganathan A, Osuobeni EP, Siderov J
    Indian J Ophthalmol, 2018 05;66(5):634-640.
    PMID: 29676304 DOI: 10.4103/ijo.IJO_1074_17
    Purpose: The purpose of this study to develop and calibrate a new Hindi logarithm of the minimum angle of resolution (logMAR) visual acuity chart.

    Methods: A new Hindi visual acuity chart was designed to logMAR specifications using Hindi optotypes experimentally selected to have similar relative legibility under equivalent spherical and cylindrical defocus. The chart calibration study was carried out in a large clinical setup in India. Participants who were literate in English and Hindi participated in the study. Visual acuity was measured with the new Hindi logMAR chart and a modified ETDRS (m-ETDRS) logMAR chart. The method of presentation was randomized between the charts. Repeat visual acuity was measured on a subsequent day with a second version of the Hindi logMAR chart.

    Results: The Hindi logMAR chart correlated highly with the m-ETDRS logMAR chart (r2 = 0.92); however, the mean visual acuity difference (Hindi logMAR-m-ETDRS logMAR) was nearly one and half lines (0.13 logMAR, 95% confidence interval [CI] = ±0.15 logMAR). The Hindi logMAR chart also proved to be highly repeatable (r2 = 0.99; mean difference 0.005, 95% CI = ±0.04 logMAR).

    Conclusion: This study reports the first standardized visual acuity chart developed in Hindi incorporating equal letter legibility and logMAR chart design features. The Hindi logMAR visual acuity chart provides a valid and repeatable tool for the measurement of visual acuity in native Hindi language speakers. Future use of the new Hindi chart should incorporate an increase in optotype size of 0.13 logMAR.

    Matched MeSH terms: Visual Acuity/physiology*
  11. Sailoganathan A, Rou LX, Buja KA, Siderov J
    Optom Vis Sci, 2018 08;95(8):643-647.
    PMID: 30063661 DOI: 10.1097/OPX.0000000000001253
    SIGNIFICANCE: Vision charts comprising single Lea symbols surrounded by either flanking bars or flanking Lea symbols are available for measurement of visual acuity in children. However, the results obtained with such charts may not be interchangeable owing to potential differences in the crowding effect.

    PURPOSE: The purpose of this study was to compare habitual visual acuity in a sample of young children using two versions of the single Lea symbols charts with different crowding features.

    METHODS: Monocular habitual visual acuity was measured in a sample of 77 young children aged between 4 and 6 years using crowded Lea symbols charts with either flanking bars separated from the central symbol by 0.5 optotype width or flanking Lea optotypes separated from the central symbol by 1.0 optotype width.

    RESULTS: Mean visual acuity was higher (i.e., lower logarithm of the minimum angle of resolution) with the Lea symbols crowded using flanking optotypes, equivalent to about 1.5 optotype difference. Visual acuity measured with the two charts was significantly correlated; however, the 95% limits of agreement were larger than expected from repeatability studies using Lea symbols.

    CONCLUSIONS: Lea symbols with flanking optotypes resulted in higher visual acuity than the Lea symbols with flanking bars, probably as a result of differences in the crowding effect. The two charts showed insufficient agreement, and we do not recommend their use interchangeably. We recommend using the Lea symbols with flanking bars because of the closer flanker-target separation.

    Matched MeSH terms: Visual Acuity/physiology*
  12. Chew-Ean T, Othman K, Ghani SA, Shatriah I
    Can J Ophthalmol, 2018 10;53(5):e211-e212.
    PMID: 30340747 DOI: 10.1016/j.jcjo.2017.11.011
    Matched MeSH terms: Visual Acuity/physiology*
  13. Bashkaran K, Shatriah I, Zunaina E, Bakiah S, Sakinah Z
    Orbit, 2009;28(6):377-9.
    PMID: 19929663 DOI: 10.3109/01676830903104678
    Sinusitis is a rare cause of optic neuritis in children. This case illustrates bilateral optic neuritis in a 9-year-old child caused by pansinusitis. It demands an accurate diagnosis with a prompt management. A proper treatment of sinusitis is essential to prevent this complication.
    Matched MeSH terms: Visual Acuity/physiology
  14. Thevi T, Mimiwati Z, Reddy SC
    Nepal J Ophthalmol, 2012;4(2):263-70.
    PMID: 22864032 DOI: http://dx.doi.org/10.3126/nepjoph.v4i2.6542
    To determine the factors affecting the visual outcome in patients with open globe injuries of eye.
    Matched MeSH terms: Visual Acuity/physiology*
  15. Chong KL, Samsudin A, Keng TC, Kamalden TA, Ramli N
    J Glaucoma, 2017 Feb;26(2):e37-e40.
    PMID: 27599172 DOI: 10.1097/IJG.0000000000000542
    PURPOSE: To evaluate the effect of nocturnal intermittent peritoneal dialysis (NIPD) on intraocular pressure (IOP) and anterior segment optical coherence tomography (ASOCT) parameters. Systemic changes associated with NIPD were also analyzed.

    METHODS: Observational study. Nonglaucomatous patients on NIPD underwent systemic and ocular assessment including mean arterial pressure (MAP), body weight, serum osmolarity, visual acuity, IOP measurement, and ASOCT within 2 hours both before and after NIPD. The Zhongshan Angle Assessment Program (ZAAP) was used to measure ASOCT parameters including anterior chamber depth, anterior chamber width, anterior chamber area, anterior chamber volume, lens vault, angle opening distance, trabecular-iris space area, and angle recess area. T tests and Pearson correlation tests were performed with P<0.05 considered statistically significant.

    RESULTS: A total of 46 eyes from 46 patients were included in the analysis. There were statistically significant reductions in IOP (-1.8±0.6 mm Hg, P=0.003), MAP (-11.9±3.1 mm Hg, P<0.001), body weight (-0.7±2.8 kg, P<0.001), and serum osmolarity (-3.4±2.0 mOsm/L, P=0.002) after NIPD. All the ASOCT parameters did not have any statistically significant changes after NIPD. There were no statistically significant correlations between the changes in IOP, MAP, body weight, and serum osmolarity (all P>0.05).

    CONCLUSIONS: NIPD results in reductions in IOP, MAP, body weight, and serum osmolarity in nonglaucomatous patients.

    Matched MeSH terms: Visual Acuity/physiology
  16. Ismail SA, Sharanjeet-Kaur, Mutalib HA, Ngah NF
    J Optom, 2015 Oct-Dec;8(4):266-72.
    PMID: 26025808 DOI: 10.1016/j.optom.2015.04.001
    PURPOSE: To determine the influence of age and gender on macular sensitivity to light in healthy subjects of 4 age groups using the MP-1 microperimeter.
    METHODS: A prospective study was carried out on 50 healthy subjects (age range: 18-60 years) divided into 4 age groups; 18-30 years, 31-40 years, 41-50 years and 51-60 years. Full-threshold microperimetry of the central 10° of retina was performed utilizing 32 points with the MP-1. Macula area was divided into four quadrants, which were superior nasal (SN), inferior nasal (IN), inferior temporal (IT) and superior temporal (ST).
    RESULTS: Total mean sensitivity at 10° for age groups 18-30 years, 31-40 years, 41-50 years and 51-60 years were 19.46 ± 0.30, 19.40 ± 0.39, 19.47 ± 0.35 and 18.73 ± 0.75 (dB), respectively. There was a significant difference in total mean retinal sensitivity at 10° and at the four quadrants with age but not for gender. The retinal sensitivity was highest in the IT quadrant and lowest in the SN quadrant for all age groups. The linear regression analysis revealed that there was a 0.019 dB, 0.016 dB, 0.022 dB, 0.029 dB and 0.029 dB per year age-related decline in mean macular sensitivity within the central 10° diameter in the SN, IN, IT and ST quadrants respectively.
    CONCLUSION: Among normal healthy subjects, there was a linear decline in retinal light sensitivity with increasing age with the highest reduction in the superior nasal quadrant and lowest in the inferior temporal quadrant.
    Matched MeSH terms: Visual Acuity/physiology
  17. Mohd-Ali B, Mohammed Z, Norlaila M, Mohd-Fadzil N, Rohani CC, Mohidin N
    Clin Exp Optom, 2006 May;89(3):150-4.
    PMID: 16637969 DOI: 10.1111/j.1444-0938.2006.00033.x
    Down syndrome is a common chromosomal anomaly. Few reported studies make reference to the ocular status in Asian children with Down syndrome. The purpose of this study was to determine the visual and binocular status of a sample of Down syndrome children in Malaysia.
    Matched MeSH terms: Visual Acuity/physiology*
  18. Nadarajah G, Ratnalingam VH, Mohd Isa H
    Cornea, 2017 Apr;36(4):452-456.
    PMID: 27941383 DOI: 10.1097/ICO.0000000000001106
    PURPOSE: To evaluate graft stability and recurrence rate between fibrin glue and autologous blood in pterygium conjunctival autograft surgery.

    METHODS: A prospective, randomized, single-blinded clinical trial to assess the efficacy of autologous blood in place of fibrin glue in pterygium surgery. A total of 120 eyes of 111 patients were randomized according to pterygium morphology, to undergo pterygium surgery with autografting using either autologous blood or fibrin glue. All patients were operated by a single surgeon; 58 eyes were operated using fibrin glue and 62 eyes had a conjunctival autograft with autologous blood. Patients were seen on postoperative day 1, 1 week, 1 month, 6 months, and 1 year after surgery. Graft stability and pterygium recurrence were graded by an independent observer who was masked to the method of treatment.

    RESULTS: All 120 eyes completed the 1-year follow-up. Graft loss was seen only in the autologous blood group. Of the 62 eyes in this group, a total of 15 (24.2%) grafts dislodged. Recurrence was calculated after excluding grafts that were dislodged. Of the 105 patients, there were a total of 7 recurrences, 2 (3.4%) from the fibrin adhesive method and 5 (10.6%) from the autologous blood method. This was not statistically significant (P = 0.238).

    CONCLUSIONS: Autologous blood does not exhibit similar graft stability seen with fibrin glue. Although the recurrence rate may not be significant, careful patient selection and a standard method needs to be laid out before the use of this method is widely accepted.

    Matched MeSH terms: Visual Acuity/physiology
  19. Abdullah SN, Sanderson GF, Husni MA, Maddess T
    PMID: 32034583 DOI: 10.1007/s10633-020-09750-7
    PURPOSE: To compare two forms of perimetry that use large contrast-modulated grating stimuli in terms of: their relative diagnostic power, their independent diagnostic information about glaucoma and their utility for mfVEPs. We evaluated a contrast-threshold mfVEP in normal controls using the same stimuli as one of the tests.

    METHODS: We measured psychophysical contrast thresholds in one eye of 16 control subjects and 19 patients aged 67.8 ± 5.65 and 71.9 ± 7.15, respectively, (mean ± SD). Patients ranged in disease severity from suspects to severe glaucoma. We used the 17-region FDT-perimeter C20-threshold program and a custom 9-region test (R9) with similar visual field coverage. The R9 stimuli scaled their spatial frequencies with eccentricity and were modulated at lower temporal frequencies than C20 and thus did not display a clear spatial frequency-doubling (FD) appearance. Based on the overlapping areas of the stimuli, we transformed the C20 results to 9 measures for direct comparison with R9. We also compared mfVEP-based and psychophysical contrast thresholds in 26 younger (26.6 ± 7.3 y, mean ± SD) and 20 older normal control subjects (66.5 ± 7.3 y) control subjects using the R9 stimuli.

    RESULTS: The best intraclass correlations between R9/C20 thresholds were for the central and outer regions: 0.82 ± 0.05 (mean ± SD, p ≤ 0.0001). The areas under receiver operator characteristic plots for C20 and R9 were as high as 0.99 ± 0.012 (mean ± SE). Canonical correlation analysis (CCA) showed significant correlation (r = 0.638, p = 0.029) with 1 dimension of the C20 and R9 data, suggesting that the lower and higher temporal frequency tests probed the same neural mechanism(s). Low signal quality made the contrast-threshold mfVEPs non-viable. The resulting mfVEP thresholds were limited by noise to artificially high contrasts, which unlike the psychophysical versions, were not correlated with age.

    CONCLUSION: The lower temporal frequency R9 stimuli had similar diagnostic power to the FDT-C20 stimuli. CCA indicated the both stimuli drove similar neural mechanisms, possibly suggesting no advantage of FD stimuli for mfVEPs. Given that the contrast-threshold mfVEPs were non-viable, we used the present and published results to make recommendations for future mfVEP tests.

    Matched MeSH terms: Visual Acuity/physiology
  20. Mahmud I, Kelley T, Stowell C, Haripriya A, Boman A, Kossler I, et al.
    JAMA Ophthalmol, 2015 Nov;133(11):1247-52.
    PMID: 26291752 DOI: 10.1001/jamaophthalmol.2015.2810
    Aligning outcome measures for cataract surgery, one of the most frequently performed procedures globally, may facilitate international comparisons that can drive improvements in the outcomes most meaningful to patients.
    Matched MeSH terms: Visual Acuity/physiology
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links