Displaying publications 41 - 60 of 154 in total

Abstract:
Sort:
  1. Eshraghi A, Osman NA, Gholizadeh H, Ahmadian J, Rahmati B, Abas WA
    Sci Rep, 2013;3:2270.
    PMID: 23881340 DOI: 10.1038/srep02270
    Individuals with lower limb amputation need a secure suspension system for their prosthetic devices. A new coupling system was developed that is capable of suspending the prosthesis. The system's safety is ensured through an acoustic alarm system. This article explains how the system works and provides an in vivo evaluation of the device with regard to pistoning during walking. The system was designed to be used with silicone liners and is based on the requirements of prosthetic suspension systems. Mechanical testing was performed using a universal testing machine. The pistoning during walking was measured using a motion analysis system. The new coupling device produced significantly less pistoning compared to a common suspension system (pin/lock). The safety alarm system would buzz if the suspension was going to fail. The new coupling system could securely suspend the prostheses in transtibial amputees and produced less vertical movement than the pin/lock system.
  2. Abd Razak NA, Abu Osman NA, Gholizadeh H, Ali S
    Biomed Eng Online, 2014 Apr 23;13:49.
    PMID: 24755242 DOI: 10.1186/1475-925X-13-49
    BACKGROUND: The design and performance of a new development prosthesis system known as biomechatronics wrist prosthesis is presented in this paper. The prosthesis system was implemented by replacing the Bowden tension cable of body powered prosthesis system using two ultrasonic sensors, two servo motors and microcontroller inside the prosthesis hand for transradial user.

    METHODS: The system components and hand prototypes involve the anthropometry, CAD design and prototyping, biomechatronics engineering together with the prosthetics. The modeler construction of the system develop allows the ultrasonic sensors that are placed on the shoulder to generate the wrist movement of the prosthesis. The kinematics of wrist movement, which are the pronation/supination and flexion/extension were tested using the motion analysis and general motion of human hand were compared. The study also evaluated the require degree of detection for the input of the ultrasonic sensor to generate the wrist movements.

    RESULTS: The values collected by the vicon motion analysis for biomechatronics prosthesis system were reliable to do the common tasks in daily life. The degree of the head needed to bend to give the full input wave was about 45°-55° of rotation or about 14 cm-16 cm. The biomechatronics wrist prosthesis gave higher degree of rotation to do the daily tasks but did not achieve the maximum degree of rotation.

    CONCLUSION: The new development of using sensor and actuator in generating the wrist movements will be interesting for used list in medicine, robotics technology, rehabilitations, prosthetics and orthotics.

  3. El-Sayed AM, Abo-Ismail A, El-Melegy MT, Hamzaid NA, Osman NA
    Sensors (Basel), 2013 May 07;13(5):5826-40.
    PMID: 23653051 DOI: 10.3390/s130505826
    Piezoelectric bimorphs have been used as a micro-gripper in many applications, but the system might be complex and the response performance might not have been fully characterized. In this study the dynamic characteristics of bending piezoelectric bimorphs actuators were theoretically and experimentally investigated for micro-gripping applications in terms of deflection along the length, transient response, and frequency response with varying driving voltages and driving signals. In addition, the implementation of a parallel micro-gripper using bending piezoelectric bimorphs was presented. Both fingers were actuated separately to perform mini object handling. The bending piezoelectric bimorphs were fixed as cantilevers and individually driven using a high voltage amplifier and the bimorph deflection was measured using a non contact proximity sensor attached at the tip of one finger. The micro-gripper could perform precise micro-manipulation tasks and could handle objects down to 50 µm in size. This eliminates the need for external actuator extension of the microgripper as the grasping action was achieved directly with the piezoelectric bimorph, thus minimizing the weight and the complexity of the micro-gripper.
  4. Pirouzi G, Abu Osman NA, Oshkour AA, Ali S, Gholizadeh H, Abas WA
    Sensors (Basel), 2014;14(9):16754-65.
    PMID: 25207872 DOI: 10.3390/s140916754
    The suspension system and socket fitting of artificial limbs have major roles and vital effects on the comfort, mobility, and satisfaction of amputees. This paper introduces a new pneumatic suspension system that overcomes the drawbacks of current suspension systems in donning and doffing, change in volume during daily activities, and pressure distribution in the socket-stump interface. An air pneumatic suspension system (APSS) for total-contact sockets was designed and developed. Pistoning and pressure distribution in the socket-stump interface were tested for the new APSS. More than 95% of the area between each prosthetic socket and liner was measured using a Tekscan F-Scan pressure measurement which has developed matrix-based pressure sensing systems. The variance in pressure around the stump was 8.76 kPa. APSS exhibits less pressure concentration around the stump, improved pressure distribution, easy donning and doffing, adjustability to remain fitted to the socket during daily activities, and more adaptability to the changes in stump volume. The volume changes were adjusted by utility of air pressure sensor. The vertical displacement point and reliability of suspension were assessed using a photographic method. The optimum pressure in every level of loading weight was 55 kPa, and the maximum displacement was 6 mm when 90 N of weight was loaded.
  5. Osman NA, Abdul-Latiff MAB, Mohd-Ridwan AR, Yaakop S, Nor SM, Md-Zain BM
    Animals (Basel), 2020 Nov 26;10(12).
    PMID: 33255964 DOI: 10.3390/ani10122215
    Understanding dietary diversity is a fundamental task in the study of stump-tailed macaque, Macaca arctoides in its natural habitat. However, direct feeding observation and morphological identification using fecal samples are not effective and nearly impossible to obtain in natural habitats because this species is sensitive to human presence. As ecological methods are challenging and time-consuming, DNA metabarcoding offers a more powerful assessment of the diet. We used a chloroplast tRNL DNA metabarcoding approach to identify the diversity of plants consumed by free-ranging M. arctoides in the Malaysia-Thailand border region located in Perlis State Park, Peninsular Malaysia. DNA was extracted from three fecal samples, and chloroplast tRNL DNA was amplified and sequenced using the Illumina MiniSeq platform. Sequences were analyzed using the CLC Genomic Workbench software. A total of 145 plant species from 46 families were successfully identified as being consumed by M. arctoides. The most abundant species were yellow saraca, Saraca thaipingensis (11.70%), common fig, Ficus carica (9.33%), aramata, Clathrotropis brachypetala (5.90%), sea fig, Ficus superba (5.44%), and envireira, Malmea dielsiana (1.70%). However, Clathrotropis and Malmea are not considered Malaysian trees because of limited data available from Malaysian plant DNA. Our study is the first to identify plant taxa up to the species level consumed by stump-tailed macaques based on a DNA metabarcoding approach. This result provides an important understanding on diet of wild M. arctoides that only reside in Perlis State Park, Malaysia.
  6. Ngah AH, Kamalrulzaman NI, Mohamad MFH, Abdul Rashid R, Harun NO, Ariffin NA, et al.
    Qual Quant, 2022 Aug 10.
    PMID: 35971418 DOI: 10.1007/s11135-022-01465-y
    Without proper preparation by higher institutions, the COVID-19 pandemic has forced the world to rely on online learning. Even students of social science and science are looking for different knowledge and skills. Currently, both groups rely on the same method to gather knowledge for future undertakings. Given the uncertainty regarding the resolution of COVID-19, which has driven students to continue using online learning, the current study aims to identify the factors of willingness to continue online learning among social science and pure science students by extending the use of expectation-confirmation theory. Applying a purposive sampling method, 2,215 questionnaires were collected among undergraduate students from Universiti Malaysia Terengganu (UMT) using an online survey. Current study found that expectation and confirmation positively affect satisfaction. Attitude, satisfaction and readiness were found to have a positive relationship with willingness to continue online learning. Meanwhile, self-efficacy was found unsupported hypothesis for the direct effect. For multigroup analysis, readiness was found to have a significant difference between students of social science and pure science. The findings of this research enrich the literature about online learning, especially in the COVID-19 setting. Moreover, this work is useful for higher education institutions seeking to design a better strategy that allows students to return to campus.
  7. Moo EK, Abusara Z, Abu Osman NA, Pingguan-Murphy B, Herzog W
    J Biomech, 2013 Aug 9;46(12):2024-31.
    PMID: 23849134 DOI: 10.1016/j.jbiomech.2013.06.007
    Morphological studies of live connective tissue cells are imperative to helping understand cellular responses to mechanical stimuli. However, photobleaching is a constant problem to accurate and reliable live cell fluorescent imaging, and various image thresholding methods have been adopted to account for photobleaching effects. Previous studies showed that dual photon excitation (DPE) techniques are superior over conventional one photon excitation (OPE) confocal techniques in minimizing photobleaching. In this study, we investigated the effects of photobleaching resulting from OPE and DPE on morphology of in situ articular cartilage chondrocytes across repeat laser exposures. Additionally, we compared the effectiveness of three commonly-used image thresholding methods in accounting for photobleaching effects, with and without tissue loading through compression. In general, photobleaching leads to an apparent volume reduction for subsequent image scans. Performing seven consecutive scans of chondrocytes in unloaded cartilage, we found that the apparent cell volume loss caused by DPE microscopy is much smaller than that observed using OPE microscopy. Applying scan-specific image thresholds did not prevent the photobleaching-induced volume loss, and volume reductions were non-uniform over the seven repeat scans. During cartilage loading through compression, cell fluorescence increased and, depending on the thresholding method used, led to different volume changes. Therefore, different conclusions on cell volume changes may be drawn during tissue compression, depending on the image thresholding methods used. In conclusion, our findings confirm that photobleaching directly affects cell morphology measurements, and that DPE causes less photobleaching artifacts than OPE for uncompressed cells. When cells are compressed during tissue loading, a complicated interplay between photobleaching effects and compression-induced fluorescence increase may lead to interpretations in cell responses to mechanical stimuli that depend on the microscopic approach and the thresholding methods used and may result in contradictory interpretations.
  8. Mohd Safee MK, Abu Osman NA
    Occup Ther Int, 2021;2021:4357473.
    PMID: 34707468 DOI: 10.1155/2021/4357473
    Muscle fatigue is a decline in muscle maximum force during contraction and can influence the fall risk among people. This study is aimed at identifying the effect of fatigue on prospective fall risk in transfemoral amputees (TFA). Fourteen subjects were involved in this study with TFA (34.7 ± 8.1 yrs, n = 7) and normal subjects (31.1 ± 7.4 yrs, n = 7). Fatigue of lower limb muscles was induced with the fatigue protocol. Subjects were tested prefatigue and postfatigue using the standardized fall risk assessment. All results were calculated and compared between pre- and postfatigue to identify fatigue's effect on both groups of subjects. The results showed that the fall risk increased significantly during pre- and postfatigue for TFA (p = 0.018), while there were no significant differences in normal subjects (p = 0.149). Meanwhile, the fall risk between TFA and normal subjects for prefatigue (p = 0.082) and postfatigue (p = 0.084) also showed no significant differences. The percentage (%) of increased fall risk for TFA was 19.2% compared to normal subjects only 16.7%. However, 61.4% increased of % fall risk in TFA after fatigue by using the baseline of the normal subject as the normalized % of fall risk. The increasing fall risks for TFA after fatigue are three times higher than the potential fall risk in normal subjects. The result indicates that they need to perform more precautions while prolonging lower limb activities. These results showed the implications of fatigue that can increase the fall risk due to muscle fatigue from repetitive and prolonged activities. Therefore, rehabilitation programs can be done very safely and precisely so that therapists can pursue fitness without aggravating existing injuries.
  9. Eshraghi A, Maroufi N, Sanjari MA, Saeedi H, Keyhani MR, Gholizadeh H, et al.
    Prosthet Orthot Int, 2013 Feb;37(1):76-84.
    PMID: 22751219 DOI: 10.1177/0309364612448805
    Biomechanical factors, such as spinal deformities can result in balance control disorders.
  10. Maleki-Ghaleh H, Hafezi M, Hadipour M, Nadernezhad A, Aghaie E, Behnamian Y, et al.
    PLoS One, 2015;10(9):e0138454.
    PMID: 26383641 DOI: 10.1371/journal.pone.0138454
    In the current study, a sol-gel-synthesized tricalcium magnesium silicate powder was coated on Ti-6Al-4V alloys using plasma spray method. Composition of feed powder was evaluated by X-ray diffraction technique before and after the coating process. Scanning electron microscopy and atomic force microscopy were used to study the morphology of coated substrates. The corrosion behaviors of bare and coated Ti-6Al-4V alloys were examined using potentiodynamic polarization test and electrochemical impedance spectroscopy in stimulated body fluids. Moreover, bare and coated Ti-6Al-4V alloys were characterized in vitro by culturing osteoblast and mesenchymal stem cells for several days. Results demonstrated a meaningful improvement in the corrosion resistance of Ti-6Al-4V alloys coated with tricalcium magnesium silicate compared with the bare counterparts, by showing a decrease in corrosion current density from 1.84 μA/cm2 to 0.31 μA/cm2. Furthermore, the coating substantially improved the bioactivity of Ti-6Al-4Valloys. Our study on corrosion behavior and biological response of Ti-6Al-4V alloy coated by tricalcium magnesium silicate proved that the coating has considerably enhanced safety and applicability of Ti-6Al-4V alloys, suggesting its potential use in permanent implants and artificial joints.
  11. Khalaj N, Abu Osman NA, Mokhtar AH, Mehdikhani M, Wan Abas WA
    Proc Inst Mech Eng H, 2014 Feb;228(2):190-9.
    PMID: 24458100 DOI: 10.1177/0954411914521155
    The knee adduction moment represents the medial knee joint load, and greater value is associated with higher load. In people with knee osteoarthritis, it is important to apply proper treatment with the least side effects to reduce knee adduction moment and, consequently, reduce medial knee joint load. This reduction may slow the progression of knee osteoarthritis. The research team performed a literature search of electronic databases. The search keywords were as follows: knee osteoarthritis, knee adduction moment, exercise program, exercise therapy, gait retraining, gait modification and knee joint loading. In total, 12 studies were selected, according to the selection criteria. Findings from previous studies illustrated that exercise and gait retraining programs could alter knee adduction moment in people with knee osteoarthritis. These treatments are noninvasive and nonpharmacological which so far have no or few side effects, as well as being low cost. The results of this review revealed that gait retraining programs were helpful in reducing the knee adduction moment. In contrast, not all the exercise programs were beneficial in reducing knee adduction moment. Future studies are needed to indicate best clinical exercise and gait retraining programs, which are most effective in reducing knee adduction moment in people with knee osteoarthritis.
    Study design: systematic review
  12. Oshkour AA, Talebi H, Seyed Shirazi SF, Yau YH, Tarlochan F, Abu Osman NA
    Artif Organs, 2015 Feb;39(2):156-64.
    PMID: 24841371 DOI: 10.1111/aor.12315
    This study aimed to assess the performance of different longitudinal functionally graded femoral prostheses. This study was also designed to develop an appropriate prosthetic geometric design for longitudinal functionally graded materials. Three-dimensional models of the femur and prostheses were developed and analyzed. The elastic modulus of these prostheses in the sagittal plane was adjusted along a gradient direction from the distal end to the proximal end. Furthermore, these prostheses were composed of titanium alloy and hydroxyapatite. Results revealed that strain energy, interface stress, and developed stress in the femoral prosthesis and the bone were influenced by prosthetic geometry and gradient index. In all of the prostheses with different geometries, strain energy increased as gradient index increased. Interface stress and developed stress decreased. The minimum principal stress and the maximum principal stress of the bone slightly increased as gradient index increased. Hence, the combination of the femoral prosthetic geometry and functionally graded materials can be employed to decrease stress shielding. Such a combination can also be utilized to achieve equilibrium in terms of the stress applied on the implanted femur constituents; thus, the lifespan of total hip replacement can be prolonged.
  13. Khalaj N, Abu Osman NA, Mokhtar AH, George J, Abas WA
    ScientificWorldJournal, 2014;2014:815184.
    PMID: 25136689 DOI: 10.1155/2014/815184
    Knee osteoarthritis is a common cause of disability which influences the quality of life. It is associated with impaired knee joint proprioception, which affects postural stability. Postural stability is critical for mobility and physical activities. Different types of treatment including nonsurgical and surgical are used for knee osteoarthritis. Hyaluronic acid injection is a nonsurgical popular treatment used worldwide. The aim of this study was to demonstrate the effect of hyaluronic acid injections on postural stability in individuals with bilateral knee osteoarthritis. Fifty patients aged between 50 and 70 years with mild and moderate bilateral knee osteoarthritis participated in our study. They were categorized into treatment (n = 25) and control (n = 25) groups. The treatment group received five weekly hyaluronic acid injections for both knees, whereas the control group did not receive any treatment. Postural stability and fall risk were assessed using the Biodex Stability System and clinical "Timed Up and Go" test. All the participants completed the study. The treatment group showed significant decrease in postural stability and fall risk scores after five hyaluronic acid injections. In contrast, the control group showed significant increase. This study illustrated that five intra-articular hyaluronic acid injections could significantly improve postural stability and fall risk in bilateral knee osteoarthritis patients. This trial is registered with: NCT02063373.
  14. Farzadi A, Solati-Hashjin M, Asadi-Eydivand M, Abu Osman NA
    PLoS One, 2014;9(9):e108252.
    PMID: 25233468 DOI: 10.1371/journal.pone.0108252
    Powder-based inkjet 3D printing method is one of the most attractive solid free form techniques. It involves a sequential layering process through which 3D porous scaffolds can be directly produced from computer-generated models. 3D printed products' quality are controlled by the optimal build parameters. In this study, Calcium Sulfate based powders were used for porous scaffolds fabrication. The printed scaffolds of 0.8 mm pore size, with different layer thickness and printing orientation, were subjected to the depowdering step. The effects of four layer thicknesses and printing orientations, (parallel to X, Y and Z), on the physical and mechanical properties of printed scaffolds were investigated. It was observed that the compressive strength, toughness and Young's modulus of samples with 0.1125 and 0.125 mm layer thickness were more than others. Furthermore, the results of SEM and μCT analyses showed that samples with 0.1125 mm layer thickness printed in X direction have more dimensional accuracy and significantly close to CAD software based designs with predefined pore size, porosity and pore interconnectivity.
  15. Chan BT, Lim E, Ong CW, Abu Osman NA
    PMID: 23521137 DOI: 10.1080/10255842.2013.779683
    Despite the advancement of cardiac imaging technologies, these have traditionally been limited to global geometrical measurements. Computational fluid dynamics (CFD) has emerged as a reliable tool that provides flow field information and other variables essential for the assessment of the cardiac function. Extensive studies have shown that vortex formation and propagation during the filling phase acts as a promising indicator for the diagnosis of the cardiac health condition. Proper setting of the boundary conditions is crucial in a CFD study as they are important determinants, that affect the simulation results. In this article, the effect of different transmitral velocity profiles (parabolic and uniform profile) on the vortex formation patterns during diastole was studied in a ventricle with dilated cardiomyopathy (DCM). The resulting vortex evolution pattern using the uniform inlet velocity profile agreed with that reported in the literature, which revealed an increase in thrombus risk in a ventricle with DCM. However the application of a parabolic velocity profile at the inlet yields a deviated vortical flow pattern and overestimates the propagation velocity of the vortex ring towards the apex of the ventricle. This study highlighted that uniform inlet velocity profile should be applied in the study of the filling dynamics in a left ventricle because it produces results closer to that observed experimentally.
  16. Ting CY, Ahmad Zaidi Adruce S, Hassali MA, Ting H, Lim CJ, Ting RS, et al.
    Trials, 2018 Jun 05;19(1):310.
    PMID: 29871651 DOI: 10.1186/s13063-018-2649-9
    BACKGROUND: Amidst the high disease burden, non-adherence to medications among patients with type 2 diabetes mellitus (T2DM) has been reported to be common and devastating. Sarawak Pharmaceutical Services Division has formulated a pharmacist-led, multiple-theoretical-grounding, culturally sensitive and structured group-based program, namely "Know Your Medicine - Take if for Health" (MEDIHEALTH), to improve medication adherence among Malay patients with T2DM. However, to date, little is known about the effectiveness and sustainability of the Program.

    METHODS/DESIGN: This is a prospective, parallel-design, two-treatment-group randomized controlled trial to evaluate the effectiveness and sustainability of MEDIHEALTH in improving medication adherence. Malay patients who have underlying T2DM, who obtain medication therapy at Petra Jaya Health Clinic and Kota Samarahan Health Clinic, and who have a moderate to low adherence level (8-item Morisky Medication Adherence Scale, Malaysian specific, score <6) were randomly assigned to the treatment group (MEDIHEALTH) or the control group. The primary outcome of this study is medication adherence level at baseline and 1, 3, 6 and 12 months post-intervention. The secondary outcomes are attitude, subjective norms, perceived behavioural control, intention and knowledge related to medication adherence measured at baseline and 1, 6 and 12 months post-intervention. The effectiveness and sustainability of the Program will be triangulated by findings from semi-structured interviews with five selected participants conducted 1 month after the intervention and in-depth interviews with two main facilitators and two managerial officers in charge of the Program 12 months after the intervention. Statistical analyses of quantitative data were conducted using SPSS version 22 and Stata version 14. Thematic analysis for qualitative data were conducted with the assistance of ATLAS.ti 8.

    DISCUSSION: This study provides evidence on the effectiveness and sustainability of a structured group-based educational program that employs multiple theoretical grounding and a culturally sensitive approach in promoting medication adherence among Malays with underlying T2DM. Both the quantitative and qualitative findings of this study could assist in the future development of the Program.

    TRIAL REGISTRATION: National Medical Research Register, NMRR-17-925-35875 (IIR). Registered on 19 May 2017. ClinicalTrials.gov, NCT03228706 . Registered on 25 July 2017.

  17. Ting CY, Ahmad Zaidi Adruce S, Lim CJ, Abd Jabar AHA, Ting RS, Ting H, et al.
    Res Social Adm Pharm, 2021 02;17(2):344-355.
    PMID: 32327398 DOI: 10.1016/j.sapharm.2020.03.026
    BACKGROUND: A pharmacist-led structured group-based intervention (MEDIHEALTH) was formulated to improve medication adherence among Malay type 2 diabetes mellitus (T2DM) patients in the Malaysian state of Sarawak.

    OBJECTIVES: The objective of this study was to examine the effectiveness of MEDIHEALTH and its mechanism of impact for improving medication adherence and the glycated haemoglobin (HbA1c) level.

    METHODS: A two group and parallel randomised controlled trial with a twelve months follow-up period was conducted at two primary health clinics in Malaysia that were surrounded by Malay communities. Malay T2DM patients whose HbA1c was >7% and total score on the Self-Efficacy for Appropriate Medication Use Scale (SEAMS) was <26 were recruited and parallelly randomised to the MEDIHEALTH or usual care (control) groups. The extended theory of planned behaviour was employed to test the mechanism of impact. Repeated measure analysis of variance was used to assess the difference in the estimated marginal mean of the SEAMS scores and HbA1c level between the intervention and control groups at different times.

    RESULTS: A total of 142 participants were recruited and randomised; three from the intervention group and eight from the control group withdrew before receiving any treatment. Hence, 68 participants in the intervention group and 63 in the control group were included for analyses. The MEDIHEALTH group had a significantly greater increase in the SEAMS score compared to the control group (p 
  18. Khan SJ, Khan SS, Usman J, Mokhtar AH, Abu Osman NA
    Proc Inst Mech Eng H, 2018 Feb;232(2):163-171.
    PMID: 29283019 DOI: 10.1177/0954411917750409
    This study aims to investigate the effects of varying toe angles at different platform settings on Overall Stability Index of postural stability and fall risk using Biodex Balance System in healthy participants and medial knee osteoarthritis patients. Biodex Balance System was employed to measure postural stability and fall risk at different foot progression angles (ranging from -20° to 40°, with 10° increments) on 20 healthy (control group) and 20 knee osteoarthritis patients (osteoarthritis group) randomly (age: 59.50 ± 7.33 years and 61.50 ± 8.63 years; body mass: 69.95 ± 9.86 kg and 70.45 ± 8.80 kg). Platform settings used were (1) static, (2) postural stability dynamic level 8 (PS8), (3) fall risk levels 12 to 8 (FR12) and (4) fall risk levels 8 to 2 (FR8). Data from the tests were analysed using three-way mixed repeated measures analysis of variance. The participant group, platform settings and toe angles all had a significant main effect on balance ( p ≤ 0.02). Platform settings had a significant interaction effect with participant group F(3, 144) = 6.97, p 
  19. Ching HA, Choudhury D, Nine MJ, Abu Osman NA
    Sci Technol Adv Mater, 2014 Feb;15(1):014402.
    PMID: 27877638
    Coatings such as diamond-like carbon (DLC) and titanium nitride (TiN) are employed in joint implants due to their excellent tribological properties. Recently, graphite-like carbon (GLC) and tantalum (Ta) have been proven to have good potential as coating as they possess mechanical properties similar to bones-high hardness and high flexibility. The purpose of this systematic literature review is to summarize the coating techniques of these four materials in order to compare their mechanical properties and tribological outcomes. Eighteen studies published between January 2000 and February 2013 have met the inclusion criteria for this review. Details of their fabrication parameters, material and mechanical properties along with the tribological outcomes, such as friction and wear rate, were identified and are presented in a systematic way. Although experiment conditions varied, we conclude that Ta has the lowest wear rate compared to DLC, GLC and TiN because it has a lower wear rate with high contact pressure as well as higher hardness to elasticity ratio. However, a further tribology test is needed in an environment which replicates artificial joints to confirm the acceptability of these findings.
  20. Bakri NM, Ibrahim SF, Osman NA, Hasan N, Jaffar FH, Rahman ZA, et al.
    Saudi J Biol Sci, 2016 Jan;23(1):S50-5.
    PMID: 26858565 DOI: 10.1016/j.sjbs.2015.10.023
    Apoptosis is a programed cell death that is vital for tissue homeostasis. However, embryo apoptosis had been known to be related to embryo fragmentation which should be avoided in in vitro fertilization (IVF). The purpose of this study was to evaluate the relationship of embryo apoptosis with the grade of immature oocytes and cleavage stage of in vitro produced (IVP) cattle embryos. This study consisted of 345 oocytes collected through ovary slicing. Immature oocytes were graded as A, B and C. This grading was based on cumulus cell thickness and compactness. All oocytes then underwent an in vitro maturation (IVM) procedure. An IVF was done 24 h after IVM culture. Prior to staining, stage of cleaved embryos was determined and classified as either 2, 4, 8 or >8-cell embryo stage. Apoptosis status of cleaved IVP embryos was determined by using annexin V-FITC staining technique at 48 and 72 h post insemination (hpi). Apoptosis status for each embryo was classified as either early or late. The result showed that there was no significant difference (p > 0.05) of apoptosis status among grade A, B and C embryos. All grades of oocytes showed embryo apoptosis where 1.5% late apoptosis for grade A, 4.5% and 10.4% of early and late apoptosis for grade B and grade C. Early apoptosis was not seen in grade A embryo. We also noted no significant difference (p > 0.05) of apoptosis status between 2, 4, 8 and >8-cell embryo stage. Early apoptosis was also not seen in >8-cell stage. Even though there were no differences in apoptosis expression between the three classes, the cleavage rate of grade A oocytes was significantly higher (p 