Displaying publications 181 - 200 of 1500 in total

Abstract:
Sort:
  1. Jiemy WF, Heeringa P, Kamps JAAM, van der Laken CJ, Slart RHJA, Brouwer E
    Autoimmun Rev, 2018 Jul;17(7):715-726.
    PMID: 29729443 DOI: 10.1016/j.autrev.2018.02.006
    Macrophages are key players in the pathogenesis of large-vessel vasculitis (LVV) and may serve as a target for diagnostic imaging of LVV. The radiotracer, 18F-FDG has proven to be useful in the diagnosis of giant cell arteritis (GCA), a form of LVV. Although uptake of 18F-FDG is high in activated macrophages, it is not a specific radiotracer as its uptake is high in any proliferating cell and other activated immune cells resulting in high non-specific background radioactivity especially in aging and atherosclerotic vessels which dramatically lowers the diagnostic accuracy. Evidence also exists that the sensitivity of 18F-FDG PET drops in patients upon glucocorticoid treatment. Therefore, there is a clinical need for more specific radiotracers in imaging GCA to improve diagnostic accuracy. Numerous clinically established and newly developed macrophage targeted radiotracers for oncological and inflammatory diseases can potentially be utilized for LVV imaging. These tracers are more target specific and therefore may provide lower background radioactivity, higher diagnostic accuracy and the ability to assess treatment effectiveness. However, current knowledge regarding macrophage subsets in LVV lesions is limited. Further understanding regarding macrophage subsets in vasculitis lesion is needed for better selection of tracers and new targets for tracer development. This review summarizes the development of macrophage targeted tracers in the last decade and the potential application of macrophage targeted tracers currently used in other inflammatory diseases in imaging LVV.
    Matched MeSH terms: Tomography, Emission-Computed, Single-Photon; Positron-Emission Tomography
  2. Sulong S, Alias A, Johanabas F, Yap Abdullah J, Idris B
    J Craniofac Surg, 2019 8 14;31(1):46-50.
    PMID: 31403510 DOI: 10.1097/SCS.0000000000005810
    BACKGROUND: Craniosynostosis is a congenital defect that causes ≥1 suture to fuse prematurely. Cranial expansion surgery which consists of cranial vault reshaping with or without fronto-orbital advancement (FOA) is done to correct the skull to a more normal shape of the head as well as to increase the intracranial volume (ICV). Therefore, it is important to evaluate the changes of ICV after the surgery and the effect of surgery both clinically and radiologically.

    OBJECTIVE: The aim of this study is to evaluate the ICV in primary craniosynostosis patients after the cranial vault reshaping with or without FOA and to compare between syndromic and nonsyndromic synostosis group, to determine factors that associated with significant changes in the ICV postoperative, and to evaluate the resolution of copper beaten sign and improvement in neurodevelopmental delay after the surgery.

    METHODS: This is a prospective observational study of all primary craniosynostosis patients who underwent operation cranial vault reshaping with or without FOA in Hospital Kuala Lumpur from January 2017 until Jun 2018. The ICV preoperative and postoperative was measured using the 3D computed tomography (CT) imaging and analyzed. The demographic data, clinical and radiological findings were identified and analyzed.

    RESULTS: A total of 14 cases (6 males and 8 females) with 28 3D CT scans were identified. The mean age of patients was 23 months. Seven patients were having syndromic synostosis (4 Crouzon syndromes and 3 Apert syndromes) and 7 nonsyndromic synostosis. The mean preoperative ICV was 880 mL (range, 641-1234 mL), whereas the mean postoperative ICV was 1081 mL (range, 811-1385 mL). The difference was 201 mL which was statistically significant (P  1.0). However, there was 100% (n = 13) improvement of this copper beaten sign. However, the neurodevelopmental delay showed no improvement which was statistically not significant (P > 1.0).

    CONCLUSION: Surgery in craniosynostosis patient increases the ICV besides it improves the shape of the head. From this study, the syndromic synostosis had better increment of ICV compared to nonsyndromic synostosis.

    Matched MeSH terms: Tomography, X-Ray Computed/methods
  3. Chan AKH, Yusof MI, Abdullah MS
    Asian Spine J, 2021 Feb;15(1):1-8.
    PMID: 32252193 DOI: 10.31616/asj.2019.0242
    STUDY DESIGN: This is an observational study of computed tomography (CT) data.

    PURPOSE: The C1 and C2 laminas in the Malaysian Malay population were analyzed for the feasibility of fitting 3.5-mm laminar screws in a cross configuration.

    OVERVIEW OF LITERATURE: Morphometric analysis of the C1 and C2 laminas has been performed for various populations but not for the Malaysian Malay population.

    METHODS: A total of 330 CT cervical images were measured to establish the bicortical diameter of the C1 and C2 laminas as well as their height and length. The C1 posterior tubercle bicortical diameter and height were also determined from these images. All parameters were measured up to 0.1 mm, and statistical analysis was performed using IBM SPSS Statistics ver. 24.0 (IBM Corp., Armonk, NY, USA). An independent t -test and the Pearson chi-square test were used to determine the mean difference and screw acceptance.

    RESULTS: The means of the C1 lamina measurements were 5.79±1.19 mm in diameter, 9.76±1.51 mm in height, and 20.70±1.86 mm in length. The means of the measurements of the posterior tubercle were 7.20±1.88 mm in diameter and 10.51±1.68 mm in height. The means of the C2 lamina measurements were 5.74±1.31 mm in diameter, 11.76±1.69 mm in height, and 24.96±2.56 mm in length. Overall 65.5% of C1 and 80.3% of C2 laminas are able to accept 3.5-mm screws in a cross configuration. Screw acceptability is similar between the right and left sides (p >0.05). However, males have a higher screw acceptability compared with females (p <0.05), except for the C2 left lamina.

    CONCLUSIONS: It is feasible to insert a 3.5-mm screw in a cross configuration in the C1 and C2 laminas of the Malaysian Malay population, especially in males. However, a CT scan should be performed prior to the operation to determine screw acceptability and to estimate screw sizes.

    Matched MeSH terms: Tomography; Tomography, X-Ray Computed
  4. Ng CC, Lee ZY, Chan WY, Jamaluddin MF, Tan LJ, Sitaram PN, et al.
    JPEN J Parenter Enteral Nutr, 2020 03;44(3):425-433.
    PMID: 31173666 DOI: 10.1002/jpen.1666
    BACKGROUND: Low muscularity (LM) is associated with high mortality in the Caucasian critically ill population. Muscularity can be accurately measured by the skeletal muscle index (SMI; cm2 /m2 ) generated by computed tomography (CT). This study aimed to establish the overall and sex-specific cutoff values that predict hospital mortality in an Asian critically ill population.

    METHODS: This single-center, retrospective, observational study included patients aged ≥18 years with an abdominal CT conducted within 72 hours of admission to the intensive care unit. SMI generated from CT images at the level of the mid-third lumbar vertebra were extracted from the medical records. Area under the receiver operating characteristic curves (AUC) was generated to determine the SMI cutoff values for hospital mortality. Association between LM (defined by SMI cutoff value) and hospital mortality was further evaluated by multivariable logistic regression.

    RESULTS: In a sample of 228 patients, the overall SMI cutoff value (cm2 /m2 ) for hospital mortality was 42.0 (AUC: 0.637; sensitivity: 66.7%, specificity: 56.8%), whereas it was 46.5 in males and 35.3 in females. More males than females had LM (51.4% vs 37.5%), and >40% of overweight/obese patients had LM. Patients with LM were older and had a longer duration of mechanical ventilation and hospitalization. After adjusting for known confounders, LM independently predicted hospital mortality in the overall sample (adjusted odds ratio: 2.42; 95% CI 1.16-5.03; P = 0.003) and in both sexes.

    CONCLUSION: This study established a set of SMI cutoff values that predict hospital mortality. LM is independently associated with hospital mortality.

    Matched MeSH terms: Tomography, X-Ray Computed*
  5. Samson DO, Jafri MZM, Shukri A, Hashim R, Sulaiman O, Aziz MZA, et al.
    Radiat Environ Biophys, 2020 08;59(3):483-501.
    PMID: 32333105 DOI: 10.1007/s00411-020-00844-z
    For the first time, Rhizophora spp. (Rh. spp.) particleboard phantoms were developed using defatted soy flour (DSF) and soy protein isolate (SPI) modified by sodium hydroxide and itaconic acid polyamidoamine-epichlorohydrin (IA-PAE) adhesive. The microstructural characterization and X-ray diffraction patterns of the material revealed that the modified DSF and SPI adhesives became more compact and homogeneous when NaOH/IA-PAE was added, which prevented damage by moisture. It was confirmed that the composite is crystalline with (101), (002), and (004) orientations. Phantoms made of this material were scanned with X-ray computed tomography (CT) typically used for abdominal examinations with varying energies corresponding to 80, 120, and 135 kVp, to determine CT numbers, electron densities, and density distribution profiles. The radiation attenuation parameters were found to be not significantly different from those of water (XCOM) with p values [Formula: see text] 0.05 for DSF and SPI. The DSF- and SPI-based particleboard phantoms showed CT numbers close to those of water at the three X-ray CT energies. In addition, electron density and density distribution profiles of DSF-SPI-Rh. spp. particleboard phantoms with 15 wt% IA-PAE content were even closer to those of water and other commercial phantom materials at the three X-ray CT energies. It is concluded that DSF-SPI with NaOH/IA-PAE added can be used as a potential adhesive in Rh. spp. particleboard phantoms for radiation dosimetry.
    Matched MeSH terms: Tomography, X-Ray Computed*
  6. Liyana Dhamirah Aminuddin, Sabrina Ab Wahab, Suhaili Shariffudin, Tarita Tai
    MyJurnal
    Patients with lung cancer may present with respiratory and systemic symptoms. However,
    cutaneous metastases from primary lung cancer is a rare phenomenon, especially in women,
    that signifies a poor prognosis. This paper reported a case regarding a 71-year-old woman
    who was first presented with a cutaneous nodule over the year. Her condition was further
    progressed to multiple lesions on the back and abdomen, dyspnoea, haemoptysis and weight
    loss. The results of the skin lesion biopsy exhibited metastatic lung adenocarcinoma with
    positive immunohistochemistry for thyroid transcription factor 1 (TTF1) and cytokeratin 7 (CK7). Computed tomography (CT) scan was conducted, and it revealed a left upper lobe lung
    mass. The patient was subsequently scheduled for additional management, but she had
    succumbed to complications of pulmonary embolism before the necessary interventions could
    be provided. In this particular case presentation, the biopsy of cutaneous lesions obtained had
    revealed an undiagnosed primary malignancy.
    Matched MeSH terms: Tomography; Tomography, X-Ray Computed
  7. Khoo ACH, Cheong YT
    World J Nucl Med, 2020 01 14;19(1):89-91.
    PMID: 32190033 DOI: 10.4103/wjnm.WJNM_14_19
    Renal cell carcinomas (RCCs) commonly metastasize to the lungs and bones and rarely to the parathyroid, maxillary sinus, and adrenals. It is indeed very rare to have these all these metastases occurring simultaneously in an individual. We share a case of 67-year-old woman provisionally treated for parathyroid carcinoma but subsequently found to actually have metastatic RCC to the left maxillary sinus, parathyroid, lungs, and adrenals on 18F-fluorodeoxyglucose positron emission tomography-computed tomography.
    Matched MeSH terms: Positron Emission Tomography Computed Tomography
  8. Alenezi SA, Dannoon SF, Alnafisi NS, Asa'ad SM, Osman MM, Elgazzar AH
    World J Nucl Med, 2020 01 14;19(1):41-46.
    PMID: 32190021 DOI: 10.4103/wjnm.WJNM_16_19
    The aim of this study is to investigate the relationship between brown adipose tissue (BAT) activation and myocardial fluorine-18-fluorodeoxyglucose ([18F] FDG) uptake in terms of intensity and patterns. The patients were divided into two groups as follows: BAT and control groups. The BAT group consists of 34 cases that showed BAT uptake. The control group, with no BAT uptake, included 68 patients who were matched for body mass index, gender, and season. The scans were retrospectively reviewed by two nuclear medicine physicians who visually evaluated the intensity of myocardial [18F] FDG uptake. The myocardial [18F] FDG uptake was visually classified into the following three patterns: diffuse, heterogeneous, and focal. The regions of activated BAT distribution were noted. The mean myocardial [18F] FDG uptake was 2.50 ± 0.75 for the BAT group and 2.13 ± 0.88 for the control group with a statistically significant difference (P = 0.031). The myocardial [18F] FDG uptake pattern was similar in the BAT and control groups with the diffuse pattern being the most common, followed by the heterogeneous and less commonly focal. In the BAT group, the anatomical distribution of BAT was mainly in supraclavicular, paravertebral, and axillary and to a lesser extent in cervical regions. BAT group had a significantly higher intensity of [18F] FDG myocardial uptake compared to that of the control group. The presence of activated BAT did not affect the pattern of myocardial uptake. Knowledge of these findings may help in understanding the variability of myocardial [18F] FDG uptake and consequently in avoiding misinterpretation of cardiac findings in positron-emission tomography/computed tomography studies.
    Matched MeSH terms: Positron Emission Tomography Computed Tomography
  9. Ng BH, Nuratiqah NA, Andrea YLB, Faisal AH, Soo CI, Najma K, et al.
    Med J Malaysia, 2020 07;75(4):368-371.
    PMID: 32723996
    BACKGROUND AND OBJECTIVE: Coronavirus Disease 2019 (COVID- 19) was first reported in Malaysia in March 2020. We describe here the clinical characteristics and computed tomography (CT) patterns in asymptomatic young patients who had laboratory-confirmed COVID-19.

    METHODS: This is a retrospective observational study where 25 male in-patients with laboratory-confirmed COVID-19 in Hospital Canselor Tuanku Muhriz. Demographics, clinical data and CT images of these patients were reviewed by 2 senior radiologists.

    RESULTS: In total there were 25 patients (all males; mean age [±SD], 21.64±2.40 years; range, 18-27 years). Patients with abnormal chest CT showed a relatively low normal absolute lymphocytes count (median: 2.2 x 109/L) and absolute monocyte count (median: 0.5 x 109/L). Lactate dehydrogenase was elevated in 5 (20%) of the patients. The procalcitonin level was normal while elevated levels of alanine aminotransferase, total bilirubin, platelet and C-reactive protein were common. Baseline chest CT showed abnormalities in 6 patients. The distribution of the lesions were; upper lobe 3 (12%) lower lobe 3 (12%) with peripheral distribution 4 (16%). Of the 25 patients included, 4 (16%) had ground glass opacification (GGO), 1 (4%) had a small peripheral subpleural nodule, and 1 (4%) had a dense solitary granuloma. Four patients had typical CT features of COVID-19.

    CONCLUSION: We found that the CT imaging showed peripheral GGO in our patients. They remained clinically stable with no deterioration of their respiratory symptoms suggesting stability in lung involvement. We postulate that rapid changes in CT imaging may not be present in young, asymptomatic, non-smoking COVID-19 patients. Thus the use of CT thoraxfor early diagnosis may be reserved for patients in the older agegroups, and not in younger patients.

    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  10. Shahril Shamsul, Akmal Sabarudin, Hamzaini Abdul Hamid, Norzailin Abu Bakar, Oteh Maskon, Muhammad Khalis Abdul Karim
    MyJurnal
    The purpose of this study was to evaluate the image quality and diagnostic accuracy of coronary computed tomography angiography (CCTA) using 640-slice scanner. Advancement of multidetector computed tomography (MDCT) technology with higher spatial, temporal resolution, and increasing detector array have improved the image quality and diagnostic accuracy of CCTA. A total of 25 patients (12 men and 13 women) underwent CCTA examination was chosen and data was acquired by 640-slice scanner. All 16 segments of coronary arteries were evaluated by two reviewers using a 4-likert scale for qualitative assessment. In quantitative assessment, the evaluation of 4 main coronary arteries were analysed in terms of signal intensity (SI), image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). All 25 patients with a mean age of 52.88 ± 14.75 years old and body mass index (BMI) of 24.24 ± 3.28 kg/m2 were analysed. In qualitative assessment, from the total of 400 segments, 379 segments (95%) had diagnostic value while 21 segments did not have diagnostic value, which means 5% artefact was detected. In quantitative assessment, there was no statistical differences in gender, race, and BMI (p>0.05). Overall evaluation showed that higher SI at the left main artery (LM) at 393.7 ± 47.19. Image noise was higher at right coronary artery (RCA) at 39.01 ± 13.97. SNR and CNR showed higher at left anterior descending (LAD) with 12.73 ± 5.17 and LM 9.14 ± 4.2, respectively. In conclusion, this study indicates that 640-slice MDCT has higher diagnostic value in CCTA examination with 95% vessel visibility with 5% artefact detection.
    Matched MeSH terms: Multidetector Computed Tomography; Computed Tomography Angiography
  11. Yusof MYPM, Mah MC, Reduwan NH, Kretapirom K, Affendi NHK
    Saudi Dent J, 2020 Dec;32(8):396-402.
    PMID: 33304083 DOI: 10.1016/j.sdentj.2019.10.010
    Objective: Knowledge and evaluation of the blood supply within the maxillary sinus before sinus augmentation are vital to avoid surgical complications. The lateral maxilla is supplied by branches of the posterior superior alveolar artery and infraorbital artery forming intraosseous anastomoses (IA) within the bony lateral antral wall. This study was undertaken to (i) measure mean diameter of IA and its distance from the alveolar ridge within dentate and posteriorly edentulous subjects and, (ii) qualitatively display the relationship of IA throughout its course within the lateral maxillary sinus in cone beam computed tomography (CBCT).

    Method: Maxillary CBCT images of two-hundred-and-fifty-seven consecutive patients (163 men, 94 women, mean age 42 years) were analyzed. Samples were later divided into dentate (n = 142) and posteriorly edentulous (n = 115) jaws. Using both alveolar ridge and tooth location as reference points, the distance and diameter of IA were assessed.

    Result: The IA was seen in 63.7% of all sinuses with 68.2% in dentate and 62.4% in edentulous. Mean distance and diameter of IA across the posterior tooth locations were 17.9 ± 3.0 mm and 1.4 ± 0.5 mm (dentate) and 15.1 ± 3.0 mm and 1.0 ± 0.5 mm (posteriorly edentulous), respectively. In each sample, there were no significant differences in distance-alveolar ridge and no significant correlations in diameter-tooth location. A statistically significant Pearson coefficient correlation between diameter and distance in dentate state was observed (r = -0.6).

    Conclusion: This study reveals that dentate maxillary jaws present larger diameters as compared to posteriorly edentulous jaws, although the IA course remains the same. As these canal structures contain neurovascular bundles with diameters that may be large enough to cause clinically substantial complications, a thorough pre-surgical planning is therefore highly advisable.

    Matched MeSH terms: Cone-Beam Computed Tomography; Spiral Cone-Beam Computed Tomography
  12. Ismail NA, Abdullah N, Mohamad Noor MH, Lai PS, Shafie MS, Nor FM
    J Forensic Leg Med, 2019 Apr;63:11-17.
    PMID: 30825771 DOI: 10.1016/j.jflm.2019.02.010
    BACKGROUND: In the application of scientific human skeletal variation in medico-legal matters, virtual anthropology is the current technique performed to examine skeleton and its body parts. Hence, this study was conducted to assess the accuracy and reliability of virtual femur measurement through intra and inter-observer error analysis, and comparison was made between the virtual and conventional methods.

    METHODS: A total of 15 femora were examined with four parameters i.e. maximum length of femur (FeMl), diameter of femoral head (FeHd), transverse diameter of midshaft (FeMd) and condylar breadth (FeCb). Osteometric board and vernier calipers were employed for the conventional method, while CT reconstructed images and Osirix MD software was utilised for the virtual method.

    RESULTS: Results exhibited that there were no significant differences in the measurements by conventional and virtual methods. There were also no significant differences in the measurements by the intra or inter-observer error analyses. The intraclass correlation coefficients (ICC) were more than 0.95 by both intra and inter-observer error analyses. Technical error of measurement had displayed values within the acceptable ranges (rTEM <0.08 for intra-observer, <2.25 for inter-observer), and coefficient of reliability (R) indicated small measurement errors (R > 0.95 for intra-observer, R > 0.92 for inter-observer). By parameters, FeMl showed the highest R value (0.99) with the least error in different methods and observers (rTEM = 0.02-0.41%). Bland and Altman plots revealed points scattered close to zero indicating perfect agreement by both virtual and conventional methods. The mean differences for FeMl, FeHd, FeMd and FeCb measurements were 0.01 cm, -0.01 cm, 0.02 cm and 0.01 cm, respectively.

    CONCLUSION: This brought to suggest that bone measurement by virtual method was highly accurate and reliable as in the conventional method. It is recommended for implementation in the future anthropological studies especially in countries with limited skeletal collection.

    Matched MeSH terms: Multidetector Computed Tomography*
  13. Al-Shabi M, Lan BL, Chan WY, Ng KH, Tan M
    Int J Comput Assist Radiol Surg, 2019 Oct;14(10):1815-1819.
    PMID: 31020576 DOI: 10.1007/s11548-019-01981-7
    PURPOSE: Lung nodules have very diverse shapes and sizes, which makes classifying them as benign/malignant a challenging problem. In this paper, we propose a novel method to predict the malignancy of nodules that have the capability to analyze the shape and size of a nodule using a global feature extractor, as well as the density and structure of the nodule using a local feature extractor.

    METHODS: We propose to use Residual Blocks with a 3 × 3 kernel size for local feature extraction and Non-Local Blocks to extract the global features. The Non-Local Block has the ability to extract global features without using a huge number of parameters. The key idea behind the Non-Local Block is to apply matrix multiplications between features on the same feature maps.

    RESULTS: We trained and validated the proposed method on the LIDC-IDRI dataset which contains 1018 computed tomography scans. We followed a rigorous procedure for experimental setup, namely tenfold cross-validation, and ignored the nodules that had been annotated by

    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  14. Sabarudin A, Subramaniam C, Sun Z
    Quant Imaging Med Surg, 2014 Aug;4(4):282-90.
    PMID: 25202664 DOI: 10.3978/j.issn.2223-4292.2014.07.10
    The purpose of this study was to analyse the diagnostic value of cerebral CT angiography (CTA) and CT perfusion (CTP) examinations in the detection of acute stroke based on a systematic review of the current literature. The review was conducted based on searching of seven databases for articles published between 1993 and 2013. Diagnostic value in terms of sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy was analysed from 21 articles which were found to meet selection criteria. The mean sensitivity, specificity, PPV, NPV and accuracy for CTA were significantly higher than those for CTP with 83.2% (95% CI: 57.9-100.0%), 95.0% (95% CI: 74.4-100%), 84.1% (95% CI: 50.0-100%), 97.1 (95% CI: 94.0-100%) and 94.0% (95% CI: 83.0-99.0) versus 69.9% (95% CI: 20.0-97.0%), 87.4 (95% CI: 61.0-100.0%), 76.4% (95% CI: 48.0-95.4%), 78.2% (95% CI: 55.8-93.9%) and 89.8% (95% CI: 75.7-97.1%), respectively. This analysis shows that CTA has high diagnostic value in detecting high degree of cerebral arterial stenosis (>70%) whereas CTP provides high specificity in the detection of ischemia and infarct tissue of brain.
    Matched MeSH terms: Tomography, X-Ray Computed; Computed Tomography Angiography
  15. Chian TC, Nassir NM, Ibrahim MI, Yusof AK, Sabarudin A
    Quant Imaging Med Surg, 2017 Feb;7(1):48-58.
    PMID: 28275559 DOI: 10.21037/qims.2017.02.02
    BACKGROUND: This study was carried out to quantify and compare the quantitative image quality of coronary computed tomography angiography (CCTA) between genders as well as between different tube voltages scan protocols.

    METHODS: Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software.

    RESULTS: Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp.

    CONCLUSIONS: There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.

    Matched MeSH terms: Tomography, X-Ray Computed; Computed Tomography Angiography
  16. Mustapha FA, Bashah FAA, Yassin IM, Fathinul Fikri AS, Nordin AJ, Abdul Razak HR
    Quant Imaging Med Surg, 2017 Jun;7(3):310-317.
    PMID: 28811997 DOI: 10.21037/qims.2017.05.03
    BACKGROUND: Kidneys and urinary bladder are common physiologic uptake sites of 18fluorine-fluorodeoxyglucose ((18)F-FDG) causing increased exposure of low energy ionizing radiation to these organs. Accurate measurement of organ dose is vital as (18)F-FDG is directly exposed to the organs. Organ dose from (18)F-FDG PET is calculated according to the injected (18)F-FDG activity with the application of dose coefficients established by International Commission on Radiological Protection (ICRP). But this dose calculation technique is not directly measured from these organs; rather it is calculated based on total injected activity of radiotracer prior to scanning. This study estimated the (18)F-FDG dose to the kidneys and urinary bladder in whole body positron emission tomography/computed tomography (PET/CT) examination by comparing dose from total injected activity of (18)F-FDG (calculated dose) and dose from organs activity based on the region of interest (ROI) (measured dose).

    METHODS: Nine subjects were injected intravenously with the mean (18)F-FDG dose of 292.42 MBq prior to whole body PET/CT scanning. Kidneys and urinary bladder doses were estimated by using two approaches which are the total injected activity of (18)F-FDG and organs activity concentration of (18)F-FDG based on drawn ROI with the application of recommended dose coefficients for (18)F-FDG described in the ICRP 80 and ICRP 106.

    RESULTS: The mean percentage difference between calculated dose and measured dose ranged from 98.95% to 99.29% for the kidneys based on ICRP 80 and 98.96% to 99.32% based on ICRP 106. Whilst, the mean percentage difference between calculated dose and measured dose was 97.08% and 97.27% for urinary bladder based on ICRP 80 while 96.99% and 97.28% based on ICRP 106. Whereas, the range of mean percentage difference between calculated and measured organ doses derived from ICRP 106 and ICRP 80 for kidney doses were from 17.00% to 40.00% and for urinary bladder dose was 18.46% to 18.75%.

    CONCLUSIONS: There is a significant difference between calculated dose and measured dose. The use of organ activity estimation based on drawn ROI and the latest version of ICRP 106 dose coefficient should be explored deeper to obtain accurate radiation dose to patients.

    Matched MeSH terms: Positron Emission Tomography Computed Tomography
  17. Tan SK, Ng KH, Yeong CH, Raja Aman RRA, Mohamed Sani F, Abdul Aziz YF, et al.
    Quant Imaging Med Surg, 2019 Apr;9(4):552-564.
    PMID: 31143647 DOI: 10.21037/qims.2019.03.13
    Background: High delivery rate is an important factor in optimizing contrast medium administration in coronary computed tomography angiography (CCTA). A personalized contrast volume calculation algorithm incorporating high iodine delivery rate (IDR) can reduce total iodine dose (TID) and produce optimal vessel contrast enhancement (VCE) in low tube voltage CCTA. In this study, we developed and validated an algorithm for calculating the volume of contrast medium delivered at a high rate for patients undergoing retrospectively ECG-gated CCTA with low tube voltage protocol.

    Methods: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols.

    Results: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05).

    Conclusions: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.

    Matched MeSH terms: Tomography, X-Ray Computed; Computed Tomography Angiography
  18. Appalanaido GK, Bahajjaj SIBZ, Shukor SA, Ahmad MZ, Francis HCH
    Oxf Med Case Reports, 2021 Apr;2021(4):omab016.
    PMID: 33948189 DOI: 10.1093/omcr/omab016
    Liver is the most common site for metastasis from colorectal cancer (CRC). Non-surgical treatment options for oligometastatic CRC confined to the liver which represents an intermediate state in the metastatic cascade are fast expanding. Currently, several liver-directed local therapeutic options are available, such as hepatic arterial infusion (HAI) therapy, radio-frequency ablation (RFA), transarterial chemoembolization (TACE), stereotactic body radiotherapy and high dose rate brachytherapy (HDRBT). Many factors such as patient's fitness, liver function (LF), tumour size, location of the tumour in the liver and scheduling of systemic therapy need to be considered when selecting patients for surgery or local liver-directed therapy. This case report illustrates a successful local treatment with staged HDRBT for a large and unresectable, liver only oligometastatic disease from CRC. This patient underwent 4 cycles of chemotherapy (FOLFOX 4) followed by primary tumour resection and first stage of HDRBT to liver for a residual 14 cm tumour after the chemotherapy. After completing a further 4 cycles of chemotherapy with the same regimen, the tumour remained stable at 8 cm. She underwent a second stage of HDRBT to the same lesion and a repeat PET-CT scan done 8 weeks after the second HDRBT showed complete metabolic response. To our knowledge, this is the largest CRC metastatic liver lesion that has been successfully treated with HDRB.
    Matched MeSH terms: Positron Emission Tomography Computed Tomography
  19. Dong X, Xu S, Liu Y, Wang A, Saripan MI, Li L, et al.
    Cancer Imaging, 2020 Aug 01;20(1):53.
    PMID: 32738913 DOI: 10.1186/s40644-020-00331-0
    BACKGROUND: Convolutional neural networks (CNNs) have been extensively applied to two-dimensional (2D) medical image segmentation, yielding excellent performance. However, their application to three-dimensional (3D) nodule segmentation remains a challenge.

    METHODS: In this study, we propose a multi-view secondary input residual (MV-SIR) convolutional neural network model for 3D lung nodule segmentation using the Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset of chest computed tomography (CT) images. Lung nodule cubes are prepared from the sample CT images. Further, from the axial, coronal, and sagittal perspectives, multi-view patches are generated with randomly selected voxels in the lung nodule cubes as centers. Our model consists of six submodels, which enable learning of 3D lung nodules sliced into three views of features; each submodel extracts voxel heterogeneity and shape heterogeneity features. We convert the segmentation of 3D lung nodules into voxel classification by inputting the multi-view patches into the model and determine whether the voxel points belong to the nodule. The structure of the secondary input residual submodel comprises a residual block followed by a secondary input module. We integrate the six submodels to classify whether voxel points belong to nodules, and then reconstruct the segmentation image.

    RESULTS: The results of tests conducted using our model and comparison with other existing CNN models indicate that the MV-SIR model achieves excellent results in the 3D segmentation of pulmonary nodules, with a Dice coefficient of 0.926 and an average surface distance of 0.072.

    CONCLUSION: our MV-SIR model can accurately perform 3D segmentation of lung nodules with the same segmentation accuracy as the U-net model.

    Matched MeSH terms: Tomography, X-Ray Computed/methods*
  20. Sultan T, Cheah CW, Ibrahim NB, Asif MK, Vaithilingam RD
    J Dent, 2020 Oct;101:103455.
    PMID: 32828845 DOI: 10.1016/j.jdent.2020.103455
    OBJECTIVES: This clinical study assessed and compared the linear and volumetric changes of extraction sockets grafted with a combination of Platelet-Rich Fibrin (PRF) and Calcium Sulfate (CS) (PRF-CS), and extraction sockets grafted with a combination of PRF and xenograft (X) (PRF-X).

    METHODS: Five single maxillary premolar extraction sockets received PRF-CS grafts and five single maxillary premolar sockets received PRF-X grafts. Linear (horizontal and vertical) measurements were accomplished using Cone Beam Computed Tomography (CBCT) images and volumetric changes were assessed using MIMICS software. Soft tissue level changes were measured using Stonecast models. All measurements were recorded at baseline (before extraction) and at 5-months post-extraction.

    RESULTS: Significant reduction in vertical and horizontal dimensions were observed in both groups except for distal bone height (DBH = 0.44 ± 0.45 mm, p = 0.09) and palatal bone height (PBH = 0.39 ± 0.34 mm, p = 0.06) in PRF-X group. PRF-CS group demonstrated mean horizontal shrinkage of 1.27 ± 0.82 mm (p = 0.02), when compared with PRF-X group (1.40 ± 0.85 mm, p = 0.02). Vertical resorption for mesial bone height (MBH = 0.56 ± 0.25 mm, p = 0.008), buccal bone height (BBH = 1.62 ± 0.91 mm, p = 0.01) and palatal bone height (PBH = 1.39 ± 0.87 mm, p = 0.02) in PRF-CS group was more than resorption in PRF-X group (MBH = 0.28 ± 0.14 mm, p = 0.01, BBH = 0.63 ± 0.39 mm, p = 0.02 and PBH = 0.39 ± 0.34 mm, p = 0.06). Volumetric bone resorption was significant within both groups (PRF-CS = 168.33 ± 63.68 mm3, p = 0.004; PRF-X = 102.88 ± 32.93 mm3, p = 0.002), though not significant (p = 0.08) when compared between groups. In PRF-X group, the distal soft tissue level (DSH = 1.00 ± 0.50 mm, p = 0.03) demonstrated almost 2 times more reduction when compared with PRF-CS group (DSH = 1.00 ± 1.00 mm, 0.08). The reduction of the buccal soft tissue level was pronounced in PRF-CS group (BSH = 2.00 ± 2.00 mm, p = 0.06) when compared with PRF-X group (BSH = 1.00 ± 1.50 mm, p = 0.05).

    CONCLUSIONS: PRF-CS grafted sites showed no significant difference with PRF-X grafted sites in linear and volumetric dimensional changes and might show clinical benefits for socket augmentation. The study is officially registered with ClinicalTrials.gov Registration (NCT03851289).

    Matched MeSH terms: Cone-Beam Computed Tomography; Spiral Cone-Beam Computed Tomography
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links