Displaying publications 21 - 40 of 269 in total

Abstract:
Sort:
  1. Lee OW, Mao D, Savkovic B, Wunderlich J, Nicholls N, Jeffreys E, et al.
    Ear Hear, 2023 01 14;44(4):776-786.
    PMID: 36706073 DOI: 10.1097/AUD.0000000000001325
    OBJECTIVES: Cardiac responses (e.g., heart rate changes) due to an autonomous response to sensory stimuli have been reported in several studies. This study investigated whether heart rate information extracted from functional near-infrared spectroscopy (fNIRS) data can be used to assess the discrimination of speech sounds in sleeping infants. This study also investigated the adaptation of the heart rate response over multiple, sequential stimulus presentations.

    DESIGN: fNIRS data were recorded from 23 infants with no known hearing loss, aged 2 to 10 months. Speech syllables were presented using a habituation/dishabituation test paradigm: the infant's heart rate response was first habituated by repeating blocks of one speech sound; then, the heart rate response was dishabituated with the contrasting (novel) speech sound. This stimulus presentation sequence was repeated for as long as the infants were asleep.

    RESULTS: The group-level average heart rate response to the novel stimulus was greater than that to the habituated first sound, indicating that sleeping infants were able to discriminate the speech sound contrast. A significant adaptation of the heart rate responses was seen over the session duration.

    CONCLUSION: The dishabituation response could be a valuable marker for speech discrimination, especially when used in conjunction with the fNIRS hemodynamic response.

    Matched MeSH terms: Heart Rate
  2. Razak MR, Aris AZ, Yusoff FM, Yusof ZNB, Abidin AAZ, Kim SD, et al.
    Environ Geochem Health, 2023 Jun;45(6):3567-3583.
    PMID: 36450975 DOI: 10.1007/s10653-022-01442-2
    Bisphenol A (BPA) is a well-known endocrine-disrupting compound that causes several toxic effects on human and aquatic organisms. The restriction of BPA in several applications has increased the substituted toxic chemicals such as bisphenol F (BPF) and bisphenol S (BPS). A native tropical freshwater cladoceran, Moina micrura, was used as a bioindicator to assess the adverse effects of bisphenol analogues at molecular, organ, individual and population levels. Bisphenol analogues significantly upregulated the expressions of stress-related genes, which are the haemoglobin and glutathione S-transferase genes, but the sex determination genes such as doublesex and juvenile hormone analogue genes were not significantly different. The results show that bisphenol analogues affect the heart rate and mortality rate of M. micrura. The 48-h lethal concentration (LC50) values based on acute toxicity for BPA, BPF and BPS were 611.6 µg L-1, 632.0 µg L-1 and 819.1 µg L-1, respectively. The order of toxicity based on the LC50 and predictive non-effect concentration values were as follows: BPA > BPF > BPS. Furthermore, the incorporated method combining the responses throughout the organisation levels can comprehensively interpret the toxic effects of bisphenol analogues, thus providing further understanding of the toxicity mechanisms. Moreover, the output of this study produces a comprehensive ecotoxicity assessment, which provides insights for the legislators regarding exposure management and mitigation of bisphenol analogues in riverine ecosystems.
    Matched MeSH terms: Heart Rate
  3. Ahmad HAB, El-Badawy IM, Singh OP, Hisham RB, Malarvili MB
    Technol Health Care, 2018;26(4):573-579.
    PMID: 29758955 DOI: 10.3233/THC-171067
    BACKGROUND: Fetal heart rate (FHR) monitoring device is highly demanded to assess the fetus health condition in home environments. Conventional standard devices such as ultrasonography and cardiotocography are expensive, bulky and uncomfortable and consequently not suitable for long-term monitoring. Herein, we report a device that can be used to measure fetal heart rate in clinical and home environments.

    METHODS: The proposed device measures and displays the FHR on a screen liquid crystal display (LCD). The device consists of hardware that comprises condenser microphone sensor, signal conditioning, microcontroller and LCD, and software that involves the algorithm used for processing the conditioned fetal heart signal prior to FHR display. The device's performance is validated based on analysis of variance (ANOVA) test.

    RESULTS: FHR data was recorded from 22 pregnant women during the 17th to 37th week of gestation using the developed device and two standard devices; AngelSounds and Electronic Stethoscope. The results show that F-value (1.5) is less than F𝑐𝑟𝑖𝑡, (3.1) and p-value (p> 0.05). Accordingly, there is no significant difference between the mean readings of the developed and existing devices. Hence, the developed device can be used for monitoring FHR in clinical and home environments.

    Matched MeSH terms: Heart Rate, Fetal/physiology*
  4. Teoh AN, Hilmert C
    Br J Health Psychol, 2018 11;23(4):1040-1065.
    PMID: 30084181 DOI: 10.1111/bjhp.12337
    PURPOSE: The stress-buffering hypothesis (Cohen & McKay, 1984, Handbook of psychology and health IV: Social psychological aspects of health (pp. 253-256). Hillsdale, NJ: Lawrence Erlbaum) suggests that one way social support enhances health is by attenuating cardiovascular reactivity (CVR) to stress. Research that has tested this hypothesis has reported inconsistent findings. In this review, we systematically reviewed those findings and proposed a dual-effect model of social support and CVR as a potential explanation for the inconsistency in the literature. Specifically, we proposed that when participants are more engaged during a stressor, social support acts primarily as social comfort, attenuating CVR; and when participants are not engaged, social support acts primarily as social encouragement, elevating CVR.

    METHODS: We reviewed 22 previous studies that (1) empirically manipulated social support in a stressful situation, (2) measured CVR, and (3) tested a moderator of social support effects on CVR.

    RESULTS: Although a majority of studies reported a CVR-mitigating effect of social support resulting in an overall significant combined p-value, we found that there were different effects of social support on CVR when we considered high- and low-engagement contexts. That is, compared to control conditions, social support lowered CVR in more engaging situations but had no significant effect on CVR in less engaging situations.

    CONCLUSION: Our results suggest that a dual-effect model of social support effects on CVR may better capture the nature of social support, CVR, and health associations than the buffering hypothesis and emphasize a need to better understand the health implications of physiological reactivity in various contexts. Statement of contribution What is already known on this subject? According to the stress-buffering hypothesis (Cohen & McKay, ), one pathway social support benefits health is through mitigating the physiological arousal caused by stress. However, previous studies that examined the effects of social support on blood pressure and heart rate changes were not consistently supporting the hypothesis. Some studies reported that social support causes elevations in cardiovascular reactivity (CVR) to stress (Anthony & O'Brien, ; Hilmert, Christenfeld, & Kulik, ; Hilmert, Kulik, & Christenfeld, ) and others showed no effect of social support on CVR (Christian & Stoney, ; Craig & Deichert, ; Gallo, Smith, & Kircher, ). What does this study add? When participants were in more engaging conditions, social support decreased CVR relative to no support. When participants were in less engaging conditions, social support did not have a significant effect on CVR. Provide an alternative way to explain the ways social support affects cardiac health.

    Matched MeSH terms: Heart Rate/physiology*
  5. Viswabhargav CSS, Tripathy RK, Acharya UR
    Comput Biol Med, 2019 05;108:20-30.
    PMID: 31003176 DOI: 10.1016/j.compbiomed.2019.03.016
    Sleep is a prominent physiological activity in our daily life. Sleep apnea is the category of sleep disorder during which the breathing of the person diminishes causing the alternation in the upper airway resistance. The electrocardiogram derived respiration (EDR) and heart rate (RR-time-series) signals are normally used for the detection of sleep apnea as these two signals capture cardio-pulmonary activity information. Hence, the analysis of these two signals provides vital information about sleep apnea. In this paper, we propose the novel sparse residual entropy (SRE) features for the automated detection of sleep apnea using EDR and heart rate signals. The features required for the automated detection of sleep apnea are extracted in three steps: (i) atomic decomposition based residual estimation from both EDR and heart rate signals using orthogonal matching pursuit (OMP) with different dictionaries, (ii) estimation of probabilities from each sparse residual, and (iii) calculation of the entropy features. The proposed SRE features are fed to the combination of fuzzy K-means clustering and support vector machine (SVM) to pick the best performing classifier. The experimental results demonstrate that the proposed SRE features with radial basis function (RBF) kernel-based SVM classifier yielded higher performance with accuracy, sensitivity and specificity values of 78.07%, 78.01%, and 78.13%, respectively with Fourier dictionary and 10-fold cross-validation. For subject-specific or leave-one-out validation case, the SVM classifier has sensitivity and specificity of 85.43% and 92.60%, respectively using SRE features with Fourier dictionary (FD).
    Matched MeSH terms: Heart Rate*
  6. Faust O, Razaghi H, Barika R, Ciaccio EJ, Acharya UR
    Comput Methods Programs Biomed, 2019 Jul;176:81-91.
    PMID: 31200914 DOI: 10.1016/j.cmpb.2019.04.032
    BACKGROUND AND OBJECTIVE: Sleep is an important part of our life. That importance is highlighted by the multitude of health problems which result from sleep disorders. Detecting these sleep disorders requires an accurate interpretation of physiological signals. Prerequisite for this interpretation is an understanding of the way in which sleep stage changes manifest themselves in the signal waveform. With that understanding it is possible to build automated sleep stage scoring systems. Apart from their practical relevance for automating sleep disorder diagnosis, these systems provide a good indication of the amount of sleep stage related information communicated by a specific physiological signal.

    METHODS: This article provides a comprehensive review of automated sleep stage scoring systems, which were created since the year 2000. The systems were developed for Electrocardiogram (ECG), Electroencephalogram (EEG), Electrooculogram (EOG), and a combination of signals.

    RESULTS: Our review shows that all of these signals contain information for sleep stage scoring.

    CONCLUSIONS: The result is important, because it allows us to shift our research focus away from information extraction methods to systemic improvements, such as patient comfort, redundancy, safety and cost.

    Matched MeSH terms: Heart Rate*
  7. Yildirim O, Talo M, Ay B, Baloglu UB, Aydin G, Acharya UR
    Comput Biol Med, 2019 10;113:103387.
    PMID: 31421276 DOI: 10.1016/j.compbiomed.2019.103387
    In this study, a deep-transfer learning approach is proposed for the automated diagnosis of diabetes mellitus (DM), using heart rate (HR) signals obtained from electrocardiogram (ECG) data. Recent progress in deep learning has contributed significantly to improvement in the quality of healthcare. In order for deep learning models to perform well, large datasets are required for training. However, a difficulty in the biomedical field is the lack of clinical data with expert annotation. A recent, commonly implemented technique to train deep learning models using small datasets is to transfer the weighting, developed from a large dataset, to the current model. This deep learning transfer strategy is generally employed for two-dimensional signals. Herein, the weighting of models pre-trained using two-dimensional large image data was applied to one-dimensional HR signals. The one-dimensional HR signals were then converted into frequency spectrum images, which were utilized for application to well-known pre-trained models, specifically: AlexNet, VggNet, ResNet, and DenseNet. The DenseNet pre-trained model yielded the highest classification average accuracy of 97.62%, and sensitivity of 100%, to detect DM subjects via HR signal recordings. In the future, we intend to further test this developed model by utilizing additional data along with cloud-based storage to diagnose DM via heart signal analysis.
    Matched MeSH terms: Heart Rate*
  8. Ooi CH, Ng SK, Omar EA
    Appl Physiol Nutr Metab, 2020 May;45(5):513-519.
    PMID: 31675478 DOI: 10.1139/apnm-2019-0553
    There is emerging evidence that hydrogen-rich water (H2-water) has beneficial effects on the physiological responses to exercise. However, few studies investigate its ergogenic potential. This randomized controlled trial examined the effects of H2-water ingestion on physiological responses and exercise performance during incremental treadmill running. In a double-blind crossover design, 14 endurance-trained male runners (age, 34 ± 4 years; body mass, 63.1 ± 7.2 kg; height, 1.72 ± 0.05 m) were randomly assigned to ingest 2 doses of 290-mL H2-water or placebo on each occasion. The first bolus was given before six 4-min submaximal running bouts, and the second bolus was consumed before the maximal incremental running test. Expired gas, heart rate (HR), and ratings of perceived exertion (RPE) were recorded; blood samples were collected at the end of each submaximal stage and post maximal running test. Cardiorespiratory responses, RPE, and blood gas indices were not significantly different at each submaximal running intensity (range: 34%-91% maximal oxygen uptake) between H2-water and placebo trials. No statistical difference was observed in running time to exhaustion (618 ± 126 vs. 619 ± 113 s), maximal oxygen uptake (56.9 ± 4.4 vs. 57.1 ± 4.7 mL·kg-1·min-1), maximal HR (184 ± 7 vs. 184 ± 7 beat·min-1), and RPE (19 ± 1 vs. 19 ± 1) in the runners between the trials. The results suggest that the ingestion of 290 mL of H2-water before submaximal treadmill running and an additional dose before the subsequent incremental running to exhaustion were not sufficiently ergogenic in endurance-trained athletes. Novelty Acute ingestion of H2-water does not seem to be ergogenic for endurance performance. A small dose of H2-water does not modulate buffering capacity during intense endurance exercise in athletes.
    Matched MeSH terms: Heart Rate/physiology
  9. Lan BL, Liew YW, Toda M, Kamsani SH
    Chaos, 2020 May;30(5):053137.
    PMID: 32491883 DOI: 10.1063/1.5130524
    Complex dynamical systems can shift abruptly from a stable state to an alternative stable state at a tipping point. Before the critical transition, the system either slows down in its recovery rate or flickers between the basins of attraction of the alternative stable states. Whether the heart critically slows down or flickers before it transitions into and out of paroxysmal atrial fibrillation (PAF) is still an open question. To address this issue, we propose a novel definition of cardiac states based on beat-to-beat (RR) interval fluctuations derived from electrocardiogram data. Our results show the cardiac state flickers before PAF onset and termination. Prior to onset, flickering is due to a "tug-of-war" between the sinus node (the natural pacemaker) and atrial ectopic focus/foci (abnormal pacemakers), or the pacing by the latter interspersed among the pacing by the former. It may also be due to an abnormal autonomic modulation of the sinus node. This abnormal modulation may be the sole cause of flickering prior to termination since atrial ectopic beats are absent. Flickering of the cardiac state could potentially be used as part of an early warning or screening system for PAF and guide the development of new methods to prevent or terminate PAF. The method we have developed to define system states and use them to detect flickering can be adapted to study critical transition in other complex systems.
    Matched MeSH terms: Heart Rate/physiology
  10. Chandran R, Serra-Serra V, Sellers SM, Redman CW
    Br J Obstet Gynaecol, 1993 Feb;100(2):139-44.
    PMID: 8476805
    OBJECTIVE: To establish reference ranges for the human fetal middle cerebral artery pulsatility index (MCA PI) for the local obstetric population, and to compare computerised antenatal fetal heart rate (FHR) analysis with the MCA PI as indicators of fetal compromise.

    DESIGN: Prospective data collection for selected patients.

    SETTING: High risk pregnancy unit of a teaching hospital.

    SUBJECTS: Group 1 consisted of 18 healthy women with uncomplicated singleton pregnancies. Group 2 consisted of 27 women admitted to the high risk pregnancy unit over a 9 month period with intrauterine growth retardation and other related problems; all these women were delivered by prelabour caesarean section.

    INTERVENTION: Serial Duplex sonography to determine fetal MCA PI in Groups 1 and 2. Serial FHR analysis using computerised numerical techniques in Group 2 only.

    MAIN OUTCOME MEASURES: Serial MCA PI values from 24 to 39 completed weeks of gestation in Group 1. Comparison of serial MCA PI values with FHR analysis in relation to fetal outcome in Group 2.

    RESULTS: In Group 1 the MCA PI diminished significantly as gestation advanced from 1.73 (SD 0.25) at 24 weeks to 1.38 (SD 0.26) at 39 weeks (P < 0.01). In Group 2 eleven babies were hypoxaemic at delivery: all had low MCA PI values while only nine had an abnormal FHR prior to delivery.

    CONCLUSION: In normal pregnancy, there is a fall in the fetal MCA PI with advancing gestation which probably reflects a decreasing vascular resistance to fetal cerebral blood flow. Hypoxaemia at delivery appeared to be better recognised by the fetal MCA flow velocity waveform than the FHR analysis. This increased sensitivity, however, was achieved at the expense of a reduced specificity. Larger studies are needed to confirm the findings of this preliminary investigation.

    Matched MeSH terms: Heart Rate, Fetal/physiology*
  11. Doufesh H, Ibrahim F, Ismail NA, Wan Ahmad WA
    J Altern Complement Med, 2014 Jul;20(7):558-62.
    PMID: 24827587 DOI: 10.1089/acm.2013.0426
    OBJECTIVES: This study investigated the effect of Muslim prayer (salat) on the α relative power (RPα) of electroencephalography (EEG) and autonomic nervous activity and the relationship between them by using spectral analysis of EEG and heart rate variability (HRV).

    METHODS: Thirty healthy Muslim men participated in the study. Their electrocardiograms and EEGs were continuously recorded before, during, and after salat practice with a computer-based data acquisition system (MP150, BIOPAC Systems Inc., Camino Goleta, California). Power spectral analysis was conducted to extract the RPα and HRV components.

    RESULTS: During salat, a significant increase (p

    Matched MeSH terms: Heart Rate/physiology*
  12. Najafabadi FS, Zahedi E, Mohd Ali MA
    Comput Biol Med, 2006 Mar;36(3):241-52.
    PMID: 16446158
    In this paper, an algorithm based on independent component analysis (ICA) for extracting the fetal heart rate (FHR) from maternal abdominal electrodes is presented. Three abdominal ECG channels are used to extract the FHR in three steps: first preprocessing procedures such as DC cancellation and low-pass filtering are applied to remove noise. Then the algorithm for multiple unknown source extraction (AMUSE) algorithm is fed to extract the sources from the observation signals include fetal ECG (FECG). Finally, FHR is extracted from FECG. The method is shown to be capable of completely revealing FECG R-peaks from observation leads even with a SNR=-200dB using semi-synthetic data.
    Matched MeSH terms: Heart Rate, Fetal*
  13. Palaniappan R, Phon-Amnuaisuk S, Eswaran C
    Int J Cardiol, 2015;190:262-3.
    PMID: 25932800 DOI: 10.1016/j.ijcard.2015.04.175
    Matched MeSH terms: Heart Rate/physiology*
  14. Abu Hanifah R, Mohamed MN, Jaafar Z, Mohsein NA, Jalaludin MY, Majid HA, et al.
    PLoS One, 2013;8(12):e82893.
    PMID: 24349388 DOI: 10.1371/journal.pone.0082893
    BACKGROUND: In adults, heart rate recovery is a predictor of mortality, while in adolescents it is associated with cardio-metabolic risk factors. The aim of this study was to examine the relationship between body composition measures and heart rate recovery (HRR) after step test in Malaysian secondary school students.

    METHODS: In the Malaysian Health and Adolescents Longitudinal Research Team (MyHEART) study, 1071 healthy secondary school students, aged 13 years old, participated in the step test. Parameters for body composition measures were body mass index z-score, body fat percentage, waist circumference, and waist height ratio. The step test was conducted by using a modified Harvard step test. Heart rate recovery of 1 minute (HRR1min) and heart rate recovery of 2 minutes (HRR2min) were calculated by the difference between the peak pulse rate during exercise and the resting pulse rate at 1 and 2 minutes, respectively. Analysis was done separately based on gender. Pearson correlation analysis was used to determine the association between the HRR parameters with body composition measures, while multiple regression analysis was used to determine which body composition measures was the strongest predictor for HRR.

    RESULTS: For both gender groups, all body composition measures were inversely correlated with HRR1min. In girls, all body composition measures were inversely correlated with HRR2min, while in boys all body composition measures, except BMI z-score, were associated with HRR2min. In multiple regression, only waist circumference was inversely associated with HRR2min (p=0.024) in boys, while in girls it was body fat percentage for HRR2min (p=0.008).

    CONCLUSION: There was an inverse association between body composition measurements and HRR among apparently healthy adolescents. Therefore, it is important to identify cardio-metabolic risk factors in adolescent as an early prevention of consequent adulthood morbidity. This reiterates the importance of healthy living which should start from young.

    Matched MeSH terms: Heart Rate/physiology*
  15. Song Y, Sheykhlouvand M
    J Sports Sci Med, 2024 Sep;23(1):672-683.
    PMID: 39228785 DOI: 10.52082/jssm.2024.672
    Technique-specific high-intensity interval training (HIITTS) has been proven to be an effective method to enhance the sport-specific bio-motor abilities of taekwondo athletes. However, studies regarding its effects on comprehensive measures of cardiorespiratory fitness are limited. Furthermore, there is a lack of clarity regarding the extent of individual adaptations to this method compared to HIIT in the form of repeated sprints (HIITRS). This study compared the individual adaptations to HIITRS and HIITTS on cardiorespiratory fitness and anaerobic power in trained taekwondo athletes (age = 19.8 ± 1.3 years; body mass = 75.4 ± 9.1 kg; height = 1.73 ± 0.0 .m). All participants completed three sessions per week of a 60-minute regular taekwondo training. Following the 60-minute training, participants completed 3 sets of 10 × 4 s all-out HIITRS or same sets of repeated kicks with both legs (HIITTS) over a 6-week training period. In both groups, rest intervals were set at 15 seconds between efforts and one minute between sets. Before and after the training period, participants underwent a series of lab- and field-based tests to evaluate cardiorespiratory fitness and bio-motor abilities. Both interventions resulted in significant improvements in maximum oxygen uptake (V̇O2max), O2 pulse (V̇O2/HR), first ventilatory threshold (VT1), second ventilatory threshold (VT2), cardiac output (Q̇max), stroke volume (SV), peak power output (PPO), average power output (APO), squat jump (SJ), and countermovement jump (CMJ). However, linear speed (20-m speed time) and taekwondo-specific agility test (TSAT) only responded to HIITRS. HIITRS resulted in greater changes in V̇O2max, V̇O2/HR, VT2, and Q̇max, and higher percentage of responders in measured parameters than HIITTS. In addition, HIITRS elicited lower inter-individual variability (CV) in percent changes from pre- to post-training in all measured variables. These results suggest that incorporating 3 sessions per week of HIITRS into regular taekwondo training results in significantly greater and more homogenized adaptations in cardiorespiratory fitness and bio-motor abilities than HIITTS among trained taekwondo athletes.
    Matched MeSH terms: Heart Rate/physiology
  16. Herawati I, Mat Ludin AF, Ishak I, Mutalazimah M, Farah NMF
    BMC Public Health, 2025 Mar 11;25(1):962.
    PMID: 40069690 DOI: 10.1186/s12889-025-22139-y
    BACKGROUND: High-intensity interval training and breathing exercises alone have well-documented health benefits in people with hypertension. This study aimed to investigated the effects of combining the two methods on physical health among adults with hypertension.

    METHODS: Ninety-six adults (59.4 ± 9.1 years; 84% female; BMI 22.7 ± 1.6 kg/m2) with hypertension were randomized into one of four groups: Breathing Exercise (BE), High-Intensity Bodyweight Interval Training (HIBIT), Combined Exercise (CE), or a Non-Exercise Control (CON) group. The intervention lasted 10 weeks, with all exercise groups having the same total training time of 3 days per week (BE: 30 min/day; HIBIT: 60 min/day; CE: BE 30 min/day plus HIBIT 60 min/day). Resting heart rate, resting blood pressure, hand grip strength, cardiorespiratory fitness assessed using 6-Minute Walking Test (6MWT) and blood lipids were measured pre- and post-intervention.

    RESULTS: The BE group showed the greatest reduction in systolic blood pressure (SBP) compared to CON, although differences among the exercise groups were not statistically significant. The increase in 6MWT values in the combined exercise group differed significantly compared to the other three groups (p = 0.000 and effect size = 0.296). The combined exercise group showed significant reductions in total cholesterol, LDL and triglyceride levels compared to the control group. The average reduction in total cholesterol levels was 20.8 mg/dL (95% C: -41.9 - 0.4) with an effect size of 0.103. Meanwhile, the decrease in LDL and triglyceride levels was 20.1 mg/dL (95% CI: -37.6--2.5; p = 0.014) and -40.4 mg/dL (95% CI: -82.1-1.3; p = 0.04) with effect sizes of 0.118 and 0.101.

    CONCLUSIONS: In conclusion combined exercise for 10 weeks could lower systolic and diastolic blood pressure, increase CRF, and improved lipid profile. As a clinical implication, the results of this study can be an alternative or complementary approach to treatment for hypertension, potentially reducing the need for medications and their associated side effects.

    TRIAL REGISTRATION: TCTR20230707003 ( http://www.

    CLINICALTRIALS: in.th/ ) registered on 28 January 2023.

    Matched MeSH terms: Heart Rate/physiology
  17. Chang CYM, De Vries M, Groom MJ, Michelini G, Bellato A
    J Health Psychol, 2026 Nov;31(13):5834-5846.
    PMID: 41909939 DOI: 10.1177/13591053261433384
    Difficulties regulating emotions and physiological arousal can heighten stress and anxiety in young adults, lowering quality of life (QoL). This pre-registered study examined whether maladaptive emotion regulation (e.g. expressive suppression) relates to greater emotional and arousal dysregulation (e.g. reduced heart rate variability, HRV) and poorer QoL. 101 young adults (21.1 ± 1.9 years; 73.3% female) in Malaysia completed questionnaires on emotion regulation, stress, anxiety, and QoL, while heart rate was recorded at rest and during exposure to emotion-inducing stimuli. Bootstrapped correlation and mediation analyses revealed that greater emotional dysregulation was associated with lower use of cognitive reappraisal, higher stress/anxiety, and poorer QoL. Cognitive reappraisal related to lower stress/anxiety and better QoL, whereas expressive suppression related to higher anxiety and poorer psychological QoL. Among frequent reappraisers, reduced stress and anxiety predicted better QoL. Promoting cognitive reappraisal may improve wellbeing and help young people cope with emotional challenges.
    Matched MeSH terms: Heart Rate/physiology
  18. Lim YP, Yahya N, Izaham A, Kamaruzaman E, Zainuddin MZ, Wan Mat WR, et al.
    Turk J Med Sci, 2018 Dec 12;48(6):1219-1227.
    PMID: 30541250 DOI: 10.3906/sag-1802-126
    Background/aim: Regional anesthesia for surgery is associated with increased anxiety for patients. This study aimed to compare the
    effect of propofol and dexmedetomidine infusion on perioperative anxiety during regional anesthesia.

    Materials and methods: Eighty-four patients were randomly divided into two groups receiving either study drug infusion. Anxiety
    score, level of sedation using the Bispectral Index and Observer’s Assessment of Alertness and Sedation, hemodynamic stability, and
    overall patient’s feedback on anxiolysis were assessed.

    Results: Both groups showed a significant drop in mean anxiety score at 10 and 30 min after starting surgery. Difference in median
    anxiety scores showed a significant reduction in anxiety score at the end of the surgery in the dexmedetomidine group compared to the
    propofol group. Dexmedetomidine and propofol showed a significant drop in mean arterial pressure in the first 30 min and first 10 min
    respectively. Both drugs demonstrated a significant drop in heart rate in the first 20 min from baseline after starting the drug infusion.
    Patients in the dexmedetomidine group (76.20%) expressed statistically excellent feedback on anxiolysis compared to patients in the
    propofol group (45.20%).

    Conclusion: Dexmedetomidine infusion was found to significantly reduce anxiety levels at the end of surgery compared to propofol
    during regional anesthesia.

    Matched MeSH terms: Heart Rate
  19. Ibrahim MA, Zulkifli SZ, Azmai MNA, Mohamat-Yusuff F, Ismail A
    Toxicol Rep, 2020;7:1039-1045.
    PMID: 32913717 DOI: 10.1016/j.toxrep.2020.08.011
    Early-life exposure to toxic chemicals causes irreversible morphological and physiological abnormalities that may last for a lifetime. The present study aimed to determine the toxicity effect of 3,4-Dichloroaniline (3,4-DCA) on Javanese medaka (Oryzias javanicus) embryos. Healthy embryos were exposed to various 3,4-DCA concentrations for acute toxicity (5, 10, 25, 50, and 100 mg.L-1) and sublethal toxicity (0.10, 0.50, 1.25, 2.50, and 5.00 mg.L-1) for 96 h and 20 days respectively. Acute toxicity test revealed that the median lethal concentration (96h-LC50) was 32.87 mg.L-1 (95 % CI = 27.90-38.74, R2 = 0.95). Sublethal exposure revealed that 1.25 mg.L-1 at 3 days post-exposure (3 dpe) has a significant lower heartrate (120 ± 12.3 beats/min., p heart rate compared to other treatments. Likewise, at 13 dpe, 5.00 mg.L-1 (110.4 ± 17.3 beats/min) and 2.5 mg.L-1 (130.4 ± 8.3 beats/min) were significantly lower (p 
    Matched MeSH terms: Heart Rate
  20. Elsoragaby S, Yahya A, Nawi NM, Mahadi MR, Mairghany M, Muazu A, et al.
    Heliyon, 2020 Nov;6(11):e05332.
    PMID: 33294651 DOI: 10.1016/j.heliyon.2020.e05332
    Measurement of human energy expenditure during crop production helps in the optimization of production operations and costs by identifying steps which that can benefit from the use of appropriate mechanization technologies. This study measures human energy expenditure associated with all 6 major rice (Oryza sativa L.) cultivation operations using two measurement methods-i.e. conventional human energy expenditure method and direct measurement with a Garmin forerunner 35 body media. The aim of this study was to provide a detailed comparison of these two methods and document the human energy costs in a manner that will identify steps to be taken to help optimize agricultural practices. Results (mean + 95%CL) revealed that the total human energy expenditure obtained through the conventional method was 25.5% higher (33.3 ± 1 versus 26.6 ± 1.3) in transplanting and 26.1% higher (30.3 ± 1.9 versus 24.0 ± 2.1) than the human energy expenditure recorded using the Garmin method in broadcast seeding method. Similarly, during the harvesting operation, the conventional measurement and Garmin measurement methods differed significantly, with the conventional method the human energy expenditure was 89.9% higher (3.2 ± 0.4 versus 1.68 ± 0.2) in the fields using the transplanting and 88.7% higher (3.3 ± 0.5 versus 1.8 ± 0.3) in the fields using the broadcast seeding than the human energy expenditure recorded using the Garmin method. When using Garmin method, the human energy expenditure in the case of using the midsize combine harvester was 13.49% lesser (592.4 ± 67.2 versus 522.0 ± 75.1) than the case of using conventional one. Results based on heart rate also indicated that operations such as tillage were less intensive (72 ± 3.3 bpm) compared with operations such as chemicals spraying (135 ± 4 bpm). Although we did not have a criterion measure available to determine which method was the most accurate, the Garmin measurement gives an estimate of actual physical human energy expended in performing a specific task with consider all conditions and thus more information to aid in identifying critical operations that could be optimized and mechanized.
    Matched MeSH terms: Heart Rate
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links