METHODS: A total of 15 femora were examined with four parameters i.e. maximum length of femur (FeMl), diameter of femoral head (FeHd), transverse diameter of midshaft (FeMd) and condylar breadth (FeCb). Osteometric board and vernier calipers were employed for the conventional method, while CT reconstructed images and Osirix MD software was utilised for the virtual method.
RESULTS: Results exhibited that there were no significant differences in the measurements by conventional and virtual methods. There were also no significant differences in the measurements by the intra or inter-observer error analyses. The intraclass correlation coefficients (ICC) were more than 0.95 by both intra and inter-observer error analyses. Technical error of measurement had displayed values within the acceptable ranges (rTEM <0.08 for intra-observer, <2.25 for inter-observer), and coefficient of reliability (R) indicated small measurement errors (R > 0.95 for intra-observer, R > 0.92 for inter-observer). By parameters, FeMl showed the highest R value (0.99) with the least error in different methods and observers (rTEM = 0.02-0.41%). Bland and Altman plots revealed points scattered close to zero indicating perfect agreement by both virtual and conventional methods. The mean differences for FeMl, FeHd, FeMd and FeCb measurements were 0.01 cm, -0.01 cm, 0.02 cm and 0.01 cm, respectively.
CONCLUSION: This brought to suggest that bone measurement by virtual method was highly accurate and reliable as in the conventional method. It is recommended for implementation in the future anthropological studies especially in countries with limited skeletal collection.
KEY WORDS: Femur nonunion, interlocking nail, symptoms before breakage of nail.
Material and Methods: We reviewed a series of eight cases with standard and modified techniques of plating after lengthening. The amount of lengthening, the period of distraction, the external fixator index and the associated complications were assessed.
Results: The mean lengthening was 5cm, with a range of 3cm to 9cm. The external fixation index, the period of external fixators in days in relation to the length of distraction in cm, was between 18 days/cm to 58 days/cm. One patient with quadriceps contracture, underwent quadriceplasty to improve knee flexion. Three patients with transient knee stiffness had resolution with aggressive physiotherapy. One patient with transient hypoesthesia recovered spontaneously. None of the patients developed joint subluxation, deep infection, re-fracture or implant failures.
Conclusion: Standard and modified techniques of plating after lengthening were safe and required only a short period of external fixation. The modified technique offered an easier way of plate insertion in a deformed bone.