Displaying publications 21 - 40 of 69 in total

Abstract:
Sort:
  1. Subramaniam R, Mani MP, Jaganathan SK
    Cardiovasc Eng Technol, 2018 09;9(3):503-513.
    PMID: 29700782 DOI: 10.1007/s13239-018-0357-y
    In this study, a small vascular graft based on polyurethane (PU) blended with chitosan (Ch) nanoparticles was fabricated using electrospinning technique. Initially, the chitosan nanoparticles were synthesized using ionic gelation method. UV-Vis spectrophotometer confirmed the presence of synthesized Ch nanoparticles by exhibiting absorption peak at 288 nm and the Fourier-transform infrared spectroscopy (FTIR) analysis confirmed the existence of the chitosan. Further, the synthesized Ch nanoparticles showed size diameter in the range of 134 ± 58 nm as measured using ImageJ. In the electrospun PU/chitosan graft, the fiber diameter and pore size diameter was found to be reduced compared to the pure PU owing to incorporation of chitosan into PU matrix. The FTIR spectrum revealed the presence of chitosan in the prepared nanocomposite membrane by the formation of the hydrogen bond and peak shift of CH and NH stretching. Moreover, the contact angle measurements revealed that the prepared graft showed decreased contact angle indicating hydrophilic nature compared to the pristine PU. The cytocompatibility studies revealed the non-toxic behavior of the fabricated graft. Hence, the prepared graft exhibiting significant physiochemical and non-toxic properties may be a plausible candidate for cardiovascular graft applications.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects; Blood Vessel Prosthesis Implantation/instrumentation*
  2. Phang ZH, Miskon MFB, Ibrahim SB
    J Med Case Rep, 2018 Jul 18;12(1):211.
    PMID: 30016981 DOI: 10.1186/s13256-018-1751-7
    BACKGROUND: Blunt trauma causing brachial artery injury in a young patient is very rare. Cases of brachial artery injury may be associated with closed elbow dislocation or instability. Elbow dislocation may not be evident clinically and radiologically on initial presentation.

    CASE PRESENTATION: This is a case of a 37-year-old, right-hand dominant, Malay man who fell approximately 6 meters from a rambutan tree and his left arm hit the tree trunk on his way down. He was an active tobacco smoker with a 20 pack year smoking history. On clinical examination, Doppler signals over his radial and ulnar arteries were poor. He proceeded with emergency computed tomography angiogram of his left upper limb which showed non-opacification of contrast at the distal left brachial artery just before the bifurcation of the left brachial artery at his left elbow joint. Radiographs and computed tomography scan also showed undisplaced fracture of left lateral epicondyle and radial head with no evidence of elbow dislocation. He subsequently underwent left brachial to brachial artery bypass which was done using reversed saphenous vein graft and recovered well. His fractures were treated using 90 degree long posterior splint for 2 weeks and he was then allowed early range of motion of the left elbow. This patient developed left elbow dislocation 6 weeks postoperatively. Closed manipulative reduction of his left elbow resulted in incomplete reduction. The functional outcome of his left elbow was limited with a range of motion of left elbow of 0-45 degrees. However, he was not keen for surgery to stabilize his elbow joint during his last follow-up 6 months post injury.

    CONCLUSIONS: This is an uncommon case of brachial artery injury in a civilian caused by blunt trauma associated with occult elbow instability/dislocation and minor fractures around the elbow joint. The treatment of brachial artery injury with clinical evidence of distal ischemia is surgical revascularization. The possibility of elbow instability and dislocation need to be considered in all cases of brachial artery injury because early radiographs and computed tomography scans may be normal. Short-term posterior splint immobilization is not sufficient to prevent recurrent dislocations.

    Matched MeSH terms: Blood Vessel Prosthesis Implantation
  3. Riahi M, Ang HL, Jones M, Prachasilchai P, Baruteau AE, Promphan W, et al.
    Circ Cardiovasc Interv, 2018 04;11(4):e005923.
    PMID: 29618579 DOI: 10.1161/CIRCINTERVENTIONS.117.005923
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/instrumentation*; Heart Valve Prosthesis Implantation/methods
  4. Jamayet NB, Kirangi JK, Husein A, Alam MK
    Eur J Dent, 2017 4 25;11(1):130-134.
    PMID: 28435380 DOI: 10.4103/1305-7456.202636
    Enucleation and evisceration are the most common surgical procedures that are performed to manage tumor, trauma, and infection. Given the consequences of surgical intervention, the conditions of the remaining eye socket may affect future prosthetic rehabilitation. A custom-made ocular prosthesis can be used to help restore the esthetics and functional defects and to improve the quality of life of patients with such conditions. An assessment must be performed on the prosthetic outcome before rehabilitation. The etiology of defect, type of surgery, condition of the remaining socket, and patient's age should all be considered. This report discusses three different etiological eye defects that have undergone enucleation and evisceration and describes the factors that have a significant role in the esthetic and functional outcome of the prosthesis. This report should serve as a helpful aid for maxillofacial prosthodontists to understand the primary objective of rehabilitating each eye defect and to meet patient expectations.
    Matched MeSH terms: Prosthesis Implantation
  5. Patil PG, Nimbalkar-Patil S
    J Indian Prosthodont Soc, 2017 2 22;17(1):84-88.
    PMID: 28216851 DOI: 10.4103/0972-4052.176538
    INTRODUCTION: Maxillary obturator prosthesis is more frequent treatment modality than surgical reconstruction for maxillectomy in patients suffering from oral cancer. The obturators often become heavy and hence are hollowed out in the defect portion to reduce its weight as a standard practice.

    MATERIALS AND METHODS: The processing technique described the incorporation of the preshaped "wax-bolus" during packing procedure of the Obturtor prosthesis and eliminated later by melting it once the curing procedure is completed.

    RESULTS: This article is a single step procedure resulting into the closed-hollow obturator as single unit with uniform wall thickness around the hollow space ensuring the least possible weight of the hollow obturator.

    CONCLUSION: This processing technique achieves predictable internal dimension of the hollow space providing uniform wall thickness of the obturator.

    Matched MeSH terms: Prosthesis Implantation
  6. Aggarwal H, Kumar P, Eachempati P, Alvi HA
    J Prosthodont, 2016 Dec;25(8):687-693.
    PMID: 26447725 DOI: 10.1111/jopr.12369
    Enucleation is the removal of the entire globe of the eye and a portion of the optic nerve, while evisceration involves the removal of the contents of the globe leaving the sclera, extraocular muscles, and optic nerve. Following enucleation or evisceration, intraorbital implants are routinely placed to enhance the prosthetic outcome in addition to restoring the lost orbital volume. Current practice employs intraorbital implants made of nonporous silicone, hydroxyapatite, or porous polyethylene. Intraorbital implant selection and placement, being a highly demanding procedure in terms of knowledge, skill, and expertise, may be associated with a multiplicity of technical and surgical errors. Complications are usually minimal with these implants, but they do occur. The literature reveals many articles related to intraorbital implants, their benefits, and complications; however, the literature regarding the effect of various intraorbital implant situations on the subsequent prosthetic rehabilitation is markedly scarce. Moreover, the need for interdisciplinary surgical and prosthetic interventions required for successful rehabilitation in cases of compromised implant situations has been underemphasized. Hence, this review aimed to evaluate the effect of different intraorbital implant situations on ocular rehabilitation and the required interdisciplinary surgical and prosthetic treatment approach for rehabilitation of enucleated/eviscerated sockets with compromised implant situations, to provide a critical appraisal, and to present a simplified management strategy.
    Matched MeSH terms: Prosthesis Implantation*
  7. Khang NC, Zainal AA
    Med J Malaysia, 2016 02;71(1):17-22.
    PMID: 27130738
    BACKGROUND: This is a single institutional review of aortoiliac pseudoaneurysm of various aetiologies managed with endovascular stent graft repair.

    METHODS: From 2009 to 2014, 16 patients had endovascular stent graft inserted for pseudoaneurysm of the thoracic aorta, abdominal aorta and iliac arteries in Hospital Kuala Lumpur. Co-morbidity, causative agents, in-hospital mortality, complications and outcomes were examined.

    RESULTS: The average age was 59.1 years (range 36-77). Comorbidities include hypertension, diabetes mellitus, tuberculosis, prior infection and previous open aneurysmal repair. All patients had raised WBC (>10.0x10(9) /L), ESR or Creactive protein on admission while 50% of patients had fever. Blood cultures were positive in 4 patients. All patients were given antibiotics. Only one in-hospital mortality was noted at day-47 post-procedure. Two patients died of aortoenteric fistula at district hospital eight and 16 months later. One patient died of chronic graft infection two years later. One died of unrelated cause. One patient developed type IB endoleak from internal iliac artery two years later and surgical ligation was performed. The average follow up was 15.8 months.

    CONCLUSION: Endovascular stent graft repair for pseudoaneurysm is a viable option compared to open surgery. It is less invasive, has lower operative morbidity and fair outcomes. However, some cases may be due to inflammatory aortitis instead of infective pseudoaneurysm, given the frequent culture-negative results. In order to obtain high yield of bacteria culture for infected pseudoaneurysm, open repair with tissue culture is still the main mode of treatment especially for patients with low comorbidity.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  8. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S
    Am J Phys Med Rehabil, 2014 Sep;93(9):809-23.
    PMID: 24743451 DOI: 10.1097/PHM.0000000000000094
    The purpose of this study was to find the scientific evidence pertaining to various transfemoral suspension systems to provide selection criteria for clinicians. To this end, databases of PubMed, Web of Science, and ScienceDirect were explored. The following key words, as well as their combinations and synonyms, were used for the search: transfemoral prosthesis, prosthetic suspension, lower limb prosthesis, above-knee prosthesis, prosthetic liner, transfemoral, and prosthetic socket. The study design, research instrument, sampling method, outcome measures, and protocols of articles were reviewed. On the basis of the selection criteria, 16 articles (11 prospective studies and 5 surveys) were reviewed. The main causes of reluctance to prosthesis, aside from energy expenditure, were socket-related problems such as discomfort, perspiration, and skin problems. Osseointegration was a suspension option, yet it is rarely applied because of several drawbacks, such as extended rehabilitation process, risk for fracture, and infection along with excessive cost. In conclusion, no clinical evidence was found as a "standard" system of suspension and socket design for all transfemoral amputees. However, among various suspension systems for transfemoral amputees, the soft insert or double socket was favored by most users in terms of function and comfort.
    Matched MeSH terms: Prosthesis Implantation/instrumentation
  9. Qureshi AU, Abbaker AE, Sivalingam S, Latiff HA
    PMID: 24668992 DOI: 10.1177/2150135113509819
    Valved bovine jugular vein (Contegra) conduit is considered a suitable choice for pediatric population with congenital heart defect requiring right ventricle to main pulmonary artery connection. Intermediate follow-up studies have shown the propensity of developing distal conduit stenosis and valve thrombosis. We present a rare case of aneurysmal dilatation of the conduit leading to valve failure requiring conduit explantation.
    Matched MeSH terms: Blood Vessel Prosthesis Implantation/adverse effects*; Heart Valve Prosthesis Implantation/adverse effects*
  10. Ulum MF, Arafat A, Noviana D, Yusop AH, Nasution AK, Abdul Kadir MR, et al.
    Mater Sci Eng C Mater Biol Appl, 2014 Mar 1;36:336-44.
    PMID: 24433920 DOI: 10.1016/j.msec.2013.12.022
    Biodegradable metals such as magnesium, iron and their alloys have been known as potential materials for temporary medical implants. However, most of the studies on biodegradable metals have been focusing on optimizing their mechanical properties and degradation behavior with no emphasis on improving their bioactivity behavior. We therefore investigated the possibility of improving iron biodegradation rate and bioactivity by incorporating various bioactive bioceramics. The iron-based bioceramic (hydroxyapatite, tricalcium phosphate and biphasic calcium phosphate) composites were prepared by mechanical mixing and sintering process. Degradation studies indicated that the addition of bioceramics lowered the corrosion potential of the composites and slightly increased their corrosion rate compared to that of pure iron. In vitro cytotoxicity results showed an increase of cellular activity when rat smooth muscle cells interacted with the degrading composites compared to pure iron. X-ray radiogram analysis showed a consistent degradation progress with that found in vivo and positive tissue response up to 70 days implantation in sheep animal model. Therefore, the iron-based bioceramic composites have the potential to be used for biodegradable bone implant applications.
    Matched MeSH terms: Prosthesis Implantation
  11. Buzayan MM, Yunus NB
    J Indian Prosthodont Soc, 2014 Mar;14(1):16-23.
    PMID: 24604993 DOI: 10.1007/s13191-013-0343-x
    One of the considerable challenges for screw-retained multi-unit implant prosthesis is achieving a passive fit of the prosthesis' superstructure to the implants. This passive fit is supposed to be one of the most vital requirements for the maintenance of the osseointegration. On the other hand, the misfit of the implant supported superstructure may lead to unfavourable complications, which can be mechanical or biological in nature. The manifestations of these complications may range from fracture of various components in the implant system, pain, marginal bone loss, and even loss of osseointegration. Thus, minimizing the misfit and optimizing the passive fit should be a prerequisite for implant survival and success. The purpose of this article is to present and summarize some aspects of the passive fit achieving and improving methods. The literature review was performed through Science Direct, Pubmed, and Google database. They were searched in English using the following combinations of keywords: passive fit, implant misfit and framework misfit. Articles were selected on the basis of whether they had sufficient information related to framework misfit's related factors, passive fit and its achievement techniques, marginal bone changes relation with the misfit, implant impression techniques and splinting concept. The related references were selected in order to emphasize the importance of the passive fit achievement and the misfit minimizing. Despite the fact that the literature presents considerable information regarding the framework's misfit, there was not consistency in literature on a specified number or even a range to be the acceptable level of misfit. On the other hand, a review of the literature revealed that the complete passive fit still remains a tricky goal to be achieved by the prosthodontist.
    Matched MeSH terms: Prosthesis Implantation
  12. Buzayan MM
    Prosthet Orthot Int, 2014 Feb;38(1):62-7.
    PMID: 23625838 DOI: 10.1177/0309364613484052
    Mid-facial defect is one of the most disfiguring and impairing defects. A design of prosthesis that is aesthetic and stable can be precious to a patient who has lost part of his face due to surgical excision. Prosthesis can restore the patients' self-esteem and confidence, which affects the patients and their life style. The aim of this case report is to describe a technique of mid-facial silicone prosthesis fabrication.
    Matched MeSH terms: Prosthesis Implantation*
  13. Gholizadeh H, Abu Osman NA, Eshraghi A, Ali S, Razak NA
    Clin Biomech (Bristol, Avon), 2014 Jan;29(1):87-97.
    PMID: 24315710 DOI: 10.1016/j.clinbiomech.2013.10.013
    Today a number of prosthetic suspension systems are available for transtibial amputees. Consideration of an appropriate suspension system can ensure that amputee's functional needs are satisfied. The higher the insight to suspension systems, the easier would be the selection for prosthetists. This review attempted to find scientific evidence pertaining to various transtibial suspension systems to provide selection criteria for clinicians.
    Matched MeSH terms: Prosthesis Implantation/instrumentation
  14. Yakub MA, Dillon J, Krishna Moorthy PS, Pau KK, Nordin MN
    Eur J Cardiothorac Surg, 2013 Oct;44(4):673-81.
    PMID: 23447474 DOI: 10.1093/ejcts/ezt093
    Contemporary experience with mitral valve (MV) repair in the rheumatic population is limited. We aimed to examine the long-term outcomes of rheumatic MV repair, to identify the predictors of durability and to compare the repair for rheumatic and degenerative MVs.
    Matched MeSH terms: Heart Valve Prosthesis Implantation/adverse effects; Heart Valve Prosthesis Implantation/methods*
  15. Nor Elina NS, Naresh G, Hanif H, Zainal AA
    Med J Malaysia, 2013 Jun;68(3):239-44.
    PMID: 23749014 MyJurnal
    Matched MeSH terms: Blood Vessel Prosthesis Implantation*
  16. Abu Bakar N, Lee CL
    Med J Malaysia, 2013;68(1):73-5.
    PMID: 23466774
    Osteo-odontokeratoprosthesis (OOKP) surgery is a technique used to replace damaged cornea in blind patients for whom cadaveric transplantation is not feasible. OOKP surgery is a complex procedure requiring lifetime follow-up. The preservation of the osteo-odontolamina is the vital feature in maintaining the stability of the OOKP. Early detection of lamina resorption enables early prophylactic measures to be taken and prevent resorption-related complications. This case illustrates the radiological findings of the first OOKP surgery in Malaysia and the role of multidetector computed tomography (MDCT) in postoperative management of OOKP surgery.
    Matched MeSH terms: Prosthesis Implantation
  17. Norhani Mohidin, Chia, Jho Yan, Mohd Norhafizun Mohd Saman, Nazeem Desai
    MyJurnal
    Patients who lost their eyes as results of accidents or diseases (e.g. retinoblastoma) usually underwent enucleation or evisceration. They were then fi tted with ocular prosthesis to prevent collapse of the globe and also for cosmetic effects. Custom made ocular prosthesis is almost unheard of in this country for most hospitals supply ready-made (stock) prosthesis. The cosmetic results of stock prosthesis are often unsatisfactory. Besides being uncomfortable, stock prosthesis may also induce allergic reaction that may lead to papillary conjunctivitis. The Optometry Clinic at UKM started its custom made prosthetic service in 2010. We described here two cases of patients who complained of discomfort with their old stock prosthesis and re-fitted with custom made prosthesis. We also highlight the importance of proper hygiene and maintenance so that ocular prosthesis can be used for as long as possible. This article aims to create awareness among eye care practitioners and showcase the cosmetic benefi ts of custom made ocular prosthesis.
    Study site: Optometry clinic, Universiti Kebangsaan Malaysia, Kuala Lumpur, Malaysia


    Matched MeSH terms: Prosthesis Implantation
  18. Syed A, Zainal AA, Hanif H, Naresh G
    Med J Malaysia, 2012 Dec;67(6):610-2.
    PMID: 23770955 MyJurnal
    This is our initial report on the first 4 cases of infra-renal abdominal aortic aneurysm undergoing Endovascular Aneurysm Repair (EVAR) with local anaesthesia, controlled sedation and monitoring by an anaesthetist. All four patients were males with a mean age of 66.7 years. Only one required ICU stay of two days for cardiac monitoring due to bradycardia and transient hypotension post procedure. No mortality or major post operative morbidity was recorded and the mean hospital stay post procedure was 3.5 days (range 2-5 days).
    Matched MeSH terms: Blood Vessel Prosthesis Implantation
  19. Syed Alwi SA, Zainal Ariffin A, Hanif H, Naresh G
    Med J Malaysia, 2012 Oct;67(5):503-5.
    PMID: 23770868
    This is our initial report on the first 4 cases of infra-renal abdominal aortic aneurysms undergoing Endovascular Aneurysm Repair (EVAR) with local anaesthesia, controlled sedation and monitoring by an anaesthetist. All 4 patients were males with a mean age of 66.7 years. Only one (1) required ICU stay of 2 days for cardiac monitoring due to bradycardia and transient hypotension post procedure. No mortality or major post operative morbidity was recorded and the mean hospital stay post procedure was 3.5 days (range 2-5 days).
    Matched MeSH terms: Blood Vessel Prosthesis Implantation
  20. Haron H, Yusof MR, Maskon O, Ooi J, Rahman MR
    Heart Surg Forum, 2012 Feb;15(1):E59-60.
    PMID: 22360910 DOI: 10.1532/HSF98.20111000
    Papillary fibroelastoma is a rare primary tumor of the heart valves. This lesion can occur on any of the valves or endothelial surface of the heart and has been detected by echocardiography, by cardiac catheterization, during open heart operations for other conditions, and at autopsy. Because of the potential for comorbidities, this tumor should be removed. We present the case of an elderly man with a diagnosis of severe mitral valve regurgitation and moderate tricuspid valve regurgitation who was suspected to have a tricuspid valve vegetation. Mitral valve replacement, tricuspid valve repair, and excision of the lesion were performed successfully. A histologic examination of the vegetation confirmed it to be a papillary fibroelastoma. We present this case to emphasize the rarity of this tumor and the importance of a correct diagnosis to avoid delaying its prompt and definitive management.
    Matched MeSH terms: Heart Valve Prosthesis Implantation
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links