Displaying publications 21 - 29 of 29 in total

Abstract:
Sort:
  1. Chow PKH, Gandhi M, Tan SB, Khin MW, Khasbazar A, Ong J, et al.
    J Clin Oncol, 2018 07 01;36(19):1913-1921.
    PMID: 29498924 DOI: 10.1200/JCO.2017.76.0892
    Purpose Selective internal radiation therapy or radioembolization (RE) shows efficacy in unresectable hepatocellular carcinoma (HCC) limited to the liver. This study compared the safety and efficacy of RE and sorafenib in patients with locally advanced HCC. Patients and Methods SIRveNIB (selective internal radiation therapy v sorafenib), an open-label, investigator-initiated, phase III trial, compared yttrium-90 (90Y) resin microspheres RE with sorafenib 800 mg/d in patients with locally advanced HCC in a two-tailed study designed for superiority/detriment. Patients were randomly assigned 1:1 and stratified by center and presence of portal vein thrombosis. Primary end point was overall survival (OS). Efficacy analyses were performed in the intention-to-treat population and safety analyses in the treated population. Results A total of 360 patients were randomly assigned (RE, 182; sorafenib, 178) from 11 countries in the Asia-Pacific region. In the RE and sorafenib groups, 28.6% and 9.0%, respectively, failed to receive assigned therapy without significant cross-over to either group. Median OS was 8.8 and 10.0 months with RE and sorafenib, respectively (hazard ratio, 1.1; 95% CI, 0.9 to 1.4; P = .36). A total of 1,468 treatment-emergent adverse events (AEs) were reported (RE, 437; sorafenib, 1,031). Significantly fewer patients in the RE than sorafenib group had grade ≥ 3 AEs (36 of 130 [27.7%]) v 82 of 162 [50.6%]; P < .001). The most common grade ≥ 3 AEs were ascites (five of 130 [3.8%] v four of 162 [2.5%] patients), abdominal pain (three [2.3%] v two [1.2%] patients), anemia (zero v four [2.5%] patients), and radiation hepatitis (two [1.5%] v zero [0%] patients). Fewer patients in the RE group (27 of 130 [20.8%]) than in the sorafenib group (57 of 162 [35.2%]) had serious AEs. Conclusion In patients with locally advanced HCC, OS did not differ significantly between RE and sorafenib. The improved toxicity profile of RE may inform treatment choice in selected patients.
    Matched MeSH terms: Yttrium Radioisotopes
  2. Mustaffa Hj. Abdullah, Tan TK
    Samples of Y-Ba-Cu-O superconductor with nominal compositions of YBa2Cu3O7-d + x (weight %) Y2O3 (x = 0 - 15) were prepared by solid state reaction method using the Y2Cu2O5 and BaCuO2 precursors as the starting reagents. The X-ray diffraction (XRD) diffractograms for the doped samples (x> 0) show an additional non-superconducting Y2BaCuO5 (211) phase. The scanning electron microscope (SEM) micrographs show that the smaller Y2BaCuO5 grains are precipitated on the surface of the larger YBa2Cu3O7-d (YBCO) crystals. The grain size of the YBCO decreases with increasing yttria. The superconducting zero resistivity critical temperature (Tco) of the doped samples is very close to the Tco of the YBCO for x < 5, but it seems to be significantly decreasing for larger x. The transport critical current density (J) for x < 5 is enhanced due to magnetic flux pinning process by the 211 phase. However, Jc decreased for larger x due to the increase of weak links at the grain boundaries of the YBCO phase.
    Sampel superkonduktor Y-Ba-Cu-O dengan komposisi nominal YBa2Cu3O7-d + x (% berat) Y2O3 (x = 0 -15) disediakan dengan kaedah tindakbalas keadaan pepejal menggunakan bahan pelopor Y2Cu2O5 dan BaCuO2 Difraktogram pembelauan sinar-X (XRD) bagi sampel yang didop (x > 0) menunjukkan wujudnya fasa tak mensuperkonduksi Y2BaCuO5 (211). Mikrograf mikroskop imbasan elektron (SEM) menunjukkan bahawa butiran Y2BaCuO5 yang lebih kecil itu termendap di atas permukaan hablur YBa2Cu3O7-d yang lebih besar. Saiz hablur YBCO mengecil dengan peningkatan yittria. Suhu genting kerintangan sifar (Tc) bagi sampel yang didop adalah hampir dengan Tco bagi YBCO untuk x<5, tetapi menurun dengan agak cepat untuk x yang lebih besar. Ketumpatan arus genting angkutan (J) untuk x < 5 meningkat jika dibandingkan dengan YBCO disebabkan oleh proses kepinan fluks magnet oleh fasa 211. Walau bagaimanapun, Jc menurun untuk x yang lebih tinggi kerana meningkatnya hubungan lemah pada sempadan butiran fasa YBCO.
    Matched MeSH terms: Yttrium
  3. Wong YH, Tan HY, Kasbollah A, Abdullah BJJ, Yeong CH
    Pharmaceutics, 2019 Nov 12;11(11).
    PMID: 31718079 DOI: 10.3390/pharmaceutics11110596
    INTRODUCTION: Transarterial radioembolization (TARE) has been proven as an effective treatment for unresectable liver tumor. In this study, neutron activated, 153Sm-labeled microspheres were developed as an alternative to 90Y-labeled microspheres for hepatic radioembolization. 153Sm has a theranostic advantage as it emits both therapeutic beta and diagnostic gamma radiations simultaneously, in comparison to the pure beta emitter, 90Y.

    METHODS: Negatively charged acrylic microspheres were labeled with 152Sm ions through electrostatic interactions. In another formulation, the Sm-labeled microsphere was treated with sodium carbonate solution to form the insoluble 152Sm carbonate (152SmC) salt within the porous structures of the microspheres. Both formulations were neutron-activated in a research reactor. Physicochemical characterization, gamma spectrometry, and radiolabel stability tests were carried out to study the performance and stability of the microspheres.

    RESULTS: The Sm- and SmC-labeled microspheres remained spherical and smooth, with a mean size of 35 µm before and after neutron activation. Fourier transform infrared (FTIR) spectroscopy indicated that the functional groups of the microspheres remained unaffected after neutron activation. The 153Sm- and 153SmC-labeled microspheres achieved activity of 2.53 ± 0.08 and 2.40 ± 0.13 GBq·g-1, respectively, immediate after 6 h neutron activation in the neutron flux of 2.0 × 1012 n·cm-2·s-1. Energy-dispersive X-ray (EDX) and gamma spectrometry showed that no elemental and radioactive impurities were present in the microspheres after neutron activation. The retention efficiency of 153Sm in the 153SmC-labeled microspheres was excellent (~99% in distilled water and saline; ~97% in human blood plasma), which was higher than the 153Sm-labeled microspheres (~95% and ~85%, respectively).

    CONCLUSION: 153SmC-labeled microspheres have demonstrated excellent properties for potential application as theranostic agents for hepatic radioembolization.

    Matched MeSH terms: Yttrium Radioisotopes
  4. Tang KS
    Curr Diabetes Rev, 2021;17(4):496-502.
    PMID: 33045978 DOI: 10.2174/1573399816999201012201111
    BACKGROUND: Diabetes mellitus is a metabolic disease that requires immediate attention. Oxidative stress that leads to the generation of reactive oxygen species is a contributing factor to the disease progression. Yttrium oxide nanoparticles (Y2O3 NPs) have a profound effect on alleviating oxidative damage.

    METHODS: The literature related to Y2O3 NPs and oxidative stress has been thoroughly searched using PubMed and Scopus databases and relevant studies from inception until August 2020 were included in this scoping review.

    RESULTS: Y2O3 NPs altered oxidative stress-related biochemical parameters in different disease models including diabetes.

    CONCLUSION: Although Y2O3 NPs are a promising antidiabetic agent due to their antioxidant and anti- inflammatory properties, more studies are required to further elucidate the pharmacological and toxicological properties of these nanoparticles.

    Matched MeSH terms: Yttrium
  5. Taufiq-Yap, Y. H., Ong, P. S., Zainal, Z.
    MyJurnal
    In this work, 10 mol% yttrium-doped ceria powders, Ce0.9Y0.1O1.95, were synthesised using a new mechanical technique, mechanochemical reaction, in which both impact action and shearing forces were applied for efficient fine grinding, subsequently leading to higher homogeneity of the resultant powders. Ce0.9Y0.1O1.95 prepared using this new technique was systematically compared with a sample of the same prepared using conventional solid-state methodology. X-ray diffraction analysis showed all prepared samples were single phase with a cubic fluorite structure. Generally, Y2O3-doped CeO2 electrolytes prepared by mechanochemical reactions were stable at a lower temperature (1100 °C) compared with a sample of the same synthesised using the conventional solid-state method. Characterisations using differential thermal analysis (DTA) and thermogravimetric analysis (TGA) showed no thermal changes and phase transitions, indicating all materials were thermally stable. The electrical properties of the samples investigated by AC impedance spectroscopy in the temperature range 200–800 ˚C are presented and discussed. Scanning electron microscopy (SEM) was used to study the morphology of the materials. Fine-grained powders with uniform grain-size distribution were obtained from the mechanochemical reaction.
    Matched MeSH terms: Yttrium
  6. Hasan M, Hanafiah MM, Alhilfy IHH, Aeyad Taha Z
    PeerJ, 2021;9:e10614.
    PMID: 33520446 DOI: 10.7717/peerj.10614
    Background: Laser applications in agriculture have recently gained much interest due to improved plant characteristics following laser treatment before the sowing of seeds. In this study, maize seeds were exposed to different levels of laser treatment prior to sowing to improve their field performance. The aim of this study is to evaluate the impact of pre-sowing laser photobiomodulation on the field emergence and growth of treated maize seeds.

    Methods: The maize seeds were first photobiomodulated with two lasers: 1) a helium-neon (He-Ne) red laser (632.8 nm), and 2) a neodymium-doped yttrium aluminum garnet (Nd:YAG) green laser (532 nm). Following three replications of randomized complete block design (RCBD), four irradiation treatments were applied (45 s, 65 s, 85 s, and 105 s) at two power intensities (2 mW/cm2 and 4 mW/cm2).

    Results: Based on the results, maize seeds pretreated with a green laser and 2 mW/cm2 power intensity for 105 s exhibited the highest rate of seed emergence (96%) compared to the untreated control seeds with a lower seed emergence rate (62.5%). Furthermore, maize seeds treated with a red laser for 45 s showed an increased vigor index compared to the other treatment options and the control (P 

    Matched MeSH terms: Yttrium
  7. Hashikin NA, Yeong CH, Abdullah BJ, Ng KH, Chung LY, Dahalan R, et al.
    PLoS One, 2015;10(9):e0138106.
    PMID: 26382059 DOI: 10.1371/journal.pone.0138106
    Samarium-153 (153Sm) styrene divinylbenzene microparticles were developed as a surrogate for Yttrium-90 (90Y) microspheres in liver radioembolization therapy. Unlike the pure beta emitter 90Y, 153Sm possess both therapeutic beta and diagnostic gamma radiations, making it possible for post-procedure imaging following therapy.
    Matched MeSH terms: Yttrium Radioisotopes/therapeutic use
  8. Baig MR, Tan KB, Nicholls JI
    J Prosthet Dent, 2010 Oct;104(4):216-27.
    PMID: 20875526 DOI: 10.1016/S0022-3913(10)60128-X
    The marginal fit of crowns is a concern for clinicians, and there is no conclusive evidence of any one margin configuration yielding better results than others in terms of marginal fit.
    Matched MeSH terms: Yttrium
  9. Chow PK, Poon DY, Khin MW, Singh H, Han HS, Goh AS, et al.
    PLoS One, 2014;9(3):e90909.
    PMID: 24614178 DOI: 10.1371/journal.pone.0090909
    The safety and tolerability of sequential radioembolization-sorafenib therapy is unknown. An open-label, single arm, investigator-initiated Phase II study (NCT0071279) was conducted at four Asia-Pacific centers to evaluate the safety and efficacy of sequential radioembolization-sorafenib in patients with hepatocellular carcinoma (HCC) not amenable to curative therapies.
    Matched MeSH terms: Yttrium Radioisotopes/therapeutic use
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links