Displaying publications 21 - 40 of 178 in total

Abstract:
Sort:
  1. Andiappan H, Nissapatorn V, Sawangjaroen N, Nyunt MH, Lau YL, Khaing SL, et al.
    Parasit Vectors, 2014;7:564.
    PMID: 25498432 DOI: 10.1186/s13071-014-0564-9
    Toxoplasma gondii, an obligate intracellular protozoan parasite, causes a disease called toxoplasmosis which can sometimes be acquired congenitally by a newborn from an infected mother. This study aimed to determine the seroprevalence of Toxoplasma infection and its associated risks among 219 and 215 pregnant women from Malaysia and Myanmar, respectively.
    Matched MeSH terms: Immunoglobulin M/blood
  2. Tan XT, Amran F, Chee Cheong K, Ahmad N
    BMC Infect Dis, 2014;14:563.
    PMID: 25338815 DOI: 10.1186/s12879-014-0563-7
    Leptospirosis is a zoonotic disease caused by Leptospira species and is distributed globally. Microscopic agglutination test (MAT) is the serological 'gold standard' for diagnosis of leptospirosis but it is time-consuming and labour-intensive. An alternative serological method that is rapid, sensitive and specific is important for early treatment to reduce morbidity and mortality. The use of local Leptospira isolation may improve the sensitivity and specificity of the test because it may varies from one geographical region to another region. The objective of this study was to determine the sensitivity, specificity and cut-off points for an in-house Immunoglobulin M (IgM) enzyme-linked immunosorbent assay (ELISA) using a locally isolated Leptospiral strain IMR/175 as the antigen for the detection of anti-Leptospiral IgM.
    Matched MeSH terms: Immunoglobulin M/blood
  3. Hunsperger EA, Yoksan S, Buchy P, Nguyen VC, Sekaran SD, Enria DA, et al.
    PLoS Negl Trop Dis, 2014 Oct;8(10):e3171.
    PMID: 25330157 DOI: 10.1371/journal.pntd.0003171
    Commercially available diagnostic test kits for detection of dengue virus (DENV) non-structural protein 1 (NS1) and anti-DENV IgM were evaluated for their sensitivity and specificity and other performance characteristics by a diagnostic laboratory network developed by World Health Organization (WHO), the UNICEF/UNDP/World Bank/WHO Special Programme for Research and Training in Tropical Diseases (TDR) and the Pediatric Dengue Vaccine Initiative (PDVI). Each network laboratory contributed characterized serum specimens for the panels used in the evaluation. Microplate enzyme-linked immunosorbent assay (ELISA) and rapid diagnostic test (RDT formats) were represented by the kits. Each ELISA was evaluated by 2 laboratories and RDTs were evaluated by at least 3 laboratories. The reference tests for IgM anti-DENV were laboratory developed assays produced by the Armed Forces Research Institute for Medical Science (AFRIMS) and the Centers for Disease Control and Prevention (CDC), and the NS1 reference test was reverse transcriptase polymerase chain reaction (RT-PCR). Results were analyzed to determine sensitivity, specificity, inter-laboratory and inter-reader agreement, lot-to-lot variation and ease-of-use. NS1 ELISA sensitivity was 60-75% and specificity 71-80%; NS1 RDT sensitivity was 38-71% and specificity 76-80%; the IgM anti-DENV RDTs sensitivity was 30-96%, with a specificity of 86-92%, and IgM anti-DENV ELISA sensitivity was 96-98% and specificity 78-91%. NS1 tests were generally more sensitive in specimens from the acute phase of dengue and in primary DENV infection, whereas IgM anti-DENV tests were less sensitive in secondary DENV infections. The reproducibility of the NS1 RDTs ranged from 92-99% and the IgM anti-DENV RDTs from 88-94%.
    Matched MeSH terms: Immunoglobulin M/blood*
  4. Wong WR, Krupin O, Sekaran SD, Mahamd Adikan FR, Berini P
    Anal Chem, 2014 Feb 4;86(3):1735-43.
    PMID: 24410440 DOI: 10.1021/ac403539k
    We present a compact, cost-effective, label-free, real-time biosensor based on long-range surface plasmon polariton (LRSPP) gold (Au) waveguides for the detection of dengue-specific immunoglobulin M (IgM) antibody, and we demonstrate detection in actual patient blood plasma samples. Two surface functionalization approaches are proposed and demonstrated: a dengue virus serotype 2 (DENV-2) functionalized surface to capture dengue-specific IgM antibody in blood plasma and the reverse, a blood plasma functionalized surface to capture DENV-2. The results obtained via these two surface functionalization approaches are comparable to, or of greater quality, than those collected by conventional IgM antibody capture enzyme linked immunosorbent assay (MAC-ELISA). Our second functionalization approach was found to minimize nonspecific binding, thus improving the sensitivity and accuracy of the test. We also demonstrate reuse of the biosensors by regenerating the sensing surface down to the virus (or antibody) level or down to the bare Au.
    Matched MeSH terms: Immunoglobulin M/blood
  5. Wang SM, Sekaran SD
    Am J Trop Med Hyg, 2010 Sep;83(3):690-5.
    PMID: 20810840 DOI: 10.4269/ajtmh.2010.10-0117
    A commercial Dengue Duo rapid test kit was evaluated for early dengue diagnosis by detection of dengue virus NS1 antigen and immunoglobulin M (IgM)/IgG antibodies. A total of 420 patient serum samples were subjected to real-time reverse transcription-polymerase chain reaction (RT-PCR), in-house IgM capture enzyme-linked immunosorbent assay (ELISA), hemagglutination inhibition assay, and the SD Dengue Duo rapid test. Of the 320 dengue acute and convalescent sera, dengue infection was detected by either serology or RT-PCR in 300 samples (93.75%), as compared with 289 samples (90.31%) in the combined SD Duo NS1/IgM. The NS1 detection rate is inversely proportional, whereas the IgM detection rate is directly proportional to the presence of IgG antibodies. The sensitivity and specificity in diagnosing acute dengue infection in the SD Duo NS1/IgM were 88.65% and 98.75%, respectively. The assay is sensitive and highly specific. Detection of both NS1 and IgM by SD Duo gave comparable detection rate by either serology or RT-PCR.
    Matched MeSH terms: Immunoglobulin M/analysis
  6. Bakar AF, Alitheen NB, Keong YS, Hamid M, Ali SA, Ali AM
    Hybridoma (Larchmt), 2009 Jun;28(3):199-203.
    PMID: 19519247 DOI: 10.1089/hyb.2007.0531
    Hybridoma clone C3A8, which is a fusion product between splenic lymphocytes of Balb/c mice immunized with MCF7 breast carcinoma cells and SP2/0 myelomas, was produced and characterized. A stable clone that secreted IgM monoclonal antibody (MAb) with kappa light chain was obtained through limiting dilutions. Cell-ELISA screening, flow cytometry analysis, and immunofluorescence staining revealed that the MAb C3A8 had bound specifically and strongly to MCF7 and HT29 but cross reacted weakly or not on HeLa cell line. The MAb C3A8 reacted positively with paraffin-embedded tissues of human breast and colon cancers but there were no positive reactions on normal tissues. Western blot analysis showed the MAb recognized a 55 kDa protein, which was present in the extract of MCF7 and HT29 cell lines. Our results demonstrated that MAb C3A8 could be used for basic and clinical research of breast and colon cancers.
    Matched MeSH terms: Immunoglobulin M/immunology*
  7. Tan PC, Rajasingam G, Devi S, Omar SZ
    Obstet Gynecol, 2008 May;111(5):1111-7.
    PMID: 18448743 DOI: 10.1097/AOG.0b013e31816a49fc
    To estimate prevalence rate of recent dengue infection in parturients, as well as the vertical transmission rate, and to compare pregnancy outcomes among infected women.
    Matched MeSH terms: Immunoglobulin M/analysis
  8. Kumarasamy V, Zuridah H, Hani AW, Mariam M, Chua KB
    Med J Malaysia, 2007 Mar;62(1):85-6.
    PMID: 17682584 MyJurnal
    The performance of a commercial rapid immunochromatographic dengue IgG/IgM assay device was evaluated against an in-place dengue IgM-capture ELISA in the National Public Health laboratory. Of the 239 serum samples from patients with clinical diagnosis of acute dengue illness, 140 and 99 samples were tested positive and negative respectively for anti-dengue IgM by the in-placed ELISA. Comparatively, 72 and 76 samples were tested positive and negative respectively, and 91 samples gave equivocal results by the rapid dengue test device. The rapid immunochromatographic assay device gave a relative sensitivity of 49.3% and a relative specificity of 62.6%. Though the rapid immunochromatographic assay device has the advantages of rapid testing which simultaneously detects both IgG and IgM and can also be performed with whole blood, serum or plasma, the user has to exercise extreme caution with the interpretation of the test result.
    Matched MeSH terms: Immunoglobulin M/blood*
  9. Kari K, Liu W, Gautama K, Mammen MP, Clemens JD, Nisalak A, et al.
    BMC Med, 2006;4:8.
    PMID: 16603053
    Japanese encephalitis (JE) is presumed to be endemic throughout Asia, yet only a few cases have been reported in tropical Asian countries such as Indonesia, Malaysia and the Philippines. To estimate the true disease burden due to JE in this region, we conducted a prospective, hospital-based surveillance with a catchment population of 599,120 children less than 12 years of age in Bali, Indonesia, from July 2001 through December 2003.
    Matched MeSH terms: Immunoglobulin M/blood
  10. Hafner C, Koellner K, Vogt T, Landthaler M, Szeimies RM
    Hautarzt, 2006 Aug;57(8):705-7.
    PMID: 16283129
    A 39-year-old patient developed a disseminated rash with scattered petechiae, fever, malaise and arthralgia after a trip to Malaysia. The patient displayed increasing dengue IgG titers and borderline dengue IgM titers. Dengue fever with a hemorrhagic course is a rare condition in adult patients. Patients who have previously had dengue fever and retained non-neutralizing heterotypic antibodies are more likely to develop this complication via the phenomenon of antibody-dependent enhancement.
    Matched MeSH terms: Immunoglobulin M/blood
  11. Jahanshahi P, Sekaran SD, Adikan FR
    Med Biol Eng Comput, 2015 Aug;53(8):679-87.
    PMID: 25791696 DOI: 10.1007/s11517-015-1262-2
    Evaluation of binding between analytes and its relevant ligands on surface plasmon resonance (SPR) biosensor is of considerable importance for accurate determination and screening of an interference in immunosensors. Dengue virus serotype 2 was used as a case study in this investigation. This research work compares and interprets the results obtained from analytical analysis with the experimental ones. Both the theoretical calculations and experimental results are verified with one sample from each category of dengue serotypes 2 (low, mid, and high positive), which have been examined in the database of established laboratorial diagnosis. In order to perform this investigation, the SPR angle variations are calculated, analyzed, and then validated via experimental SPR angle variations. Accordingly, the error ratios of 5.35, 6.54, and 3.72% were obtained for the low-, mid-, and high-positive-specific immune globulins of patient serums, respectively. In addition, the magnetic fields of the biosensor are numerically simulated to show the effect of different binding mediums.
    Matched MeSH terms: Immunoglobulin M/blood*
  12. Sachithanandan S, Fielding JF
    Med J Malaysia, 1999 Mar;54(1):110-3.
    PMID: 10972013
    The aim of this study was to determine if knowledge of both the serum HCV RNA and serum anti core IgM antibody status enabled one to predict the histological severity in chronic hepatitis C. We studied 45 female patients with chronic hepatitis C infection. The presence or absence of IgM antibodies to HCV and HCV RNA by PCR in each patient's serum was determined. Liver biopsies performed were scored according to a modified Desmet's histological activity index. Negative HCV RNA patients had least histological change. HCV RNA positive patients who were also IgM antibody positive had lower scores than their IgM negative counterparts. The grade of histological severity is more accurately predictable from knowledge of both the HCV RNA and IgM anti HCV status of the patient.
    Matched MeSH terms: Immunoglobulin M/analysis*
  13. Lam SK, Devine PL
    Clin Diagn Virol, 1998 May 1;10(1):75-81.
    PMID: 9646004
    Rapid diagnosis of dengue infection is essential to patient management and disease control. The development of a rapid (5 min) immunochromatographic test and a 2 h commercial capture enzyme linked immunosorbent assay (ELISA) for anti-dengue IgM and IgG antibodies may lead to more rapid and accurate testing in peripheral health settings and diagnostic laboratories.
    Matched MeSH terms: Immunoglobulin M/blood*
  14. Rahmah N, Anuar AK
    Biochem Biophys Res Commun, 1992 Aug 31;187(1):294-8.
    PMID: 1520310
    C57BL/6 mice were orally infected with different doses of cysts of ME49 strain of Toxoplasma gondii to produce groups of acutely and chronically infected mice. Sera were obtained at different periods post-infection. SDS-PAGE was ran with excretory/secretory antigens of ME49 and RH strains of T. gondii, followed by Western blot analyses using the above sera and anti- IgA, IgM, IgG as conjugates. The SDS-PAGE profiles of the two antigens were similar. However the antigenic bands showed variations in all blots, most evidently in IgA blots of chronic sera. IgG blots showed greatest similarities in reactive bands. In IgM blots, more common bands were shown in chronic sera than in acute sera. Variations and similarities in prominence of some bands and time of their appearance were also noted, especially in IgM and IgG blots of chronic sera. Thus antigenic variations and similarities are present in excretory/secretory products of different strains of T. gondii.
    Matched MeSH terms: Immunoglobulin M/blood
  15. Lam SK, Fong MY, Chungue E, Doraisingham S, Igarashi A, Khin MA, et al.
    Clin Diagn Virol, 1996 Nov;7(2):93-8.
    PMID: 9137865 DOI: 10.1016/S0928-0197(96)00257-7
    The traditional methods used in the diagnosis of dengue infection do not lend themselves to field application. As such, clinical specimens have to be sent to a central laboratory for processing which invariably leads to delay. This affects patient management and disease control. The development of the dengue IgM dot enzyme immunoassay has opened up the possibility of carrying out the test in peripheral health settings.
    Matched MeSH terms: Immunoglobulin M/blood
  16. Koay AS, Tay ST, Cheong YM, Yasin RM
    PMID: 8629074
    An IgM dot-immunobinding assay (IgM-DIA) was developed for the diagnosis of scrub typhus infection. The whole cell antigens of Karp, Kato and Gilliam strains of Rickettsia tsutsugamushi were immobilized onto nitrocellulose paper and reacted with patients sera. The presence of IgM R. tsutsugamushi specific antibody in the patient sera could be detected by the observation of a visible brown dot on the nitrocellulose paper. The IgM-DIA has a sensitivity of 90.4% and specificity of 81.4% as compared to the indirect immunoperoxidase test. The IgM-DIA is rapid, simple, cost-effective, does not require microscope or incubator. It is recommended as a rapid screening test for the diagnosis of scrub typhus infection in the field or rural area within the hyperendemic region.
    Matched MeSH terms: Immunoglobulin M/analysis*
  17. Noh LM, Low SM, Lajin I, Abdullah N
    Malays J Pathol, 1992 Dec;14(2):121-3.
    PMID: 1304625
    A 20-month-old Indian boy presented with recurrent pyogenic infections and failure to thrive. His IgG and IgA levels were low, but his IgM was elevated. He also had undetectable isohaemagglutinin titre and neutropenia, both parameters being poor prognostic indicators in this very rare primary immunodeficiency state--antibody deficiency with hyper IgM. Our patient subsequently succumbed to Pseudomonas aeruginosa septicaemia and meningitis inspite of aggressive antibiotic and intravenous gammaglobulin therapy. To the best of our knowledge, this is the first such case to be documented in Malaysia.
    Matched MeSH terms: Immunoglobulin M*
  18. Cardosa MJ, Tio PH, Nimmannitya S, Nisalak A, Innis B
    PMID: 1298081
    The highly sensitive AFRIMS format IgM capture ELISA for the diagnosis of dengue virus infections requires the use of mouse brain derived hemagglutinins and consequently also the use of 20% acetone extracted normal human serum to eliminate high background. These reagents are not always easily available and we have thus compared the AFRIMS format with another published format which uses cell culture derived antigens (culture fluid, CF, format) in order to determine if it is reasonable to use cell culture derived antigens in situations where hemagglutinins and normal human serum are difficult to obtain. The study shows that using AFRIMS results as the reference point, the CF format described here has a sensitivity of 90% and a specificity of 96%.
    Matched MeSH terms: Immunoglobulin M/blood*
  19. Lim SB, Chua CT, Hashim OH
    J Immunol Methods, 1997 Dec 01;209(2):177-86.
    PMID: 9461333
    A mannose-binding lectin, termed champedak lectin-M, was isolated from an extract of the crude seeds of champedak (Artocarpus integer). On gel filtration chromatography, the lectin eluted in a single peak at elution volumes corresponding to 64 kDa. SDS-PAGE showed the mannose-binding lectin to be composed of 16.8 kDa polypeptides with some of the polypeptides being disulphide-linked to give dimers. When tested with all isotypes of immunoglobulins, champedak lectin-M demonstrated a selective strong interaction with human IgE and IgM, and a weak interaction with IgA2. The binding interactions of lectin-M were metal ion independent. The lectin was also shown to interact with horseradish peroxidase, ovalbumin, porcine thyroglobulin, human alpha1-acid glycoprotein, transferrin and alpha1-antitrypsin. It demonstrated a binding preference to Man alpha 1-3Man ligands in comparison to Man alpha 1-6Man or Man alpha 1-2Man.
    Matched MeSH terms: Immunoglobulin M/metabolism*
  20. Thomas V, Sinniah B, Yap PL
    PMID: 6996108
    A total of 736 sera collected from cord blood babies, children and adults of both sexes and of different age groups in Malaysia were tested using indirect fluorescent antibody technique for Toxoplasma antibodies. The RH strain of Toxoplasma gondii zoites were used as antigen. One hundred and twenty five sera which were reactive at 1:64 or high titres were tested with IgM specific conjugate. Results of the present studies showed that the prevalence of Toxoplasma antibody was highest among the Malays and lowest among children than among adults. The significance of Toxoplasma specific IgM was discussed.
    Matched MeSH terms: Immunoglobulin M/analysis*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links