Displaying publications 61 - 80 of 117 in total

Abstract:
Sort:
  1. Zainudin NS, Othman N, Muhi J, Abdu Sani AA, Noordin R
    Am J Trop Med Hyg, 2015 Dec;93(6):1268-73.
    PMID: 26392156 DOI: 10.4269/ajtmh.15-0333
    This study was performed to identify circulating Plasmodium falciparum proteins in patient serum, which may be useful as diagnostic markers. Depletion of highly abundant proteins from each pooled serum sample obtained from P. falciparum-infected patients and healthy individuals was performed using the Proteoseek Antibody-Based Albumin/IgG Removal Kit (Thermo Scientific, Rockford, IL). In analysis 1, the depleted serum was analyzed directly by NanoLC-MS/MS. In analysis 2, the depleted serum was separated by two-dimensional electrophoresis followed by western blot analysis. Subsequently, the selected band was analyzed by NanoLC-MS/MS. The result of analysis 1 revealed the presence of two mature erythrocyte surface antigen (MESA) proteins and chloroquine resistance transporter protein (PfCRT). In addition, analysis 2 revealed an antigenic 75-kDa band when the membrane was probed with purified IgG from the pooled serum obtained from P. falciparum-infected patients. MS/MS analysis of this protein band revealed fragments of P. falciparum MESA proteins. Thus, in this study, two different analyses revealed the presence of Plasmodium MESA protein in pooled serum from malaria patients; thus, this protein should be further investigated to determine its usefulness as a diagnostic marker.
  2. Teh AY, Amerizadeh A, Osman S, Yunus MH, Noordin R
    Pathog Glob Health, 2016 Oct-Dec;110(7-8):277-286.
    PMID: 27697019
    The IgG avidity assay is an important tool in the management of suspected toxoplasmosis in pregnant women. This study aimed to produce new Toxoplasma gondii recombinant proteins and to assess their usefulness in an IgG avidity assay. Toxoplasma positive and negative serum samples were used, the former were categorized into low (LGA) and high (HGA) IgG avidity samples. Immunoblots were performed on 30 T. gondii cDNA clones to determine the reactivity and IgG avidity to the expressed proteins. Two of the clones were found to have diagnostic potential and were analyzed further; AG12b encoded T. gondii apical complex lysine methyltransferase (AKMT) protein and AG18 encoded T. gondii forkhead-associated (FHA) domain-containing protein. The His-tagged recombinant proteins, rAG12b and rAG18, were expressed and tested with LGA and HGA samples using an IgG avidity western blot and ELISA. With the IgG avidity western blot, rAG12b identified 86.4% of LGA and 90.9% of HGA samples, whereas rAG18 identified 81.8% of both LGA and HGA samples. With the IgG avidity ELISA, rAG12b identified 86.4% of both LGA and HGA samples, whereas rAG18 identified 77.3% of LGA and 86.4% of HGA serum samples. This study showed that the recombinant antigens were able to differentiate low avidity and high avidity serum samples, suggesting that they are potential candidates for use in the Toxoplasma IgG avidity assay.
  3. Saidin S, Yunus MH, Othman N, Lim YA, Mohamed Z, Zakaria NZ, et al.
    Pathog Glob Health, 2017 May;111(3):128-136.
    PMID: 28335696 DOI: 10.1080/20477724.2017.1300421
    Entamoeba histolytica infection remains a public health concern in developing countries. Early diagnosis of amoebiasis can avoid disease complications, thus this study was aimed at developing a test that can rapidly detect the parasite antigens in stool samples. Rabbits were individually immunized with recombinant pyruvate phosphate dikinase (rPPDK) and E. histolytica excretory-secretory antigens to produce polyclonal antibodies. A rapid dipstick test was produced using anti-rPPDK PAb lined on the dipstick as capture reagent and anti-EhESA PAb conjugated to colloidal gold as the detector reagent. Using E. histolytica-spiked in stool sample of a healthy individual, the detection limit of the dipstick test was found to be 1000 cells ml-1. Meanwhile when rPPDK was spiked in the stool sample, the minimum concentration detected by the dipstick test was 0.1 μg ml-1. The performances of the dipstick, commercial Techlab E. histolytica II enzyme-linked immunosorbent assays (ELISA) and real-time PCR were compared using 70 stool samples from patients infected with Entamoeba species (n = 45) and other intestinal pathogens (n = 25). When compared to real-time PCR, the diagnostic sensitivity of the dipstick for detection of E. histolytica was 65.4% (n = 17/26); while the diagnostic specificity when tested with stool samples containing other intestinal pathogens was 92% (23/25). In contrast, Techlab E. histolytica II ELISA detected 19.2% (5/26) of the E. histolytica-positive samples as compared to real-time PCR. The lateral flow dipstick test produced in this study enabled rapid detection of E. histolytica, thus it showed good potential to be further developed into a diagnostic tool for intestinal amoebiasis.
  4. Mirzadeh A, Saadatnia G, Golkar M, Babaie J, Noordin R
    Protein Expr Purif, 2017 05;133:66-74.
    PMID: 28263855 DOI: 10.1016/j.pep.2017.03.001
    SAG1-related sequence 3 (SRS3) is one of the major Toxoplasma gondii tachyzoite surface antigens and has been shown to be potentially useful for the detection of toxoplasmosis. This protein is highly conformational due to the presence of six disulfide bonds. To achieve solubility and antigenicity, SRS3 depends on proper disulfide bond formation. The aim of this study was to over-express the SRS3 protein with correct folding for use in serodiagnosis of the disease. To achieve this, a truncated SRS3 fusion protein (rtSRS3) was produced, containing six histidyl residues at both terminals and purified by immobilized metal affinity chromatography. The refolding process was performed through three methods, namely dialysis in the presence of chemical additives along with reduced/oxidized glutathione and drop-wise dilution methods with reduced/oxidized glutathione or reduced DTT/oxidized glutathione. Ellman's assay and ELISA showed that the protein folding obtained by the dialysis method was the most favorable, probably due to the correct folding. Subsequently, serum samples from individuals with chronic infection (n = 76), probable acute infection (n = 14), and healthy controls (n = 81) were used to determine the usefulness of the refolded rtSRS3 for Toxoplasma serodiagnosis. The results of the developed IgG-ELISA showed a diagnostic specificity of 91% and a sensitivity of 82.89% and 100% for chronic and acute serum samples, respectively. In conclusion, correctly folded rtSRS3 has the potential to be used as a soluble antigen for the detection of human toxoplasmosis.
  5. Sahimin N, Lim YAL, Ariffin F, Behnke JM, Basáñez MG, Walker M, et al.
    Parasit Vectors, 2017 May 15;10(1):238.
    PMID: 28506241 DOI: 10.1186/s13071-017-2167-8
    BACKGROUND: The number of migrants working in Malaysia has increased sharply since the 1970's and there is concern that infectious diseases endemic in other (e.g. neighbouring) countries may be inadvertently imported. Compulsory medical screening prior to entering the workforce does not include parasitic infections such as toxoplasmosis. Therefore, this study aimed to evaluate the seroprevalence of T. gondii infection among migrant workers in Peninsular Malaysia by means of serosurveys conducted on a voluntary basis among low-skilled and semi-skilled workers from five working sectors, namely, manufacturing, food service, agriculture and plantation, construction and domestic work.

    METHODS: A total of 484 migrant workers originating from rural locations in neighbouring countries, namely, Indonesia (n = 247, 51.0%), Nepal (n = 99, 20.5%), Bangladesh (n = 72, 14.9%), India (n = 52, 10.7%) and Myanmar (n = 14, 2.9%) were included in this study.

    RESULTS: The overall seroprevalence of T. gondii was 57.4% (n = 278; 95% CI: 52.7-61.8%) with 52.9% (n = 256; 95% CI: 48.4-57.2%) seropositive for anti-Toxoplasma IgG only, 0.8% (n = 4; 95% CI: 0.2-1.7%) seropositive for anti-Toxoplasma IgM only and 3.7% (n = 18; 95% CI: 2.1-5.4%) seropositive with both IgG and IgM antibodies. All positive samples with both IgG and IgM antibodies showed high avidity (> 40%), suggesting latent infection. Age (being older than 45 years), Nepalese nationality, manufacturing occupation, and being a newcomer in Malaysia (excepting domestic work) were positively and statistically significantly associated with seroprevalence (P 

  6. Wong WK, Foo PC, Olivos-Garcia A, Noordin R, Mohamed Z, Othman N, et al.
    Acta Trop, 2017 Aug;172:208-212.
    PMID: 28506795 DOI: 10.1016/j.actatropica.2017.05.017
    Crude soluble antigen (CSA) produced from Entamoeba histolytica trophozoite is conventionally used for serodiagnosis of invasive amoebiasis. However, high background seropositivities by CSA-assay in endemic areas complicate the interpretation of positive result in clinical settings. Instead, incorporating a second assay which indicates active or recent infection into the routine amoebic serology could possibly complement the limitations of CSA-assay. Hence, the present study aimed to evaluate the diagnostic efficacies of indirect ELISAs using CSA and excretory-secretory antigen (ESA) for serodiagnosis of amoebic liver abscess (ALA). Reference standard for diagnosis of ALA at Hospital Universiti Sains Malaysia is based on clinical presentation, radiological imaging and positive indirect haemagglutination assay (titer ≥256). Five groups of human serum samples collected from the hospital included Group I - ALA diagnosed by the reference standard and pus aspirate analysis using real-time PCR (n=10), Group II - ALA diagnosed by the reference standard only (n=41), Group III - healthy control (n=45), Group IV - other diseases control (n=51) and Group V - other infectious diseases control (n=31). For serodiagnosis of ALA serum samples (Group I and II), CSA-ELISA showed sensitivities of 100% for both groups, while ESA-ELISA showed sensitivities of 100% and 88%, respectively. For serodiagnosis of non-ALA serum samples (Group III, IV and V), CSA-ELISA showed specificities of 91%, 75% and 100%, respectively; while ESA-ELISA showed specificities of 96%, 98% and 100%, respectively. Indirect ELISAs using CSA and ESA have shown distinct strength for serodiagnosis of ALA, in terms of sensitivity and specificity, respectively. In conclusion, parallel analysis by both assays improved the overall efficacies of amoebic serology as compared to either single assay.
  7. Noordin R, Mohd Zain SN, Yunus MH, Sahimin N
    Trans R Soc Trop Med Hyg, 2017 08 01;111(8):370-372.
    PMID: 29206992 DOI: 10.1093/trstmh/trx062
    Background: Malaysia aims to eliminate lymphatic filariasis (LF) by the year 2020, thus the potential threat of LF from migrant workers needs to be investigated.

    Methods: Brugian and bancroftian filariasis among 484 migrant workers from six countries were investigated using rapid tests based on detection of specific IgG4 antibodies against BmR1 (Brugia Rapid) and BmSXP recombinant antigens.

    Results: The seroprevalence of brugian filariasis was very low; however, bancroftian filariasis was notable among workers from India, Nepal and Myanmar.

    Conclusion: Malaysia is not endemic for Wuchereria bancrofti, but harbors the vectors for the parasite, thus the results showed that migrant workers should be monitored for this infection.

  8. Khor BY, Lim TS, Noordin R, Choong YS
    J Mol Graph Model, 2017 09;76:543-550.
    PMID: 28811153 DOI: 10.1016/j.jmgm.2017.07.004
    De novo approach was applied to design single chain fragment variable (scFv) for BmR1, a recombinant antigen from Bm17DIII gene which is the primary antigen used for the detection of anti-BmR1 IgG4 antibodies in the diagnostic of lymphatic filariasis. Three epitopes of the BmR1 was previously predicted form an ab initio derived three-dimensional structure. A collection of energetically favourable conformations was generated via hot-spot-centric approach. This resulted in a set of three different scFv scaffolds used to compute the high shape complementary conformations via dock-and-design approach with the predicted epitopes of BmR1. A total of 4227 scFv designs were generated where 200 scFv designs produced binding energies of less than -20 R.E.U with shape complementarity higher than 0.5. We further selected the design with at least one hydrogen bond and one salt bridge with the epitope, thus resulted in a total of 10, 1 and 19 sFv designs for epitope 1, 2 and 3, respectively. The results thus showed that de novo design can be an alternative approach to yield high affinity in silico scFv designs as a starting point for antibody or specific binder discovery processes.
  9. Mohd Hanafiah K, Arifin N, Bustami Y, Noordin R, Garcia M, Anderson D
    Diagnostics (Basel), 2017 Sep 07;7(3).
    PMID: 28880218 DOI: 10.3390/diagnostics7030051
    Lateral flow assays (LFAs) are the mainstay of rapid point-of-care diagnostics, with the potential to enable early case management and transform the epidemiology of infectious disease. However, most LFAs only detect single biomarkers. Recognizing the complex nature of human disease, overlapping symptoms and states of co-infections, there is increasing demand for multiplexed systems that can detect multiple biomarkers simultaneously. Due to innate limitations in the design of traditional membrane-based LFAs, multiplexing is arguably limited to a small number of biomarkers. Here, we summarize the need for multiplexed LFA, key technical and operational challenges for multiplexing, inherent in the design and production of multiplexed LFAs, as well as emerging enabling technologies that may be able to address these challenges. We further identify important areas for research in efforts towards developing multiplexed LFAs for more impactful diagnosis of infectious diseases.
  10. Saidin S, Othman N, Noordin R
    Am J Trop Med Hyg, 2017 Oct;97(4):1204-1213.
    PMID: 28820699 DOI: 10.4269/ajtmh.17-0132
    Adverse effects and resistance to metronidazole have motivated the search for new antiamoebic agents against Entamoeba histolytica. Control of amoeba growth may be achieved by inhibiting the function of the glycolytic enzyme and pyruvate phosphate dikinase (PPDK). In this study, we screened 10 compounds using an in vitro PPDK enzyme assay. These compounds were selected from a virtual screening of compounds in the National Cancer Institute database. The antiamoebic activity of the selected compounds was also evaluated by determining minimal inhibitory concentrations (MICs) and IC50 values using the nitro-blue tetrazolium reduction assay. Seven of the 10 compounds showed inhibitory activities against the adenosine triphosphate (ATP)/inorganic phosphate binding site of the ATP-grasp domain. Two compounds, NSC349156 (pancratistatin) and NSC228137 (7-ethoxy-4-[4-methylphenyl] sulfonyl-3-oxido-2, 1, 3-benzoxadiazol-3-ium), exhibited inhibitory effects on the growth of E. histolytica trophozoites with MIC values of 25 and 50 μM, and IC50 values of 14 and 20.7 μM, respectively.
  11. Rahumatullah A, Abdul Karim IZ, Noordin R, Lim TS
    Int J Mol Sci, 2017 Nov 22;18(11).
    PMID: 29165352 DOI: 10.3390/ijms18112376
    Helminth parasite infections are significantly impacting global health, with more than two billion infections worldwide with a high morbidity rate. The complex life cycle of the nematodes has made host immune response studies against these parasites extremely difficult. In this study, we utilized two phage antibody libraries; the immune and naïve library were used to identify single chain fragment variable (scFv) clones against a specific filarial antigen (BmR1). The V-gene analysis of isolated scFv clones will help shed light on preferential VDJ gene segment usage against the filarial BmR1 antigen in healthy and infected states. The immune library showed the usage of both lambda and kappa light chains. However, the naïve library showed preferential use of the lambda family with different amino acid distributions. The binding characteristics of the scFv clones identified from this work were analyzed by immunoassay and immunoaffinity pull down of BmR1. The work highlights the antibody gene usage pattern of a naïve and immune antibody library against the same antigen as well as the robust nature of the enriched antibodies for downstream applications.
  12. Yunus MH, Tan Farrizam SN, Abdul Karim IZ, Noordin R
    Am J Trop Med Hyg, 2018 Jan;98(1):32-38.
    PMID: 29141740 DOI: 10.4269/ajtmh.17-0632
    Laboratory diagnosis of toxocariasis is still a challenge especially in developing endemic countries with polyparasitism. In this study, three Toxocara canis recombinant antigens, rTES-26, rTES-30, and rTES-120, were expressed and used to prepare lateral flow immunoglobulin G4 (IgG4) dipsticks. The concordance of the results of the rapid test (comprising three dipsticks) with a commercial IgG-enzyme-linked immunosorbent assay (ELISA) (Cypress Diagnostics, Belgium) was compared against the concordance of two other commercial IgG-ELISA kits (Bordier, Switzerland and NovaTec, Germany) with the Cypress kit. Using Toxocara-positive samples, the concordance of the dipstick dotted with rTES-26, rTES-30, and rTES-120 was 41.4% (12/29), 51.7% (15/29), and 72.4% (21/29), respectively. When positivity with any dipstick was considered as an overall positive rapid test result, the concordance with the Cypress kit was 93% (27/29). Meanwhile, when compared with the results of the Cypress kit, the concordance of IgG-ELISA from NovaTec and Bordier was 100% (29/29) and 89.7% (26/29), respectively. Specific IgG4 has been recognized as a marker of active infection for several helminthic diseases; therefore, the two non-concordant results of the rapid test when compared with the NovaTec IgG-ELISA kit may be from samples of people with non-active infection. All the three dipsticks showed 100% (50/50) concordance with the Cypress kit when tested with serum from individuals who were healthy and with other infections. In conclusion, the lateral flow rapid test is potentially a good, fast, and easy test for toxocariasis. Next, further validation studies and development of a test with the three antigens in one dipstick will be performed.
  13. Chan MK, Lim SK, Miswan N, Chew AL, Noordin R, Khoo BY
    Protein Expr Purif, 2018 Jan;141:52-62.
    PMID: 28893606 DOI: 10.1016/j.pep.2017.09.003
    This study described the isolation of the coding region of human topoisomerase I (TopoI) from MDA-MB-231 and the expression of multiple copy recombinant genes in four Pichia pastoris strains. First, polymerase chain reaction (PCR)-amplification of the enzyme coding region was performed. The PCR fragment was cloned into pPICZ-α-A vector and sequenced. It was then transformed into X33, GS115, SMD1168H and KM71H strains of Pichia. PCR-screening for positive clones was performed, and estimation of multiple copy integrants in each Pichia strain was carried out using agar plates containing increasing concentrations of Zeocin(®). The selected clones of multiple copy recombinant genes were then induced for TopoI expression in shaker flasks. GS115 and SMD1168 were found to be better Pichia strains to accommodate the recombinant gene for the expression of TopoI extracellularly. However, the DNA relaxation activity revealed that only the target enzyme in the culture supernatants of GS115-pPICZ-α-A-TopoI exhibited consistent enzyme activity over the cultivation time-points. Active enzyme activity was inhibited by Camptothecin. The enzyme produced can be used for in-house gel-based DNA relaxation assay development in performing high throughput screening for target-specific growth inhibitors that display similar effect as the TopoI inhibitors. These inhibitors may contribute to the improvement of the treatment of cancer patients.
  14. Arifin N, Yunus MH, Nolan TJ, Lok JB, Noordin R
    Am J Trop Med Hyg, 2018 04;98(4):1165-1170.
    PMID: 29436335 DOI: 10.4269/ajtmh.17-0697
    Strongyloides stercoralis is a human parasite that can cause a long-term infection. In immunosuppressed patients, strongyloidiasis may be fatal when there is overwhelming autoinfection resulting in the migration of large numbers of larvae through many organs. Definitive diagnosis is still a challenge, and a combination of symptoms, microscopic identification, and serology test results are often used to arrive at a clinical decision. However, intermittent larval excretion, low parasite burden, and occult infections are challenges with parasitological diagnosis of infection with S. stercoralis. Meanwhile, serologic tests using immunoglobulin G and parasite antigen extract have problems of cross-reactivity with other helminthic infections. Recombinant antigen-based serodiagnosis is a good alternative to overcome the laboratory diagnostic issues. Herein, we report on the isolation of cDNA clone encoding an antigen of potential diagnostic value identified from immunoscreening of a S. stercoralis cDNA library. The translated protein had highest similarity to Strongyloides ratti immunoglobulin-binding protein 1. The recombinant antigen produced, rSs1a, was assessed using western blot and enzyme-linked immunosorbent assay. The latter showed 96% diagnostic sensitivity and 93% specificity; thus, rSs1a has good potential for use in serodiagnosis of human strongyloidiasis.
  15. Omar N, Hamidon NH, Yunus MH, Noordin R, Choong YS, Lim TS
    Biotechnol Appl Biochem, 2018 May;65(3):346-354.
    PMID: 28833498 DOI: 10.1002/bab.1591
    Phage display has been applied successfully as a tool for the generation of monoclonal antibodies (mAbs). Naive antibody libraries are unique as they are able to overcome several limitations associated with conventional mAb generation methods like the hybridoma technology. Here, we performed an in vitro selection and generation of Fab antibodies against Brugia malayi SXP protein (BmSXP), a recombinant antigen for the detection of lymphatic filariasis. We developed a naïve multi ethnic Fab antibody library with an estimated diversity of 2.99 × 109 . The antibody library was used to screen for mAbs against BmSXP recombinant antigen. Soluble monoclonal Fab antibodies against BmSXP were successfully isolated from the naïve library. The Fab antibodies obtained were expressed and analyzed to show its binding capability. The diversity obtained from a pool of donors from various ethnic groups allowed for a diverse antibody library to be generated. The mAbs obtained were also functional in soluble form, which makes it useful for further downstream applications. We believe that the Fab mAbs are valuable for further studies and could also contribute to improvements in the diagnosis of filariasis.
  16. Vola A, Tamarozzi F, Noordin R, Yunus MH, Khanbabaie S, De Silvestri A, et al.
    Diagn Microbiol Infect Dis, 2018 Sep;92(1):31-33.
    PMID: 29776711 DOI: 10.1016/j.diagmicrobio.2018.04.007
    Rapid diagnostic tests for cystic echinococcosis (CE) are convenient to support ultrasound diagnosis in uncertain cases, especially in resource-limited settings. We found comparable diagnostic performances of the experimental Hyd Rapid Test and the commercial VIRapid HYDATIDOSIS Test, used in our diagnostic laboratory, using samples from well-characterized hepatic CE cases.
  17. Lew MH, Noordin R, Monsur Alam Khan M, Tye GJ
    Pathog Glob Health, 2018 10;112(7):387-394.
    PMID: 30332344 DOI: 10.1080/20477724.2018.1536854
    Toxoplasmosis, a parasitic disease in human and animals, is caused by Toxoplasma gondii. Our previous study has led to the discovery of a novel RAP domain binding protein antigen (TgRA15), an apparent in-vivo induced antigen recognised by antibodies in acutely infected individuals. This study is aimed to evaluate the humoral response and cytokine release elicited by recombinant TgRA15 protein in C57BL/6 mice, demonstrating its potential as a candidate vaccine for Toxoplasma gondii infection. In this study, the recombinant TgRA15 protein was expressed in Escherichia coli, purified and refolded into soluble form. C57BL/6 mice were immunised intradermally with the antigen and CASAC (Combined Adjuvant for Synergistic Activation of Cellular immunity). Antigen-specific humoral and cell-mediated responses were evaluated using Western blot and ELISA. The total IgG, IgG1 and IgG2a antibodies specific to the antigen were significantly increased in treatment group compare to control group. A higher level of interferon gamma (IFN-γ) secretion was demonstrated in the mice group receiving booster doses of rTgRA15 protein, suggesting a potential Th1-mediated response. In conclusion, the rTgRA15 protein has the potential to generate specific antibody response and elicit cellular response, thus potentially serve as a vaccine candidate against T. gondii infection.
  18. Noordin R, Yunus MH, Robinson K, Won KY, Babu S, Fischer PU, et al.
    Am J Trop Med Hyg, 2018 12;99(6):1587-1590.
    PMID: 30350768 DOI: 10.4269/ajtmh.18-0566
    At the end phase of the Global Programme to Eliminate Lymphatic Filariasis, antibody testing may have a role in decision-making for bancroftian filariasis-endemic areas. This study evaluated the diagnostic performance of BLF Rapid™, a prototype immunochromatographic IgG4-based test using BmSXP recombinant protein, for detection of bancroftian filariasis. The test was evaluated using 258 serum samples, comprising 96 samples tested at Universiti Sains Malaysia (in-house) and 162 samples tested independently at three international laboratories in the USA and India, and two laboratories in Malaysia. The independent testing involved 99 samples from Wuchereria bancrofti microfilaria or antigen positive individuals and 63 samples from people who were healthy or had other infections. The in-house evaluation showed 100% diagnostic sensitivity and specificity. The independent evaluations showed a diagnostic sensitivity of 84-100% and 100% specificity (excluding non-lymphatic filarial infections). BLF Rapid has potential as a surveillance diagnostic tool to make "Transmission Assessment Survey"-stopping decisions and conduct post-elimination surveillance.
  19. Ng YL, Olivos-García A, Lim TK, Noordin R, Lin Q, Othman N
    Am J Trop Med Hyg, 2018 12;99(6):1518-1529.
    PMID: 30298805 DOI: 10.4269/ajtmh.18-0415
    Entamoeba histolytica is a protozoan parasite that causes amebiasis and poses a significant health risk for populations in endemic areas. The molecular mechanisms involved in the pathogenesis and regulation of the parasite are not well characterized. We aimed to identify and quantify the differentially abundant membrane proteins by comparing the membrane proteins of virulent and avirulent variants of E. histolytica HM-1:IMSS, and to investigate the potential associations among the differentially abundant membrane proteins. We performed quantitative proteomics analysis using isobaric tags for relative and absolute quantitation labeling, in combination with two mass spectrometry instruments, that is, nano-liquid chromatography (nanoLC)-matrix-assisted laser desorption/ionization-mass spectrometry/mass spectrometry and nanoLC-electrospray ionization tandem mass spectrometry. Overall, 37 membrane proteins were found to be differentially abundant, whereby 19 and 18 membrane proteins of the virulent variant of E. histolytica increased and decreased in abundance, respectively. Proteins that were differentially abundant include Rho family GTPase, calreticulin, a 70-kDa heat shock protein, and hypothetical proteins. Analysis by Protein ANalysis THrough Evolutionary Relationships database revealed that the differentially abundant membrane proteins were mainly involved in catalytic activities (29.7%) and metabolic processes (32.4%). Differentially abundant membrane proteins that were found to be involved mainly in the catalytic activities and the metabolic processes were highlighted together with their putative roles in relation to the virulence. Further investigations should be performed to elucidate the roles of these proteins in E. histolytica pathogenesis.
  20. Ujang J, Sani AAA, Lim BH, Noordin R, Othman N
    Proteomics, 2018 12;18(23):e1700397.
    PMID: 30284757 DOI: 10.1002/pmic.201700397
    Entamoeba histolytica membrane proteins are important players toward the pathogenesis of amoebiasis, but the roles of most of the proteins are not fully understood. Since efficient protein extraction method is crucial for a successful MS analysis, three extractions methods are evaluated for the use in studying the membrane proteome of E. histolytica: Two commercial kits (ProteoExtract from Calbiochem and ProteoPrep from Sigma), and a conventional laboratory method. The results show that ProteoExtract and the conventional method gave higher protein yields compared to ProteoPrep. LC-ESI-MS/MS identifies 456, 482, and 551 membrane fraction proteins extracted using ProteoExtract, ProteoPrep, and a conventional method, respectively. In silico analysis predicts 108 (21%), 235 (45%), and 177 (34%) membrane proteins from the extracts of ProteoExtract, ProteoPrep, and the conventional method, respectively. Furthermore, analysis of the cytosolic and membrane fractions shows the highest selectivity of the membrane proteins using the ProteoPrep extraction kit. Overall, this study reports 828 E. histolytica membrane fraction proteins that include 249 predicted membrane proteins. The data are available via ProteomeXchange with identifier PXD010171.
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links