OBJECTIVE: The aim of this study is to evaluate the ICV in primary craniosynostosis patients after the cranial vault reshaping with or without FOA and to compare between syndromic and nonsyndromic synostosis group, to determine factors that associated with significant changes in the ICV postoperative, and to evaluate the resolution of copper beaten sign and improvement in neurodevelopmental delay after the surgery.
METHODS: This is a prospective observational study of all primary craniosynostosis patients who underwent operation cranial vault reshaping with or without FOA in Hospital Kuala Lumpur from January 2017 until Jun 2018. The ICV preoperative and postoperative was measured using the 3D computed tomography (CT) imaging and analyzed. The demographic data, clinical and radiological findings were identified and analyzed.
RESULTS: A total of 14 cases (6 males and 8 females) with 28 3D CT scans were identified. The mean age of patients was 23 months. Seven patients were having syndromic synostosis (4 Crouzon syndromes and 3 Apert syndromes) and 7 nonsyndromic synostosis. The mean preoperative ICV was 880 mL (range, 641-1234 mL), whereas the mean postoperative ICV was 1081 mL (range, 811-1385 mL). The difference was 201 mL which was statistically significant (P 1.0). However, there was 100% (n = 13) improvement of this copper beaten sign. However, the neurodevelopmental delay showed no improvement which was statistically not significant (P > 1.0).
CONCLUSION: Surgery in craniosynostosis patient increases the ICV besides it improves the shape of the head. From this study, the syndromic synostosis had better increment of ICV compared to nonsyndromic synostosis.
PURPOSE: The C1 and C2 laminas in the Malaysian Malay population were analyzed for the feasibility of fitting 3.5-mm laminar screws in a cross configuration.
OVERVIEW OF LITERATURE: Morphometric analysis of the C1 and C2 laminas has been performed for various populations but not for the Malaysian Malay population.
METHODS: A total of 330 CT cervical images were measured to establish the bicortical diameter of the C1 and C2 laminas as well as their height and length. The C1 posterior tubercle bicortical diameter and height were also determined from these images. All parameters were measured up to 0.1 mm, and statistical analysis was performed using IBM SPSS Statistics ver. 24.0 (IBM Corp., Armonk, NY, USA). An independent t -test and the Pearson chi-square test were used to determine the mean difference and screw acceptance.
RESULTS: The means of the C1 lamina measurements were 5.79±1.19 mm in diameter, 9.76±1.51 mm in height, and 20.70±1.86 mm in length. The means of the measurements of the posterior tubercle were 7.20±1.88 mm in diameter and 10.51±1.68 mm in height. The means of the C2 lamina measurements were 5.74±1.31 mm in diameter, 11.76±1.69 mm in height, and 24.96±2.56 mm in length. Overall 65.5% of C1 and 80.3% of C2 laminas are able to accept 3.5-mm screws in a cross configuration. Screw acceptability is similar between the right and left sides (p >0.05). However, males have a higher screw acceptability compared with females (p <0.05), except for the C2 left lamina.
CONCLUSIONS: It is feasible to insert a 3.5-mm screw in a cross configuration in the C1 and C2 laminas of the Malaysian Malay population, especially in males. However, a CT scan should be performed prior to the operation to determine screw acceptability and to estimate screw sizes.
METHODS: This single-center, retrospective, observational study included patients aged ≥18 years with an abdominal CT conducted within 72 hours of admission to the intensive care unit. SMI generated from CT images at the level of the mid-third lumbar vertebra were extracted from the medical records. Area under the receiver operating characteristic curves (AUC) was generated to determine the SMI cutoff values for hospital mortality. Association between LM (defined by SMI cutoff value) and hospital mortality was further evaluated by multivariable logistic regression.
RESULTS: In a sample of 228 patients, the overall SMI cutoff value (cm2 /m2 ) for hospital mortality was 42.0 (AUC: 0.637; sensitivity: 66.7%, specificity: 56.8%), whereas it was 46.5 in males and 35.3 in females. More males than females had LM (51.4% vs 37.5%), and >40% of overweight/obese patients had LM. Patients with LM were older and had a longer duration of mechanical ventilation and hospitalization. After adjusting for known confounders, LM independently predicted hospital mortality in the overall sample (adjusted odds ratio: 2.42; 95% CI 1.16-5.03; P = 0.003) and in both sexes.
CONCLUSION: This study established a set of SMI cutoff values that predict hospital mortality. LM is independently associated with hospital mortality.
METHODS: This is a retrospective observational study where 25 male in-patients with laboratory-confirmed COVID-19 in Hospital Canselor Tuanku Muhriz. Demographics, clinical data and CT images of these patients were reviewed by 2 senior radiologists.
RESULTS: In total there were 25 patients (all males; mean age [±SD], 21.64±2.40 years; range, 18-27 years). Patients with abnormal chest CT showed a relatively low normal absolute lymphocytes count (median: 2.2 x 109/L) and absolute monocyte count (median: 0.5 x 109/L). Lactate dehydrogenase was elevated in 5 (20%) of the patients. The procalcitonin level was normal while elevated levels of alanine aminotransferase, total bilirubin, platelet and C-reactive protein were common. Baseline chest CT showed abnormalities in 6 patients. The distribution of the lesions were; upper lobe 3 (12%) lower lobe 3 (12%) with peripheral distribution 4 (16%). Of the 25 patients included, 4 (16%) had ground glass opacification (GGO), 1 (4%) had a small peripheral subpleural nodule, and 1 (4%) had a dense solitary granuloma. Four patients had typical CT features of COVID-19.
CONCLUSION: We found that the CT imaging showed peripheral GGO in our patients. They remained clinically stable with no deterioration of their respiratory symptoms suggesting stability in lung involvement. We postulate that rapid changes in CT imaging may not be present in young, asymptomatic, non-smoking COVID-19 patients. Thus the use of CT thoraxfor early diagnosis may be reserved for patients in the older agegroups, and not in younger patients.
Method: Maxillary CBCT images of two-hundred-and-fifty-seven consecutive patients (163 men, 94 women, mean age 42 years) were analyzed. Samples were later divided into dentate (n = 142) and posteriorly edentulous (n = 115) jaws. Using both alveolar ridge and tooth location as reference points, the distance and diameter of IA were assessed.
Result: The IA was seen in 63.7% of all sinuses with 68.2% in dentate and 62.4% in edentulous. Mean distance and diameter of IA across the posterior tooth locations were 17.9 ± 3.0 mm and 1.4 ± 0.5 mm (dentate) and 15.1 ± 3.0 mm and 1.0 ± 0.5 mm (posteriorly edentulous), respectively. In each sample, there were no significant differences in distance-alveolar ridge and no significant correlations in diameter-tooth location. A statistically significant Pearson coefficient correlation between diameter and distance in dentate state was observed (r = -0.6).
Conclusion: This study reveals that dentate maxillary jaws present larger diameters as compared to posteriorly edentulous jaws, although the IA course remains the same. As these canal structures contain neurovascular bundles with diameters that may be large enough to cause clinically substantial complications, a thorough pre-surgical planning is therefore highly advisable.
METHODS: A total of 15 femora were examined with four parameters i.e. maximum length of femur (FeMl), diameter of femoral head (FeHd), transverse diameter of midshaft (FeMd) and condylar breadth (FeCb). Osteometric board and vernier calipers were employed for the conventional method, while CT reconstructed images and Osirix MD software was utilised for the virtual method.
RESULTS: Results exhibited that there were no significant differences in the measurements by conventional and virtual methods. There were also no significant differences in the measurements by the intra or inter-observer error analyses. The intraclass correlation coefficients (ICC) were more than 0.95 by both intra and inter-observer error analyses. Technical error of measurement had displayed values within the acceptable ranges (rTEM <0.08 for intra-observer, <2.25 for inter-observer), and coefficient of reliability (R) indicated small measurement errors (R > 0.95 for intra-observer, R > 0.92 for inter-observer). By parameters, FeMl showed the highest R value (0.99) with the least error in different methods and observers (rTEM = 0.02-0.41%). Bland and Altman plots revealed points scattered close to zero indicating perfect agreement by both virtual and conventional methods. The mean differences for FeMl, FeHd, FeMd and FeCb measurements were 0.01 cm, -0.01 cm, 0.02 cm and 0.01 cm, respectively.
CONCLUSION: This brought to suggest that bone measurement by virtual method was highly accurate and reliable as in the conventional method. It is recommended for implementation in the future anthropological studies especially in countries with limited skeletal collection.
METHODS: We propose to use Residual Blocks with a 3 × 3 kernel size for local feature extraction and Non-Local Blocks to extract the global features. The Non-Local Block has the ability to extract global features without using a huge number of parameters. The key idea behind the Non-Local Block is to apply matrix multiplications between features on the same feature maps.
RESULTS: We trained and validated the proposed method on the LIDC-IDRI dataset which contains 1018 computed tomography scans. We followed a rigorous procedure for experimental setup, namely tenfold cross-validation, and ignored the nodules that had been annotated by
METHODS: Fifty-five cases of CCTA were collected retrospectively and all images including reformatted axial images at systolic and diastolic phases as well as images with curved multi planar reformation (cMPR) were obtained. Quantitative image quality including signal intensity, image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of right coronary artery (RCA), left anterior descending artery (LAD), left circumflex artery (LCx) and left main artery (LM) were quantified using Analyze 12.0 software.
RESULTS: Six hundred and fifty-seven coronary arteries were evaluated. There were no significant differences in any quantitative image quality parameters between genders. 100 kilovoltage peak (kVp) scanning protocol produced images with significantly higher signal intensity compared to 120 kVp scanning protocol (P<0.001) in all coronary arteries in all types of images. Higher SNR was also observed in 100 kVp scan protocol in all coronary arteries except in LCx where 120 kVp showed better SNR than 100 kVp.
CONCLUSIONS: There were no significant differences in image quality of CCTA between genders and different tube voltages. Lower tube voltage (100 kVp) scanning protocol is recommended in clinical practice to reduce the radiation dose to patient.
METHODS: Nine subjects were injected intravenously with the mean (18)F-FDG dose of 292.42 MBq prior to whole body PET/CT scanning. Kidneys and urinary bladder doses were estimated by using two approaches which are the total injected activity of (18)F-FDG and organs activity concentration of (18)F-FDG based on drawn ROI with the application of recommended dose coefficients for (18)F-FDG described in the ICRP 80 and ICRP 106.
RESULTS: The mean percentage difference between calculated dose and measured dose ranged from 98.95% to 99.29% for the kidneys based on ICRP 80 and 98.96% to 99.32% based on ICRP 106. Whilst, the mean percentage difference between calculated dose and measured dose was 97.08% and 97.27% for urinary bladder based on ICRP 80 while 96.99% and 97.28% based on ICRP 106. Whereas, the range of mean percentage difference between calculated and measured organ doses derived from ICRP 106 and ICRP 80 for kidney doses were from 17.00% to 40.00% and for urinary bladder dose was 18.46% to 18.75%.
CONCLUSIONS: There is a significant difference between calculated dose and measured dose. The use of organ activity estimation based on drawn ROI and the latest version of ICRP 106 dose coefficient should be explored deeper to obtain accurate radiation dose to patients.
Methods: The algorithm for an IDR of 2.22 gI·s-1 was developed based on the relationship between VCE and contrast volume in 141 patients; test bolus parameters and characteristics in 75 patients; and, tube voltage in a phantom study. The algorithm was retrospectively tested in 45 patients who underwent retrospectively ECG-gated CCTA with a 100 kVp protocol. Image quality, TID and radiation dose exposure were compared with those produced using the 120 kVp and routine contrast protocols.
Results: Age, sex, body surface area (BSA) and peak contrast enhancement (PCE) were significant predictors for VCE (P<0.05). A strong linear correlation was observed between VCE and contrast volume (r=0.97, P<0.05). The 100-to-120 kVp contrast enhancement conversion factor (Ec) was calculated at 0.81. Optimal VCE (250 to 450 HU) and diagnostic image quality were obtained with significant reductions in TID (32.1%) and radiation dose (38.5%) when using 100 kVp and personalized contrast volume calculation algorithm compared with 120 kVp and routine contrast protocols (P<0.05).
Conclusions: The proposed algorithm could significantly reduce TID and radiation exposure while maintaining optimal VCE and image quality in CCTA with 100 kVp protocol.
METHODS: In this study, we propose a multi-view secondary input residual (MV-SIR) convolutional neural network model for 3D lung nodule segmentation using the Lung Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI) dataset of chest computed tomography (CT) images. Lung nodule cubes are prepared from the sample CT images. Further, from the axial, coronal, and sagittal perspectives, multi-view patches are generated with randomly selected voxels in the lung nodule cubes as centers. Our model consists of six submodels, which enable learning of 3D lung nodules sliced into three views of features; each submodel extracts voxel heterogeneity and shape heterogeneity features. We convert the segmentation of 3D lung nodules into voxel classification by inputting the multi-view patches into the model and determine whether the voxel points belong to the nodule. The structure of the secondary input residual submodel comprises a residual block followed by a secondary input module. We integrate the six submodels to classify whether voxel points belong to nodules, and then reconstruct the segmentation image.
RESULTS: The results of tests conducted using our model and comparison with other existing CNN models indicate that the MV-SIR model achieves excellent results in the 3D segmentation of pulmonary nodules, with a Dice coefficient of 0.926 and an average surface distance of 0.072.
CONCLUSION: our MV-SIR model can accurately perform 3D segmentation of lung nodules with the same segmentation accuracy as the U-net model.
METHODS: Five single maxillary premolar extraction sockets received PRF-CS grafts and five single maxillary premolar sockets received PRF-X grafts. Linear (horizontal and vertical) measurements were accomplished using Cone Beam Computed Tomography (CBCT) images and volumetric changes were assessed using MIMICS software. Soft tissue level changes were measured using Stonecast models. All measurements were recorded at baseline (before extraction) and at 5-months post-extraction.
RESULTS: Significant reduction in vertical and horizontal dimensions were observed in both groups except for distal bone height (DBH = 0.44 ± 0.45 mm, p = 0.09) and palatal bone height (PBH = 0.39 ± 0.34 mm, p = 0.06) in PRF-X group. PRF-CS group demonstrated mean horizontal shrinkage of 1.27 ± 0.82 mm (p = 0.02), when compared with PRF-X group (1.40 ± 0.85 mm, p = 0.02). Vertical resorption for mesial bone height (MBH = 0.56 ± 0.25 mm, p = 0.008), buccal bone height (BBH = 1.62 ± 0.91 mm, p = 0.01) and palatal bone height (PBH = 1.39 ± 0.87 mm, p = 0.02) in PRF-CS group was more than resorption in PRF-X group (MBH = 0.28 ± 0.14 mm, p = 0.01, BBH = 0.63 ± 0.39 mm, p = 0.02 and PBH = 0.39 ± 0.34 mm, p = 0.06). Volumetric bone resorption was significant within both groups (PRF-CS = 168.33 ± 63.68 mm3, p = 0.004; PRF-X = 102.88 ± 32.93 mm3, p = 0.002), though not significant (p = 0.08) when compared between groups. In PRF-X group, the distal soft tissue level (DSH = 1.00 ± 0.50 mm, p = 0.03) demonstrated almost 2 times more reduction when compared with PRF-CS group (DSH = 1.00 ± 1.00 mm, 0.08). The reduction of the buccal soft tissue level was pronounced in PRF-CS group (BSH = 2.00 ± 2.00 mm, p = 0.06) when compared with PRF-X group (BSH = 1.00 ± 1.50 mm, p = 0.05).
CONCLUSIONS: PRF-CS grafted sites showed no significant difference with PRF-X grafted sites in linear and volumetric dimensional changes and might show clinical benefits for socket augmentation. The study is officially registered with ClinicalTrials.gov Registration (NCT03851289).