Displaying publications 61 - 80 of 171 in total

Abstract:
Sort:
  1. Kang YL, Ibrahim S, Pichiah S
    Bioresour Technol, 2015;189:364-369.
    PMID: 25913883 DOI: 10.1016/j.biortech.2015.04.044
    PEDOT was synthesized by chemical polymerisation and characterised for its electrochemical insights. Three different anode configuration, namely graphite plate (GP), carbon cloth (CC) and graphite felt (GF) were then loaded with a fixed amount of PEDOT (2.5 mg/m(2)) denoted as GP-P, CC-P and GF-P respectively. The PEDOT coating improved the electrochemical characteristics and electron transfer capabilities of the anodes. They also contributed for enhanced MFC performances with maximum energy generation along with coulombic efficiency than the unmodified anodes. The morphological characteristics like higher surface area and open structure of felt material promoted both microbial formation and electrochemical active area. A maximum current density of 3.5A/m(2) was achieved for GF-P with CE and COD of 51% and 86% respectively. Thus, the GF-P anode excelled among the studied anodes with synergetic effect of PEDOT coating and structural configuration, making it as a potential optimum anode for MFC application.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  2. Wan Fadhilah Khalik, Ong SA, Wong YS, Nik Athirah Yusoff, Fahmi Ridwan, Ho LN
    Sains Malaysiana, 2015;44:607-612.
    In this study, the photocatalytic degradation of batik wastewater in the presence of zinc oxide (ZnO) as photocatalyst was
    investigated. The effect of various operating parameters, such as pH of batik wastewater, catalyst dosage and aeration
    on the photocatalytic degradation process, was examined. The mineralization of batik wastewater was also evaluated
    through chemical oxygen demand analysis. The decolorization of batik wastewater was enhanced at acidic conditions
    (pH3) which was 88.2% after 10 h irradiated under solar light, meanwhile its mineralization was 286 mg/L after 12 h
    irradiation time. The data obtained for photocatalytic degradation of batik wastewater was well fitted with the LangmuirHinshelwood
    kinetic model. It can be concluded that batik wastewater could be decolorized and mineralized under solar
    light irradiation with presence of ZnO.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  3. Wan Razarinah W, Zalina MN, Noorlidah Abdullah
    Sains Malaysiana, 2015;44:309-316.
    The study monitored the characteristics of the leachate collected from ten different landfills and presented the experimental work for the treatment of leachate by immobilized Trametes menziesii. Variation in biological oxygen demand (BOD), chemical oxygen demand (COD) and ammoniacal nitrogen (NH3-N) showed that the age of the leachate has a significant effect on its characteristics and composition. The BOD5/COD ratio tends to decrease as the age of leachate increases, varying from 0.71 for a relatively 'fresh' leachate to 0.62 for an older (more stabilized) one. Variations in the characteristics of the leachate suggested that these leachates are difficult to treat. The principal pollutants in the leachate samples were organic and ammonia loads. Treatment of leachate using immobilized Trametes menziesii achieved 89.14 and 2.11% removals for leachate BOD5 and COD, respectively. These findings suggested that using immobilized Trametes menziesii can remove promising percentage of BOD and COD leachate.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  4. Moetaz Elsergany, Amimul Ahsan, Md. Maniruzzaman A. Aziz
    Sains Malaysiana, 2015;44:101-106.
    The paper making industry is characterized by high rate of water consumption and hence high rate of wastewater generation. The purpose of this research was to assess and optimize the existing complete mix activate sludge treatment plant that is used to treat the high strength paper mill effluent with the highest possible efficiency at a reasonable cost. The collected paper mill wastewater is equalized in an equalization tank before being pumped to the treatment plant. The treatment plant includes chemical treatment unit, complete mix activated sludge and granular media filtration unit. The results showed that effluent of a chemical treatment unit was found to be relatively similar to the laboratory simulated plain sedimentation unit. It can be concluded that addition of chemical coagulant can be eliminated with an overall saving of chemical addition costs. The complete mixing activated sludge achieved good removal of biochemical oxygen demand (BOD) and chemical oxygen demand (COD). Furthermore, the results showed that the plant is operated under low BOD:P ratio. The treatment efficiency of the plant can be improved by increasing the phosphorous dose to the plant to have BOD:P ratio of 100:0.5 to 100:1. It was found that 50% of the treated effluent is recycled to the manufacturing process, however this percentage can be increased through proper plant optimization and control of nutrient addition to the activated sludge unit.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  5. Suratman S, Mohd Sailan M, Hee Y, Bedurus E, Latif M
    Sains Malaysiana, 2015;44:67-73.
    The Malaysian Department of Environment-Water Quality Index (DOE-WQI) was determined for the Terengganu River basin which is located at the coastal water of the southern South China Sea between July and October 2008. Monthly samplings were carried out at ten sampling stations within the basin. Six parameters listed in DOE-WQI were measured based on standard methods: pH, dissolved oxygen (DO), biochemical oxygen demand (BOD), chemical oxygen demand (COD), total suspended solids (TSS) and ammonical nitrogen (AN). The results indicated the impact of various anthropogenic activities which contribute to high values of BOD, COD, TSS and AN at middle and downstream stations, as compared with the upstream of the basin. The reverses were true for the pH and DO values. The DOE-WQI ranged from 71.5-94.6% (mean 86.9%), which corresponded to a classification status range from slightly polluted to clean. With respect to the Malaysia National Water Quality Standards (NWQS), the level of most of the parameters measured remained at Class I which is suitable for the sustainable conservation of the natural environment, for water supply without treatment and as well as for very sensitive aquatic species. It is suggested that monitoring should be carried out continuously for proper management of this river basin.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  6. Mojiri A, Ziyang L, Tajuddin RM, Farraji H, Alifar N
    J Environ Manage, 2016 Jan 15;166:124-30.
    PMID: 26496842 DOI: 10.1016/j.jenvman.2015.10.020
    Constructed wetland (CW) is a low-cost alternative technology to treat wastewater. This study was conducted to co-treat landfill leachate and municipal wastewater by using a CW system. Typha domingensis was transplanted to CW, which contains two substrate layers of adsorbents, namely, ZELIAC and zeolite. Response surface methodology and central composite design have been utilized to analyze experimental data. Contact time (h) and leachate-to-wastewater mixing ratio (%; v/v) were considered as independent variables. Colour, COD, ammonia, nickel, and cadmium contents were used as dependent variables. At optimum contact time (50.2 h) and leachate-to-wastewater mixing ratio (20.0%), removal efficiencies of colour, COD, ammonia, nickel, and cadmium contents were 90.3%, 86.7%, 99.2%, 86.0%, and 87.1%, respectively. The accumulation of Ni and Cd in the roots and shoots of T. domingensis was also monitored. Translocation factor (TF) was >1 in several runs; thus, Typha is classified as a hyper-accumulator plant.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  7. Din MF, Ponraj M, Low WP, Fulazzaky MA, Iwao K, Songip AR, et al.
    Water Environ Res, 2016 Feb;88(2):118-30.
    PMID: 26803100 DOI: 10.2175/106143015X14362865227913
    In this study, the removal of natural organic matter (NOM) using coconut fiber (CF) and palm oil fiber (POF) was investigated. Preliminary analysis was performed using a jar test for the selection of optimal medium before the fabricated column model experiment. The equilibrium studies on isotherms and kinetic models for NOM adsorption were analyzed using linearized correlation coefficient. Results showed that the equilibrium data were fitted to Langmuir isotherm model for both CF and POF. The most suitable adsorption model was the pseudo-first-order kinetic model for POF and pseudo-second-order kinetic model for CF. The adsorption capacities achieved by the CF and POF were 15.67 and 30.8 mg/g respectively. Based on this investigation, it can be concluded that the POF is the most suitable material for the removal of NOM in semi polluted river water.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  8. Tee PF, Abdullah MO, Tan IA, Mohamed Amin MA, Nolasco-Hipolito C, Bujang K
    Bioresour Technol, 2016 May 28;216:478-485.
    PMID: 27268432 DOI: 10.1016/j.biortech.2016.05.112
    An air-cathode MFC-adsorption hybrid system, made from earthen pot was designed and tested for simultaneous wastewater treatment and energy recovery. Such design had demonstrated superior characteristics of low internal resistance (29.3Ω) and favor to low-cost, efficient wastewater treatment and power generation (55mW/m(3)) with average current of 2.13±0.4mA. The performance between MFC-adsorption hybrid system was compared to the standalone adsorption system and results had demonstrated great pollutants removals of the integrated system especially for chemical oxygen demand (COD), biochemical oxygen demand (BOD3), total organic carbon (TOC), total volatile solids (TVS), ammoniacal nitrogen (NH3-N) and total nitrogen (TN) because such system combines the advantages of each individual unit. Besides the typical biological and electrochemical processes that happened in an MFC system, an additional physicochemical process from the activated carbon took place simultaneously in the MFC-adsorption hybrid system which would further improved on the wastewater quality.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  9. Naje AS, Chelliapan S, Zakaria Z, Abbas SA
    J Environ Manage, 2016 Jul 1;176:34-44.
    PMID: 27039362 DOI: 10.1016/j.jenvman.2016.03.034
    This paper investigates the optimum operational conditions of a novel rotated bed electrocoagulation (EC) reactor for the treatment of textile wastewater. The effect of various operational parameters such as rotational speed, current density (CD), operational time (RT), pH, temperature, and inter-electrode distance (IED) on the pollutant removal efficiency were examined. In addition, the consumption of aluminum (Al) and electrical energy, as well as operating costs at optimum conditions were also calculated. The results indicated that the optimum conditions for the treatment of textile wastewater were achieved at CD = 4 mA/cm(2), RT = 10 min, rotational speed = 150 rpm, pH = 4.57, temperature = 25 °C, and IED = 1 cm. The electrode consumption, energy consumption, and operating costs were 0.038 kg/m(3), 4.66 kWh/m(3) and 0.44 US$/m(3), respectively. The removal efficiencies of chemical oxygen demand (COD), biological oxygen demand (BOD), total suspended solid (TSS), turbidity and color were 97.10%, 95.55%, 98%, 96% and 98.50%, respectively, at the first 10 min of reaction time, while the phenol compound of the wastewater was almost entirely removed (99.99%). The experimental results confirm that the new reactor design with rotated anode impellers and cathode rings provided high treatment efficiency at a reduced reaction time and with lower energy consumption.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  10. Hashim SA, Samsudin FN, Wong CS, Abu Bakar K, Yap SL, Mohd Zin MF
    Arch Biochem Biophys, 2016 09 01;605:34-40.
    PMID: 27056469 DOI: 10.1016/j.abb.2016.03.032
    A modular typed dielectric barrier discharge (DBD) device is designed and tested for air and water remediation. The module is made of a number of DBD tubes that can be arranged in series or parallel. Each of the DBD tubes comprises inner electrode enclosed with dielectric barrier and arranged as such to provide a gap for the passage of gases. Non-thermal plasma generated in the gap effectively creates gaseous chemical reactions. Its efficacy in the remediation of gas stream containing high NOx, similar to diesel emission and wastewater containing latex, are presented. A six tubes DBD module has successfully removed more than 80% of nitric oxide from the gas stream. In another arrangement, oxygen was fed into a two tubes DBD to generate ozone for treatment of wastewater. Samples of wastewater were collected from a treatment pond of a rubber vulcanization pilot plant. The water pollution load was evaluated by the chemical oxygen demand (COD) and biological oxygen demand (BOD5) values. Preliminary results showed some improvement (about 13%) on the COD after treatment and at the same time had increased the BOD5 by 42%. This results in higher BOD5/COD ratio after ozonation which indicate better biodegradability of the wastewater.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  11. Aljuboury DA, Palaniandy P, Abdul Aziz HB, Feroz S, Abu Amr SS
    Water Sci Technol, 2016 Sep;74(6):1312-1325.
    PMID: 27685961
    The aim of this study is to investigate the performance of combined solar photo-catalyst of titanium oxide/zinc oxide (TiO2/ZnO) with aeration processes to treat petroleum wastewater. Central composite design with response surface methodology was used to evaluate the relationships between operating variables for TiO2 dosage, ZnO dosage, air flow, pH, and reaction time to identify the optimum operating conditions. Quadratic models for chemical oxygen demand (COD) and total organic carbon (TOC) removals prove to be significant with low probabilities (<0.0001). The obtained optimum conditions included a reaction time of 170 min, TiO2 dosage (0.5 g/L), ZnO dosage (0.54 g/L), air flow (4.3 L/min), and pH 6.8 COD and TOC removal rates of 99% and 74%, respectively. The TOC and COD removal rates correspond well with the predicted models. The maximum removal rate for TOC and COD was 99.3% and 76%, respectively at optimum operational conditions of TiO2 dosage (0.5 g/L), ZnO dosage (0.54 g/L), air flow (4.3 L/min), reaction time (170 min) and pH (6.8). The new treatment process achieved higher degradation efficiencies for TOC and COD and reduced the treatment time comparing with other related processes.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  12. Oh KS, Poh PE, Chong MN, Chan ES, Lau EV, Saint CP
    Carbohydr Polym, 2016 Sep 05;148:161-70.
    PMID: 27185127 DOI: 10.1016/j.carbpol.2016.04.039
    Polyelectrolyte-complex bilayer membrane (PCBM) was fabricated using biodegradable chitosan and alginate polymers for subsequent application in the treatment of bathroom greywater. In this study, the properties of PCBMs were studied and it was found that the formation of polyelectrolyte network reduced the molecular weight cut-off (MWCO) from 242kDa in chitosan membrane to 2.71kDa in PCBM. The decrease in MWCO of PCBM results in better greywater treatment efficiency, subsequently demonstrated in a greywater filtration study where treated greywater effluent met the household reclaimed water standard of <2 NTU turbidity and <30ppm total suspended solids (TSS). In addition, a further 20% improvement in chemical oxygen demand (COD) removal was achieved as compared to a single layer chitosan membrane. Results from this study show that the biodegradable PCBM is a potential membrane material in producing clean treated greywater for non-potable applications.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  13. Kawai M, Nagao N, Kawasaki N, Imai A, Toda T
    J Environ Manage, 2016 Oct 01;181:838-846.
    PMID: 27449962 DOI: 10.1016/j.jenvman.2016.06.057
    The recalcitrant landfill leachate was anaerobically digested at various mixing ratios with labile synthetic wastewater to evaluate the degradation properties of recalcitrant wastewater. The proportion of leachate to the digestion system was increased in three equal steps, starting from 0% to 100%, and later decreased back to 0% with the same steps. The chemical oxygen demand (COD) for organic carbon and other components were calculated by analyzing the COD and dissolved organic carbon (DOC), and the removal efficiencies of COD carbon and COD others were evaluated separately. The degradation properties of COD carbon and COD others shifted owing to changing of substrate degradability, and the removal efficiencies of COD carbon and COD others were improved after supplying 100% recalcitrant wastewater. The UV absorptive property and total organic carbon (TOC) of each molecular size using high performance liquid chromatography (HPLC)-size exclusion chromatography (SEC) with UVA and TOC detectors were also investigated, and the degradability of different molecular sizes was determined. Although the SEC system detected extracellular polymeric substances (EPS), which are produced by microbes in stressful environments, during early stages of the experiment, EPS were not detected after feeding 100% recalcitrant wastewater. These results suggest that the microbes had acclimatized to the recalcitrant wastewater degradation. The high removal rates of both COD carbon and COD others were sustained when the proportion of labile wastewater in the substrate was 33%, indicating that the effective removal of recalcitrant COD might be controlled by changing the substrate's degradability.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  14. Darajeh N, Idris A, Fard Masoumi HR, Nourani A, Truong P, Sairi NA
    J Environ Manage, 2016 Oct 01;181:343-352.
    PMID: 27393941 DOI: 10.1016/j.jenvman.2016.06.060
    While the oil palm industry has been recognized for its contribution towards economic growth and rapid development, it has also contributed to environmental pollution due to the production of huge quantities of by-products from the oil extraction process. A phytoremediation technique (floating Vetiver system) was used to treat Palm Oil Mill Secondary Effluent (POMSE). A batch study using 40 L treatment tanks was carried out under different conditions and Response Surface Methodology (RSM) was applied to optimize the treatment process. A three factor central composite design (CCD) was used to predict the experimental variables (POMSE concentration, Vetiver plant density and time). An extraordinary decrease in organic matter as measured by BOD and COD (96% and 94% respectively) was recorded during the experimental duration of 4 weeks using a density of 30 Vetiver plants. The best and lowest final BOD of 2 mg/L was obtained when using 15 Vetiver plants after 13 days for low concentration POMSE (initial BOD = 50 mg/L). The next best result of BOD at 32 mg/L was obtained when using 30 Vetiver plants after 24 days for medium concentration POMSE (initial BOD = 175 mg/L). These results confirmed the validity of the model, and the experimental value was determined to be quite close to the predicted value, implying that the empirical model derived from RSM experimental design can be used to adequately describe the relationship between the independent variables and response. The study showed that the Vetiver system is an effective method of treating POMSE.
    Matched MeSH terms: Biological Oxygen Demand Analysis*
  15. Neoh CH, Lam CY, Ghani SM, Ware I, Sarip SH, Ibrahim Z
    3 Biotech, 2016 Dec;6(2):143.
    PMID: 28330215 DOI: 10.1007/s13205-016-0455-1
    The biggest agricultural sector that contributes to the Malaysian economy is the oil palm industry. The effluent generated during the production of crude palm oil known as palm oil mill effluent (POME). POME undergoes anaerobic treatment that requires long retention time and produces large amount of methane that consequently contributes to global warming. In this study, an isolated bacteria was selected based on its ability to degrade kraft lignin (KL) and identified as Ochrobactrum sp. The bacteria were able to treat POME (from anaerobic pond) under the aerobic condition without addition of nutrient, resulting in a significant chemical oxygen demand (COD) removal of 71 %, removal rate of 1385 mg/l/day, and 12.3 times higher than that of the ponding system. It has also resulted in 60 % removal of ammoniacal nitrogen and 55 % of total polyphenolic after 6-day treatment period with the detection of lignocellulolytic enzymes.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  16. Lin CK, Bashir MJ, Abu Amr SS, Sim LC
    Water Sci Technol, 2016 Dec;74(11):2675-2682.
    PMID: 27973372
    The aim of the current study is to evaluate the effectiveness of combined persulphate with hydrogen peroxide (S2O8(2-)/H2O2) oxidation as a post-treatment of biologically treated palm oil mill effluent (POME) for the first time in the literature. The removal efficiencies of chemical oxygen demand (COD), ammoniacal nitrogen (NH3-N), and suspended solids (SS) were 36.8%, 47.6%, and 90.6%, respectively, by S2O8(2-) oxidation alone under certain operation conditions (i.e., S2O8(2-) = 0.82 g, pH 11, and contact time 20 min). Nevertheless, the combined process (S2O8(2-)/H2O2) achieved 75.8% and 87.1% removals of NH3-N and SS, respectively, under 2.45/1.63 g/g H2O2/S2O8(2-), pH 11, and 20 min oxidation. Moreover, 56.9% of COD was removed at pH 8.4.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  17. Ab Halim MH, Nor Anuar A, Abdul Jamal NS, Azmi SI, Ujang Z, Bob MM
    J Environ Manage, 2016 Dec 15;184(Pt 2):271-280.
    PMID: 27720606 DOI: 10.1016/j.jenvman.2016.09.079
    The effect of temperature on the efficiency of organics and nutrients removal during the cultivation of aerobic granular sludge (AGS) in biological treatment of synthetic wastewater was studied. With this aim, three 3 L sequencing batch reactors (SBRs) with influent loading rate of 1.6 COD g (L d)(-1) were operated at different high temperatures (30, 40 and 50 °C) for simultaneous COD, phosphate and ammonia removal at a complete cycle time of 3 h. The systems were successfully started up and progressed to steady state at different cultivation periods. The statistical comparison of COD, phosphate and ammonia for effluent from the three SBRs revealed that there was a significant difference between groups of all the working temperatures of the bioreactors. The AGS cultivated at different high temperatures also positively correlated with the accumulation of elements including carbon, oxygen, phosphorus, silicon, iron, aluminium, calcium and magnesium that played important roles in the granulation process.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  18. Bashir MJ, Mau Han T, Jun Wei L, Choon Aun N, Abu Amr SS
    Water Sci Technol, 2016;73(11):2704-12.
    PMID: 27232407 DOI: 10.2166/wst.2016.123
    As the ponding system used to treat palm oil mill effluent (POME) frequently fails to satisfy the discharge standard in Malaysia, the present study aimed to resolve this problem using an optimized electrocoagulation process. Thus, a central composite design (CCD) module in response surface methodology was employed to optimize the interactions of process variables, namely current density, contact time and initial pH targeted on maximum removal of chemical oxygen demand (COD), colour and turbidity with satisfactory pH of discharge POME. The batch study was initially designed by CCD and statistical models of responses were subsequently derived to indicate the significant terms of interactive process variables. All models were verified by analysis of variance showing model significances with Prob > F < 0.01. The optimum performance was obtained at the current density of 56 mA/cm(2), contact time of 65 min and initial pH of 4.5, rendering complete removal of colour and turbidity with COD removal of 75.4%. The pH of post-treated POME of 7.6 was achieved, which is suitable for direct discharge. These predicted outputs were subsequently confirmed by insignificant standard deviation readings between predicted and actual values. This optimum condition also permitted the simultaneous removal of NH3-N, and various metal ions, signifying the superiority of the electrocoagulation process optimized by CCD.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  19. Jong VS, Tang FE
    Water Sci Technol, 2016;73(4):909-15.
    PMID: 26901735 DOI: 10.2166/wst.2015.563
    Individual septic tanks are the most common means of on-site sanitation in Malaysia, but they result in a significant volume of septage. A two-staged vertical flow constructed wetlands (VFCWs) system for the treatment of septage was constructed and studied in Sarawak, Malaysia. Raw septage was treated in the first stage wetlands, and the resulting percolate was fed onto the second stage wetlands for further treatment. Here, the effects of a batch loading regime on the contaminant removal efficiency at the second stage wetlands, which included palm kernel shell within their filter substrate, are presented. The batch loading regime with pond:rest (P:R) period of 1:1, 2:2 and 3:3 (day:day) was studied. The improvement of the effluent redox condition was evident with P:R = 3:3, resulting in excellent organic matters (chemical oxygen demand and biochemical oxygen demand) and nitrogen reduction. The bed operated with P:R = 1:1 experienced constant clogging, with a water layer observed on the bed surface. For the P:R = 3:3 regime, the dissolved oxygen profile was not found to decay drastically after 24 hours of ponding, suggesting that the biodegradation mainly occurred during the first day. The study results indicate that a suitable application regime with an adequate rest period is important in VFCWs to ensure efficient operation.
    Matched MeSH terms: Biological Oxygen Demand Analysis
  20. Hilles AH, Abu Amr SS, Hussein RA, Arafa AI, El-Sebaie OD
    Water Sci Technol, 2016;73(1):102-12.
    PMID: 26744940 DOI: 10.2166/wst.2015.468
    The objective of this study was to investigate the performance of employing H2O2 reagent in persulfate activation to treat stabilized landfill leachate. A central composite design (CCD) with response surface methodology (RSM) was applied to evaluate the relationships between operating variables, such as persulfate and H2O2 dosages, pH, and reaction time, to identify the optimum operating conditions. Quadratic models for the following two responses proved to be significant with very low probabilities (<0.0001): chemical oxygen demand (COD) and NH3-N removal. The obtained optimum conditions included a reaction time of 116 min, 4.97 g S2O8(2-), 7.29 g H2O2 dosage and pH 11. The experimental results were corresponding well with predicted models (COD and NH3-N removal rates of 81% and 83%, respectively). The results obtained in the stabilized leachate treatment were compared with those from other treatment processes, such as persulfate only and H2O2 only, to evaluate its effectiveness. The combined method (i.e., /S2O8(2-)/H2O2) achieved higher removal efficiencies for COD and NH3-N compared with other studied applications.
    Matched MeSH terms: Biological Oxygen Demand Analysis
Filters
Contact Us

Please provide feedback to Administrator (afdal@afpm.org.my)

External Links