  1. Siti Suhaila MY, Juwita S, Harmy MY, Tengku Alina TI
    MyJurnal
    Introduction: Ambulatory blood pressure accurately reflects a patient's actual blood pressure than casual or office blood pressure. This study aims to describe the circadian blood pressure profile of hypertensive patients and to identify the associated cardiovascular risk factors in non-dippers.
    Methods: A cross-sectional study was conducted from 1st January 2008 to 30th June 2008 among hypertensive patients attending Family Medicine Clinic HUSM. Schiller BR-102 plus was used to get 24 hours blood pressure (BP) reading. Mean of two offices BP were also taken. Non-dippers are defined as a systolic or diastolic nocturnal drop of less than 10%. Analysis was done using SPSS Version 12.
    Results: 105 patients were recruited with mean (SD) age of 51.8 (9.34) year old. The mean (SD) 24-hour systolic and diastolic BP was 128.4 (12.7) mmHg and 79.7 (8.74) mmHg respectively. Mean (SD) daytime systolic and diastolic BP was 132.1 (11.72) mmHg and 82.4 (9.41) mmHg while for the night time were 123.3 (12.78) mmHg and 76.2 (9.01) mmHg. Mean (SD) systolic and diastolic office BP was 144.2(15.16) mmHg and 90.2(9.71) mmHg. Percentage of non dippers were 68.6% for systolic and 61.9% for diastolic.
    Conclusion: Mean 24 hours and daytime ambulatory BP was normal but the mean night time diastolic and office BP was above-normal value. Majority of the patients were categorized as non dippers. Therefore, using ambulatory BP is clinically important to get a better understanding of blood pressure fluctuations over 24-hour periods compared to simple clinical measurements.
    Study site: Family Medicine Clinic, Hospital Universiti Sains Malysia (HUSM), Kelantan, Malaysia
    Matched MeSH terms: Blood Pressure; Blood Pressure Determination; Blood Pressure Monitoring, Ambulatory
  2. Razman, M.R., Jamaluddin, A.R., Ellyda, M.N., Seikh, F.A.
    MyJurnal
    Cardiovascular diseases (CVD) are the leading cause of mortality in Malaysia as well as in other countries. It is associated with many risk factors, such as increasing age, hypertension, diabetes, dyslipidemia, oxidative stress and autonomic dysfunction and arterial stiffness. The objectives of this study were to measure the prevalence of arterial stiffness and to assess its association with dyslipidemia. Methods: A cross sectional study was conducted in a rural community in Malaysia involving 146 subjects. Data were collected using an interviewer administered questionnaire which included three sections – sociodemographic characteristics, personal profile, and past medical history. In addition, Seca Body Meter (Seca 220) was used to measure height and weight. Sphygmomanometer (OMRON Automatic Blood Pressure Monitor HEM 907) and SphygmoCor-AtCor MM3 SERIAL/RS-232 were used for blood pressure and augmentation index (AIx) measurement. Data were analysed using the SPSS for Windows, Version 18.0. Results: The mean age of respondents was 49.5 years, SD±15.6. The prevalence of arterial stiffness was 23.3% (95% Confidence Interval (CI): 16.44 – 30.16). The prevalence of dyslipidemia was 82.9% (95% CI: 76.79 – 89.01). Multivariate logistic regression revealed that total cholesterol was significantly associated with arterial stiffness (OR=4.56, CI 1.10-18.90). Conclusion: The prevalence of dyslipidemia was high. Despite an insignificant association between dyslipidemia and AIx, there is a significant association between TC level and AIx.
    Matched MeSH terms: Blood Pressure; Blood Pressure Determination; Blood Pressure Monitors
  3. Sundram K, Nor RM
    Methods Mol Biol, 2002;186:221-32.
    PMID: 12013770
    Matched MeSH terms: Chromatography, High Pressure Liquid/instrumentation; Chromatography, High Pressure Liquid/methods*
  4. Nakai M, Ribeiro RV, Stevens BR, Gill P, Muralitharan RR, Yiallourou S, et al.
    Hypertension, 2021 09;78(3):804-815.
    PMID: 34333988 DOI: 10.1161/HYPERTENSIONAHA.121.17288
    [Figure: see text].
    Matched MeSH terms: Blood Pressure/physiology; Blood Pressure Monitoring, Ambulatory
  5. Reidpath DD, Ling ML, Yasin S, Rajagobal K, Allotey P
    Glob Health Action, 2012;5:14876.
    PMID: 22761601 DOI: 10.3402/gha.v5i0.14876
    INTRODUCTION: Population monitoring and screening of blood pressure is an important part of any population health strategy. Qualified health workers are expensive and often unavailable for screening. Non-health workers with electronic blood pressure monitors are increasingly used in community-based research. This approach is unvalidated. In a poor, urban community we compared blood pressure measurements taken by non-health workers using electronic devices against qualified health workers using mercury sphygmomanometers.
    METHOD: Fifty-six adult volunteers participated in the research. Data were collected by five qualified health workers, and six non-health workers. Participants were randomly allocated to have their blood pressure measured on four consecutive occasions by alternating a qualified health worker with a non-health worker. Descriptive statistics and graphs, and mixed effects linear models to account for the repeated measurement were used in the analysis.
    RESULTS: Blood pressure readings by non-health workers were more reliable than those taken by qualified health workers. There was no significant difference between the readings taken by qualified health workers and those taken by non-health workers for systolic blood pressure. Non-health workers were, on average, 5-7 mmHg lower in their measures of blood pressure than the qualified health workers (95%HPD: -2.9 to -10.0) for diastolic blood pressure.
    CONCLUSION: The results provide empirical evidence that supports the practice of non-health workers using electronic devices for BP measurement in community-based research and screening. Non-health workers recorded blood pressures that differed from qualified health workers by no more than 10 mmHg. The approach is promising, but more research is needed to establish the generalisability of the results.
    KEYWORDS: Malaysia; blood pressure; community workers; hypertension; measurement; screening
    Study site: urban, low-income community, of the Klang Valley near Kuala Lumpur, Malaysia
    Device: Mercury sphygmomanometers (Spirit brand, model number CK-101C), electronic, automatic blood pressure monitors (Omron brand model HEM-7203)
    Matched MeSH terms: Blood Pressure Determination/instrumentation*; Blood Pressure Determination/statistics & numerical data
  6. Zaki R, Bulgiba A, Ismail NA
    Prev Med, 2013;57 Suppl:S80-2.
    PMID: 23313586 DOI: 10.1016/j.ypmed.2013.01.003
    The Bland-Altman method is the most popular method used to assess the agreement of medical instruments. The main concern about this method is the presence of proportional bias. The slope of the regression line fitted to the Bland-Altman plot should be tested to exclude proportional bias. The aim of this study was to determine whether the overestimation of bias in the Bland-Altman analysis is still present even when the proportional bias has been excluded.
    Matched MeSH terms: Blood Pressure Determination/instrumentation; Blood Pressure Determination/standards
  7. Raharjo Y, Sanagi MM, Ibrahim WA, Naim AA, Aboul-Enein HY
    J Sep Sci, 2009 Feb;32(4):623-9.
    PMID: 19165835 DOI: 10.1002/jssc.200800566
    A liquid-phase microextraction coupled with LC method has been developed for the determination of organophosphorus pesticides (methidation, quinalphos and profenofos) in drinking water samples. In this method, a small amount (3 microL) of isooctane as the acceptor phase was introduced continually to fill-up the channel of a 1.5 cm polypropylene hollow fiber using a microsyringe while the hollow fiber was immersed in an aqueous donor solution. A portion of the acceptor phase (ca. 0.4 microL) was first introduced into the hollow fiber and additional amounts (ca. 0.2 microL) of the acceptor phase were introduced to replenish at intervals of 3 min until set end of extraction (40 min). After extraction, the acceptor phase was withdrawn and transferred into a 2 mL vial for a drying step prior to injection into a LC system. Parameters that affect the extraction efficiency were studied including the organic solvent, length of fiber, volume of acceptor and donor phase, stirring rate, extraction time, and effect of salting out. The proposed method provided good enrichment factors of up to 189.50, with RSD ranging from 0.10 to 0.29%, analyte recoveries of over 79.80% and good linearity ranging from 10.0 to 1.25 mg/L. The LOD ranged from 2.86 to 82.66 microg/L. This method was applied successfully to the determination of organophosphorus pesticides in selected drinking water samples.
    Matched MeSH terms: Chromatography, High Pressure Liquid/instrumentation*; Chromatography, High Pressure Liquid/methods*
  8. Rafidah HM, Azizi A, Noriah MN
    Med J Malaysia, 2006 Jun;61(2):189-98.
    PMID: 16898310 MyJurnal
    Apart from the mean 24 hour ambulatory blood pressure (ABP), the blood pressure variability (BPV) also bears an independent relationship with target-organ damage in hypertension. A reduction in arterial compliance has been demonstrated in hypertension but its relation to BPV is still unknown. The aim of the study is to compare BPV and arterial compliance between hypertensive and normotensive subjects. Eighteen hypertensives and 18 controls were enrolled. Noninvasive 24-hour ABP monitoring was performed with BR-102 monitor (Schiller Inc. Germany). Arterial compliance was determined by the HDI/Pulsewave Research Cardiovascular Profiling Instrument (Hypertension Diagnostic Inc. USA). There were significantly higher systolic, diastolic and mean arterial BPV in hypertensives as compared to normotensive group. Only systolic BPV remained significantly high in hypertensives during night time. There were lower arterial compliances in hypertensive as compared to normotensive group. No significant relationship however was found between BPV and arterial compliance in hypertensive subjects. In conclusion, there were higher BPV and lower arterial compliances in hypertensive subjects as compared to normotensive subjects.
    Matched MeSH terms: Blood Pressure/physiology*; Blood Pressure Monitoring, Ambulatory
  9. Yeo CK, Hapizah MN, Khalid BAK, Wan Nazainimoon WM, Khalid Y
    Med J Malaysia, 2004 Jun;59(2):185-9.
    PMID: 15559168
    Diabetes mellitus is an important coronary artery disease risk factor. The presence of microalbuminuria, which indicates renal involvement in diabetic patients, is associated with an increased cardiovascular risk. There are suggestions that diabetic patients with microalbuminuria have more adverse risk profile such as higher ambulatory blood pressure and total cholesterol levels to account for the increased cardiovascular morbidity and mortality. QT dispersion is increasingly being recognized as a prognostic factor for coronary artery disease and sudden death. Some studies have suggested that QT dispersion is an important predictor of mortality in Type II diabetic patients. Our cross sectional study was to compare the QT dispersion and 24 hour ambulatory blood pressure monitoring between diabetic patients with microalbuminuria and those without microalbuminuria. Diabetic patients with overt coronary artery disease were excluded from the study. A total of 108 patients were recruited of which 57 patients had microalbuminuria and 51 were without microalbuminuria. The mean value of QT dispersion was significantly higher in patients with microalbuminuria than in patients without microalbuminuria (58.9 +/- 27.9 ms vs. 47.1 +/- 25.0 ms, p < 0.05). The mean 24 hour systolic and diastolic blood pressures were significantly higher in patients with microalbuminuria than in patients without microalbuminuria (129.5 +/- 12.3 mm Hg vs 122.3 +/- 10.2 mm Hg, p < 0.05 and 78.4 +/- 6.9 mm Hg vs 75.3 +/- 6.8 mm Hg, p < 0.05, respectively). Our study suggests that QT dispersion prolongation, related perhaps to some autonomic dysfunction, is an early manifestation of cardiovascular aberration in diabetic patients with microalbuminuria. The higher blood pressure levels recorded during a 24-hour period min diabetics with microalbuminuria could also possibly account for the worse cardiovascular outcome in this group of patients.
    Matched MeSH terms: Blood Pressure*; Blood Pressure Monitoring, Ambulatory
  10. Samsudin A, Eames I, Brocchini S, Khaw PT
    J Glaucoma, 2016 Jan;25(1):e39-45.
    PMID: 25719236 DOI: 10.1097/IJG.0000000000000243
    PURPOSE: ExPress devices are available as P50 and P200 models, the numbers related to their luminal diameters in μm. We compared their Poiseuille's Law-based theoretical resistance values with experimental values and correlated these with their luminal dimensions derived from electron microscopy.

    METHODS: Scanning electron microscopy was performed on P50 and P200 devices. Bench-top flow studies were performed to find the resistances of the devices. Devices were also incorporated into a perfused, ex vivo porcine sclera model to test and compare their control of pressure, with and without overlying scleral flaps, and with trabeculectomies.

    RESULTS: The luminal dimensions of the P200 device were 206.4±3.3 and 204.5±0.9 μm at the subconjunctival space and anterior chamber ends, respectively. Those of the P50 device were 205.0±5.8 and 206.9±3.7 μm, respectively. There were no significant differences between the P200 and P50 devices (all P>0.05). The resistances of the P200 and P50 devices were 0.010±0.001 and 0.054±0.002 mm Hg/μL/min, respectively (P<0.05). Equilibrium pressures with overlying scleral flaps were 17.81±3.30 mm Hg for the P50, 17.31±4.24 mm Hg for the P200, and 16.28±6.67 mm Hg for trabeculectomies (P=0.850).

    CONCLUSIONS: The luminal diameters of both devices are externally similar. The effective luminal diameter of the P50 is much larger than 50 μm. Both devices have low resistance values, making them unlikely to prevent hypotony on their own. They lead to similar equilibrium pressures as the trabeculectomy procedure when inserted under the scleral flap.

    Matched MeSH terms: Intraocular Pressure/physiology; Pressure
  11. Abdullah B, Khong SY, Tan PC
    Int Urogynecol J, 2016 Jul;27(7):1057-62.
    PMID: 26718780 DOI: 10.1007/s00192-015-2930-3
    INTRODUCTION: Cervicovaginal decubitus ulceration is a well-known complication of advanced pelvic organ prolapse (POP). There is no consensus for its management. This case series describes the outcome of using repeated vaginal packs soaked with oestrogen cream to reduce POP and promote decubitus ulcer healing. We aimed to investigate the speed of ulcer healing and endometrial safety with this regimen.

    METHODS: This was a retrospective study of patients with stage 3 or 4 POP and intact uterus with decubitus ulcer who were planned for surgery that included hysterectomy after ulcer healing. Vaginal packs are replaced at least biweekly-or more frequently if extruded-until ulcer resolution.

    RESULTS: Thirteen patients were studied. Mean age was 69 ± 6 years and mean duration of menopause was 19 ± 6 years. Nine patients had a single ulcer and four had multiple ulcers. Mean ulcer diameter was 2.8 ± 1.5 cm and mean duration for ulcer healing was 26 ± 14 days. Hysterectomy and pelvic floor reconstruction was performed a median of 5 (range 0-153) days after ulcer healing was first noted. Histopathological examination of the endometrium following hysterectomy showed three specimens with endocervical hyperplasia; one had concurrent proliferative endometrium, two had simple endometrial hyperplasia and another two had proliferative endometrium.

    CONCLUSION: Oestrogen-soaked vaginal packing is a viable option for managing a decubitus ulcer in advanced POP. We document a measurable impact on the endometrium with this short-term preoperative regimen. Further research is needed to evaluate its efficacy in promoting ulcer healing and endometrial safety.

    Matched MeSH terms: Pressure Ulcer/etiology; Pressure Ulcer/therapy*
  12. Mahfoud F, Mancia G, Schmieder RE, Ruilope L, Narkiewicz K, Schlaich M, et al.
    J Am Coll Cardiol, 2022 Nov 15;80(20):1871-1880.
    PMID: 36357087 DOI: 10.1016/j.jacc.2022.08.802
    BACKGROUND: Renal denervation (RDN) has been shown to lower blood pressure (BP), but its effects on cardiovascular events have only been preliminarily evaluated. Time in therapeutic range (TTR) of BP is associated with cardiovascular events.

    OBJECTIVES: This study sought to assess the impact of catheter-based RDN on TTR and its association with cardiovascular outcomes in the GSR (Global SYMPLICITY Registry).

    METHODS: Patients with uncontrolled hypertension were enrolled and treated with radiofrequency RDN. Office and ambulatory systolic blood pressure (OSBP and ASBP) were measured at 3, 6, 12, 24, and 36 months postprocedure and used to derive TTR. TTR through 6 months was assessed as a predictor of cardiovascular events from 6 to 36 months using a Cox proportional hazard regression model.

    RESULTS: As of March 1, 2022, 3,077 patients were enrolled: 42.2% were female; mean age was 60.5 ± 12.2 years; baseline OSBP was 165.6 ± 24.8 mm Hg; and baseline ASBP was 154.3 ± 18.7 mm Hg. Patients were prescribed 4.9 ± 1.7 antihypertensive medications at baseline and 4.8 ± 1.9 at 36 months. At 36 months, mean changes were -16.7 ± 28.4 and -9.0 ± 20.2 mm Hg for OSBP and ASBP, respectively. TTR through 6 months was 30.6%. A 10% increase in TTR after RDN through 6 months was associated with significant risk reductions from 6 to 36 months of 15% for major adverse cardiovascular events (P < 0.001), 11% cardiovascular death (P = 0.010), 15% myocardial infarction (P = 0.023), and 23% stroke (P < 0.001).

    CONCLUSIONS: There were sustained BP reductions and higher TTR through 36 months after RDN. A 10% increase in TTR through 6 months was associated with significant risk reductions in major cardiovascular events from 6 to 36 months. (Global SYMPLICITY Registry [GSR] DEFINE; NCT01534299).

    Matched MeSH terms: Blood Pressure/physiology; Blood Pressure Monitoring, Ambulatory
  13. Wong WJ, Nguyen TV, Ahmad F, Vu HTT, Koh AS, Tan KM, et al.
    J Clin Hypertens (Greenwich), 2025 Jan;27(1):e14936.
    PMID: 39545715 DOI: 10.1111/jch.14936
    Diabetes is one of the most pressing health issues in the Southeast Asian region, and hypertension has been commonly reported as a comorbidity in adults with diabetes. This systematic review aimed to synthesize evidence on the prevalence and management of hypertension in adults with diabetes in Southeast Asian countries. A literature search was conducted in Ovid MEDLINE and Embase Classic + Embase from database inception until March 15, 2024. Studies were included if (1) they were conducted in Southeast Asian countries, (2) the study populations were adults with diabetes, and (3) there was information related to hypertension or blood pressure (BP) in the study results. Of the 7486 abstracts found, 90 studies qualified for this review. Most studies reported a hypertension prevalence of 70% or higher (ranging from 29.4% to 93.4%). Despite this high prevalence, a substantial proportion of these populations did not receive adequate BP control, with most studies indicating a control rate of less than 40%. There was limited evidence on the prescription of antihypertensive therapies and medication adherence. There was a lack of studies from 4 of the 11 countries in the region. This review highlights that BP control in adults with diabetes remains a significant challenge in Southeast Asia. Given the ongoing epidemiological transition, and the increasing older population in this region who are likely to accumulate multiple chronic conditions complicating medication strategies, this review highlights the urgent need to improve BP management in those with diabetes.
    Matched MeSH terms: Blood Pressure/drug effects; Blood Pressure/physiology
  14. Lim HM, Chia YC, Ching SM, Chinna K
    BMJ Open, 2019 Apr 20;9(4):e025322.
    PMID: 31005918 DOI: 10.1136/bmjopen-2018-025322
    OBJECTIVE: To determine the reproducibility of visit-to-visit blood pressure variability (BPV) in clinical practice. We also determined the minimum number of blood pressure (BP) measurements needed to estimate long-term visit-to-visit BPV for predicting 10-year cardiovascular (CV) risk.

    DESIGN: Retrospective study SETTING: A primary care clinic in a university hospital in Malaysia.

    PARTICIPANTS: Random sampling of 1403 patients aged 30 years and above without any CV event at baseline.

    OUTCOMES MEASURES: The effect of the number of BP measurement for calculation of long-term visit-to-visit BPV in predicting 10-year CV risk. CV events were defined as fatal and non-fatal coronary heart disease, fatal and non-fatal stroke, heart failure and peripheral vascular disease.

    RESULTS: The mean 10-year SD of systolic blood pressure (SBP) for this cohort was 13.8±3.5 mm Hg. The intraclass correlation coefficient (ICC) for the SD of SBP based on the first eight and second eight measurements was 0.38 (p<0.001). In a primary care setting, visit-to-visit BPV (SD of SBP calculated from 20 BP measurements) was significantly associated with CV events (adjusted OR 1.07, 95% CI 1.02 to 1.13, p=0.009). Using SD of SBP from 20 measurement as reference, SD of SBP from 6 measurements (median time 1.75 years) has high reliability (ICC 0.74, p<0.001), with a mean difference of 0.6 mm Hg. Hence, a minimum of six BP measurements is needed for reliably estimating intraindividual BPV for CV outcome prediction.

    CONCLUSION: Long-term visit-to-visit BPV is reproducible in clinical practice. We suggest a minimum of six BP measurements for calculation of intraindividual visit-to-visit BPV. The number and duration of BP readings to derive BPV should be taken into consideration in predicting long-term CV risk.

    Matched MeSH terms: Blood Pressure/physiology*; Blood Pressure Determination/methods; Blood Pressure Determination/statistics & numerical data*
  15. Abougalambou SS, Abougalambou AS
    Diabetes Metab Syndr, 2013 Apr-Jun;7(2):83-6.
    PMID: 23680246 DOI: 10.1016/j.dsx.2013.02.019
    INTRODUCTION: Hypertension is extremely common disease found in patients with diabetes mellitus. Eighty to 90% of patients with type 2 diabetes mellitus will develop hypertension, and about 20% of hypertensive patients develop diabetes. The aim of this study was designed to assess the prevalence of hypertension and factors affecting the control of hypertension among type 2 diabetic patients.
    MATERIALS AND METHODS: A total of 1077 type 2 diabetes mellitus patients were included in this study who attended at diabetes clinic of Universiti Sains Malaysia (USM) teaching hospital in Kelantan. All these patients were prospectively followed from January to December 2008. Logistic regression analysis was used to assess the independent effect of variables on hypertension.
    RESULTS: The prevalence of hypertension (BP>130/80 or on medication for high blood pressure) was 92.7%. A total 471 (47.2%) patients had achieved blood pressure targets ≤ 130/80 mmHg. The logistic regression indicated that hypertension was positively associated with age (P=0.040), BMI (P=0.027), HbA1c (P=0.046), and level of education (P=0.039).
    CONCLUSION: Hypertension is a common co-morbidity among diabetic patients. Hypertension was not controlled to the recommended levels of blood pressure in about one-half (52.8%) of diabetes patients. Age, BMI, HbA1c and level of education are factors affecting on hypertension.
    Matched MeSH terms: Blood Pressure/physiology*; Blood Pressure Determination/methods; Blood Pressure Determination/standards*
  16. Goh CH, Ng SC, Kamaruzzaman SB, Chin AV, Poi PJ, Chee KH, et al.
    Medicine (Baltimore), 2016 May;95(19):e3614.
    PMID: 27175670 DOI: 10.1097/MD.0000000000003614
    To evaluate the utility of blood pressure variability (BPV) calculated using previously published and newly introduced indices using the variables falls and age as comparators.While postural hypotension has long been considered a risk factor for falls, there is currently no documented evidence on the relationship between BPV and falls.A case-controlled study involving 25 fallers and 25 nonfallers was conducted. Systolic (SBPV) and diastolic blood pressure variability (DBPV) were assessed using 5 indices: standard deviation (SD), standard deviation of most stable continuous 120 beats (staSD), average real variability (ARV), root mean square of real variability (RMSRV), and standard deviation of real variability (SDRV). Continuous beat-to-beat blood pressure was recorded during 10 minutes' supine rest and 3 minutes' standing.Standing SBPV was significantly higher than supine SBPV using 4 indices in both groups. The standing-to-supine-BPV ratio (SSR) was then computed for each subject (staSD, ARV, RMSRV, and SDRV). Standing-to-supine ratio for SBPV was significantly higher among fallers compared to nonfallers using RMSRV and SDRV (P = 0.034 and P = 0.025). Using linear discriminant analysis (LDA), 3 indices (ARV, RMSRV, and SDRV) of SSR SBPV provided accuracies of 61.6%, 61.2%, and 60.0% for the prediction of falls which is comparable with timed-up and go (TUG), 64.4%.This study suggests that SSR SBPV using RMSRV and SDRV is a potential predictor for falls among older patients, and deserves further evaluation in larger prospective studies.
    Matched MeSH terms: Blood Pressure/physiology*; Blood Pressure Determination/methods; Blood Pressure Determination/statistics & numerical data*
  17. Writing Group for the Alveolar Recruitment for Acute Respiratory Distress Syndrome Trial (ART) Investigators, Cavalcanti AB, Suzumura ÉA, Laranjeira LN, Paisani DM, Damiani LP, et al.
    JAMA, 2017 10 10;318(14):1335-1345.
    PMID: 28973363 DOI: 10.1001/jama.2017.14171
    Importance: The effects of recruitment maneuvers and positive end-expiratory pressure (PEEP) titration on clinical outcomes in patients with acute respiratory distress syndrome (ARDS) remain uncertain.

    Objective: To determine if lung recruitment associated with PEEP titration according to the best respiratory-system compliance decreases 28-day mortality of patients with moderate to severe ARDS compared with a conventional low-PEEP strategy.

    Design, Setting, and Participants: Multicenter, randomized trial conducted at 120 intensive care units (ICUs) from 9 countries from November 17, 2011, through April 25, 2017, enrolling adults with moderate to severe ARDS.

    Interventions: An experimental strategy with a lung recruitment maneuver and PEEP titration according to the best respiratory-system compliance (n = 501; experimental group) or a control strategy of low PEEP (n = 509). All patients received volume-assist control mode until weaning.

    Main Outcomes and Measures: The primary outcome was all-cause mortality until 28 days. Secondary outcomes were length of ICU and hospital stay; ventilator-free days through day 28; pneumothorax requiring drainage within 7 days; barotrauma within 7 days; and ICU, in-hospital, and 6-month mortality.

    Results: A total of 1010 patients (37.5% female; mean [SD] age, 50.9 [17.4] years) were enrolled and followed up. At 28 days, 277 of 501 patients (55.3%) in the experimental group and 251 of 509 patients (49.3%) in the control group had died (hazard ratio [HR], 1.20; 95% CI, 1.01 to 1.42; P = .041). Compared with the control group, the experimental group strategy increased 6-month mortality (65.3% vs 59.9%; HR, 1.18; 95% CI, 1.01 to 1.38; P = .04), decreased the number of mean ventilator-free days (5.3 vs 6.4; difference, -1.1; 95% CI, -2.1 to -0.1; P = .03), increased the risk of pneumothorax requiring drainage (3.2% vs 1.2%; difference, 2.0%; 95% CI, 0.0% to 4.0%; P = .03), and the risk of barotrauma (5.6% vs 1.6%; difference, 4.0%; 95% CI, 1.5% to 6.5%; P = .001). There were no significant differences in the length of ICU stay, length of hospital stay, ICU mortality, and in-hospital mortality.

    Conclusions and Relevance: In patients with moderate to severe ARDS, a strategy with lung recruitment and titrated PEEP compared with low PEEP increased 28-day all-cause mortality. These findings do not support the routine use of lung recruitment maneuver and PEEP titration in these patients.

    Trial Registration: clinicaltrials.gov Identifier: NCT01374022.

    Matched MeSH terms: Positive-Pressure Respiration/adverse effects; Positive-Pressure Respiration/methods*
  18. Shao M, Hussain Z, Thu HE, Khan S, de Matas M, Silkstone V, et al.
    Crit Rev Ther Drug Carrier Syst, 2017;34(5):387-452.
    PMID: 29256838 DOI: 10.1615/CritRevTherDrugCarrierSyst.2017016957
    Chronic wounds which include diabetic foot ulcer (DFU), pressure ulcer, and arterial or venous ulcers compel a significant burden to the patients, healthcare providers, and the healthcare system. Chronic wounds are characterized by an excessive persistent inflammatory phase, prolonged infection, and the failure of defense cells to respond to environmental stimuli. Unlike acute wounds, chronic nonhealing wounds pose a substantial challenge to conventional wound dressings, and the development of novel and advanced wound healing modalities is needed. Toward this end, numerous conventional wound-healing modalities have been evaluated in the management of nonhealing wounds, but a multifaceted approach is lacking. Therefore, this review aims to compile and explore the wide therapeutic algorithm of current and advanced wound healing approaches to the treatment of chronic wounds. The algorithm of chronic wound healing techniques includes conventional wound dressings; approaches based on autografts, allografts, and cultured epithelial autografts; and recent modalities based on natural, modified or synthetic polymers and biomaterials, processed mutually in the form of hydrogels, films, hydrocolloids, and foams. Moreover, this review also explores the promising potential of advanced drug delivery systems for the sustained delivery of growth factors, curcumin, aloe vera, hyaluronic acid, and other bioactive substances as well as stem cell therapy. The current review summarizes the convincing evidence for the clinical dominance of polymer-based chronic wound healing modalities as well as the latest and innovative therapeutic strategies for the treatment of chronic wounds.
    Matched MeSH terms: Pressure Ulcer/drug therapy; Pressure Ulcer/therapy*
  19. Manosroi W, Tan JW, Rariy CM, Sun B, Goodarzi MO, Saxena AR, et al.
    J Clin Endocrinol Metab, 2017 11 01;102(11):4124-4135.
    PMID: 28938457 DOI: 10.1210/jc.2017-00957
    Context: Hypertension in young women is uncommon compared with young men and older women. Estrogen appears to protect most women against hypertension, with incidence increasing after menopause. Because some premenopausal women develop hypertension, estrogen may play a different role in these women. Genetic variations in the estrogen receptor (ER) are associated with cardiovascular disease. ER-β, encoded by ESR2, is the ER predominantly expressed in vascular smooth muscle.

    Objective: To determine an association of single nucleotide polymorphisms in ESR2 with salt sensitivity of blood pressure (SSBP) and estrogen status in women.

    Methods: Candidate gene association study with ESR2 and SSBP conducted in normotensive and hypertensive women and men in two cohorts: International Hypertensive Pathotype (HyperPATH) (n = 584) (discovery) and Mexican American Hypertension-Insulin Resistance Study (n = 662) (validation). Single nucleotide polymorphisms in ESR1 (ER-α) were also analyzed. Analysis conducted in younger (<51 years, premenopausal, "estrogen-replete") and older women (≥51 years, postmenopausal, "estrogen-deplete"). Men were analyzed to control for aging.

    Results: Multivariate analyses of HyperPATH data between variants of ESR2 and SSBP documented that ESR2 rs10144225 minor (risk) allele carriers had a significantly positive association with SSBP driven by estrogen-replete women (β = +4.4 mm Hg per risk allele, P = 0.004). Findings were confirmed in Hypertension Insulin-Resistance Study premenopausal women. HyperPATH cohort analyses revealed risk allele carriers vs noncarriers had increased aldosterone/renin ratios. No associations were detected with ESR1.

    Conclusions: The variation at rs10144225 in ESR2 was associated with SSBP in premenopausal women (estrogen-replete) and not in men or postmenopausal women (estrogen-deplete). Inappropriate aldosterone levels on a liberal salt diet may mediate the SSBP.

    Matched MeSH terms: Blood Pressure/drug effects; Blood Pressure/genetics
  20. Eng CSY, Bhowruth D, Mayes M, Stronach L, Blaauw M, Barber A, et al.
    Nephrol Dial Transplant, 2018 05 01;33(5):847-855.
    PMID: 29136192 DOI: 10.1093/ndt/gfx287
    Background: Fluid balance is pivotal in the management of children with chronic kidney disease (CKD) and on dialysis. Although many techniques are available to assess fluid status, there are only a few studies for children, of which none have been comparable against cardiovascular outcome measures.

    Methods: We performed a longitudinal study in 30 children with CKD5-5D and 13 age-matched healthy controls (71 measurements) to determine a correlation between optimal weight by bioimpedance spectroscopy (Wt-BIS) and clinical assessment (Wt-CA). The accuracy of Wt-BIS [relative overhydration (Rel-OH)] was compared against indicators of fluid status and cardiovascular measures.

    Results: There was poor agreement between Wt-CA and Wt-BIS in children on dialysis (P = 0.01), but not in CKD5 or control subjects. We developed a modified chart to plot Rel-OH against systolic blood pressure (SBP) z-score for the appropriate representation of volume status and blood pressure (BP) in children. In total, 25% of measurements showed SBP >90th percentile but not with concurrent overhydration. Rel-OH correlated with peripheral pulse pressure (P = 0.03; R = 0.3), higher N-terminal pro-brain natriuretic peptide (P = 0.02; R = 0.33) and left ventricular end-diastolic diameter (P = 0.05; R = 0.38). Central aortic mean and pulse pressure significantly associated with the left ventricular end-diastolic diameter (P = 0.03; R = 0.47 and P = 0.01; R = 0.50, respectively), but not with Rel-OH. SBP was positively associated with pulse wave velocity z-score (P = 0.04). In total, 40% of children on haemodialysis and 30% on peritoneal dialysis had increased left ventricular mass index.

    Conclusions: BIS provides an objective method for the assessment of hydration status in children on dialysis. We noted a marked discrepancy between BP and hydration status in children on dialysis that warrants further investigation.

    Matched MeSH terms: Blood Pressure*; Blood Pressure Determination