SUMMARY: Background rVIII-SingleChain is a novel B-domain truncated recombinant factor VIII (rFVIII) comprised of covalently bonded FVIII heavy and light chains, demonstrating a high binding affinity to von Willebrand factor. Objectives This phase III study investigated the safety, efficacy and pharmacokinetics of rVIII-SingleChain in previously treated pediatric patients < 12 years of age with severe hemophilia A. Patients/Methods Patients could be assigned to prophylaxis or on-demand therapy by the investigator. For patients assigned to prophylaxis, the treatment regimen and dose were based on the bleeding phenotype. For patients receiving on-demand therapy, dosing was guided by World Federation of Hemophilia recommendations. The primary endpoint was treatment success, defined as a rating of 'excellent' or 'good' on the investigator's clinical assessment of hemostatic efficacy for all treated bleeding events. Results The study enrolled 84 patients (0 to < 6 years, n = 35; ≥ 6 to < 12 years, n = 49); 81 were assigned to prophylaxis and three to an on-demand regimen. Patients accumulated a total of 5239 exposure days (EDs), with 65 participants reaching > 50 EDs. In the 347 bleeds treated and evaluated by the investigator, hemostatic efficacy was rated as excellent or good in 96.3%. The median annualized spontaneous bleeding rate was 0.00 (Q1, Q3: 0.00, 2.20), and the median annualized bleeding rate was 3.69 (Q1, Q3: 0.00, 7.20) across all prophylaxis regimens. No participant developed an inhibitor. Conclusions rVIII-SingleChain is a novel rFVIII molecule showing excellent hemostatic efficacy and a favorable safety profile in a clinical study in children < 12 years of age with severe hemophilia A.
SUMMARY: Background Nonacog beta pegol is a recombinant glycoPEGylated factor IX with an extended half-life, developed to improve care for patients with hemophilia B. Objectives To investigate the safety, efficacy and pharmacokinetics of nonacog beta pegol for the prophylaxis and treatment of bleeds in previously treated children with hemophilia B. Patients/Methods This phase 3 trial, paradigm(™) 5, enrolled and treated 25 children (aged ≤ 12 years) with hemophilia B (FIX ≤ 2%). Patients were stratified by age (0-6 years and 7-12 years), and received once-weekly prophylaxis with 40 IU kg(-1) nonacog beta pegol for 50 exposure days. Results No patient developed inhibitors, and no safety concerns were identified. Forty-two bleeds in 15 patients were reported to have been treated; the overall success rate was 92.9%, and most bleeds (85.7%) resolved after one dose. The median annualized bleeding rates (ABRs; bleeds per patient per year) were 1.0 in the total population, 0.0 in the 0-6-year group, and 2.0 in the 7-12-year group; the estimated mean ABRs were 1.44 in the total population, 0.87 in the 0-6-year group, and 1.88 in the 7-12-year group. For 22 patients who had previously been receiving prophylaxis, the estimated mean ABR was 1.38 versus a historical ABR of 2.51. Estimated mean steady-state FIX trough levels were 0.153 IU mL(-1) (0-6 years) and 0.190 IU mL(-1) (7-12 years). Conclusion Nonacog beta pegol was well tolerated in previously treated children with hemophilia B; a 40 IU kg(-1) dose provided effective once-weekly prophylaxis and hemostasis when bleeds were treated.
METHODS: We prospectively analyzed the use of FloSeal with a hemostatic delivery system in transnasal endoscopic and microscopic skull base procedures performed at the authors' institution from January 1, 2015, to June 30, 2015. In all cases the number of aliquots was noted for the entire operation, and the total number of FloSeal ampules of 5 mL was also recorded.
RESULTS: Our device allowed controlled application of small amounts (0.5-1 mL) of FloSeal to the site of bleeding. This controlled application resulted not only in increased visibility during its application, but it also reduced the amount of FloSeal required during the procedure. We were able to use 5-10 applications per 5-mL ampule of FloSeal within an individual procedure. No procedure required more than one 5-mL ampule of FloSeal. Therefore, the use of our device results in a reduction of costs. Prior to the use of our device, we were often only able to use 1 vial of 5 ml of material for 1 or 2 applications, especially in transnasal endoscopic procedures when working along a deep corridor.
CONCLUSIONS: Our results indicate that our delivery device of FlowSeal can effectively control hemostasis by applying small amounts of FlowSeal to the site of bleeding. This results in increased visibility during hemostasis and a reduction of cost.
AIM: Our present paper has been written to disclose the statistical counts on the number of vWD cases reported from 2011 to 2013.
MATERIAL AND METHODS: This article is based on sociodemographic data, diagnoses and laboratory findings of vWD in Malaysia. A total of 92 patients were reported to have vWD in Malaysia from 2011 to 2013.
RESULTS: Sociodemographic-analysis revealed that 60% were females, 63% were of the Malay ethnicity, 41.3% were in the 19-44 year old age group and 15.2% were from Sabah, with the East region having the highest registered number of vWD cases. In Malaysia, most patients are predominately affected by vWD type 1 (77.2%). Factor 8, von Willebrand factor: Antigen and vWF: Collagen-Binding was the strongest determinants in the laboratory profiles of vWD.
CONCLUSION: This report has been done with great interest to provide an immense contribution from Malaysia, by revealing the statistical counts on vWD from 2011-2013.
CASE REPORT: We present a case report on management of an electrosurgery induced osteonecrosis involving maxillary alveolus of left premolars.
DISCUSSION: Inadvertent contact of the electrosurgery tip on bone can result in necrosis making it necessary to remove the sequestrum and graft the defect. Platelet rich fibrin in combination with bone grafts have been well documented to provide successful periodontal regeneration.
CLINICAL IMPLICATIONS: Our aim of presenting this report is to create awareness among the health care providers regarding electrosurgical injuries. To our knowledge, this is the first time platelet rich fibrin has been used in the management of intraoral electrosurgical injury. Combining bone grafts with platelet rich fibrin is a good alternative as it can be done with relative ease and predictable outcome.