Displaying publications 41 - 55 of 55 in total

Abstract:
Sort:
  1. Maidur SR, Patil PS, Katturi NK, Soma VR, Ai Wong Q, Quah CK
    J Phys Chem B, 2021 Apr 22;125(15):3883-3898.
    PMID: 33830758 DOI: 10.1021/acs.jpcb.1c01243
    The structural, thermal, linear, and femtosecond third-order nonlinear optical (NLO) properties of two pyridine-based anthracene chalcones, (2E)-1-(anthracen-9-yl)-3-(pyridin-2-yl)prop-2-en-1-one (2PANC) and (2E)-1-(anthracen-9-yl)-3-(pyridin-3-yl)prop-2-en-1-one (3PANC), were investigated. These two chalcones were synthesized following the Claisen-Schmidt condensation method. Optically transparent single crystals were achieved using a slow evaporation solution growth technique. The presence of functional groups in these molecules was established by Fourier transform infrared and NMR spectroscopic data. The detailed solid-state structure of both chalcones was determined from the single-crystal X-ray diffraction data. Both crystals crystallized in the centrosymmetric triclinic space group P1̅ with the nuance of unit cell parameters. The crystals (labeled as 2PANC and 3PANC) have been found to be transparent optically [in the entire visible spectral region] and were found to be thermally stable up to 169 and 194 °C, respectively. The intermolecular interactions were investigated using the Hirshfeld surface analysis, and the band structures (highest occupied molecular orbital-lowest unoccupied molecular orbital, excited-state energies, global chemical reactivity descriptors, and molecular electrostatic potentials) were studied using density functional theory (DFT) techniques. The ultrafast third-order NLO properties were investigated using (a) Z-scan and (b) degenerate four-wave mixing (DFWM) techniques using ∼50 fs pulses at 800 nm (1 kHz, ∼4 mJ) from a Ti:sapphire laser amplifier. Two-photon-assisted reverse saturable absorption, self-focusing nonlinear refraction, optical limiting, and optical switching behaviors were witnessed from the Z-scan data. 3PANC demonstrated a stronger two-photon absorption coefficient, while 2PANC depicted a stronger nonlinear refractive index among the two. The time-resolved DFWM data demonstrated that the decay times of 2PANC and 3PANC were ∼162 and ∼180 fs, respectively. The second hyperpolarizability (γ) values determined by DFT, Z-scan, and DFWM were found to be in good correlation (with a magnitude of ∼10-34 esu). The ultrafast third-order NLO response, significant NLO properties, and thermal stability of these chalcones brands them as potential candidates for optical power limiting and switching applications.
    Matched MeSH terms: Refractometry
  2. Ahmad Tarmizi AH, Kuntom A
    PMID: 33397128 DOI: 10.1080/10408398.2020.1865264
    3-monochloropropane-1,2-diol esters (3-MCPDE) and glycidyl esters (GE) are processed-developed contaminants presence in vegetable oils after undergo refining process under excessive heat. Refined oils are extensively used in various frying applications, nevertheless, the reservation against their quality and safety aspects are of major concern to consumers and food industry. Realizing the importance to address these issues, this article deliberates an overview of published studies on the manifestation of 3-MCPDE and GE when vegetable oils undergo for frying process. With the modest number of published frying research associated to 3-MCPDE and GE, we confined our review from the perspectives of frying conditions, product properties, antioxidants and additives, pre-frying treatments and frying oil management. Simplicity of the frying process is often denied by the complexity of reactions occurred between oil and food which led to the development of unwanted contaminants. The behavior of 3-MCPDE and GE is closely related to physico-chemical characteristics of oils during frying. As such, relationships between 3-MCPDE and/or GE with frying quality indices - i.e. acidity in term of free fatty acid or acid value); secondary oxidation in term of p-anisidine value, total polar compounds and its fractions, and refractive index - were also discussed when oils were subjected under intermittent and continuous frying conditions.
    Matched MeSH terms: Refractometry
  3. Chaudhry AR, Irfan A, Muhammad S, Al-Sehemi AG, Ahmed R, Jingping Z
    J Mol Graph Model, 2017 08;75:355-364.
    PMID: 28651184 DOI: 10.1016/j.jmgm.2017.05.012
    In the present study, we use the state of art density functional theory (DFT) techniques to calculate the structural, optoelectronic and nonlinear optical (NLO) properties for two novel chalcone derivatives. The geometrical structures of chalcone derivatives compound 1 and 2 are optimized using periodic boundary conditions (PBC) in solid-state phase as well as isolated single molecular geometry in the gas phase. The reasonable agreement is found among experimental, solid-state and gas phase single molecular geometries, which provide us, further confidence to explore the potential of above-entitled derivatives as good functional materials for electro-optical applications. For instance, the frequency dependent real parts of dielectric functions are calculated for compound 1 and 2. The maximum value of real part of the dielectric function for compound 1 and 2 at 0eV are computed as 4.35 and 6.68 for the polarization vectors of (001) directions, respectively, which reveals the fact that the compound 1 and 2 might be good charge transport materials. The reflectivities of the compound 1 and 2 are 0.64 and 0.45 revealing that the compound 2 might be more efficient material for organic photovoltaic (OPV) applications. The results of the refractive index improved by doping the strong electron withdrawing groups (EWGs) shows that the compound 2 might be good refractor of the photon as compared to compound 1. The calculated values for static second-order polarizability are 3498 and 10464 a. u. and for frequency dependent second harmonic generations are 2557 and 6429 a. u. for compound 1 and 2, respectively, which indicates their significant potential for possible nonlinear optical applications.
    Matched MeSH terms: Refractometry
  4. Sharifah Azizah, T.N., Nik Shanita, S., Hasnah, H.
    MyJurnal
    The aim of this study was to determine the specific content and type of sugars in selected commercial and traditional kuih in Klang Valley. The selection of the kuih was based on the validated Food Frequency Questionnaire (FFQ) for sugar. The selected commercial kuih was doughnut coated with sugar (Big Apple) while the ten traditional kuih samples consisted of kuih bingka ubi, kuih kasui, kuih keria, kuih koci, kuih lapis, kuih lopes, kuih onde-onde, kuih sagu, kuih seri muka and kuih talam. The doughnut coated with sugar (Big Apple) was purchased from Big Apple Donuts and Coffee franchise at two different locations, while the traditional kuih were randomly bought from stalls, cafeterias and restaurants around Kuala Lumpur and Rawang. The types and amount of sugar were determined using High Performance High Chromatography (HPLC) with a refractive index (RI) detector. Results showed that doughnut coated with sugar (Big Apple) has the highest starch content (22.6±0.3 g/100g) and kuih keria contained the highest available carbohydrate (41.5±1.7 g/100g), comprising of 24.2±2.4 g/100g total sugar and 17.3±0.7 g/100g of starch. The least available carbohydrate content was found in kuih talam (20.0±0.5 g/100g), which was 50% lower than the one in kuih keria. Major individual sugars detected in all kuih samples were consisted of sucrose (60.0%), glucose (16.2%), fructose (14.0%), maltose (9.5%) and lactose (0.3%). Majority of the kuih samples (90.9%) in this study can be categorized as medium sugar while only kuih keria was categorized as high sugar. Based on the two main ingredients (sugar and flour) used in the preparation of kuih, results showed that all kuih samples can be categorized as medium sugarmedium starch. In conclusion, this study served as a guideline by locals in selecting kuih of
    different sugar levels.
    Matched MeSH terms: Refractometry
  5. Abbas Ali, Hadi Mesran, M., Nik Mahmood, N.A., Abd Latip, R.
    MyJurnal
    In the present work, the influence of microwave power and heating times on the quality
    degradation of corn oil was evaluated. Microwave heating test was carried out using a domestic
    microwave oven for different periods at low- and medium-power settings for the corn oil sample.
    The changes in physicochemical characteristics related to oil degradation of the samples during
    heating were determined by standard methods. In this study, refractive index, free fatty acid
    content, peroxide value, p-anisidine value, TOTOX value, viscosity and total polar compound
    of the oils all increased with increasing heating power and time of exposure. In GLC analysis,
    the percentage of linoleic acid tended to decrease, whereas the percentage of palmitic, stearic
    and oleic acids increased. The C18:2/C16:0 ratio decreased in all oil samples with increasing
    heating times. Exposing the corn oil to various microwave power settings and heating periods
    caused the formation of hydroperoxides and secondary oxidation products. The heating reduced
    the various tocopherol isomers in corn oil and highest reduction was detected in γ-tocopherol.
    Longer microwave heating times resulted in a greater degree of oil deterioration. Microwave
    heating caused the formation of comparatively lower amounts of some degradative products in
    the oil samples heated at low-power setting compared to medium-power setting. The present
    analysis indicated that oil quality was affected by both microwave power and heating time.
    Matched MeSH terms: Refractometry
  6. Alade IO, Bagudu A, Oyehan TA, Rahman MAA, Saleh TA, Olatunji SO
    Comput Methods Programs Biomed, 2018 Sep;163:135-142.
    PMID: 30119848 DOI: 10.1016/j.cmpb.2018.05.029
    BACKGROUND AND OBJECTIVES: The refractive index of hemoglobin plays important role in hematology due to its strong correlation with the pathophysiology of different diseases. Measurement of the real part of the refractive index remains a challenge due to strong absorption of the hemoglobin especially at relevant high physiological concentrations. So far, only a few studies on direct measurement of refractive index have been reported and there are no firm agreements on the reported values of refractive index of hemoglobin due to measurement artifacts. In addition, it is time consuming, laborious and expensive to perform several experiments to obtain the refractive index of hemoglobin. In this work, we proposed a very rapid and accurate computational intelligent approach using Genetic Algorithm/Support Vector Regression models to estimate the real part of the refractive index for oxygenated and deoxygenated hemoglobin samples.

    METHODS: These models utilized experimental data of wavelengths and hemoglobin concentrations in building highly accurate Genetic Algorithm/Support Vector Regression model (GA-SVR).

    RESULTS: The developed methodology showed high accuracy as indicated by the low root mean square error values of 4.65 × 10-4 and 4.62 × 10-4 for oxygenated and deoxygenated hemoglobin, respectively. In addition, the models exhibited 99.85 and 99.84% correlation coefficients (r) for the oxygenated and deoxygenated hemoglobin, thus, validating the strong agreement between the predicted and the experimental results CONCLUSIONS: Due to the accuracy and relative simplicity of the proposed models, we envisage that these models would serve as important references for future studies on optical properties of blood.

    Matched MeSH terms: Refractometry
  7. Amiri IS, Azzuhri SRB, Jalil MA, Hairi HM, Ali J, Bunruangses M, et al.
    Micromachines (Basel), 2018 Sep 11;9(9).
    PMID: 30424385 DOI: 10.3390/mi9090452
    Light has found applications in data transmission, such as optical fibers and waveguides and in optoelectronics. It consists of a series of electromagnetic waves, with particle behavior. Photonics involves the proper use of light as a tool for the benefit of humans. It is derived from the root word "photon", which connotes the tiniest entity of light analogous to an electron in electricity. Photonics have a broad range of scientific and technological applications that are practically limitless and include medical diagnostics, organic synthesis, communications, as well as fusion energy. This will enhance the quality of life in many areas such as communications and information technology, advanced manufacturing, defense, health, medicine, and energy. The signal transmission methods used in wireless photonic systems are digital baseband and RoF (Radio-over-Fiber) optical communication. Microwave photonics is considered to be one of the emerging research fields. The mid infrared (mid-IR) spectroscopy offers a principal means for biological structure analysis as well as nonintrusive measurements. There is a lower loss in the propagations involving waveguides. Waveguides have simple structures and are cost-efficient in comparison with optical fibers. These are important components due to their compactness, low profile, and many advantages over conventional metallic waveguides. Among the waveguides, optofluidic waveguides have been found to provide a very powerful foundation for building optofluidic sensors. These can be used to fabricate the biosensors based on fluorescence. In an optical fiber, the evanescent field excitation is employed to sense the environmental refractive index changes. Optical fibers as waveguides can be used as sensors to measure strain, temperature, pressure, displacements, vibrations, and other quantities by modifying a fiber. For some application areas, however, fiber-optic sensors are increasingly recognized as a technology with very interesting possibilities. In this review, we present the most common and recent applications of the optical fiber-based sensors. These kinds of sensors can be fabricated by a modification of the waveguide structures to enhance the evanescent field; therefore, direct interactions of the measurand with electromagnetic waves can be performed. In this research, the most recent applications of photonics components are studied and discussed.
    Matched MeSH terms: Refractometry
  8. Abbas Ali M, Bamalli Nouruddeen Z, Ida I. Muhamad, Abd Latip R, Hidayu Othman N
    Sains Malaysiana, 2014;43:1189-1195.
    The aim of this study was to evaluate on how heat treatments by microwave oven may affect the oxidative degradation of sunflower oil (SFO) and its blend with palm olein (Po). The blend was prepared in the volume ratio of 40:60 (Po: SFO, PSF). The samples were exposed to microwave heating at medium power setting, for different periods. In this study, refractive index, free fatty acid content, peroxide value, p-anisidine value, total oxidation (Tomx), specific extinction, viscosity, polymer content, polar compounds and food oil sensor value of the oils all increased, whereas iodine value and C 18:21C16:0 ratio decreased as microwave heating progressed. Microwave heating temperature increased with increasing heating time and longer heating times resulted in a greater degree of oil deterioration. The percentage of linoleic acid tended to decrease, whereas the percentage of palmitic acid increased. The effect of adding PO to SFO on the formation of free fatty acids and conjugated dienes during microwave treatment was not significant (p< 0.05). No significant differences in food oil sensor value was observed between SFO and PSF. Based on the most oxidative stability criteria, it can be concluded that the microwave heating caused the formation of comparatively lower amounts of oxidation products in PSF compared to SFO, indicating a lower extent of oxidative degradation of PSF.
    Matched MeSH terms: Refractometry
  9. Ahmad H, Thambiratnam K, Zulkifli AZ, Lawrence A, Jasim AA, Kunasekaran W, et al.
    Sensors (Basel), 2013 Sep 30;13(10):13276-88.
    PMID: 24084118 DOI: 10.3390/s131013276
    An efficient and low cost optical method for directly measuring the concentration of homogenous biological solutes is proposed and demonstrated. The proposed system operates by Fresnel reflection, with a flat-cleaved single-mode fiber serving as the sensor probe. A laser provides a 12.9 dBm sensor signal at 1,550 nm, while a computer-controlled optical power meter measures the power of the signal returned by the probe. Three different mesenchymal stem cell (MSC) lines were obtained, sub-cultured and trypsinized daily over 9 days. Counts were measured using a haemocytometer and the conditioned media (CM) was collected daily and stored at -80 °C. MSCs release excretory biomolecules proportional to their growth rate into the CM, which changes the refractive index of the latter. The sensor is capable of detecting changes in the number of stem cells via correlation to the change in the refractive index of the CM, with the measured power loss decreasing approximately 0.4 dB in the CM sample per average 1,000 cells in the MSC subculture. The proposed system is highly cost-effective, simple to deploy, operate, and maintain, is non-destructive, and allows reliable real-time measurement of various stem cell proliferation parameters.
    Matched MeSH terms: Refractometry/instrumentation*
  10. Al-Fakih EA, Osman NA, Eshraghi A, Adikan FR
    Sensors (Basel), 2013 Aug 12;13(8):10348-57.
    PMID: 23941909 DOI: 10.3390/s130810348
    This study presents the first investigation into the capability of fiber Bragg grating (FBG) sensors to measure interface pressure between the stump and the prosthetic sockets of a trans-tibial amputee. FBG element(s) were recoated with and embedded in a thin layer of epoxy material to form a sensing pad, which was in turn embedded in a silicone polymer material to form a pressure sensor. The sensor was tested in real time by inserting a heavy-duty balloon into the socket and inflating it by using an air compressor. This test was conducted to examine the sensitivity and repeatability of the sensor when subjected to pressure from the stump of the trans-tibial amputee and to mimic the actual environment of the amputee's Patellar Tendon (PT) bar. The sensor exhibited a sensitivity of 127 pm/N and a maximum FSO hysteresis of around ~0.09 in real-time operation. Very good reliability was achieved when the sensor was utilized for in situ measurements. This study may lead to smart FBG-based amputee stump/socket structures for pressure monitoring in amputee socket systems, which will result in better-designed prosthetic sockets that ensure improved patient satisfaction.
    Matched MeSH terms: Refractometry/instrumentation*
  11. Fam HB, Lim KL
    J Cataract Refract Surg, 2006 Aug;32(8):1281-7.
    PMID: 16863962 DOI: 10.1016/j.jcrs.2006.02.060
    PURPOSE: To determine an index that distinguishes keratoconus and keratoconus-suspect eyes from normal eyes with Orbscan (Bausch & Lomb) corneal elevation maps.
    SETTING: Department of Ophthalmology, Tan Tock Seng Hospital, Singapore, and iLaser Centre, Island Hospital, Penang, Malaysia.
    METHODS: In this initial phase of this multicenter nonrandomized retrospective study, 1 eye of 166 normal subjects, 15 keratoconus patients, and 11 keratoconus suspects was examined at 1 clinic. The anterior best-fit sphere (BFS), posterior BFS, anterior elevation, posterior elevation, and maximum and minimum keratometries were analyzed. Two indices with the highest sensitivity and specificity classifying these conditions were identified using receiver operating characteristic curves. These 2 indices were evaluated in a subsequent validation study using 1 eye of 221 normal subjects, 43 keratoconus patients, and 23 keratoconus suspects from another clinic.
    RESULTS: The anterior elevation and anterior elevation ratio (anterior elevation ratio = anterior elevation/anterior BFS) best classified the different groups. An anterior elevation ratio of 0.5122 mm or less had 99% sensitivity and 95.2% specificity while a ratio 16.5 mum or less had 80.1% sensitivity and 80.8% specificity in discriminating normal eyes from keratoconus and keratoconus suspects. The results were similar in the validation study. In addition, these anterior elevation and anterior elevation ratio cutoff values had high sensitivity and specificity in identifying keratoconus suspects from normal eyes in the validation study.
    CONCLUSION: Anterior corneal elevation parameters are clinically relevant measures for detecting keratoconus and suspected keratoconus eyes.
    Matched MeSH terms: Refractometry
  12. Ali, M.A., Daud, A.S.M., Latip, R.A., Othman, N.H., Islam, M.A.
    MyJurnal
    The aim of the present study was to evaluate the effect of chicken nuggets addition on the degradation of canola oil during frying compared to the changes occurring when the same frying medium was simply heated at frying temperature as control. Heating or frying test was carried out at 185±5oC using electric fryer for 8 h/day for 3 consecutive days and the oil sample was collected every 4 h. The changes in fatty acids composition and physicochemical properties of the oil samples during frying and controlled heating experiments were monitored. In this study, refractive index, free fatty acid content, peroxide value, p-anisidine value, polar compounds and viscosity of the oils all increased, whereas iodine value and C18:2/C16:0 ratio decreased as heating or frying progressed. The percentage of linoleic acid tended to decrease, whereas the percentages of palmitic acid increased. Gas chromatography analysis revealed that adding chicken nuggets to heated canola oil led to higher decrease in the ratio of C18.2/C16:0 compared to what was measured when the fat alone was heated at frying temperature. The presence of chicken nuggets accelerates the formation of polymerization products and polar compounds in canola oil during frying.
    Matched MeSH terms: Refractometry
  13. Sadrolhosseini AR, Noor AS, Bahrami A, Lim HN, Talib ZA, Mahdi MA
    PLoS One, 2014;9(4):e93962.
    PMID: 24733263 DOI: 10.1371/journal.pone.0093962
    Polypyrrole multi-walled carbon nanotube composite layers were used to modify the gold layer to measure heavy metal ions using the surface plasmon resonance technique. The new sensor was fabricated to detect trace amounts of mercury (Hg), lead (Pb), and iron (Fe) ions. In the present research, the sensitivity of a polypyrrole multi-walled carbon nanotube composite layer and a polypyrrole layer were compared. The application of polypyrrole multi-walled carbon nanotubes enhanced the sensitivity and accuracy of the sensor for detecting ions in an aqueous solution due to the binding of mercury, lead, and iron ions to the sensing layer. The Hg ion bonded to the sensing layer more strongly than did the Pb and Fe ions. The limitation of the sensor was calculated to be about 0.1 ppm, which produced an angle shift in the region of 0.3° to 0.6°.
    Matched MeSH terms: Refractometry
  14. Menon PS, Said FA, Mei GS, Berhanuddin DD, Umar AA, Shaari S, et al.
    PLoS One, 2018;13(7):e0201228.
    PMID: 30052647 DOI: 10.1371/journal.pone.0201228
    This work investigates the surface plasmon resonance (SPR) response of 50-nm thick nano-laminated gold film using Kretschmann-based biosensing for detection of urea and creatinine in solution of various concentrations (non-enzymatic samples). Comparison was made with the presence of urease and creatininase enzymes in the urea and creatinine solutions (enzymatic samples), respectively. Angular interrogation technique was applied using optical wavelengths of 670 nm and 785 nm. The biosensor detects the presence of urea and creatinine at concentrations ranging from 50-800 mM for urea samples and 10-200 mM for creatinine samples. The purpose of studying the enzymatic sample was mainly to enhance the sensitivity of the sensor towards urea and creatinine in the samples. Upon exposure to 670 nm optical wavelength, the sensitivity of 1.4°/M was detected in non-enzymatic urea samples and 4°/M in non-enzymatic creatinine samples. On the other hand, sensor sensitivity as high as 16.2°/M in urea-urease samples and 10°/M in creatinine-creatininase samples was detected. The enhanced sensitivity possibly attributed to the increase in refractive index of analyte sensing layer due to urea-urease and creatinine-creatininase coupling activity. This work has successfully proved the design and demonstrated a proof-of-concept experiment using a low-cost and easy fabrication of Kretschmann based nano-laminated gold film SPR biosensor for detection of urea and creatinine using urease and creatininase enzymes.
    Matched MeSH terms: Refractometry
  15. Keck CM
    Int J Pharm, 2010 May 5;390(1):3-12.
    PMID: 19733647 DOI: 10.1016/j.ijpharm.2009.08.042
    The influence of optical parameters, additional techniques (e.g. PIDS technology) and the importance of light microscopy were investigated by comparing laser diffraction data obtained via the conventional method and an optimized analysis method. Also the influence of a possible dissolution of nanocrystals during a measurement on the size result obtained was assessed in this study. The results reveal that dissolution occurs if unsaturated medium or microparticle saturated medium is used for the measurements. The dissolution is erratic and the results are not reproducible. Dissolution can be overcome by saturating the measuring medium prior to the measurement. If nanocrystals are analysed the dispersion medium should be saturated with the nanocrystals, because the solubility is higher than for coarse micro-sized drug material. The importance of using the optimized analysis method was proven by analysing 40 different nanosuspensions via the conventional versus the optimized sizing method. There was no large difference in the results obtained for the 40 nanosuspensions using the conventional method. This would have led to the conclusion, that all the 40 formulations investigated are physically stable. However, the analysis via the optimized method revealed that from 40 formulations investigated only four were physically stable. In conclusion an optimized analysis saves time and money and avoids misleading developments, because discrimination between "stable" and "unstable" can be done reliably at a very early stage of the development.
    Matched MeSH terms: Refractometry
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links