Displaying publications 661 - 680 of 5563 in total

Abstract:
Sort:
  1. Manohar, A., Azhar, M.Z.
    MyJurnal
    We report a case of factitious dermatitis in a 17 year female student who presented with recurrent pain .swelling and subcutaneous crepitations of the forearm. A thorough investigation was done. Full blood count, erythrocyte sedimentation rate was normal. Plain radiographs revealed the presence of subcutaneous emphysema. MRI showed similar findings and revealed normal muscles. Colonoscopy and OGDS were normal. except for a small polyp at the gastro-esophageal junction. Based on the clinical findings and lack of correlation with the investigations a diagnosis of factitious subcutaneous emphysema was made.
    Matched MeSH terms: Blood Cell Count; Blood Sedimentation
  2. Sabariah, M.N., Leong, C.F., Cheong, S.K.
    MyJurnal
    Peripheral blood (PB) CD34+ cells enumeration is currently the most reliable method to guide the timing of stem cell harvest. However, its usage is restricted by being technically challenging, costly, and time-consuming. Immature reticulocyte fraction (IRF) determination, which is simpler and cheaper and has a faster turn-around time, has been proposed for a similar purpose. The purpose of this study is to evaluate the value of IRF in guiding stem cell harvest and examine the correlation between IRF and PB CD34+ cells count. Daily pre-harvest tests, i.e. PB CD34+ cells and IRF from 21 patients scheduled for autologous PBSC transplant were assessed. Stem cells harvests were commenced when the PB CD34+ cell count were more than 10 cell/ul. A total of 205 pre-harvest tests were analysed. Following stem cell mobilisations, both the IRF and PB CD 34+ cell counts rose with a variable pattern. In this study, we observed that the IRF peaks preceded the PB CD34+ count by 2 days. On the day of stem cell harvest, all the peak IRF values were >0.3. The PB CD34+ cell counts correlated with the harvested stem cell yield, whereby r2 = 0.77, p < 0.021. In autologous stem cell mobilisation, we believe that IRF is a useful screening tool to predict the rise of the PB CD34+ cell counts as it is a simple, fast and less costly. An IRF of > 0.3 may be used as a cut-off value for the initiation of PB CD34+ quantification prior to stem cell harvest.
    Matched MeSH terms: Blood Cell Count; Blood Cells
  3. Hawkins BR
    Singapore Med J, 1974 Jun;15(2):128-31.
    PMID: 4416484
    The chance of excluding from paternity a falsely accused Chinese man and a falsely accused Malay man by using a number of blood genetic marker systems have been calculated using the ABO, Rhesus and MNSs systems, the combined chances are. 46.4% for a Chinese and 50.2% for a MaIay. When serum protein and red cell enzyme systems are included, the chances increase to approximately 76%. The chances may be increased by testing for haemoglobin variants, by red cell typing for the Diego (Di^a)
    antigen, and by testing for phenotypes other than Gm(a) in the Gm system. The Kell system may in some circumstances provide evidence in favour of paternity.
    Matched MeSH terms: Blood Group Antigens*
  4. Dissanaike AS, Ong HT, Kan SP
    Trans R Soc Trop Med Hyg, 1974;68(6):494-5.
    PMID: 4460313
    Matched MeSH terms: Blood/parasitology
  5. Tara HS
    Med J Malaysia, 1974 Mar;28(3):176-9.
    PMID: 4278365
    Matched MeSH terms: Ethanol/blood
  6. Banerjee B, Saha N
    Med J Malaya, 1968 Jun;23(4):332-6.
    PMID: 4235599
    Matched MeSH terms: Cholesterol/blood*
  7. Tara HS, Khuan OY
    Med J Malaya, 1968 Jun;23(4):302-5.
    PMID: 4235594
    Matched MeSH terms: Alcoholic Intoxication/blood
  8. Wan Nor Arifin, Wan Arfah Nadiah, Muhammad Irfan, Chen, Xin Wee, Nani Draman, Nyi, Nyi Naing
    MyJurnal
    To ensure the reliability of manual blood pressure (BP) readings in a clinical trial, sources of error due to measurement must be reduced as much as possible. Apart from following standard procedure for BP measurement and ensuring good equipments, the measurement errors that come from the assessors themselves should be assessed. Objective: To demonstrate the use of two-way random effects, interactions absent, absolute agreement (Type A), single measures (Type 1) intraclass correlation coefficient (ICC) in the assessment of reliability of manual BP readings among assessors involved in a clinical trial using manual BP measurement, by using an interrater reliability study conducted by the authors as an example study. Methods: The steps involved in obtaining ICC in the study were discussed. Sample size given the number of assessors in the study was calculated. BP was measured using regularly maintained mercury sphygnomanometers, following recommendations by Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure (JNC 7) for BP measurement in office setting. The outcomes were systolic and diastolic BP readings. A type of ICC, two-way random effects, interactions absent, absolute agreement (Type A), single measures (Type 1) ICC was chosen for the analysis and specifically discussed. Pre-requisite assumptions for ICC were meticulously checked and described. The interrater reliability for systolic and diastolic BP readings as expressed by ICC (single measure) were presented with confidence interval (CI). The ICCs obtained in the example study were discussed and concluded. The flaws of the study were also criticised. Results: The interrater reliability for systolic and diastolic BP measurements as expressed by ICC (single measure) were 0.87 (95% confidence interval [CI] 0.722, 0.956) and 0.77 (95% CI 0.560, 0.918) respectively. Conclusion: We demonstrated the steps required to obtain ICC. Since the use of manual BP measurement using mercury sphygmomanometer is still considered as gold standard of BP measurement, it is important that studies in which the BP outcome is measured using such method conduct interrater reliability studies properly.
    Matched MeSH terms: Blood Pressure; Blood Pressure Determination
  9. Dondero TJ, Sivanandam S
    Trans R Soc Trop Med Hyg, 1971;65(5):691-3.
    PMID: 5159155
    Matched MeSH terms: Filariasis/blood*
  10. Ng KH, Sen DK
    Med J Malaya, 1971 Dec;26(2):109-11.
    PMID: 4260854
    Matched MeSH terms: Fetal Diseases/blood*
  11. Loh TT, Sinnathuray TA
    Aust N Z J Obstet Gynaecol, 1971 Nov;11(4):254-8.
    PMID: 5289727
    Matched MeSH terms: Iron/blood
  12. Loncin H
    Med J Malaya, 1965 Jun;19(4):321-3.
    PMID: 4220862
    Matched MeSH terms: Blood Pressure*
  13. Blake NM, McDermid EM, Kirk RL, Ong YW, Simons MJ
    Singapore Med J, 1973 Mar;14(1):2-8.
    PMID: 4713017
    Samples from 378 Chinese and 259 Malay blood donors in Singapore have been studied for electrophoretic variants in 13 red cell enzyme systems and for abnormal haemoglobins. Variants were detected in 8 of the enzyme systems, and the frequencies were polymorphic for acid phosphatase, 6 phosphogluconate dehydrogenase phosphoglucomutase (locus 1) among both Chinese and Malays, and for adenylate kinase also among Malays. Rare variants were detected in the phosphohexose, NADH diaphorase and lactate dehydrogenase systems. A new GPGD phenotype and three new LDH phenotypes have been described. Electrophoretic variants of haemoglobin were more frequent among Malays than among Chinese.
    Matched MeSH terms: Acid Phosphatase/blood; Glucose-6-Phosphate Isomerase/blood; L-Lactate Dehydrogenase/blood; Dihydrolipoamide Dehydrogenase/blood; Phosphoglucomutase/blood; Phosphogluconate Dehydrogenase/blood; Phosphotransferases/blood
  14. Sulaiman, I.M., HS, Lee, Balan, S., Jaafar, M.Z.
    Medicine & Health, 2006;1(1):20-24.
    MyJurnal
    Fifty Non Insulin Dependent Diabetes Mellitus (NIDDM) patients undergoing surgery under epidural anaesthesia were studied. All patients received dextrose 5% infusion at 100 ml/hr from the period of fasting until upon arrival to the operation room. Patients were randomly divided into two groups. Patients in Group 1 (n=25) received normal saline while patients in Group 2 (n=25) were given Ringer’s lactate. Both groups received their infusion throughout the operative period up to four hours postoperatively. Blood glucose level was measured at baseline, 45 minutes intra operatively and postoperatively at 30 minutes and four hours by using a glucometer. Patients in Group 2 has a larger mean increase in blood glucose level of 1.5 mmol/L between 4 hours postoperatively and baseline compared to 0.96 mmol/L in Group 1. However, this was not statistically significant. There was no difference in the increase of mean glucose level at 30 minutes when compared to baseline. There was a significant increase in mean blood glucose level in both groups in the postoperative period when compared to baseline. This study demonstrated that patients with NIDDM receiving Ringer’s lactate has a larger increase in mean blood glucose level compared to those receiving normal saline, but the magnitude is not statistically significant.
    Matched MeSH terms: Blood Glucose; Blood Glucose Self-Monitoring
  15. Buttery JE, de Witt GF, Ahmad UO
    Med J Malaya, 1969 Jun;23(4):265-8.
    PMID: 4242173
    Matched MeSH terms: Blood Urea Nitrogen*
  16. LAU KS, SINGH N
    Med J Malaysia, 1963 Dec;18:107-15.
    PMID: 14117278
    Matched MeSH terms: Blood Coagulation Tests*
  17. ENG LI, LONCIN M, PILLAY RP
    Med J Malaysia, 1964 Jun;18:219-22.
    PMID: 14199436
    Matched MeSH terms: Blood Coagulation Tests*
  18. LAU KS, LOPEZ CG, GAN OM
    Med J Malaya, 1962 Mar;16:184-92.
    PMID: 14462716
    Matched MeSH terms: Cholesterol/blood*
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links