Displaying publications 21 - 39 of 39 in total

Abstract:
Sort:
  1. Patil PG, Seow LL, Uddanwadikar R, Pau A, Ukey PD
    J Prosthet Dent, 2024 Feb;131(2):281.e1-281.e9.
    PMID: 37985307 DOI: 10.1016/j.prosdent.2023.10.023
    STATEMENT OF PROBLEM: The 2-implant mandibular overdenture (2IMO) is a popular treatment for patients with mandibular edentulism. However, information on the influence of implant positions on crestal strain is lacking.

    PURPOSE: The purpose of this in vitro study was to evaluate the crestal strain around 2 implants to support mandibular overdentures when placed at different positions.

    MATERIAL AND METHODS: Edentulous mandibles were 3-dimensionally (3D) designed separately with 2 holes for implant placement at similar distances of 5, 10, 15, and 20 mm from the midline, resulting in 4 study conditions. The complete denture models were 3D designed and printed from digital imaging and communications in medicine (DICOM) images after scanning the patient's denture. Two 4.3×12-mm dummy implants were placed in the preplanned holes. Two linear strain gauges were attached on the crest of the mesial and distal side of each implant (CH1, CH2, CH3, and CH4) and connected to a computer to record the electrical signals. Male LOCATOR attachments were attached, the mucosal layer simulated, and the denture picked up with pink female nylon caps. A unilateral and bilateral force of 100 N was maintained for 10 seconds for each model in a universal testing machine while recording the maximum strains in the DCS-100A KYOWA computer software program. Data were analyzed by using 1-way analysis of variance, the Tukey post hoc test, and the paired t test (α=.05).

    RESULTS: Under bilateral loading, the strain values indicated a trend with increasing distance between the implants with both right and left distal strain gauges (CH4 and CH1). The negative (-ve) values indicated the compressive force, and the positive (+ve) values indicated the tensile force being applied on the strain gauges. The strain values for CH4 ranged between -166.08 for the 5-mm and -251.58 for the 20-mm position; and for CH1 between -168.08 for the 5-mm and -297.83 for the 20-mm position. The remaining 2 mesial strain gauges for all 4 implant positions remained lower than for CH4 and CH1. Under unilateral-right loading, only the right-side distal strain gauge CH4 indicated the increasing trend in the strain values with -147.5 for the 5-mm, -157.17 for the 10-mm, -209.33 for the 15-mm, and -234.75 for the 20 mm position. The remaining 3 strain gauges CH3, CH2, and CH1 ranged between -28.33 and -107.17. For each position for both implants, significantly higher (P

    Matched MeSH terms: Mandible/surgery
  2. Mustafa A, Lung CY, Mustafa NS, Mustafa BA, Kashmoola MA, Zwahlen RA, et al.
    Clin Oral Implants Res, 2016 Mar;27(3):303-9.
    PMID: 25393376 DOI: 10.1111/clr.12525
    OBJECTIVES: To investigate the effect of eicosapentaenoic acid (EPA)-coated Ti implants on osteoconduction in white New Zealand rabbit mandibles.

    MATERIAL AND METHODS: Sandblasted and cleansed planar titanium specimens with a size of 5 × 5 × 1 mm were coated on one side with 0.25 vol% eicosapentaenoic acid (EPA). The other side of the specimens was kept highly polished (the control side). These specimens were inserted in rabbit mandibles. Twelve rabbits were randomly assigned into three study groups (n = 4). The rabbits were sacrificed at 4, 8, and 12 weeks. The harvested specimens with the implants were assessed for new bone formation on both sides of the implant using CBCT, conventional radiographs, and the biaxial pullout test. The results were statistically analyzed by a nonparametric Kruskal-Wallis test and Friedman's test as multiple comparisons and by Brunner-Langer nonparametric mixed model approach (R Software).

    RESULTS: A significant osteoconductive bone formation was found on the EPA-coated Ti implant surface (P < 0.05) at 8 weeks when compared to the polished surface (control). Biaxial pullout test results showed a significant difference (P < 0.05) after 8 and 12 weeks with a maximum force of 243.8 N, compared to 143.25 N after 4 week.

    CONCLUSION: EPA implant coating promoted osteoconduction on the Ti implant surfaces, enhancing the anchorage of the implant to the surrounding bone in white New Zealand rabbits.

    Matched MeSH terms: Mandible/surgery
  3. Purmal K, Alam MK, Pohchi A, Abdul Razak NH
    PLoS One, 2013;8(12):e84202.
    PMID: 24367643 DOI: 10.1371/journal.pone.0084202
    Intermaxillary (IMF) screws feature several advantages over other devices used for intermaxillary fixation, but using cone beam computed tomography (CBCT) scans to determine the safe and danger zones to place these devices for all patients can be expensive. This study aimed to determine the optimal interradicular and buccopalatal/buccolingual spaces for IMF screw placement in the maxilla and mandible. The CBCT volumetric data of 193 patients was used to generate transaxial slices between the second molar on the right to the second molar on the left in both arches. The mean interradicular and buccopalatal/buccolingual distances and standard deviation values were obtained at heights of 2, 5, 8 and 11 mm from the alveolar bone crest. An IMF screw with a diameter of 1.0 mm and length of 7 mm can be placed distal to the canines (2 - 11 mm from the alveolar crest) and less than 8 mm between the molars in the maxilla. In the mandible, the safest position is distal to the first premolar (more than 5 mm) and distal to the second premolar (more than 2 mm). There was a significant difference (p<0.05) between the right and left quadrants. The colour coding 3D template showed the safe and danger zones based on the mesiodistal, buccopalatal and buccolingual distances in the maxilla and mandible.The safest sites for IMF screw insertion in the maxilla were between the canines and first premolars and between the first and second molars. In the mandible, the safest sites were between the first and second premolars and between the second premolar and first molar. However, the IMF screw should not exceed 1.0 mm in diameter and 7 mm in length.
    Matched MeSH terms: Mandible/surgery
  4. Siar CH, Toh CG, Ali TB, Seiz D, Ong ST
    Clin Oral Implants Res, 2012 Apr;23(4):438-46.
    PMID: 21435011 DOI: 10.1111/j.1600-0501.2010.02145.x
    A stable oral mucosa is crucial for long-term survival and biofunctionality of implants. Most of this evidence is derived from clinical and animal studies based solely on implant-supported prosthesis. Much less is known about the dimensions and relationships of this soft tissue complex investing tooth-implant-supported bridgework (TISB). The aim here was to obtain experimental evidence on the dimensional characteristics of oral mucosa around TISB with two different abutment designs.
    Matched MeSH terms: Mandible/surgery*
  5. Suhaili DN, Somasundaram S, Lau SH, Ajura AJ, Roslan AR, Ramli R
    Int J Pediatr Otorhinolaryngol, 2011 Jan;75(1):131-3.
    PMID: 21067822 DOI: 10.1016/j.ijporl.2010.10.004
    Diprosopus or duplication of the lower lip and mandible is a very rare congenital anomaly. We report this unusual case occurring in a girl who presented to our hospital at the age of 4 months. Surgery and problems related to this anomaly are discussed.
    Matched MeSH terms: Mandible/surgery
  6. Younis L, Taher A, Abu-Hassan MI, Tin O
    J Contemp Dent Pract, 2009;10(4):35-42.
    PMID: 19575052
    The purpose of this study was to compare bone healing and coronal bone remodeling following both immediate and delayed placement of titanium dental implants in extraction sockets.
    Matched MeSH terms: Mandible/surgery
  7. Khalid T, Yunus N, Ibrahim N, Elkezza A, Masood M
    Clin Oral Implants Res, 2017 May;28(5):535-542.
    PMID: 26989853 DOI: 10.1111/clr.12831
    OBJECTIVE: To determine oral health-related quality of life (OHRQoL) and denture satisfaction (DS) in patients provided with mandibular implant-supported overdentures (ISOD) retained by two different attachment types, and the association of mandibular bone volume with the change in patient-reported outcome, before and after implant treatment.

    MATERIAL AND METHODS: Thirty-four patients (mean age 60.70  ±  8.7 years) received telescopic crown or locator attachments for ISOD and completed OHIP-14 (Malaysian version) and DS questionnaires, at baseline (T0 ) with new conventional complete dentures (CCD) and 3 months (T1 ) and 3 years (T2 ) after ISOD conversion. Mandibular bone volume was calculated from cone beam computed tomography (CBCT) datasets using Mimics software. Mean changes (MC) in OHIP-14 and DS at intervals were analyzed using the Wilcoxon signed-rank test and effect size (ES). The association of bone volume, implant attachment type, and other patient variables with the change in OHIP-14 and DS were determined using multivariate linear regression analysis.

    RESULTS: The MC in OHIP-14 and DS scores from T0 to T1 and T2 showed significant improvement with moderate and large ES, respectively. Regression analyses for the change in OHIP-14 score from T0 to T2 showed significant association with implant attachment type (P = 0.043), bone volume (P = 0.004), and baseline OHIP-14 (P = 0.001), while for DS, the association was only significant with baseline DS score (P = 0.001).

    CONCLUSION: Improvement in patients' OHRQoL and satisfaction with ISOD was associated with their baseline ratings. Mandibular bone volume had a stronger association for improvement in OHRQoL compared to type of attachment.

    Matched MeSH terms: Mandible/surgery
  8. Breik O, Umapathysivam K, Tivey D, Anderson P
    Int J Pediatr Otorhinolaryngol, 2016 Jun;85:128-35.
    PMID: 27240511 DOI: 10.1016/j.ijporl.2016.03.033
    Mandibular distraction osteogenesis (MDO) is becoming increasingly more commonly used as in neonates and infants with upper airway obstruction secondary to micrognathia. A significant number of these children are dependent on nasoenteric feeding or gastrostomies after birth for adequate nutrition and often suffer from gastro-esophageal reflux (GERD).

    OBJECTIVE: This analysis is a subset of a larger systematic review. The objective of this study is to determine the effects of MDO on feeding and GERD.

    DATA SOURCES: The databases searched included PubMed, Embase, Scopus, Web of Knowledge and grey literature sources.

    STUDY SELECTION: The inclusion criterion included studies in children with clinical evidence of micrognathia/Pierre Robin Sequence (PRS) who have failed conservative treatments, including both syndromic (sMicro) and non-syndromic (iPRS) patients. 21 studies relevant to feeding and 4 studies relevant to GERD outcomes were included. All studies included were case series and case reports.

    RESULTS: MDO leads to a significant improvement in feeding, with 82% of children feeding exclusively orally after surgery. The overall percentage of children with iPRS who were feeding orally was 93.7% compared with only 72.9% in the sMicro group (p<0.004). A growth decline within the first six weeks after surgery was observed in multiple studies. Overall, out of 70 patients with pre-operative GERD, only four had evidence of GERD after surgery.

    CONCLUSIONS: Considering the limitations of this systematic review, this study found that successful relief of airway obstruction by MDO leads to improvement of feeding and improvement in symptoms of GERD in children with upper airway obstruction secondary to micrognathia. Clinicians need to be aware of the risk of growth decline in the initial post-operative period.

    Matched MeSH terms: Mandible/surgery*
  9. Al-Hashedi AA, Taiyeb-Ali TB, Yunus N
    Aust Dent J, 2016 06;61(2):208-18.
    PMID: 25966305 DOI: 10.1111/adj.12337
    BACKGROUND: Short dental implants can be an alternative to bone augmentation procedures at sites of reduced alveolar bone. Most studies on short implants are retrospective or multicentre reports that lack controlled and consistent comparison between different systems. This study aimed to compare clinical and radiographic outcomes of short implants in two different systems in the posterior mandible.

    METHODS: Twenty patients with two adjacent missing posterior teeth were recruited. Patients were assigned equally and randomly into two groups; Bicon(®) (6 or 8 mm) and Ankylos(®) (8 mm) implants. A two-stage surgical approach and single crowns were used for implant placement and loading. Outcomes included peri-implant clinical parameters, implant stability (Periotest values; PTVs) and peri-implant bone changes, which were assessed at baseline, 2, 6 and 12 months post-loading.

    RESULTS: No implant loss was encountered up to 12 months post-loading. No significant difference in the clinical or radiographic parameters was observed except for PTVs (p < 0.05) that was lower in Ankylos(®) implants.

    CONCLUSIONS: The use of short dental implants was associated with excellent 12 months clinical and radiographic outcomes. Ankylos(®) and Bicon(®) implants demonstrated similar peri-implant soft tissue and alveolar bone changes. However, Ankylos(®) implants demonstrated better implant stability at all evaluation intervals.

    Matched MeSH terms: Mandible/surgery*
  10. Siar CH, Toh CG, Romanos G, Swaminathan D, Ong AH, Yaacob H, et al.
    J. Periodontol., 2003 May;74(5):571-8.
    PMID: 12816287
    Today, one critical goal in implant placement is the achievement of optimal soft tissue integration. Reports thus far have demonstrated successful soft tissue preservation in delayed loaded implants placed in anterior jaws. The aim of this study was to histomorphometrically examine the soft tissues around immediately loaded implants placed in the macaque posterior mandible.
    Matched MeSH terms: Mandible/surgery*
  11. Eachempati P, Aggarwal H, Shenoy VK, Baliga M
    J Coll Physicians Surg Pak, 2018 Sep;28(9):S187-S189.
    PMID: 30173693 DOI: 10.29271/jcpsp.2018.09.S187
    Oral mucosal melanoma is rare and more aggressive than cutaneous melanoma. Hard palate and maxillary alveolar crest are most commonly involved. Multidisciplinary team approach is necessary for successful management of this tumor. The main treatment modality is surgical resection, which usually results in impaired mastication, deglutition, speech, oral competence and significant cosmetic deformity. Here, a rare case of oral mucosal melanoma of mandibular gingiva in a 44-year man is reported, who was treated by en-block mandibular resection followed by adjuvant therapy with high dose interferons (IFN) - 2b. Following two weeks of healing period, prosthetic rehabilitation of the patient was done with an interim removable denture prosthesis, which effectively limited the unfavourable effects of surgery and helped him in resocialisation.
    Matched MeSH terms: Mandible/surgery
  12. Al-Juboori MJ, AbdulRahaman SB, Hassan A
    Implant Dent, 2013 Aug;22(4):351-5.
    PMID: 23811720 DOI: 10.1097/ID.0b013e318296583d
    To detect the correlation between crestal bone resorption and implant stability during healing period using resonance frequency analysis (RFA).
    Matched MeSH terms: Mandible/surgery
  13. Baig MR, Rajan G, Yunus N
    Gerodontology, 2012 Jun;29(2):e1140-5.
    PMID: 21615782 DOI: 10.1111/j.1741-2358.2010.00433.x
    Dental rehabilitation of a completely edentulous geriatric patient has always been a challenge to the clinician, especially in treating those with higher expectations and demands. Treatment duration and the amount of residual alveolar bone available are often important considerations when planning for dental implant-based fixed treatment for these patients. With the introduction of zygomatic implants, a graftless alternative solution has emerged for deficient maxillary bone with provision for immediate loading. This article describes the treatment of a completely edentulous elderly patient using zygomatic implants in conjunction with conventional implants. The implants were immediately loaded using a definitive acrylic resin fixed denture reinforced with a cast metal framework, to provide function and aesthetics.
    Matched MeSH terms: Mandible/surgery
  14. Hazarika P, Dipak RN, Parul P, Kailesh P
    Med J Malaysia, 2004 Aug;59(3):323-9.
    PMID: 15727377
    A few series of parapharyngeal space tumours have been reported earlier but recently not many series have been published in English literature. It is rare for any medical center, let alone an individual surgeon, to develop sufficient experience in evaluating these tumours. We present our experience in the treatment of 41 cases of parapharyngeal tumours from January 1992 to December 2001. FNAC, ultrasound and CT scan of the presenting mass was done in most of the patients as the main pre-operative work-up. The strategic location and extension of the tumour may occasionally alter the surgical approach for tumour excision.
    Matched MeSH terms: Mandible/surgery
  15. Yunus N, Abdullah H, Hanapiah F
    J Prosthet Dent, 2001 Jun;85(6):540-3.
    PMID: 11404753
    This article describes the occlusal rehabilitation of a partially edentulous patient who did not want a removable partial denture. Implants and extensive fixed restorations were used to restore posterior support and treat severely worn dentition, respectively. The treatment offered the patient a functional and esthetic result.
    Matched MeSH terms: Mandible/surgery
  16. Ong ST, Siar CH
    Aust Dent J, 1997 Dec;42(6):404-8.
    PMID: 9470284
    Florid cemento-osseous dysplasia refers to a group of fibro-osseous lesions which are exuberant, multiquadrant and arise from the tooth-bearing area of the jaws. It is classically described as a condition occurring almost exclusively in middle-aged black women. A case of florid cemento-osseous dysplasia occurring in a young Chinese male is reported which was rare in regard to race and sex. This 20 year old Chinese man presented with huge symmetrical bony lesions in all four quadrants of the jaws. Clinical presentation, radiological findings and histological features of the excised specimens are described. Treatment of the lesions was unusual. Curettage was first done with minimal benefit and it was followed by mandibular recontouring to improve facial appearance. The outcome of these procedures will be discussed.
    Matched MeSH terms: Mandible/surgery
  17. Voon YS, Patil PG
    J Prosthet Dent, 2018 Apr;119(4):568-573.
    PMID: 28838820 DOI: 10.1016/j.prosdent.2017.05.011
    STATEMENT OF PROBLEM: The genial tubercle is a clinically palpable landmark in the mandible and can be identified in cone beam computed tomography (CBCT). Its location can be used to measure the safe zone in the interforaminal region of the mandible. These measurements may be helpful for implant treatment planning in patients with complete edentulism.

    PURPOSE: The purpose of this clinical study was to evaluate the safe distance in the interforaminal region of the mandible measured from the genial tubercle level for implant osteotomy in a Chinese-Malaysian population.

    MATERIAL AND METHODS: A total of 201 Digital Imaging and Communications in Medicine (DICOM) files were selected for the study from the CBCTs of dentate or edentulous Chinese-Malaysian adult patients with ongoing or completed treatments. Measurements were made with implant planning software. The anatomy of the whole mandible was assessed in the coronal cross-sectional, horizontal view and in panoramic view. Measurements were obtained in millimeters on one side by locating and marking a genial tubercle and then marking the mesial margin of the mental foramen and the anterior loop of the inferior alveolar nerve. The corresponding points of these landmarks were identified on the crest of the mandibular ridge to measure the linear distances. All the measurement steps were repeated on the other side. The linear distance of 2 mm was deducted from the total distance between the genial tubercle and the anterior loop separately for left and right side measurements to identify the safe zone. The mixed 2-way analysis of variance (ANOVA) test was used to analyze side and sex-related variations.

    RESULTS: The mean safe zone measured at the crestal level from the genial tubercle site on the left side of the mandible was 21.12 mm and 21.67 mm on the right side. A statistically significant (P

    Matched MeSH terms: Mandible/surgery*
  18. Kumar Potu B, Jagadeesan S, Bhat KM, Rao Sirasanagandla S
    Morphologie, 2013 Jun;97(317):31-7.
    PMID: 23806306 DOI: 10.1016/j.morpho.2013.04.004
    The retromolar foramen (RMF) and retromolar canal (RMC) are the anatomical structures of the mandible located in retromolar fossa behind the third molar tooth. This foramen and canal contain neurovascular structures which provide accessory/additional innervation to the mandibular molars and the buccal area. These neurovascular contents of the canal gain more importance in medical and dental practice, because these elements are vulnerable to damage during placement of osteointegrated implants, endodontic treatment and sagittal split osteotomy surgeries and a detailed knowledge of this anatomical variation would be vital in understanding failed inferior alveolar nerve blockage, spread of infection and also metastasis. Although few studies have been conducted in the past showing the incidence and types in different population groups, a lacunae in comprehensive review of this structure is lacking. Though this variation posed challenging situations for the practicing surgeons, it has been quite neglected and the incidence of it is not well presented in all the textbooks. Hence, we made an attempt to provide a consolidated review regarding variations and clinical applications of the RMF and RMC.
    Matched MeSH terms: Mandible/surgery
  19. Alkaisi A, Ismail AR, Mutum SS, Ahmad ZA, Masudi S, Abd Razak NH
    J Oral Maxillofac Surg, 2013 Oct;71(10):1758.e1-13.
    PMID: 24040948 DOI: 10.1016/j.joms.2013.05.016
    The main aim of the present study was to evaluate the capacity of stem cells from human exfoliated deciduous teeth (SHED) to enhance mandibular distraction osteogenesis (DO) in rabbits.
    Matched MeSH terms: Mandible/surgery*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links