Displaying publications 281 - 300 of 561 in total

Abstract:
Sort:
  1. Ong ML, Hatle LK, Lai VM, Bosco J
    Int J Clin Pract, 2002 Jun;56(5):345-8.
    PMID: 12137442
    Iron deposition in the heart occurs in beta-thalassaemia major and contributes to cardiac dysfunction. Eighteen patients with beta-thalassaemia major were assessed clinically and had non-invasive investigations. They were young (15.5 +/- 3.6 years). Two patients had clinical heart failure. Doppler echocardiography demonstrated higher transmitral peak flow velocity in early and late diastole compared with controls (e: p<0.05, a: p<0.01). Transtricuspid peak late diastolic flow velocity was higher in patients (p<0.005). Isovolumic relaxation time was shortened (p<0.001). Pulmonary venous flow velocity was higher in diastole than systole (S: 0.51 +/- 0.11 m/s, D: 0.62 +/- 0.08 m/s). Reversal of pulmonary venous flow during atrial systole was seen in eight patients. These diastolic filling abnormalities did not significantly change with blood transfusion. Left ventricular ejection fraction was normal in patients. Two patients had cardiomegaly on chest X-ray. In beta-thalassaemia with iron overload, there is a restrictive pattern of diastolic dysfunction. This is not altered by recent blood transfusion. Left ventricular function remains relatively intact.
    Matched MeSH terms: Heart Diseases/ultrasonography
  2. Suresh RL, Guinane M, Ainley C
    Med J Malaysia, 2001 Sep;56(3):382-5.
    PMID: 11732088
    Pancreatic sphincter hypertension (PSH) is one of the causes of recurrent pancreatitis. The diagnosis can be established by direct measurement of pancreatic sphincter pressures at pancreatic sphincter manometry. This procedure is not without risks, and in cases with PSH, it certainly carries a higher risk of post procedure pancreatitis. The treatment of this disorder is pancreatic sphincterotomy, which on its own carries risk of acute pancreatitis. Therefore it is important to establish the diagnosis reliably before undertaking this procedure. In order to overcome the false positive readings that are possible in sphincter manometry, we proposed to use secretin stimulated endoscopic ultrasound (SSEUS) to measure pancreatic ductal response as an adjunctive method to aid and supplement the diagnosis. Here we describe 3 cases in which this was carried out to optimal effect.
    Matched MeSH terms: Ultrasonography*
  3. Rossi A, Tomimori E, Camargo R, Medeiros-Neto G
    J Clin Ultrasound, 2002 May;30(4):226-31.
    PMID: 11981932
    Our objective was to establish thyroid volume by sonography in Brazilian schoolchildren and to correlate thyroid volume with anthropometric characteristics.
    Matched MeSH terms: Thyroid Gland/ultrasonography*
  4. Indudharan R, Quah BS, Shuaib IL
    Ann Trop Paediatr, 1999 Mar;19(1):105-8.
    PMID: 10605529
    We describe a 7-year-old child who presented with a soft fluctuant swelling on the neck which became more prominent during the Valsalva manoeuvre. He underwent adeno-tonsillectomy based on a mistaken diagnosis of ballooning of the pharynx secondary to enlarged adenoids and tonsils obstructing the nasopharyngeal and oropharyngeal airways. Investigations revealed the swelling to be a markedly dilated internal jugular vein. We discuss the diagnostic features and mode of treatment of this condition so as to avoid unnecessary and dangerous surgical intervention.
    Matched MeSH terms: Jugular Veins/ultrasonography
  5. Raman S, Urquhart R, Yusof M
    Aust N Z J Obstet Gynaecol, 1992 Aug;32(3):196-9.
    PMID: 1445124
    A prospective study was carried out on 50 patients who had their fetal weight estimated by 3 clinicians of different seniority and compared to the ultrasound estimated fetal weights using 3 different formulas. All the patients delivered within 24 hours of their clinical and ultrasound estimates. A wide range of birth-weights (1,800-4,500 g) was estimated among the 3 different races (Malay, Chinese and Indians). The results showed that there was no significant difference in birth-weight estimation amongst the 3 clinicians as well as between the 3 ultrasound formulas used. There was however significant difference between these 2 groups when compared with the actual birthweight with clinical estimation being superior to ultrasound estimation in our population. This level of significance did not extend beyond 4,000 g fetal weight (actual) thus making both clinical and ultrasound estimation of fetal weight equally accurate after 4,000 g. This has important implications for developing countries where there is a lack of technologically advanced ultrasound machines capable of doing sophisticated functions like fetal weight estimations but has experienced clinicians who could perform this function equally well if not better.
    Matched MeSH terms: Ultrasonography, Prenatal*
  6. Puvaneswary M, Beckhouse M
    Med J Malaysia, 1992 Mar;47(1):81-5.
    PMID: 1387457
    Matched MeSH terms: Pregnancy Complications, Neoplastic/ultrasonography
  7. Alif AK, Meah F
    Med J Malaysia, 1984 Jun;39(2):123-6.
    PMID: 6392839
    Matched MeSH terms: Ultrasonography/methods*
  8. Tawfik EA, Cartwright MS, Grimm A, Boon AJ, Kerasnoudis A, Preston DC, et al.
    Muscle Nerve, 2019 10;60(4):361-366.
    PMID: 31335971 DOI: 10.1002/mus.26642
    Neuromuscular ultrasound has become an essential tool in the diagnostic evaluation of various neuromuscular disorders, and, as such, there is growing interest in neuromuscular ultrasound training. Effective training is critical in mastering this modality. Our aim was to develop consensus-based guidelines for neuromuscular ultrasound training courses. A total of 18 experts participated. Expert opinion was sought through the Delphi method using 4 consecutive electronic surveys. A high degree of consensus was achieved with regard to the general structure of neuromuscular ultrasound training; the categorization of training into basic, intermediate, and advanced levels; the learning objectives; and the curriculum for each level. In this study, a group of neuromuscular ultrasound experts established consensus-based guidelines for neuromuscular ultrasound training. These guidelines can be used in the development of the specialty and the standardization of neuromuscular ultrasound training courses and workshops.
    Matched MeSH terms: Ultrasonography/standards*
  9. Kho SS, Tie ST
    Med J Malaysia, 2019 08;74(4):349-351.
    PMID: 31424050
    Solitary pulmonary nodule (SPN) always raises suspicion for early lung cancer, in which accurate and less invasive biopsy is needed. We report a case of transbronchial cryobiopsy of right upper lobe SPN under radial endobronchial ultrasound (R-EBUS) guidance after an inconclusive computed tomography guided transthoracic needle aspiration. A diagnosis of Stage 1B adenocarcinoma of the lung was made. Patient subsequently underwent curative right upper lobectomy after ruling out mediastinal lymph node involvement. To the best of our knowledge, this is the first report of R-EBUS guided transbronchial cryobiopsy case reported from Malaysia.
    Matched MeSH terms: Ultrasonography, Interventional/methods*
  10. Soo KC, Lee KS, Ooi SY, Darwina A, Sannasey S, Lee HG
    Med J Malaysia, 2021 03;76(2):251-253.
    PMID: 33742639
    Melioidosis is endemic in the State of Sabah, Malaysia. We report a case of a 34-year-old man with one-week history of fever and cough, three days history of diarrhoea and vomiting, which was associated with a loss of appetite and loss of weight for one-month. Clinically, he had hepatosplenomegaly and crepitation over his right lower zone of lung. Chest radiograph showed right lower lobe consolidation. Ultrasound abdomen showed liver and splenic abscesses. Ultrasound guided drainage of splenic abscess yielded Burkholderia pseudomallei. Magnetic resonance imaging (MRI) lumbosacral confirmed right sacral intraosseous abscess after he developed back pain a week later. He received 6 weeks of intravenous antibiotics and oral co-trimoxazole, followed by 6 months oral co-trimoxazole and had full recovery.
    Matched MeSH terms: Ultrasonography; Ultrasonography, Interventional
  11. Adi O, Fong CP, Sum KM, Ahmad AH
    Am J Emerg Med, 2021 04;42:263.e1-263.e4.
    PMID: 32994082 DOI: 10.1016/j.ajem.2020.09.011
    Airway assessment is important in emergency airway management. A difficult airway can lead to life-threatening complications. A perfect airway assessment tool does not exist and unanticipated difficulty will remain unforeseen. Current bedside clinical predictors of the difficult airway are unreliable but airway ultrasound can be used as an adjunct to predict difficult laryngoscopy. We report a case of a 60-year-old man presenting to the emergency department with shortness of breath, hoarseness of voice and stridor. Airway ultrasound revealed a large laryngeal mass narrowing the upper airway, extending to bilateral vocal cords with heterogenous echogenicity. In view of impending complete upper airway obstruction, acute respiratory distress and airway ultrasound findings, urgent emergency tracheostomy was chosen as definitive airway over endotracheal intubation or surgical cricothyroidotomy. Point of care ultrasound (POCUS) was used to evaluate this patient with severe upper airway obstruction. A laryngeal mass was detected by ultrasound and this pointed towards the presence of a difficult airway. POCUS was a good non-invasive tool used for airway assessment in this uncooperative and unstable patient. Ultrasound predictors of the difficult airway include the inability to visualize the hyoid bone, short hyomental distance ratio, high pretracheal anterior neck thickness and large tongue size. Besides airway assessment, ultrasound can also help to predict endotracheal tube size, confirm intubation and guide emergency airway procedures such as cricothyroidotomy and tracheostomy. Point of care ultrasound of the upper airway can be used in airway assessment to identify distorted airway anatomy, pathological lesions and guide treatment decisions.
    Matched MeSH terms: Ultrasonography*
  12. Nicqeshen N, Dilashini S, Kirthana S
    Med J Malaysia, 2020 05;75(3):316-321.
    PMID: 32467556
    INTRODUCTION: Ultrasound is widely available, easy-to-use and less expensive than most other imaging methods. It is widely used as a non-invasive method to diagnose acute appendicitis; however, its efficiency still remains questionable, especially when compared to costlier and invasive methods such as computed tomography.

    METHODS: An exploratory review of past literatures on the usage of ultrasound technique in the diagnosis of acute appendicitis in adult patients, and the role of other imaging techniques were undertaken for the study.

    RESULTS: The gold standard for the diagnosis of acute appendicitis still remains a histopathological confirmation after appendectomy. The study further shows imaging has high diagnostic accuracy in the diagnosis of acute appendicitis with low rate of negative appendectomy (<10%). Multiple reasons are identified, including the introduction of computed tomography imaging especially in those patients where ultrasound was unequivocal, more education on imaging which leads to better operator skill or improved performances of machines.

    CONCLUSION: Imaging undoubtedly plays an important role in the diagnosis of acute appendicitis with ultrasound remaining the first-line method in patients referred with clinically suspected acute appendicitis. Nevertheless, those with borderline ultrasound findings or unable to visualize appendix on ultrasound with highly suspicious sign and symptoms were offered other imaging modalities such as CT scan.

    RECOMMENDATION: It is recommended that the managing team balance the risk of radiation exposure, risk of delay in urgent operation and risk of perforation prior to a decision.

    Matched MeSH terms: Ultrasonography*
  13. Lee ZY, Ong SP, Ng CC, Yap CSL, Engkasan JP, Barakatun-Nisak MY, et al.
    Clin Nutr, 2021 03;40(3):1338-1347.
    PMID: 32919818 DOI: 10.1016/j.clnu.2020.08.022
    BACKGROUND & AIMS: In critically ill patients, direct measurement of skeletal muscle using bedside ultrasound (US) may identify a patient population that might benefit more from optimal nutrition practices. When US is not available, survey measures of nutrition risk and functional status that are associated with muscle status may be used to identify patients with low muscularity. This study aims to determine the association between baseline and changing ultrasound quadriceps muscle status with premorbid functional status and 60-day mortality.

    METHODS: This single-center prospective observational study was conducted in a general ICU. Mechanically ventilated critically ill adult patients (age ≥18 years) without pre-existing systemic neuromuscular diseases and expected to stay for ≥96 h in the ICU were included. US measurements were performed within 48 h of ICU admission (baseline), at day 7, day 14 of ICU stay and at ICU discharge (if stay >14 days). Quadriceps muscle layer thickness (QMLT), rectus femoris cross sectional area (RFCSA), vastus intermedius pennation angle (PA) and fascicle length (FL), and rectus femoris echogenicity (mean and standard deviation [SD]) were measured. Patients' next-of-kin were interviewed by using established questionnaires for their pre-hospitalization nutritional risk (nutrition risk screening-2002) and functional status (SARC-F, clinical frailty scale [CFS], Katz activities of daily living [ADL] and Lawton Instrumental ADL).

    RESULTS: Ninety patients were recruited. A total of 86, 53, 24 and 10 US measures were analyzed, which were performed at a median of 1, 7, 14 and 22 days from ICU admission, respectively. QMLT, RFCSA and PA reduced significantly over time. The overall trend of change of FL was not significant. The only independent predictor of 60-day mortality was the change of QMLT from baseline to day 7 (adjusted odds ratio 0.95 for every 1% less QMLT loss, 95% confidence interval 0.91-0.99; p = 0.02). Baseline measures of high nutrition risk (modified nutrition risk in critically ill ≥5), sarcopenia (SARC-F ≥4) and frailty (CFS ≥5) were associated with lower baseline QMLT, RFCSA and PA and higher 60-day mortality.

    CONCLUSIONS: Every 1% loss of QMLT over the first week of critical illness was associated with 5% higher odds of 60-day mortality. SARC-F, CFS and mNUTRIC are associated with quadriceps muscle status and 60-day mortality and may serve as a potential simple and indirect measures of premorbid muscle status at ICU admission.

    Matched MeSH terms: Ultrasonography*
  14. Omar PM, Lim WT, Ting YH, Lao TT, Law KM, Cheung AHK, et al.
    J Matern Fetal Neonatal Med, 2019 Oct;32(19):3315-3317.
    PMID: 29631451 DOI: 10.1080/14767058.2018.1459556
    The association between hypoechoic hepatomegaly in the third trimester and transient abnormal myelopoiesis (TAM) was reported previously in six fetuses with trisomy 21 (T21). We report a series of three cases of T21 in which hypoechoic liver (HL) was found in the second trimester but without evidence of TAM on both hematological and histological examination. We postulate that the hypo-echogenicity may be due to liver congestion secondary to hemodynamic disturbances seen in T21 fetuses. All three cases had negative first trimester Down syndrome screening and one case was detected solely because of the isolated finding of HL. HL per se may be associated with T21 and more positive cases are required to support this association.
    Matched MeSH terms: Ultrasonography, Prenatal*
  15. Kurien M, Teo R, Zainuddin K, Azidin AM, Izaham A, Budiman M, et al.
    Clin Ter, 2021 Jul 05;172(4):278-283.
    PMID: 34247211 DOI: 10.7417/CT.2021.2332
    Objective: We compared sonoanatomy of the internal jugular vein (IJV) the high (HA), conventional (CA) and the medial oblique approach (MA) to identify the best approach and head position for IJV cannulation.

    Materials & Methods: Total of 45 volunteers aged 18-65 years were included in this study. The degree of overlap in percentage, depth of IJV from skin, antero-posterior (AP) and transverse diameters (TD) of IJV were measured in real time with ultrasound (US). Measurements were taken in the HA, CA and MA in neutral and 30° head rotation on both the right and left side of the neck.

    Results: The HA had lower percentage of overlap when compared to CA and MA in neutral and 30° head rotation (p= 0.002 to ≤0.001). The IJV was more shallow in the CA and MA. The AP and TD of the IJV were larger in the MA when compared to HA (p=<0.001) and CA (p =0.026 to < 0.001) and the right IJV has a larger AP and TD in all approaches.

    Discussion: The HA had the least percentage of overlap compared to CA and MA, therefore the risk of accidental ICA puncture can be reduced. The apparent overlap seen in MA may not reflect the actual scenario because of the way the US beam cuts the vessel. The AP and TD of IJV were significantly increased in the MA, which would ease CVC.

    Conclusion: We conclude and recommend the medial oblique probe position with 30° head rotation provides optimal real time sonographic parameters for US guided IJV cannulation.

    Matched MeSH terms: Ultrasonography/methods*
  16. Jahanfar S, Ho JJ, Jaafar SH, Abraha I, Noura M, Ross CR, et al.
    Cochrane Database Syst Rev, 2021 03 09;3:CD012553.
    PMID: 33686672 DOI: 10.1002/14651858.CD012553.pub2
    BACKGROUND: There is a need to standardize monitoring in obstetric research of twin pregnancies. Identification of birth weight discordance (BWD), defined as a difference in the birth weights of twins, is a well-documented phenomenon in twin pregnancies. Ultrasound for the diagnosis of BWD informs complex decision making including whether to intervene medically (via laser photo coagulation) or deliver the twins to avoid fetal morbidities or even death. The question is, how accurate is this measurement?

    OBJECTIVES: To determine the diagnostic accuracy (sensitivity and specificity) of ultrasound estimated fetal weight discordance (EFWD) of 20% and 25% using different estimated biometric ultrasound measurements compared with the actual BWD as the reference standard in twin pregnancies.

    SEARCH METHODS: The search for this review was performed on 15 March 2019. We searched CENTRAL, MEDLINE (Ovid), Embase (Ovid), seven other databases, conference proceedings, reference lists and contacted experts. There were no language or date restrictions applied to the electronic searches, and no methodological filters to maximize sensitivity.

    SELECTION CRITERIA: We selected cohort-type studies with delayed verification that evaluated the accuracy of biometric measurements at ultrasound scanning of twin pregnancies that had been proposed for the diagnosis of estimated BWD, compared to BWD measurements after birth as a reference standard. In addition, we only selected studies that considered twin pregnancies and applied a reference standard for EFWD for the target condition of BWD.

    DATA COLLECTION AND ANALYSIS: We screened all titles generated by electronic database searches. Two review authors independently assessed the abstracts of all potentially relevant studies. We assessed the identified full papers for eligibility, and extracted data to create 2 × 2 tables. Two review authors independently performed quality assessment using the QUADAS-2 tool. We excluded studies that did not report data in sufficient detail to construct 2 × 2 tables, and where this information was not available from the primary investigators. We assessed the certainty of the evidence using the GRADE approach.

    MAIN RESULTS: We included 39 eligible studies with a median study sample size of 140. In terms of risk of bias, there were many unclear statements regarding patient selection, index test and use of proper reference standard. Twenty-one studies (53%) were of methodological concern due to flow and timing. In terms of applicability, most studies were of low concern. Ultrasound for diagnosis of BWD in twin pregnancies at 20% cut-off Twenty-two studies provided data for a BWD of 20% and the summary estimate of sensitivity was 0.51 (95% CI 0.42 to 0.60), and the summary estimate of specificity was 0.91 (95% CI 0.89 to 0.93) (8005 twin pregnancies; very low-certainty evidence). Ultrasound for diagnosis of BWD in twin pregnancies at 25% cut-off Eighteen studies provided data using a BWD discordance of 25%. The summary estimate of sensitivity was 0.46 (95% CI 0.26 to 0.66), and the summary estimate of specificity was 0.93 (95% CI 0.89 to 0.96) (6471 twin pregnancies; very low-certainty evidence). Subgroup analyses were possible for both BWD of 20% and 25%. The diagnostic accuracy did not differ substantially between estimation by abdominal circumference and femur length but femur length had a trend towards higher sensitivity and specificity. Subgroup analyses were not possible by sex of twins, chorionicity or gestational age due to insufficient data.

    AUTHORS' CONCLUSIONS: Very low-certainty evidence suggests that EFWD identified by ultrasound has low sensitivity but good specificity in detecting BWD in twin pregnancies. There is uncertain diagnostic value of EFWD; this review suggests there is insufficient evidence to support this index as the sole measure for clinical decision making to evaluate the prognosis of twins with growth discordance. The diagnostic accuracy of other measures including amniotic fluid index and umbilical artery Doppler resistive indices in combination with ultrasound for clinical intervention requires evaluation. Future well-designed studies could also evaluate the impact of chorionicity, sex and gestational age in the diagnostic accuracy of ultrasound for EFWD.

    Matched MeSH terms: Ultrasonography, Prenatal/methods*
  17. Leong SS, Wong JHD, Md Shah MN, Vijayananthan A, Jalalonmuhali M, Chow TK, et al.
    Nephrology (Carlton), 2021 Jan;26(1):38-45.
    PMID: 33058334 DOI: 10.1111/nep.13805
    AIM: Renal biopsy is the gold standard for the histological characterization of chronic kidney disease (CKD), of which renal fibrosis is a dominant component, affecting its stiffness. The aim of this study was to investigate the correlation between kidney stiffness obtained by shear wave elastography (SWE) and renal histological fibrosis.

    METHODS: Shear wave elastography assessments were performed in 75 CKD patients who underwent renal biopsy. The SWE-derived estimates of the tissue Young's modulus (YM), given as kilopascals (kPa), were measured. YM was correlated to patients' renal histological scores, broadly categorized into glomerular, tubulointerstitial and vascular scores.

    RESULTS: Young's modulus correlates significantly with tubulointerstitial score (ρ = 0.442, P 

    Matched MeSH terms: Ultrasonography, Interventional/methods
  18. Morishita K, Hiramoto A, Michishita A, Takagi S, Osuga T, Lim SY, et al.
    J. Vet. Intern. Med., 2017 May;31(3):770-777.
    PMID: 28382699 DOI: 10.1111/jvim.14685
    BACKGROUND: Perflubutane microbubbles, a second-generation ultrasound contrast agent, are phagocytized by Kupffer cells. This characteristic may be useful to differentiate diffuse hepatic diseases in dogs.

    HYPOTHESIS/OBJECTIVES: To determine whether the washout ratio in the hepatic vein (HV) measured by contrast-enhanced ultrasonography (CEUS) can distinguish between inflammatory and noninflammatory hepatic disorders in dogs.

    ANIMALS: Forty-one client-owned dogs with hepatic disorders including 14 with hepatitis, 7 with primary hypoplasia of the portal vein (PHPV), 9 with congenital portosystemic shunt (cPSS), and 11 with other hepatopathy were enrolled. Six dogs without hepatic disease also were evaluated as healthy controls.

    METHODS: Dogs with hepatic disorders were prospectively included. Contrast-enhanced ultrasonography of the HV was performed for 2 minutes. Washout ratio was defined as the attenuation rate from peak intensity to the intensity at the end of the CEUS study.

    RESULTS: Washout ratio in the hepatitis group (median, 18.0%; range, 2.0-37.0%) was significantly lower than that of the PHPV (median, 52.2%; range, 11.5-86.3%), cPSS (median, 60.0%; range, 28.6-77.4%), other hepatopathy (median, 70.5%; range, 26.6-88.4%), and normal (median, 78.0%; range, 60.7-91.7%) groups. The area under the receiver operating characteristic curve for hepatitis was 0.960, with a 95% confidence interval (CI) of 0.853-0.990. Washout ratio ≤37.1% resulted in a sensitivity of 100% (95% CI, 78.5-100%) and specificity of 85.2% (95% CI, 67.5-94.1%) for the prediction of hepatitis.

    CONCLUSIONS AND CLINICAL IMPORTANCE: Washout ratio can distinguish hepatitis from the other noninflammatory disorders with high accuracy. This result might reflect impaired Kupffer cell phagocytosis in dogs with hepatitis.

    Matched MeSH terms: Ultrasonography/veterinary
  19. Sivanathan J, Thilaganathan B
    PMID: 28456373 DOI: 10.1016/j.bpobgyn.2017.03.005
    Prenatal diagnosis is a rapidly evolving speciality. Screening for aneuploidy begins with non-sonographic features of background risk of maternal age and past and family history. It is possible to diagnose major structural defects in the foetus using second trimester scans. Serum biochemistry markers in the early second trimester were added to increase the detection rate of aneuploidy. However, as some of these abnormalities were amenable to detection earlier in the first trimester, newer modalities were introduced. Nuchal translucency (NT) measurement was one of the main advances with regard to first trimester screening. Additional markers such as the presence of nasal bone, tricuspid regurgitation, ductus venosus and megacystis; together with first trimester serum biochemistry, further enhanced the detection rate of chromosomal abnormalities. Advances in research and technology have resulted in the availability of non-invasive prenatal testing from 10 weeks of gestation. This has facilitated the detection of the three major chromosomal aneuploidies at very early gestation. However, there are a wide range of genetic syndromes that are not confined to the main trisomies. There are specific markers on ultrasound that can be linked to specific syndromes. Hence, a structured and stepwise approach is needed to identify and reach a possible diagnosis. As anomalies are classified into malformations, deformations and disruptions, it is important to note that not all markers detected are due to genetic syndromes and not all genetic syndromes can be detected on ultrasound scan. In this chapter, we outline common structural markers and their association with main genetic syndromes.
    Matched MeSH terms: Ultrasonography, Prenatal*
  20. Mohd Asihin MA, Bajuri MY, Ahmad J, Syed Kamaruddin SF
    Ceylon Med J, 2018 03 31;63(1):11-16.
    PMID: 29754479
    Objectives: To evaluate the feasibility of ultrasonographic examination in predicting 4-strand semitendinosus and gracilis tendon (4S-STG) autograft size preoperatively in anterior cruciate ligament reconstruction and to evaluate the use of anthropometric measurement to predict the 4-strand semitendinosus and gracilis tendons (4S-STG) autograft size pre-operatively in anterior cruciate ligament reconstruction.

    Method: Twenty-seven patients were included in this study conducted from 1st January to 31st December 2013. All patients were skeletally mature and scheduled to undergo primary anterior cruciate ligament reconstruction using 4S-STG autograft. Ultrasonographic examination of semitendinosus and gracilis tendons to measure the cross sectional area was conducted and anthropometric data (weight, height, leg length and thigh circumference) was measured one day prior to surgery. True autograft diameters were measured intraoperatively using closed-hole sizing block in 0.5 mm incremental size.

    Results: There is a statistically significant correlation between the measured combined cross sectional area (semitendinosus and gracilis tendons) and 4S-STG autograft diameter (p = 0.023). An adequate autograft size (at least 7 mm) can be obtained when the combined cross sectional area is at least 15 mm2. There was no correlation with the anthropometric data except for thigh circumference (p = 0.037). Autograft size of at least 7 mm can be obtained when the thigh circumference is at least 41 mm.

    Conclusions: Both combined cross sectional area (semitendinosus and gracilis tendons) and thigh circumference can be used to predict an adequate 4S-STG autograft size.

    Matched MeSH terms: Ultrasonography/methods*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links