METHODS: Data on demography, diabetes status, management and complications were collected via medical records, interview and laboratory assessments. HbA(1c) was analysed by a central laboratory prospectively.
RESULTS: Patient profile was similar in the 1998 (N = 21,838) and 2003 cohorts (N = 15,549): 95% were diagnosed as type 2 diabetes mellitus and were obese (BMI approximately 25 kg/m(2)). Glycaemic control was unsatisfactory in many patients (mean HbA(1c) approximately 8%; fasting glucose approximately 9 mmol/L). Lipids were well-controlled but hypertension was not. The incidence of neuropathy ( approximately 33%) and cataract ( approximately 27%) were high. The majority ( approximately 71%) of patients in both cohorts were treated with oral antidiabetic drug (OAD) monotherapy; approximately 24% were on insulin therapy. Approximately half of the 2003 cohort reported a healthy state of well-being. Quality of life did not appear to have suffered as a result of having diabetes. However, many patients were worried about hypoglycaemic risk (53.9%) or worsening of diabetes (45.8%) and insulin initiation (64.5%).
CONCLUSIONS: Although both cohorts were separate cross-sectional studies of diabetes management status in Asia, the results showed that the demography profile, glycaemic control and cardiovascular risk factors were remarkably similar in both cohorts 5 years after the first survey. More concerted efforts are needed to increase diabetes awareness and education.
METHODS: In this cross-sectional study, Type 2 diabetic patients who were on insulin therapy attending health clinics were randomly selected and interviewed using a validated questionnaire. Binary logistic regression analysis was applied.
RESULTS: Out of 304 respondents, only 11.5% of them brought their used sharps to be disposed at health care facilities. Previous advice on sharp disposal from health care providers, knowledge score, and duration of diabetes were significant contributing factors for sharp waste disposal at health care facilities: (Adj. OR 6.31; 95% CI: 2.63, 15.12; p < 0.001), (Adj. OR 1.05; 95% CI: 1.03, 1.08; p < 0.001), and (Adj. OR 2.51; 95% CI: 1.06, 5.93; p = 0.036), respectively.
CONCLUSION: Continuous education and a locally adapted safe sharp disposal option must be available to increase awareness and facilitate diabetic patients adopting proper sharp disposal behavior.
Methods: The Iraqi Anti-Diabetic Medication Adherence Scale (IADMAS) consists of eight items. The face and content validity of the IADMAS were established via an expert panel. For convergent validity, the IADMAS was compared with the Medication Adherence Questionnaire (MAQ). For concurrent validity, the IADMAS was compared with glycosylated hemoglobin. A total of 84 patients with types 2 diabetes were recruited from a diabetes center in Baghdad, Iraq. Test-retest reliability was measured by readministering the IADMAS to the same patients 4 weeks later.
Results: Only 80 patients completed the study (response rate: 95%). Reliability analysis of the IADMAS showed a Cronbach's alpha value of 0.712, whereas that of the MAQ was 0.649. All items in the IADMAS showed no significant difference in the test-retest analysis, indicating that the IADMAS has stable reliability. There was no difference in the psychometric properties of the IADMAS and the MAQ. The sensitivity and specificity of the IADMAS were higher than that of the MAQ (100% vs 87.5% and 33.9% vs 29.7%, respectively).
Conclusion: The IADMAS developed in this study is a reliable and valid instrument for assessing antidiabetic medication adherence among Iraqi patients.
METHODS: A cross-sectional investigation was conducted at General Penang Hospital, Malaysia. Demographic criteria and laboratory tests of patients were investigated. Controlled glycemia (CG) was recognized as glycated hemoglobin (HbA1c) ≤7% depending on American Diabetes Association guidelines 2018. Charlson Comorbidity Index (CCI) was used to estimate the confounding influence of co-morbidities and predict ES-10Y. Data was managed by IBM-SPSS 23.0.
RESULTS: A total of 400 cases categorized to (44.25%) patients with CG, and (55.75%) cases had uncontrolled glycemia (UCG). HbA1c mean in CG and UCG group was (6.8 ± 0.9 vs 9.5 ± 1.6, P-value: 0.001). Fasting blood glucose was (7 ± 2.3 vs. 9.9 ± 4.3, P-value: 0.001) in CG and UCG group. CCI was (3.38 ± 2.38 vs. 4.42 ± 2.70, P-value: 0.001) and, ES-10Y was (62% vs 46.2%, p-value: 0.001) in CG vs. UCG respectively. Spearman test indicates a negative correlation between CG and CCI (r: 0.19, p-value: 0.001). Logistic regression confirmed HbA1c as a significant predictor of CCI (r2: 0.036, P-value: 0.001). CG has a positive correlation with survival (r: 0.16, P-value: 0.001) and logistic regression of survival (r2: 0.26, P-value: 0.001).
CONCLUSIONS: More than one-half of the investigated persons had UCG. Controlled HbA1c was associated with lower co-morbidities and higher ES-10Y.
METHODS: This is a controlled, intervention based study. It was run on three phases: before, during, and after Ramadan on 262 type 2 diabetes patients. The intervention group (n = 140) received RFEP on medications doses & timing adjustment before and after Ramadan, while the control group (n = 122) received standard care.
RESULTS: The dose of insulin glargine was reduced from 42.51 ± 22.16 at the baseline to 40.11 ± 18.51-units during Ramadan (p = 0.002) in the intervention group while it remained the same in the control group before Ramadan and during Ramadan (38.51 ± 18.63 and 38.14 ± 18.46, P = 0.428, respectively). The hypoglycemia score was 14.2 ± (8.5) pre-Ramadan in the intervention and reduced to 6.36 ± 6.17 during Ramadan (p
PATIENT CONCERNS: A 61-year-old Asian female with underlying type 2 DM presented to our ED with body weakness, dyspnea, nausea, vomiting, and mild abdominal pain for the past 2 days. These symptoms were preceded by poor oral intake for 1 week due to severe toothache. Dapagliflozin was recently added to her antidiabetic drug regimen of metformin and glibenclamide 2 weeks ago.
DIAGNOSES: Arterial blood gases showed a picture of severe metabolic acidosis with an elevated anion gap, while ketones were elevated in blood and positive in urine. Blood glucose was mildly elevated at 180 mg/dL. Serum lactate levels were normal. Our patient was thus diagnosed with eDKA.
INTERVENTION: Our patient was promptly admitted to the intensive care unit and treated for eDKA through intravenous rehydration therapy with insulin infusion.
OUTCOMES: Serial blood gas analyses showed gradual resolution of the patient's ketoacidosis with normalized anion gap and clearance of serum ketones. She was discharged uneventfully on day 4, with permanent cessation of dapagliflozin administration.
LESSONS: Life-threatening eDKA as a complication of dapagliflozin is a challenging and easilymissed diagnosis in the ED. Such an ED presentation is very rare, nevertheless emergency physicians are reminded to consider the diagnosis of eDKA in a patient whose drug regimen includes any SGLT2 inhibitor, especially if the patient presents with nausea, vomiting, abdominal pain, dyspnea, lethargy, and is clinically dehydrated. These patients should then be investigated with ketone studies and blood gas analyses regardless of blood glucose levels for prompt diagnosis and treatment.
MATERIALS AND METHODS: Seventy-four participants, with type 1 (T1D, n = 24), type 2 (T2D, n = 11), or gestational (n = 39) diabetes, were enrolled across 13 sites (9 in United Kingdom, 4 in Austria). Average gestation was 26.6 ± 6.8 weeks (mean ± standard deviation), age was 30.5 ± 5.1 years, diabetes duration was 13.1 ± 7.3 years for T1D and 3.2 ± 2.5 years for T2D, and 49/74 (66.2%) used insulin to manage their diabetes. Sensors were worn for up to 14 days. Sensor glucose values (masked) were compared with capillary SMBG values (made at least 4 times/day).
RESULTS: Clinical accuracy of sensor results versus SMBG results was demonstrated, with 88.1% and 99.8% of results within Zone A and Zones A and B of the Consensus Error Grid, respectively. Overall mean absolute relative difference was 11.8%. Sensor accuracy was unaffected by the type of diabetes, the stage of pregnancy, whether insulin was used, age or body mass index. User questionnaires indicated high levels of satisfaction with sensor wear, system use, and comparison to SMBG. There were no unanticipated device-related adverse events.
CONCLUSIONS: Good agreement was demonstrated between the FreeStyle Libre System and SMBG. Accuracy of the system was unaffected by patient characteristics, indicating that the system is safe and accurate to use by pregnant women with diabetes.