Displaying publications 21 - 40 of 49 in total

Abstract:
Sort:
  1. Nishi SE, Basri R, Rahman NA, Husein A, Alam MK
    J Orthod Sci, 2018;7:3.
    PMID: 29765915 DOI: 10.4103/jos.JOS_74_17
    OBJECTIVES: The aim of the study was to assess the association and correlation between the overjet and muscle activity (the masseter and temporalis muscles) in patient with Class II malocclusion in different genders using surface electromyography (sEMG).

    MATERIALS AND METHODS: The overjet (measured clinically) and electromyographical activity (rest, chew, post chew rest, clench and post clench rest) of the masseter and temporalis muscle of class II malocclusion patient were assessed in 18 patients (3 males and 15 females) from the School of Dental Science, Hospital University Sains Malaysia.

    RESULTS: The results were compared by simple linear regression test to evaluate the association between overjet and muscle activity in different genders. Class II malocclusion patients with increased overjet group showed significant association with masseter muscle activity on chewing stage (P = 0.005, F = 6.081 and adj-R2 = 0.473). Left temporalis muscle in class II malocclusion showed a significant linear association (P = 0.014, F = 0.812 and adj-R2= -0.034) with gender during clench.

    CONCLUSION: In conclusion, class II malocclusion patient with increased overjet can affect masticatory muscle function and as well as clench force may differ in gender.

  2. Rahman AM, Jamayet NB, Nizami MMUI, Johari Y, Husein A, Alam MK
    J Prosthodont, 2019 Jan;28(1):36-48.
    PMID: 30043482 DOI: 10.1111/jopr.12950
    PURPOSE: This systematic review aims to identify and interpret results of studies that evaluated the changes in the physical properties of maxillofacial prosthetic materials (1) without aging, (2) after natural or artificial accelerated aging, and (3) after outdoor weathering.

    METHODS: Relevant articles written in English only, before January 15, 2017, were identified using an electronic search in the PubMed, Scopus, and Google Scholar databases. Furthermore, a manual search of the related major journals was also conducted to identify more pertinent articles. The relevancy of the articles was verified by screening the title, abstract, and full text if they met the inclusion criteria. A total of 37 articles satisfied the criteria, from which data were extracted for qualitative synthesis.

    RESULTS: Among the 37 included articles, 14 were without aging, 15 were natural or artificial accelerated aging, 7 were outdoor weathering, and 1 contained both artificial aging and outdoor weathering. Only 4 studies out of the 14 without aging had significant observations; whereas 9 articles with natural or artificial aging published significant results, and 3 out of 7 outdoor weathering articles showed significant changes in the evaluated silicone elastomers.

    CONCLUSIONS: Despite the varying research, it seems that the single "ideal" maxillofacial prosthetic material that can provide sufficient resistance against different aging conditions is yet to be identified. Therefore, it is imperative for standardization organizations, the scientific community, and academia to develop modified prosthetic silicones possessing improved physical properties and color stability, limiting the clinical problems regarding degradation of maxillofacial prostheses.

  3. Subhi H, Reza F, Husein A, Al Shehadat SA, Nurul AA
    Int J Biomater, 2018;2018:3804293.
    PMID: 30147725 DOI: 10.1155/2018/3804293
    Effective pulp capping material must be biocompatible and have the ability to induce dentin bridge formation as well as having suitable physical and mechanical properties; however, many current materials do not satisfy the clinical requirements. This study aimed to assess the physical and mechanical properties of gypsum-based chitosan material (Gp-CT) and to evaluate its effects on cellular properties of stem cells from human exfoliated deciduous teeth (SHED). The experimental material was prepared with different concentrations of chitosan (CT) with or without BMP-2. Then, setting time, compressive strength, and pH were determined. In addition, cell viability, alkaline phosphatase (ALP) activity, and cell attachment were assessed. The setting time, compressive strength, and pH obtained were 4.1-6.6 min, 2.63-5.83 MPa, and 6.5-5.7, respectively. The cell viability to gypsum (Gp) with different CT concentrations was similar to that of the control on day 1 but statistically different from that of Gp alone on day 3. The ALP activity of SHED was significantly higher (p < 0.05) in CT- and BMP-2-containing materials than those in the control and Dycal at days 3 and 14. The scanning electron microscopy (SEM) image revealed that flattened cells were distributed across and adhered to the material surface. In conclusion, Gp-CT material shows promise as a potential material for direct pulp capping.
  4. Jamayet NB, Rahman AM, Nizami MMUI, Johari Y, Husein A
    Indian J Dent Res, 2018 12 28;29(6):840-843.
    PMID: 30589017 DOI: 10.4103/ijdr.IJDR_20_17
    Exenteration surgery greatly affects a person in terms of function, esthetics, and psychological trauma. In such cases, restoration by silicone orbital prosthesis is a well-accepted treatment option. However, this is a difficult task, necessitating personalized design of method for each patient. This case report describes the technique for fabrication of a silicone orbital prosthesis for a male patient with left orbital defect due to exenteration of a Grade 3 squamous cell carcinoma of the left eye and surrounding tissues. The patient was delivered with a satisfactory silicone orbital prosthesis having good retention and finish. Multidisciplinary management and team approach are crucial in providing precise and effective rehabilitation for improving the patient's quality of life and help them return to their normal social life.
  5. Rahman AM, Jamayet NB, Nizami MMUI, Johari Y, Husein A, Alam MK
    J Prosthet Dent, 2021 Jan 17.
    PMID: 33472753 DOI: 10.1016/j.prosdent.2020.07.026
    STATEMENT OF PROBLEM: The climate of tropical Southeast Asia includes high humidity and ultraviolet radiation that reduce the lifespan of silicone prostheses by inducing changes in their mechanical properties and color stability. Studies on the surface roughness (SR) and mechanical properties of different silicone elastomers (SEs) subjected to the natural tropical weather of Southeast Asia are lacking.

    PURPOSE: The purpose of this in vitro study was to evaluate the SR, tensile strength (TS), and percentage elongation (% E) of different SEs subjected to outdoor weathering in the Malaysian climate.

    MATERIAL AND METHODS: Type-II dumbbell-shaped specimens (N-120) (nonweathered=15, weathered=15) were made from 3 room-temperature vulcanized (A-2000, A-2006, and A-103) and 1 heat-temperature vulcanized (M-511) silicone (Factor II). For 6 months, weathered specimens were subjected to outdoor weathering inside a custom exposure rack. Simultaneously, the nonweathered specimens were kept in a dehumidifier. Subsequently, the SR was measured with a profilometer; TS and % E were measured by using a universal testing machine. Two-way ANOVA was used to compare the means of the tested properties of the nonweathered and weathered specimens, and pairwise comparison was carried out between the silicones (α=.05).

    RESULTS: After outdoor weathering, the SR, TS, and % E were adversely affected by weathering in the Malaysian environment. Among the silicone materials, A-2000 showed the least TS changes (2.51 MPa), while A-2006 demonstrated significant changes in percentage elongation after outdoor weathering (266.5%). M-511 exhibited the highest mean value (2.50 μm) for SR changes. In addition, A-103 SE showed statistically significant differences in most pairwise comparisons for all 3 dependent variables.

    CONCLUSIONS: Based on the evaluation of mechanical properties, A-103 can be suggested as a suitable silicone for maxillofacial prostheses fabricated for tropical climates. However, A-2000 can be a suitable alternative, although significant changes to surface roughness were detected after outdoor weathering.

  6. Mousa MA, Abdullah JY, Jamayet NB, Alam MK, Husein A
    Biomed Res Int, 2021;2021:6419774.
    PMID: 34447852 DOI: 10.1155/2021/6419774
    Aim: This systematic review is aimed at investigating the biomechanical stress that develops in the maxillofacial prostheses (MFP) and supporting structures and methods to optimize it. Design and Methods. A literature survey was conducted for full-text English articles which used FEA to examine the stress developed in conventional and implant-assisted MFPs from January 2010 to December 2020.

    Results: 87 articles were screened to get an update on the desired information. 74 were excluded based on a complete screening, and finally, 13 articles were recruited for complete reviewing. Discussion. The MFP is subjected to stress, which is reflected in the form of compressive and tensile strengths. The stress is mainly concentrated the resection line and around the apices of roots of teeth next to the defect. Diversity of designs and techniques were introduced to optimize the stress distribution, such as modification of the clasp design, using materials with different mechanical properties for dentures base and retainer, use of dental (DI) and/or zygomatic implants (ZI), and free flap reconstruction before prosthetic rehabilitation.

    Conclusion: Using ZI in the defective side of the dentulous maxillary defect and defective and nondefective side of the edentulous maxillary defect was found more advantageous, in terms of compression and tensile stress and retention, when compared with DI and free flap reconstruction.

  7. Mousa MA, Abdullah JY, Jamayet NB, El-Anwar MI, Ganji KK, Alam MK, et al.
    Biomed Res Int, 2021;2021:5699962.
    PMID: 34485518 DOI: 10.1155/2021/5699962
    The present study was aimed at reviewing the studies that used finite element analysis (FEA) to estimate the biomechanical stress arising in removable partial dentures (RPDs) and how to optimize it. A literature survey was conducted for the English full-text articles, which used only FEA to estimate the stress developed in RPDs from Jan 2000 to May 2021. In RPDs, the retaining and supporting structures are subjected to dynamic loads during insertion and removal of the prosthesis as well as during function. The majority of stresses in free-end saddle (FES) RPDs are concentrated in the shoulder of the clasp, the horizontal curvature of the gingival approaching clasp, and the part of the major connector next to terminal abutments. Clasps fabricated from flexible materials were beneficial to eliminate the stress in the abutment, while rigid materials were preferred for major connectors to eliminate the displacement of the prosthesis. In implant-assisted RPD, the implant receive the majority of the load, thereby reducing the stress on the abutment and reducing the displacement of the prosthesis. The amount of stress in the implant decreases with zero or minimal angulation, using long and wide implants, and when the implants are placed in the first molar area.
  8. Subhi H, Husein A, Mohamad D, Nik Abdul Ghani NR, Nurul AA
    Polymers (Basel), 2021 Sep 30;13(19).
    PMID: 34641172 DOI: 10.3390/polym13193358
    Calcium silicate-based cements (CSCs) are widely used in various endodontic treatments to promote wound healing and hard tissue formation. Chitosan-based accelerated Portland cement (APC-CT) is a promising and affordable material for endodontic use. This study investigated the effect of APC-CT on apoptosis, cell attachment, dentinogenic/osteogenic differentiation and mineralization activity of stem cells from human exfoliated deciduous teeth (SHED). APC-CT was prepared with various concentrations of chitosan (CT) solution (0%, 0.625%, 1.25% and 2.5% (w/v)). Cell attachment was determined by direct contact analysis using field emission scanning electron microscopy (FESEM); while the material extracts were used for the analyses of apoptosis by flow cytometry, dentinogenic/osteogenic marker expression by real-time PCR and mineralization activity by Alizarin Red and Von Kossa staining. The cells effectively attached to the surfaces of APC and APC-CT, acquiring flattened elongated and rounded-shape morphology. Treatment of SHED with APC and APC-CT extracts showed no apoptotic effect. APC-CT induced upregulation of DSPP, MEPE, DMP-1, OPN, OCN, OPG and RANKL expression levels in SHED after 14 days, whereas RUNX2, ALP and COL1A1 expression levels were downregulated. Mineralization assays showed a progressive increase in the formation of calcium deposits in cells with material containing higher CT concentration and with incubation time. In conclusion, APC-CT is nontoxic and promotes dentinogenic/osteogenic differentiation and mineralization activity of SHED, indicating its regenerative potential as a promising substitute for the commercially available CSCs to induce dentin/bone regeneration.
  9. Nishi SE, Rahman NA, Basri R, Alam MK, Noor NFM, Zainal SA, et al.
    Biomed Res Int, 2021;2021:6642254.
    PMID: 33969121 DOI: 10.1155/2021/6642254
    Objective: This pre-post study is aimed at determining the effects of masticatory muscle activity (masseter and temporalis) measured via sEMG between conventional, self-ligating, and ceramic bracket after six months of orthodontic treatment.

    Methods: A total of eighteen (18) malocclusion patients were identified. Malocclusion patients were subdivided into 3 groups based on the bracket selection (conventional, self-ligating, and ceramic bracket) with 6 patients for each group. sEMG of muscles were done using a two-channel electromyography device, where pregelled and self-adhesive electrodes (bilateral) were applied. Chewing and clenching of masseter and temporalis muscle activity were recorded for 20 s pre and 6 months of orthodontic treatment using sEMG (frequency 60 Hz). The data were analysed by using repeated measures ANOVA in IBM SPSS Statistics Version 24.0.

    Results: Chewing and clenching for masseter muscle showed no significant difference (P > 0.05) in sEMG activity of three types of the brackets. However, for temporalis muscle, there was a significant difference found in sEMG activity during chewing (P < 0.05) and clenching (P < 0.05) between these three brackets.

    Conclusion: The activity of temporalis muscle showed significant changes in chewing and clenching, where the conventional group demonstrated better muscle activity pre and at six months of fixed appliances.

  10. Qamruddin I, Alam MK, Mahroof V, Fida M, Khamis MF, Husein A
    Pain Res Manag, 2021;2021:6690542.
    PMID: 34055122 DOI: 10.1155/2021/6690542
    Objective: To assess the effect of low-level laser applied at 3 weeks intervals on orthodontic tooth movement (OTM) and pain using conventional brackets (CB).

    Materials and Methods: Twenty patients with Angle's class II div 1 (10 males and 10 females; aged 20.25 ± 3.88 years) needing bilateral extractions of maxillary first bicuspids were recruited. Conventional brackets MBT of 0.022 in slot (McLaughlin Bennett Trevisi) prescription braces (Ortho Organizers, Carlsbad, Calif) were bonded. After alignment and levelling phase, cuspid retraction began with nitinol closed coil spring on 19 × 25 stainless steel archwire, wielding 150 gram force. 7.5 J/cm2 energy was applied on 10 points (5 buccal and 5 palatal) on the canine roots on the investigational side using gallium-aluminum-arsenic diode laser (940 nm wavelength, iLase™ Biolase, Irvine, USA) in a continuous mode. Target tissues were irradiated once in three weeks for 9 weeks at a stretch (T0, T1, and T2). Patients were given a feedback form based on the numeric rating scale (NRS) to record the pain intensity for a week. Silicon impressions preceded the coil activation at each visit (T0, T1, T2, and T3), and the casts obtained were scanned with the Planmeca CAD/CAM™ (Helsinki, Finland) scanner.

    Results: The regimen effectively accelerated (1.55 ± 0.25 mm) tooth movement with a significant reduction in distress on the investigational side as compared to the placebo side (94 ± 0.25 mm) (p < 0.05).

    Conclusions: This study reveals that the thrice-weekly LLLT application can accelerate OTM and reduce the associated pain.

  11. Qamruddin I, Alam MK, Mahroof V, Karim M, Fida M, Khamis MF, et al.
    Pain Res Manag, 2021;2021:6624723.
    PMID: 34035871 DOI: 10.1155/2021/6624723
    Objective: Low-intensity pulsed ultrasound (LIPUS) is a noninvasive modality to stimulate bone remodeling (BR) and the healing of hard and soft tissues. This research evaluates the biostimulatory effect of LIPUS on the rate of orthodontic tooth movement (OTM) and associated pain, when applied at 3-week intervals.

    Methods: Twenty-two patients (11 males and 11 females; mean age 19.18 ± 2.00 years) having Angle's Class II division 1 malocclusion needing bilateral extractions of maxillary first bicuspids were recruited for this split-mouth randomized clinical trial. After the initial stage of alignment and leveling with contemporary edgewise MBT (McLaughlin-Bennett-Trevisi) prescription brackets (Ortho Organizers, Carlsbad, Calif) of 22 mil, followed by extractions of premolars bilaterally, 6 mm nickel-titanium spring was used to retract the canines separately by applying 150 g force on 0.019 × 0.025-in stainless steel working archwires. LIPUS (1.1 MHz frequency and 30 mW/cm2 intensity output) was applied for 20 minutes extraorally and reapplied after 3 weeks for 2 more successive visits over the root of maxillary canine on the experimental side whereas the other side was placebo. A numerical rating scale- (NRS-) based questionnaire was given to the patients on each visit to record their weekly pain experience. Impressions were also made at each visit before the application of LIPUS (T1, T2, and T3). Models were scanned with a CAD/CAM scanner (Planmeca, Helsinki, Finland). Mann-Whitney U test was applied for comparison of canine movement and pain intensity between both the groups.

    Results: No significant difference in the rate of canine movement was found among the experimental (0.90 mm ± 0.33 mm) and placebo groups (0.81 mm ± 0.32 mm). There was no difference in pain reduction between experimental and placebo groups (p > 0.05).

    Conclusion: Single-dose application of LIPUS at 3-week intervals is ineffective in stimulating the OTM and reducing associated treatment pain.

  12. Yap Abdullah J, Manaf Abdullah A, Zaim S, Hadi H, Husein A, Ahmad Rajion Z, et al.
    Proc Inst Mech Eng H, 2024 Jan;238(1):55-62.
    PMID: 37990963 DOI: 10.1177/09544119231212034
    This study aimed to compare the 3D skull models reconstructed from computed tomography (CT) images using three different open-source software with a commercial software as a reference. The commercial Mimics v17.0 software was used to reconstruct the 3D skull models from 58 subjects. Next, two open-source software, MITK Workbench 2016.11, 3D Slicer 4.8.1 and InVesalius 3.1 were used to reconstruct the 3D skull models from the same subjects. All four software went through similar steps in 3D reconstruction process. The 3D skull models from the commercial and open-source software were exported in standard tessellation language (STL) format into CloudCompare v2.8 software and superimposed for geometric analyses. Hausdorff distance (HD) analysis demonstrated the average points distance of Mimics versus MITK was 0.25 mm. Meanwhile, for Mimics versus 3D Slicer and Mimics versus InVesalius, there was almost no differences between the two superimposed 3D skull models with average points distance of 0.01 mm. Based on Dice similarity coefficient (DSC) analysis, the similarity between Mimics versus MITK, Mimics versus 3D Slicer and Mimics versus InVesalius were 94.1, 98.8 and 98.3%, respectively. In conclusion, this study confirmed that the alternative open-source software, MITK, 3D Slicer and InVesalius gave comparable results in 3D reconstruction of skull models compared to the commercial gold standard Mimics software. This open-source software could possibly be used for pre-operative planning in cranio-maxillofacial cases and for patient management in the hospitals or institutions with limited budget.
  13. Hameed HA, Hasan HA, Luddin N, Husein A, Ariffin A, Alam MK
    Biomed Res Int, 2022;2022:3675703.
    PMID: 35496039 DOI: 10.1155/2022/3675703
    AIM: To investigate and compare the cell cytotoxicity, proliferation, cell attachment, and morphology of human fetal osteoblasts (hFOB) cells of coated samples (titanium nanocopper (Ti Cu), titanium nanohydroxyapatite (Ti HA) and titanium nanocopper ion doped hydroxyapatite (Ti Cu/HA) and uncoated samples (Ti) in order to assess the suitability of these surface modifications on Ti-6Al-7Nb for dental implant application.

    MATERIALS AND METHODS: The cytotoxicity was studied by examining the hFOB cell response by MTT assessment. The cell morphology was evaluated by inverted microscopy and observed under scanning electronic microscopy (SEM).

    RESULTS: MTT assay results displayed that the Cu content on the surface of Ti-6Al-7Nb alloys did not produce any cytotoxic effect on cell viability. The cell viability rate in all samples ranges from 97% to 126%, indicating that hFOB cells grew at a high proliferation rate. However, no significant differences in cell viability were observed between Ti and Ti Cu and between Ti HA and Ti Cu/HA groups. Microscopic examination demonstrated no difference in the cell morphology of hFOB among all samples. In addition, SEM observation indicated favorable adhesion and spreading of the cells on the coated and uncoated samples.

    CONCLUSIONS: The surface modification of Ti-6Al-7Nb alloy with Cu, HA, and Cu/HA exhibits good cell biocompatibility, and the Cu has no influence on the cell proliferation and differentiation of hFOB.

  14. Farea M, Husein A, Halim AS, Abdullah NA, Mokhtar KI, Lim CK, et al.
    Arch Oral Biol, 2014 Dec;59(12):1400-11.
    PMID: 25222336 DOI: 10.1016/j.archoralbio.2014.08.015
    Multipotent stem cells derived from human exfoliated deciduous teeth (SHED) represent a promising cell source for tissue regeneration. In the present study we decided to test the inductive effect of chitosan and transforming growth factor-β1 (TGFβ1) as a scaffold/factor combination on SHED proliferation and osteogenic differentiation.
  15. Jawad MM, Husein A, Azlina A, Alam MK, Hassan R, Shaari R
    J Biomed Opt, 2013 Dec;18(12):128001.
    PMID: 24337495 DOI: 10.1117/1.JBO.18.12.128001
    Bone regeneration is essential in medical treatment, such as in surgical bone healing and orthodontics. The aim of this study is to examine the effect of different powers of 940 nm diode low-level laser treatment (LLLT) on osteoblast cells during their proliferation and differentiation stages. A human fetal osteoblast cell line was cultured and treated with LLLT. The cells were divided into experimental groups according to the power delivered and periods of exposure per day for each laser power. The (3-(4,5-dimethylthiazol-2yl)-2,5 diphenyl tetrazolium bromide) (MTT) assay was used to determine cell proliferation. Both alkaline phosphatase and osteocalcin activity assays were assessed for cell differentiation. All treatment groups showed a significant increase in cell proliferation and differentiation compared to the control group. Regarding the exposure time, the subgroups treated with the LLLT for 6 min showed higher proliferation and differentiation rates for the powers delivered, the 300-mW LLLT group significantly increased the amount of cell proliferation. By contrast, the 100 and 200 mW groups showed significantly greater amounts of cell differentiation. These results suggest that the use of LLLT may play an important role in stimulating osteoblast cells for improved bone formation.
  16. Farea M, Husein A, Halim AS, Berahim Z, Nurul AA, Mokhtar KI, et al.
    Clin Oral Investig, 2016 Jul;20(6):1181-91.
    PMID: 26392396 DOI: 10.1007/s00784-015-1601-6
    The purpose of this study was to evaluate the synergistic effect of epithelial rests of Malassez cells (ERM) and transforming growth factor-β1 (TGF-β1) on proliferation, cementogenic and osteogenic differentiation of stem cells derived from human exfoliated deciduous teeth (SHED).
  17. Shahid F, Nowrin SA, Alam MK, Khamis MF, Husein A, Rahman NA
    Healthcare (Basel), 2023 Mar 15;11(6).
    PMID: 36981521 DOI: 10.3390/healthcare11060864
    This study aimed to assess the outcomes of low-level laser therapy (LLLT) with the conventional bracket (CB) and self-ligating (SL) bracket systems on root resorption (RR) during orthodontic treatment. A total of 32 patients were included in this randomized clinical trial. All the patients were randomly divided into four individual groups (SLL: self-ligating laser, CBL: conventional bracket laser, SLNL: self-ligating non-laser, CBNL: conventional bracket non-laser). RR was measured from the cone-beam computed tomography (CBCT) radiographs which were taken at two stages of the orthodontic treatment: pre-treatment (T1) and after leveling and alignment stage (T2). Wilcoxon rank test for the comparison was conducted to compare the RR at T1 and T2 stages within each group and showed a significant difference (p < 0.05) for various variables. Mann Whitney test compared the RR in laser and non-laser groups irrespective of the bracket systems and exhibited no significant differences except the left lateral incisor. Moreover, CB and SL groups showed no significant difference in RR among any tooth. Kruskal Wallis test was performed to compare the RR among all groups which presented no significant differences. LLLT and bracket systems have no consequences on RR until the leveling and alignment stage of orthodontic treatment.
  18. Al-Rawas M, Abdullah JY, Elmarhoumy B, Johari Y, Ariffin A, Husein A
    J Prosthet Dent, 2024 May 09.
    PMID: 38729790 DOI: 10.1016/j.prosdent.2024.04.022
    STATEMENT OF PROBLEM: The stability of mandibular removable partial dentures with bilateral distal extensions may be improved with the controlled tissue support achieved by using the altered cast impression technique, although this process is time-consuming and technique-sensitive.

    PURPOSE: The purpose of this pilot clinical study was to compare casts generated from a conventional definitive impression with casts generated from an altered cast impression using a 3-dimensional (3D) analysis software program.

    MATERIAL AND METHODS: Three partially edentulous participants with mandibular Kennedy Class I were enrolled, and impressions were made with the 2 techniques and poured in stone. The casts were scanned, aligned, and superimposed by using a 3D analysis software program. Surface deviations were measured to evaluate the differences in displacement induced by the impression on the tissue surface. Five observations were made in 4 different areas on each partially edentulous side. Means from these observations were generated, and the Wilcoxon and Mann Whitney tests were performed for all data to assess the differences between the right and left sides in the same participant and among the 3 participants (α=.05).

    RESULTS: The casts made from the altered cast impression had an overall mean ±standard deviation displacement of -0.05 ±1.25 mm on the right and left sides of the mandibular buccal shelf area. Moreover, the greatest overall difference of about 0.45 ±0.41 mm occurred on the lingual slope of the residual ridge, and the differences in the other areas were 0.10 ±0.99 mm (crest of the residual ridge) and 0.16 ±0.66 mm (buccal slope of the residual ridge). The overall differences varied statistically between significance and nonsignificance for the same participant and among the 3 participants.

    CONCLUSIONS: A digital comparative analysis of the conventional and altered cast methods of recording the bilateral distal extension areas in partially edentulous participants showed that the altered cast method exhibited more displacement on the buccal vestibule or buccal shelf area compared with other examined areas. The differences between the 2 impression methods in the displacement values among the examined areas were minimal and in close proximity, and such differences may lack clinical significance.

Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links